0% found this document useful (0 votes)
84 views5 pages

DC Machines Lab Manual

The document describes experiments to characterize the performance of various DC machines, including generators and motors. It provides the apparatus used, which includes voltmeters, ammeters, rheostats, and the machines under test. The aims are to draw internal and external characteristics of a compound generator, determine efficiency of identical DC shunt machines, plot open circuit characteristics of a separately excited DC generator, and conduct load tests on DC series and shunt motors to determine their performance characteristics. Diagrams of circuit connections are also mentioned.

Uploaded by

hodeee eee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
84 views5 pages

DC Machines Lab Manual

The document describes experiments to characterize the performance of various DC machines, including generators and motors. It provides the apparatus used, which includes voltmeters, ammeters, rheostats, and the machines under test. The aims are to draw internal and external characteristics of a compound generator, determine efficiency of identical DC shunt machines, plot open circuit characteristics of a separately excited DC generator, and conduct load tests on DC series and shunt motors to determine their performance characteristics. Diagrams of circuit connections are also mentioned.

Uploaded by

hodeee eee
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 5

Exp.

No:1

D.C COMPOUND GENERATOR CHARACTERISTICS


AIM:-
To draw the internal and external characteristics of DC short shunt compound
generator by conducting load test (Both cumulative & differential).
APPARATUS:-

S.N Apparatus Type Range Quantity


o
1 Voltmeter M.C 0-300V
2 Ammeter M.C 0-2A,0-10A Each one
3 Rheostat Wire Wound 360Ω/1.7A, Each one
600Ω/1.7A
4 Tachometer Digital 0-1500 rpm
5 Load box Resistive 230V,10A
6 D.C. compound Compound
generator coupled to DC wound
shunt motor
7 Connecting wires PVC insulated As required

THEORY:-
The method of adding the series field flux with the shunt field flux is known as
compounding. According to method of compounding the compound generators are
classified into two categories.
i) Cumulatively compounding generator.
ii) Differential compounding generator.
In cumulative compounding generator the flux produced by the series field winding
must be right direction with the shunt field flux. ie the series field flux in phase
with the shunt field flux. But in the case of differential compounding generator the
flux produced by the series field winding is in such a direction that it should oppose
Exp.No:5

HOPKINSON’S TEST ON D.C. MACHINES


AIM:
To conduct Hopkinson’s test on two identical DC shunt machine and
determine the efficiency of each machine at various loads.

APPARATUS:

S.No Apparatus Type Range Quantity


1 Voltmeter MC 0-300V 1
2 Voltmeter MC 0-600V 1
3 Ammeter MC 0-2A 2
4 Ammeter MC 0-10A 3
360Ω/1.7A,
5 Rheostat Wire Wound One each
600Ω/1.7A
6 Tachometer Digital 0-3000 rpm 1
DC Shunt identical
7 Shunt wound 1
Machine
Pvc
8 Connecting Wires As required
Insulated

CIRCUIT DIAGRAM:
Exp.No: 3

OPEN CIRCUIT CHARACTERISTICS OF A SEPARATELY


EXCITED D.C. GENERATOR
AIM:-
To plot the open circuit characteristics of a separately exited D.C. generator.
APPARATUS:-
S.no. Apparatus Type Range Quantity
1 Voltmeter MC 0-300V 1
2 Ammeter MC 0-2A 1
3 Rheostat Wire Wound 360Ω/1.7A 1
4 Rheostat Wire Wound 600Ω/1.7A 1
5 Tachometer Digital 0-3000 rpm 1
DC Motor Coupled To
6 Shunt wound 1
DC Generator
7 Connecting Wires Pvc Insulated As required

CIRCUIT DIAGRAM:
Exp.No:8
LOAD TEST ON DC SERIES MOTOR

AIM:

To conduct load test on DC Series motor and to draw its performance


characteristics

APPARATUS:

S.No Apparatus Type Range Quantity


1 Ammeter MC 0-20A 1
2 Voltmeter MC 0-300V 1

3 Tachometer Digital 0-3000 Rpm 1

4 DC Series Motor Series wound 1


5 Connecting Wires Pvc insulated As required
CIRCUIT DIAGRAM:
Exp.No:7
LOAD TEST ON DC SHUNT MOTOR
AIM:

To conduct the brake load test on D.C. shunt motor and determine its
performance characteristics.

APPARATUS:

S.No. Apparatus Type Range Quantity


1 Ammeter MC 0-10A
2 Ammeter MC 0-2A
3 Voltmeter MC 0-300V
4 Rheostat Wire Wound 360Ω/1.7A
5 Tachometer Digital 0-3000rpm
6 DC Shunt Motor Shunt wound
7 Connecting Wires Pvc Insulated As required

CIRCUIT DIAGRAM: