Official Manual
Official Manual
0 Preface
Safety Cautions
Ⅰ
User's Manual for TB108 V2.0 Contents
Declaration
Ⅱ
User's Manual for TB108 V2.0 Contents
Product Management
31
Software Version: V2.0
Input/Output Mode
Inspection 50
2 0 0 8. 1 0 Version
Reference & Appendices
52
All copyrights are reserved, any duplication without the prior authorization shall be
forbidden.
R
III
User's Manual for TB108 V2.0 Contents
Contents
Chapter 1: System Configuration&Installation
1、System Configuration&Explanation--------------------------------------page 1
2、Characte ristics of PS6 60BM Control Sys tem-----------------------------page 1
3、Installation and Debugging of Computer Control System---------------page 2
Chapter 2:Explanation of the Key Operations
1、Figure of Keyboard on the Operation Panel (See the figure below)----page 4
2、Explanatio n of the Funct ion Key ------------------------------------------page 5
3 、E xpl anation of t he Para meter setting-------------------------------------- page 6
4、Cursor Key-------------------------------------------------------------------page 7
5、Operation Mode Selection K ey---------------------------------------------page 7
6、El ectrothe rma l ON /O FF key a nd Motor O N/O FF key--------------------pa ge 7
7 、M anual Op eration keyboard------------------------------------------------page 8
8、Setti ng scope of Numeric Items------------------------------------------- page 10
Chapter3:Descriptions on setting parameters/functions
1、The comm on-hompage w hile turning on---------------------------------- page 11
2、The C-machinery's homepage while turning on---------------------------pag e 12
IV
User's Manual for TB108 V2.0 Contents
V
User's Manual for TB108 V2.0 Chapter 1 System Configuration & Installation
1
User's Manual for TB108 V2.0 Chapter 1 System Configuration & Installation
Control Strong
P W 6 00 eletricity
X00
X01
X02
system.
P OWER
X03
X04
X05
X06
X07
POWER Equipment
X10
X11
X12
X13
X14
X15
X16
X17
X20
X21
X22
X23
X24
X25
X26
X27
X30
X31
S t r o ng Strong
Relay
e le tr i ci t y eletricity
board
E qu i p me nt Equipment
P S 66 0 B M
2
User's Manual for TB108 V2.0 Chapter 1 System Configuration & Installation
资 料
(2) Carry on the parameter establish memory test, press DATUM Key , the button on the data, press
输 入 Key, then store the data, cut off the power , put power on after a while , the system will access
ENTER
the model number materials that you store in automatically , if correct, show memory is normal.
(3) Go on establish of every relevant page materials, (particular oprating refer to the parameter enactment
instruction of the third charper .while establishing for the first time, the pressure , speed have better
be a bit more low , strengthen normally progressively after every movement is normal, so as not to
damage the performance of the machine.
(4) After finished relevant parameters established, you should enter the store and check carefully whether
it is normal to each input / export point, checks the warning system in an all-round way, including the
electric eye , going up promptly; the wiring diagram of shut model button going up promptly as follows
promptly.
X10 X11
Going up promptly button.
XCOM
X 00
(5) Left and right shut model button push time difference exceed 2 second , system will alarm, stop all
outputting at the same time; Push the system of going up promptly and stop exporting immediately,
output the open model movements at the same time , operate model chang to by hand .
R
3
User's Manual for TB108 V2.0 Chapter 2 Explanation of the Key Operations
U SB-b us
4
User's Manual for TB108 V2.0 Chapter 2 Explanation of the Key Operations
开锁模
Enter into the screen to set the mold opening & locking movement
M.PLT
射 出 Enter into the screen to set the Glue Shot and pressure-preserving
INJECTION movement
储 料 Enter into the screen to set the feeding, glue taking and automatic
FEEDING material removal movement
座 台/托 模 Enter the page of seat platform, thimble, page slippery model,
NOZZ/EJE. and releasing core and releasing gas.
滑模/中子 Enter the page of slide module .location neutron cutter teeth
TABLE/CORE
时 间
Enter the page of setting up temperature, preheating
TIME
温 度
TEMP.
