Leading the Industry in
Solar Microinverter Technology
DS3D
2 input channels with independent
MPPT and monitoring function
Single unit connects to four modules
Maximum continuous output power
up to 2000W
Safety protection relay integrated
Arc fault protection function
embedded.
DIMENSIONS
Our flagship new range of Grid-tied microinverters
includes the new DS3D. The APsystems DS3D is a
grid-tied microinverter with intelligent networking
and advanced monitoring systems to ensure
maximum efficiency. High efficiency, high reliability
of the DS3D with 2 independent MPPT inputs,
maximum continuous output power up to 2000W.
Quarter the inverters and quarter the installation
means real cost savings for residential and
commercial customers.
WIRING SCHEMATIC
2021/08/20 Rev1.0
DS3D Microinverter Datasheet
Region LATAM
Input Data (DC)
Recommended PV Module Power (STC) Range 315Wp-670Wp+
Peak Power Tracking Voltage 68V-110V
Operation Voltage Range 60V-120V
Maximum Input Voltage 120V
Maximum Input Current 20A x 2
Output Data (AC)
Maximum Continous Output Power 2000W
Nominal Output Voltage/Range* 240V/ 211V-264V
Adjustable Output Voltage Range 170V-278V
Nominal Output Current 8.3A
Nominal Output Frequency/ Range* 60Hz/59.3Hz-60.5Hz
Adjustable Output Frequency Range 55Hz-65Hz
Maximum Units per Branch** 3
Efficiency
Peak Efficiency 97%
CEC Efficiency 96.7%
Nominal MPPT Efficiency 99.5%
Night Power Consumption 20mW
Mechanical Data
Operating Ambient Temperature Range -40 ℉ to +149 ℉ (-40 °C to +65 °C)
Storage Temperature Range -40 ℉ to +185 ℉ (-40 °C to +85 °C)
Dimensions (W x H x D) 11” × 9” × 2” (283mm X 233mm X 48.4mm)
Weight 8.4lbs(3.8kg)
DC Connector Type MC4
Cooling Natural Convection - No Fans
Enclosure Environmental Rating Type 6
Features
Communication (Inverter To ECU) Encrypted ZigBee
Transformer Design High Frequency Transformers, Galvanically Isolated
Energy Management Energy Management Analysis (EMA) system
Certificate & Compliance
Compliance UL1741 (IEEE1547);CSA C22.2 No. 107.1;NOM-001
*Nominal voltage/frequency range can be extended beyond nominal if required by the utility.
**Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
Specifications subject to change without notice - please ensure you are
using the most recent update found at latam.APsystems.com