0% found this document useful (0 votes)
418 views5 pages

Fanuc Settings DNC

This document provides cable and parameter configuration settings for various Fanuc control series, including the Fanuc 6, 3, 0, 10/11/12, and 16/18 series. For each control series, it lists the relevant setting data and parameter values to configure things like I/O settings, programming format, communication ports and more. The document warns that only competent operators should change parameter values and to record current values before making any changes.

Uploaded by

coronaqc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
418 views5 pages

Fanuc Settings DNC

This document provides cable and parameter configuration settings for various Fanuc control series, including the Fanuc 6, 3, 0, 10/11/12, and 16/18 series. For each control series, it lists the relevant setting data and parameter values to configure things like I/O settings, programming format, communication ports and more. The document warns that only competent operators should change parameter values and to record current values before making any changes.

Uploaded by

coronaqc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

FANUC

Cable and Parameter configurations


for FANUC controls

Contents
Pocket DNC settings
Fanuc Cable
Fanuc 6 series data and parameter settings
Fanuc 3 series data and parameter settings
Fanuc 0 series data and parameter settings
Fanuc 10/11/12 series data and parameter settings
Fanuc 16/18 series data and parameter settings
Pocket DNC Settings

Standard setting file for Fanuc controls

Fanuc Cable
Warning
Only competent operators should make changes to machine setting data and parameters.
Before changing any parameters please make a note of what they are currently.

Fanuc 6 Series
Setting Data

TV CHECK = 0 (0 : OFF 1: ON)


PUNCH CODE = 1 (0 : EIA 1: ISO)
INPUT UNIT = 0 (0 : MM 1 : INCH)
INPUT DEVICE 1 = 1 (0 : TAPE 1 : RMT)
INPUT DEVICE 2 = 1 (1 : RS232)

Parameters

306 * 0 0 0 1 0 * 0
311 0 0 0 0 1 0 0 1
340 2
341 2

* leave this bit set to what it is currently

Fanuc 3 series
Setting Data

TVON = 0 (0 : OFF 1: ON)


ISO = 1 (0 : EIA 1: ISO)
I/O = 0

Parameters

0005 0 0 0 0 0 0 0 1
0068 4800
Fanuc 0 series
Setting Data

TVON = 0 (0 : OFF 1: ON)


ISO = 1 (0 : EIA 1: ISO)
I/O = 0

Parameters

0002 0 0 0 0 0 0 0 1
0552 10

Fanuc 10/11/12 series


Setting Data

TV CHECK = 0 (0 : OFF 1: ON)


PUNCH CODE = 0 (0 : ISO 1: EIA)
INPUT DEVICE = 1 (1~3 : RS232; 11 : ASR; 13 : RS422)
INPUT DEVICE = 1 (1~3 : RS232; 11 : ASR; 13 : RS422)

Parameters

5001 1
5110 1
5111 2
5112 10
Fanuc 16 & 18 series
Setting Data

TV CHECK = 0 (0 : OFF 1: ON)


PUNCH CODE = 1 (0 : EIA 1: ISO)
I/O CHANNEL = 0 (0~3 : CHANNEL NO)
TAPE FORMAT = 0 (0 : NO CNV 1 : F15)

Parameters

0000 0 0 0 0 0 * 1 0
0020 0
0100 0 0 0 0 0 0 0 0
0101 1 0 0 0 0 0 0 1
0102 0
0103 10

* leave this bit set to what it is currently