Enter the page of setting up time, counting
快速设定
Enter the page of Fast setting page I and II
CELERITY SET
监 视
Return to monitor pages at any moment
MONITOR
帮 助
HELP
5
User's Manual for TB108 V2.0 Chapter 2 Explanation of the Key Operations
Keys Usage
PC连 接
Enter into the USB setting page
PC LINK
诊 断
Enter into the alarming page
DIAGNOSE
曲 线
Enter into the Pressure-Speed curve ,Temperature tracing
curve page
CURVE
生产管 理
Enter into Production data modification setting ,SPC tracing record page
FLOW CHART
4 JKL 5
MNO 6 PQR
" OFF " state, this ten numerical keys are locked, guarantee
the materials not to be altered at will . There are 26 English
letters and special symbols separately on 0 to 9 numerical
1 2 3
keys for the mould name inputting in Chinese or English,
STU VWX YZ the inputting machine serial number. [Remove key] you can
press this key to remove the wrong when the parameter or
the serial number name have been wrongly written[Input]
清 除
CLEAR 0 [ ]/ -. key serve as function selection key if there are functions to
be select and as confirm key if there are items to confirm.
6
User's Manual for TB108 V2.0 Chapter 2 Explanation of the Key Operations
4. Vernier key
Keys Usage
Jump rank key, cursor goes the previous line after pressing this key
Change arrange key, cursor goes the left arranging after pressing this key
Change arrange key, cursor goes the right arranging after pressing this key
Jump rank key, cursor goes the previous line after pressing this key
In the manual mode, press a button the indicator in the left up is on which indicates this function has
already been on; the indicator lamp left above is off when press the button once again ,shows this function
state has already been closed , continue press the key, this function will be opened or closed in turn. When
the emergency switch stops, the motor cuts out rapidly, but does not influence the electric heat work.
R
7
User's Manual for TB108 V2.0 Chapter 2 Explanation of the Key Operations
开 模
Open mould operate 1 . turning on mould don't reach stop position;
MOLD OPEN
射 退
1. the temperature of material tube already reached
Jet back operation
the establishing value range;
SUCK BACK
座台进
The operation of seat
1 . unconditional;
move forward
NOZZLE ADV.
座台退
The operation of seat
1 . unconditional;
move back
NOZZLE RET.
调 模
The operating of 1. the speed of t adjusting he mould to slow down
adjusting mould after pressing this key bright;
MOLD ADJ.
吹 气
1. chooses for blowing;
The blowing operation
2. Blow time has not ended;
BLOW
8
User's Manual for TB108 V2.0 Chapter 2 Explanation of the Key Operations
压力测试
The pressure adjusting 1 .after pressing this bright key, you can enter the
operation in advance pressure adjusting operation
PRESS TEST
绞牙进
1.choose to use
wringing tooth operation 2.advance-time not end
3.stop retreating
SCREW ADV
绞牙退
Retreat wringing tooth 1. Choose to use
2. advance-time not end
operation 3. Stop retreating
SCREW RET
9
User's Manual for TB108 V2.0 Chapter 2 Explanation of the Key Operations
Digital≤999Max70 0C
4 The mould materials storing
for actu al use Centig arad e
℃
In case of the set values exceed the above-mentioned scopes, the system will not accept the numbers
set and keep the original set values. For the habit of data input, the data input of this system is display
from right to left.
10
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
You can enter the picture of the machine when push any time after starting the
machine again. This page offer temperature monitor and machine movement monitor. Mould nameand
mould number is establishing by the materials picture of the mould. Temperature arranges and present
oil temperature shows actual value of every sections. You can't alter the materials. Every functionof the
11
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
You can enter the picture of the machine page when push any time after starting
the machine again. This page offer temperature monitor and machine movement monitor. Mould nameand
mould number is establishing by the materials picture of the mould. Temperature arranges and present oil
temperature shows actual value of every sections. You can't alter the materials. Every functionof the picture
stated as follows:
Mode Meanings
Show the motor has already operated;
Show the electric heat has already been opened;
Show lubricate-pump that is pump oil;
Show the electric eye is imported normally;
12
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
诊 断
Re-press key to show the following menus
DIAGNOSE
13
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
Protect-mould time in If low-voltage time arrives, warning Check whether mould have incidental,
you can transfer longer “ low-voltage
low-voltagly arrive, not transferred high-voltage yet. time ”if possible.
Warning when X00 has no signal Please check whether the safety lock
the safely Input trouble input in the course of shutting the is put through normally
mould: and input end X00.is correct connection.
The button trouble of Please check whether left and right
Shutting mould (one shutting mould button connect correctly
pair of slippery moulds As only one X10 and X11 warning to the input end and press normally side
have not this warning ) to side.
At storing material, in “store Check Whether process is unusual
Storing the material and the material in the storage bucket
material prescribe a time limit
has not finished has been used up , if usual, you can
in time ”. Fail to finish storing proper to transfer longer “ store
regularly
material movements: material prescribe a time limit ”.
