Fanuc Settings DNC
Fanuc Settings DNC
Contents
Pocket DNC settings
Fanuc Cable
Fanuc 6 series data and parameter settings
Fanuc 3 series data and parameter settings
Fanuc 0 series data and parameter settings
Fanuc 10/11/12 series data and parameter settings
Fanuc 16/18 series data and parameter settings
Pocket DNC Settings
Fanuc Cable
Warning
Only competent operators should make changes to machine setting data and parameters.
Before changing any parameters please make a note of what they are currently.
Fanuc 6 Series
Setting Data
Parameters
306 * 0 0 0 1 0 * 0
311 0 0 0 0 1 0 0 1
340 2
341 2
Fanuc 3 series
Setting Data
Parameters
0005 0 0 0 0 0 0 0 1
0068 4800
Fanuc 0 series
Setting Data
Parameters
0002 0 0 0 0 0 0 0 1
0552 10
Parameters
5001 1
5110 1
5111 2
5112 10
Fanuc 16 & 18 series
Setting Data
Parameters
0000 0 0 0 0 0 * 1 0
0020 0
0100 0 0 0 0 0 0 0 0
0101 1 0 0 0 0 0 0 1
0102 0
0103 10