Open mould has not Fail to open mould to put in place Check mould-open , if no unusual,
in “open the mould to prescribe a you can proper to transfer longer“open
finished regularly
time limit”.
the mould to prescribe a time limit” .
Check whether oil pressure motor
Warning when the motor-protect causes the hot relay to produce
Trouble of the motor
point has signals input movements of protecting because the
overload work.
Check automatic process, if have no
Cycle has already Automatic production cycle goes
unusual, can proper to transfer [cycle
ended beyond setting for [cycle ].
time] established longer .
Solution: If make machine run
Launch output park and modulus-
continually after got output, you can
The output has already opening time has reach output value
put the {Shut down after warning}in
got schedule management page {No}: Or make the
established in advance, the machine
total amount of present no number
stops turning round.
mould-opening as zero.
Opening mould has not When manual tip our , opening Operate lock movements of the mould
got to reservation mould have not got to the stopping again, or check whether the stopping
position position X12 of opening mould put through.
14
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
Alarm Source
The temperature of Eject, The machine material actual temperature tube is higher than the
Seg1,Seg2,Seg3 is high establishing value of upper limit .
The temperature of Eject, The machine material actual temperature tube is lower than the
Seg1,Seg2,Seg3 is low establishing value of upper limit .
Eject, Seg1,Seg2,Seg3 Machine material tube corresponding temperature sensing line
are break break or temperature sensing line have trouble.
Retreating not reach when operating the slippery-mould or shutting-mould , Retreating
the position not reach the position.
The slippery mould has not When operating the thimble or shutting-mould, the slippery-mould
got to the reservation. has not got to the reservation .
Orientation is not up When sliding mold ,but the orientation is not up
Ejection in out limit Input when ejection in out
unnormal
Tooth out neutron out Tooth out /neutron out havenot up when ejection in
have not finished
Operation limited time
The operation time exceed the setting time
is up
Opera te auto, half_auto and other operation key when close
Unbutton close mold
mold button pressed
The automatic clear material when using the automatic clear material , according to the number
is finished of times.established movements.
The function has not been When press a certain function key , but this function has not been
selected for use .
if choose to use motor ,registering motor is not start when press
Please turn on motor,
half / full-automatic key
Withdraw from and press- When choose the pressure adjustment, operation is not increase ,
showing state first reduce buttons .
Enters pressing showing- No pressure adjustment choose, whenpress the key of operation
the state firstly increasing or reducing
15
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
Press CELERITY SET Key,It will enter the first Fast setting page, pictures shows as
快 速设 定
Press Key again,It will enter the second Fast setting page ,pictures
CELERITY SET
The two pages gather all the common parameters information of the machine,
It includes the important parameters for debugging,such as :open mold ,close mold,
ejecting pressure-keepping ,stuff-storing,and temperature.
16
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
17
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
shows as follows:
18
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
储 料
FEEDING
If press key once , you will enter establish pages of storing material /
releasing the glue , the picture shows as follows at this moment:
19
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
座台/托模
If press NOZZ/EJE. key, you will enter a platform / the thimble and set pages, the
(1) The seat rises automatically: Can choose [no use] or [finish storing] or [cooling over ]; if
choose [finish storing] after storing material ,make rising movement when operating auto
mati cally; if choose [cooling over ], after finishing, make a rising movement when operating
automatically.
(2) S eat platform e nter delay: While operating auto matically, delay time is up ,and then the sea t
pla tform ente r
(3) Seat platform retreat delay: While operating automatically , delay time is up,and then the
seat platform retreat
(4) Thimble way: Can choose [order] or [stay]; if choose [stay ], then on semi-automatic state,
enter movement reach terminal then stop to carry, make and carry retreating until the next
circulation before imprison mould.
(5) The times of the thimble: Set the times of thimble movement
(6) Thimble enter delay: While operating automatically, delay time after finishing opening the
mould and then carry enter.
(7) Thimble retreat delay : While operating automatically , delay time after finishing carrying
into enter and then carry and retreat again.
(8) [The note ]: while manually , it is not limited by the times (but can't be 0000 ) .
20
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
滑 模 /中 子
If press TABLE/CORE
key , you will enter the page of slippery mould / orienting setting, the
(1) Slippery model function: Can press the input key to choose [Not Use ] or [Use ], when choose [Use ].
the set way of slippery model is effectively.
(2) Slippery model way: Can press the input key to choose [slip on the left ], [Slip in right ] or [Pair slips ].
(3) Choose slip on the left: Open mould ---Do left slippery movements ---- Slip on the left ----Thimble
----- Thimble finished ---- Wait ----- Press the left / right shut mould button -----Slip in right ----- finish
Slipping in right -----Shut the mould ----- Begin the second circulation.
(4) Choose slip in right: Open mould ---- Do slippery movements in right ---- Slip in right ----Thimble
---- Thimble finished--- Wait --- Press the left / rignt shut the mould button --- Slip on the left -----finish
Slipping on the left ----Shut the mould ----- Begin the second circulation
(5) Choose pair slip: Open mould ---Wait ---Press the left / right shut the mould button, if the model does
slippery movements in right as above -----Then slippery movements on the left -----finish Slipping on
the left ------Shut the mould -------Begin the second circulation.
(6) Single slide machine : slip out if Slip on the left, slip into if slip in right.
(7) The delay slipping on the left: the time from open the mould to the time of beginning slipping left.
(8) The delay slipping on the right: the time from open the mould to the time of beginning slipping right
21
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
滑 模/中 子
If press TABLE/CORE key two times, you will enter the page of release core/ entangle tooth
22
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
时 间
If press TIME key, you will enter time / count setting pages, the picture displays as
(1) Lubricating time: Display that single running time of oil pump.
(2) Lubricate moduluses: calculate the times of opening mould .When the times reach the setting value,
oil pump begin to work.
(3) Middle time: In the full-automatic course, the time is from thimble work finished to the next
circulation lock ,
(4) Movements limited time: The permission longest time that movements are outputted
(5) Cycle time: The limited time of operation cycle in the automatic course, if the time that circulation
operates actually exceeds cycle, the system warn [cycle time is up ].
(6) Warning signal of the trouble: from trouble beginning to the stopping of warning avoid a long time
warning.
23
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
Temperature setting unit is 0.1 [degrees Centigrade ], vertical machine material tube temperature is
feedback to the ring control of control system by K , J Model electric thermocouple line.
System altogether offer five sections temperature controls and a sections of oil temperature measure.
Dozzle can choose [opening ring] /[closing ring ] control. Except controlling temperature, the system
also controls the temperature of every district, see whether it surmounted the upper and lower limit set,
temperature lower than lower limit can not jet glue and melt glue which hinder cold spiral shell's pole start;
temperature is higher than upper limit then warning .Each section temperature states display in the main
picture .
Screw rod cold start: Each segment real temperature will reach the setting scope first time after machine
start, and will keep the setting time.
部 分plastic
Part 塑 胶density
密 度 and
与 料 管heated
tube 加 热temperature
温 度 参 考 for资 料
reference
原料简名 密度 加热温度º CC 原料简名 密度 加热温度º
O O
24
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
Preheating Function: make an appointment in seven days of one week. This system offers the function
that whether some day use the heating in advance or not. You will not use preheat function by choosing
[OFF ]. If you chose [ON ], the system will control the heating of the heating system, according to the
setting value of turning on / off time in the day. The machine will heat the material tube to working temp
erature automatically before the operator works, reduce the time of waiting for .
*[The note ]: The time inputting value adopts 24 hours.It is expressing 12:00 at night if input 00:00
25
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
资 料
Press DATUM key, will enter the mould materials establishing pages, the picture
(1) Mould serial number: This control system can store 80 groups of mould symbols , after altering the
mould serial number, the system output the materials of symbol of the mould automatically.
(2) The mould stores method: Cursor move to the mould serial number colume , import the numberl of
the mould , and then move the cursor to the mould name column, after input the mould name, move
cursor to store column.press the store key to store. this system offer inputting way in English and
spelling.
(3) The mould fetches method: in mould serial number fence , input mould number which will be read ,
move the cursor to ourput column and press the import key to read .this will change the number ar
present and the whole page materials . For prevent from in half / full-automatic mode, page establish
sudden change of parameter will cause harmful effects to product quality and cause contingency
acciden , the mould fetches function is only limited to the manual mode.
(4) Delete method: move the cursor to mould serial number fence , input mould number which will
bedeleted , then import import key to delete in delete fence . the present mould can't be deleted.
(5) the Method that refer the mould: move the cursor to the scanning fenceand utilize upper and lower
key move the picture refer .
26
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
资 料
Press Key twice ,It will enter the data modification record page ,
DATUM
27
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
Press 1 STU
k ey, you will enter the special parameter adjusting / establishing pages,
( 1) Modify the password: move the curso to the “assword modification”. Press
输 入 key ,I t will enter the password modificaion page .
ENTER
28
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
29
User's Manual for TB108 V2.0 Chapter 3: Descriptions on setting parameters/functions
(3a) LCD Contrast adjusting: It means adjust the brightness ratio, at a certain brightness ,The contrst
is greater ,the color is more plentiful. Adjust scope (0-100%) [note :This is only for STN screen]
(3b) LCD brightness adusting: move the cursor to there ,enter the number [adjusting scope (0-100%)],
the brightness of the screen will changed according to the input number.
(3c) LCD color setting :The system offer [the normal, against color ] two kinds of choice, move cursor
background light time can be established, establish the range for 1- 6 minutes, if establishing has
not operated the keybo ard in timing, then the background light automatic OFF.
(3e) keyvoice : The system offer [use/nouse] two choice,move the cursor to that ,then press [enter] key to
(3f) keyvoice up and down : move the cursor to that ,input number [scope (0-10)grade], the volume
will changed according to the input number
(3g) IP address modification: Set the IP address when you use network,move cursor to that then prss
(3j) Current connected state :display the connected state of the network :disconnected/connected.
30
User's Manual for TB108 V2.0 Chapter 4: Product Management
(1) Good product: the good product is equal to the moduluses has already been made multiply by the
quantity of a mould and deduct the bad . The bad product is controlled by the function of shotting and
measure ,when jetting measuring is in use, n the course , if excessive or insufficient state taking place ,
bad product increase one mould quantity value, and warning [measure to the bad product ].
(2) Establishing moduluses: establishing produce Modulus in advance, system automatic reach the frirst
5 moulds of already opening modulus established, the alarming until the modulus arrives.
(3) Shut down warning : Can choose [use ] , [not need ], after establishing moduluses reaching if
choosing no, machine continued producing, did not shut down until after the operator shuts down.
(4) Method that the production record refer: move the cursor to production record fence and utilize
upper and lower key to look out .
31
User's Manual for TB108 V2.0 Chapter 4: Product Management
(1) Pages: 999 modulus continual data in tota,The SPC tracing record offers 6 important parameters of
latest 999 modulus for production management. Let the operator know better the changes of real
tested parameters in every production cycle,and adjust corresponding changes.and then increase the
quanlity of the product.
(2) Print lis: start the print list of the printer
32
User's Manual for TB108 V2.0 Chapter 4: Product Management
3 Pressure-speed curve
曲 线
Press key once ,It will enter into the Pressure -speed curve page ,picture
CURVE
(1) Choose display: Choose the curve you what to display ,can choose [ejection speed],[pressure keeping ]
[mold close pressure], pressing enter key is ok.
33
User's Manual for TB108 V2.0 Chapter 4: Product Management
(1) Choose display: that is ,choose which segment to display its tracing record curve.this function offers
parameters about 6 hr in advance of 6 segments ,temperature.Let the operator know better the
changes of the real temperature, compare and analyse the influence on the quanlity of the product.
(2) The interval of sampling record: that is ,the interval time of sampling record is 5minutes.
34
User's Manual for TB108 V2.0 Chapter 4: Product Management
参parameter
The 数 设定?? establishing explaining
(1 ) Lists:The system offers 999 warnings for inquery at most ,gives maintenance more
convenience.
( 2 ) Print lists:start the print list of the printer.
35
User's Manual for TB108 V2.0 Chapter 4: Product Management
PC连接
P re ss Key once,It will enter USB setting page ,picture shows as follows
PC LINK
at this monment:
参parameter
The 数 设定?? establishing explaining
36
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
Press 0 Key,button In the main picture, you will enter engineer's setting page,
Input the password * * **And then if the password is correct th en your can enter
if incorre ct , you can enter until the correct p assword is entered. Then you can en ter the
systematic parameter setting pages after. If you are the end user of the machine, you need not to
adju st the systematic para meter please contact supplier if there is doubt, otherwise the parameter
is adjusted messily, may damage the performan ce of the lathe and cause unstable or unable to run.
After the password is input correctly, the cursor will jump to the first column on the right
automatically , can choose every column content again with the key ,press, the buttonto
enter. Or press buttons the following and enter the corresponding page directly: press. The
输 入
button enters the page. ENTER
射 出 时 间
<Standby Function Setting>
<Pressure/Flow Setting I>
INJECTION TIME
<Programmable Standby
<Pressure/Flow Setting II> Points>
储 料
<Pressure Pre-Adjustment> 温 度 <Temperature Parameter/
FEEDING <Flow Pre-Adjustment> TEMP. Time Setting>
<Back Pressure Adjustment>
座台/托模 资 料 <Machine No./Ex-Factory
<Electronic Ruler Setting>
NOZZ/EJE. DATUM Value Setting>
37
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
Action Valve
Pressure Valve
Flow Valve
T1 T2 T1 T2
delay time T1 → pressure output ON
(1) The meaning of Start Delay: the
corresponding action valve ON →
flow output ON
(3) The setting ranges for the Start [T1] and the End [T2] are 0.0-0.5 seconds.
38
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
射 出
After entering the correct password, press INJECTION Key twice to enter Pressure/Flow Slope
The Pressure/Flow Slope refers to the steep degree of rise or fall when the pressure/flow changes
from one value to the next value.“1” stands for the slowest change and “16” stands for the fastest
change. The setting range is [1-16].
39
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
The pressure pre-adjustment is the linear adjustment of pressure output. In general, the standard
pressure is 0-800mA and the standard output impedance is 10-20 Ω,unless the manufacturer has specific
requirements since different manufactures' overall oil piping designs and the capabilities of the pressure
proportional valve being used are different.
Pressure Adjustment Method:
The parameters on this page have been set before ex-factory. If the capability of the proportional
valves being used by the user is different, and the normal proportion and linear proportion cannot be achieved,
the parameters on this page can be adjusted. First set the pre-adjustment to be [Activated], and then set the
pre-adjustment item to be [ON]. For example, for the 50 bar pressure position of Item 50, if the reading on
the pressure meter is 45 bar, the parameter of this item should be increased until the pressuremeter reading
reaches 50 bar. Make adjustments on all parameters which need adjusting and make the0-140 bar pressures
being set correspond to the pressures being shown on the oil pressure meter respectively.After the adjustments
are completed, the computer executes automatically linear processing and takes theprocessing results as the
subsequent normal D/A proportional output values.
Press linear pre-adjust:
Enter the number in the 160bar pre-adjustment firstly , then move the cursor to the [pressure linear pr
e-adjust], and press the enter key to choose [on],The system will allocate the data to 10bar -160bar on average.
40
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
The flow pre-adjustment is the linear adjustment of flow output. In general, the standard value
is 0-800mA and the output impedance is 40 Ω,unless the manufacturer has specific requirements since
different manufactures' overall oil piping designs and the capabilities of the pressure proportional valve
being used are different.
41
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
The back pressure pre-adjustment is the linear adjustment of back pressure output. In general, the
standard pressure is 0-800mA and the standard output impedance is 10-20 Ω,unless the manufacturer has
specific requirements since different manufactures' overall oil piping designs and the capabilities of the
pressure proportional valve being used are different.
Back Pressure Adjustment Method:
The parameters on this page have been set before ex-factory. If the capability of the proportional
valves being used by the user is different, and the normal proportion and linear proportion cannot be
achieved, the parameters on this page can be adjusted. First heat the barrel until the barrel temperature
reaches normal melt temperature. Set the melt back pressure to be 1, 10, 20, 30, and more until 160 and
check the actual values. Make adjustments on all parameters which need adjusting and make the 0-160
bar back pressures being set correspond to the back pressures being shown on the back pressure meter
respectively. After the adjustments are completed, the computer executes automatically linear processing
and takes the processing results as the subsequent normal D/A proportional output values.
Back pressure pre-adjust:
Enter the number in the 160bar pre-adjust,then move the cursor to [back pressure linear pre-adjust],
and press the enter key to choose [on],the system will allocate the data to 10bar -160bar on average.
42
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
(1) Electronic Ruler Function: If the equipment needs to use the electronic ruler, choose [Activated]. If the
equipment adopts stroke switch control, choose [Deactivated].
(2) Measurement Values: indicating the actual dynamic positions of the electronic rulers for the clamping
unit, the injection unit and the ejector.
(3) Total Length: referring to the actual lengths of the electronic rulers for the clamping unit, the injection
unit and the ejector.
(4) Limit Position: It refers to the maximum value set for the position. This parameter is subject to the
maximum position setting. For example, if the parameter set is bigger than the limit position value, the
system will not accept the parameter set and will retain the original setting.
(5) Zeroing: When the equipment choose [Activated] for the Electronic Ruler Function and uses the
electronic ruler, it may appear that the mechanic movement stroke is in place and yet the actual
positions of the electronic rulers for the clamping unit, the injection unit and the ejector do not indicate
“0”. In such case, the corresponding ruler should be zeroed. Move the cursor to the zeroing button
for [clamping unit ruler], [injection unit ruler] and [ejector ruler], and then press 输 入 Key to make
ENTER
zero clearing for the corresponding electronic ruler.
(6) Sensor: The method of setting is similar to the elcetornic ruler.
43
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
(1) The ways of thimble stop: Choose the journey and the set will be stop by journey. Choose time and
the set will be stopped by time .
(2) Open mold while storing stuff: Open mold when the cooling time is up ,Needn ,t wait for stroing
stuff end.
(3) The ways of platform retreat: Choose the journey and the set will be stop by journey. Choose time
and the set will be stopped by time .
(4) storing material key locked by itself: when use ,press the key once ,and it will store material continually
until the time or the position of storing materail is up. Or press the key again to end this action.
(5) The motor dallies and stops by oneself : the limited time set ed is effectively that the motor dally while
using.
(6) The motor racing limit time: Set range is 2-999 min, when starting, system measure is in this time, the
machine closes the motor automatically when not doing any operation, in order to protect the life-span
of motor and save the electric rate.
(7) Shut mould self-insurance : [quick][low pres]Can choose fast[quick ] , low-voltage , begin self-insurance
while choosing fast; Begin self-insurance while choosing [low-voltage ] low-voltage .
(8) Shut mould stopping : [While choosing time to the high pressure of shutting mould, high-pressure
time begins to time, time to shutting the mould to stop promptly; Choose journey and end point of
shutting mould is on ,then shutting mould promptly stop.
(9) Shut mould fast: Y51 chooses guide valve to export all the time while opening themould; Choose
differential Y51 and not export while opening the mould.
(10) The slippery mould is used : Can choose pairs of slippery mould , single slipperymould , no need, this
fence function choose will decided is by display of page and using choose of slippery mould function.
(11) Full-automatic : While choosing to use, the machine can run full-automatically.
44
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
( 1 2 ) full-automatic test: the machine will run automaticlly cycle by cycle.this function
,
is only for test and debug in machine factory.it don t use in normal production.it
is in nouse by default when the machine start.
( 1 3 ) Ejecting while clos ing mold:this function only works when double silding mold.
( 1 4 ) Open mol d and download: can choose use or nouse,it will download firsly ,then
open mold slowly when it use.
( 1 5 ) location/entan gle tooth:can choose all nouse or location in use or entangle tooth
in use.
( 1 6 ) Ty pe of machine: can choose common machine or C type machine ,this will
determine the display in monitor page.
滑 模/中子
After entering the engineer page , press key twice ,it will enter into the
TABLE /CORE
功能
The 参数设定??
parameter setting instruction
( 1) Pre ss /F low up limit : these parameters value will determine the up limit in all pages in
mold parameter setting page .
45
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
时 间
After entering the correct password, press TIME
Key to enter the Standby Function
(1) Output Point Transfer Function: This function can be activated or deactivated. If activated, the output
point executes immediately transfer operation. In case that mal-function or damage occurs to a certain
point, the control can be transferred to another point by activating this function. For example, in case
that failure occurs to the mould opening output point and the knockout core function is deactivated, the
Y46 mould opening point can be transferred to Y66 and then the output wires should be exchanged.
The system is equipped with the function of simultaneously transferring two output points. Once this
function is activated, the system makes judgment on the two selected items. If the item is [ON], the
transfer of the pre-set conditions of the item will be executed.
(2) Input Point Transfer Function: This function can be activated or deactivated. If activated, the input
point executes immediately transfer operation. In case that mal-function or damage occurs to a certain
point, the control can be transferred to another point by activating this function. For example, in case
that failure occurs to the front safety door input point and the knockout core function is deactivated,
the X00 front safety door input point can be transferred to X25 and then the input wires should be
exchanged. The system is equipped with the function of simultaneously transferring two input points.
Once this function is activated, the system makes judgment on the two selected items. If the item is
[ON], the transfer of the pre-set conditions of the item will be executed.
46
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
时 间
After entering the correct password, press TIME
Key twice to enter the Programmable
In order to meet diversified application needs and provide an innovative product, we take the
initiative to offer the programmable standby function page so that the users can define and revise by
themselves the functions and the action sequence.
Example 1: For a certain mould injection machine, due to the different design of the oil piping, it
is required that a point is output while clamping at high pressure and the power will not be interrupted
until the melt finishes taking out. To achieve such a special function, choose an item and have it activated,
and then specify an output point (i.e. this function is output through Y xx), and then set the action
sequence [CD].
Notes: Regarding the output scope of Sequence D Clamping Stop, in automatic mode, the clamping
switch is contacted during the process of mould close at high pressure, and this sequence output starts
until the melting finishes; in manual mode, the clamping switch is contacted during the process of mould
close at high pressure, and this sequence output starts until the mould opening key or the reset key is
pressed.
Example 2: For a certain mould injection machine, due to the different design of the oil piping, it
is required that a point is output while injecting and melting. To achieve such a special function, choose
an item and have it activated, and then specify an output point (i.e. this function is output through Y xx),
and then set the action sequence [FH].
47
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
温 度
After entering the correct password, press Key to enter the Temperature
TEMP.
(1) Nozzle ,Seg I ,Seg II ,Seg III ,Seg IV,Seg V : [use] and [nouse] can be chose ,if [nouse],the syestem
will not inspect and control on this segment.
(2) Oil Temperature Selected: [Activated] or [Deactivated] can be chosen. If deactivated, once it is
detected that the oil temperature is equal to or over the set upper limit, the alarm will be neglected.
If activated, the alarm will be output, and the system will turn to manual mode and the motor will be
turned off when the alarm cycle ends.
(3) Pd Setting: Pd has been set before ex-factory. It is recommended that the user should not revise this
parameter under normal circumstance.
(4) Proportion Setting : proportion control is a simplest control way ,the output of the cotroller is
proportionate to the input inaccuracy signal. There will be stable inaccuracy in output only with
proportion controller.
(5) Differentiation control: In differentiation control, the output is directly proportional to the input signal
error differentiation the auto control system maybe vibrate or even instable in the process of overcoming
error.because the existed large inertia component and the lag component can inhibit the error. its change
is always lose behind the change of the error .the solution is to make the change of the inhibition error
in advance .that is when the error is close to zero ,the inhibition error should be zero.so ,the "proporiton"
item is not enough in the controller , the role of "proportion" is only to enlarge the error.we should add the
"differentiation"which can predict the tendency of the error. thus ,with proportion and differentiation ,the
controller will be able to make the role of inhibition error to zero or even negative in advance .and avoid
overadjust of the controller. Therefore, greater Inertia or lag charged object, the proportion of + differential
(PD) controller can improve the system dynamic properties in regulating.
48
User's Manual for TB108 V2.0 Chapter 5 System Debug Setting
(1) Mould Injection Machine No.: The system is equipped with the function of setting NO. for the mould
injection machine so that the manufacturer can set the No. for easy sales management and after-sales
service record.
(2) Ex-Factory Value Restoration: During the modifying process of password pages, if normal operation
cannot be achieved due to too much deviations of the modified parameters, press Key Enter and
choose Confirm, and then all the contents and all the parameters will be restored to the standards valu
es set before ex-factory.
49
User's Manual for TB108 V2.0 Chapter 6 Input/Output Mode Inspection
(1) Press 2 VWX Key on the Main Page to enter Input Inspection Page and the following will be
displayed:
(2) Press 3 YZ Keyon the Main Page to enter Input Inspection Page I and the following will be
displayed:
50
User's Manual for TB108 V2.0 Chapter 6 Input/Output Mode Inspection
(3) Press 3 YZ
Key on the Main Page to enter Key Inspection Page I and the following will be
displayed:
displayed:
NOTE:
The above input inspection pages are used for signal inspection and cannot accept information
modified. The solid box on the display indicates that the signals are being input.
51
User's Manual for TB108 V2.0 Reference & Appendices
210
194 34
178
7
17.8
228
392
470 456
228
6-M4X12 screw
4
7
7
T B 1 0 8 键盘安装尺 寸图
TB 108 Keyboard Installation Size Diagram
R
52
User's Manual for TB108 V2.0 Reference & Appendices
230 48
216
194 42
7
24.5
135
24
228
470 456
247
228
196 20
6-M4X12 screw
4
7
7 T C 1 0 8 键盘安装尺寸 图
TC 108 Keyboard Installation Size Diagram
R
53
User's Manual for TB108 V2.0 Reference & Appendices
135
PW600 POWER SUPPLY 143
151
7.5 7.5
34 15 126 15 35
Figure of开Dimensions
关电源盒 外形 &尺Installation
寸及安 装孔位 Hole
图 Positions
for Power Supply Case 8
5
170
P S660B M 180
190
151 34.5
220
5
6
8
210 19 8
190 PS8 60 BM 202
主机
Figure of Dimensions &外 形 尺 寸 及 安Hole
Installation 装孔位 图
Positions for Master Machine
54
55
R
P
10VG
S
CGN D
CA H
CA L
GND
+24V
+5V
GND
+ 2 4V
GND
+ 2 4V
2 4 VG
+ 3 8V
3 8 VG
Aj2 Aj1
Reference & Appendices User's Manual for TB108 V2.0
User's Manual for TB108 V2.0 Reference & Appendices
56
User's Manual for TB108 V2.0 Reference & Appendices
R S T
3 POWER MCB
Absorption
Component
Absorption MC1 N
Component Coil Interference Absorption
N
Contact Interference Absorption
O.L
Absorption
Component
MOTOR
57