0% found this document useful (0 votes)
300 views

Staircase Load Calculation

This document contains calculations for the design of a staircase slab. It includes input parameters like slab thickness, material properties, load calculations, and design checks. Load calculations include self-weight of slab and finishes, as well as imposed live loads. Bending moment and steel reinforcement requirements are calculated. Shear capacity is checked. Reinforcement is sized based on the required area and code spacing requirements. Deflection is checked against code limits. In summary, this document performs structural design calculations for a staircase slab and verifies code compliance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
300 views

Staircase Load Calculation

This document contains calculations for the design of a staircase slab. It includes input parameters like slab thickness, material properties, load calculations, and design checks. Load calculations include self-weight of slab and finishes, as well as imposed live loads. Bending moment and steel reinforcement requirements are calculated. Shear capacity is checked. Reinforcement is sized based on the required area and code spacing requirements. Deflection is checked against code limits. In summary, this document performs structural design calculations for a staircase slab and verifies code compliance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Project

Calculations for Divn/Dept BLI Job Nr 278668 /15A


Calculated by CG Sheet Nr
Checked by PA 0

Floor Beam
REFERENCE DWG NO :
INPUT DATA
1
LENGTH OF TREAD T = 0.30 m 1.43

HEIGHT OF RISER R = 0.15 m MB


GOING G = 0.30 m 2.1
2
WIDTH OF STAIR W = 1100.0 mm
SPAN OF STAIR L = 2.70 m 1.43 1

THICKNESS OF SLAB D = 150 mm 1.43 2.1


EFFECTIVE DEPTH OF SLAB d = 117 mm
Plan

DENSITY OF CONCRETE γ = 25 KN / m3 3.6

STRENGTH OF CONCRETE fck = 25 N/mm2 A

STRENGTH OF STEEL fy = 500 N/mm2


CLEAR COVER c = 25 (as per IS:456-2000
DIAMETER OF MAIN BAR Φ = 16 cl. 33.1.b) 1 B
1) DEAD LOAD
DL DUE TO WAIST = 6.07 KN/m2
FLOOR FINISH = 1.50 KN/m2 Elevation
2
TOTAL DL DUE TO WAIST = 7.57 KN/m Load From slab 2
2
DL DUE TO LANDING SLAB = 3.75 KN/m Load from slab 1
2
FLOOR FINISH = 1.50 KN/m
TOTAL DL DUE TO LANDING SLAB = 5.25 KN/m2
MAX.DEAD LOAD DL = 7.57 KN/m2 1.43
2) LIVE LOAD LL = 4.00 KN/m2 2.70

3) LOAD COMBINATIONS
A) 1.5 x DEAD LOAD ---
LOAD CASE 1 = 11.351 KN/m2

B) 1.5 x D L+ 1.5 x LL ---


LOAD CASE 2 = 17.351 KN/m2
MAX OF ALL LOADS = 17.351 KN/m2
COMBINATIONS
UDL ACTING ON STAIRCASE SLAB ( From Slab 1) = 19.087 KN/m
UDL ACTING ON STAIRCASE SLAB (From slab 2) = 16.381 KN/m
4) DESIGN AS PER IS CODE -
Note = Staircase is designed as a s.s. beam spanning between centres of beams
A) BENDING MOMENT
MAX MOMENT AT MIDSPAN = UDL x L2 / 8
MAX MOMENT AT MIDSPAN = 35.000 KN - m
Project

Calculations for Divn/Dept BLI Job Nr 278668 /15A


Calculated by CG Sheet Nr
Checked by PA 0
B) AREA OF MAIN STEEL

0.5  f ck  
Ast  1  1  4.6  M  Bd
fy  f ck  B  d 2 
 

Ast = 783.408 mm2

C) AREA OF DISTRIBUTION STEEL


Ast(dist.) = 0.12% OF GROSS AREA
= (0.12)xWIDTHxOVERALL THK./100
= 198.000 mm2

D) CHECK FOR SHEAR

Vu
 v 
B  d

Vu,max = (UDL x span)/2


= 25.76689016 N
Hence, tv = 0.200 N/mm2
Percentage of steel = 0.609 %
Corresponding to this percentage as per IS:456-2000, table no.19,
2
tc ≈ 0.55 N/mm
As tv < tc NO SHEAR REINFORCEMENT IS REQUIRED.

5) DETAILING OF MAIN STEEL

AREA OF HYSD 10 DIA. BARS AT 100 c/c = 785.4 mm2


AREA OF HYSD 12 DIA. BARS AT 150 c/c = 753.98 mm2
AREA OF HYSD 16 DIA. BARS AT 150 c/c = 1340.41 mm2
AREA OF HYSD 20 DIA. BARS AT 125 c/c = 2513.27 mm2

USE HYSD 16 DIA. BARS AT 100 c/c FOR MAIN STEEL

6) DETAILING OF DISTRIBUTION STEEL

AREA OF HYSD 8 DIA. BARS AT 200 c/c 251.33 mm2


AREA OF HYSD 10 DIA. BARS AT 150 c/c = 523.6 mm2
AREA OF HYSD 12 DIA. BARS AT 250 c/c = 452.39 mm2
AREA OF HYSD 16 DIA. BARS AT 250 c/c = 804.25 mm2

USE HYSD 10 DIA. BARS AT 200 c/c FOR DISTRIBUTION STEEL


Project

Calculations for Divn/Dept BLI Job Nr 278668 /15A


Calculated by CG Sheet Nr
Checked by PA 0

7) DEFLECTION CHECK

REINF PROVIDED AT MID SPAN Ast pro = 2010.62 mm2

STRESS IN REINFORCEMENT fs = 112.99409 N/mm2

PERCENTAGE OF REINFORCEMENT PROVIDED p = 1.71847863 %

MODIFICATION FACTOR AS PER FIG 4 OF IS 456-2000 MF = 1.25

BASIC SPAN TO EFFECTIVE DEPTH RATIO L/d = 26 For Cont. slab

MINIMUM EFF.DEOTH REQD FROM DEFLECTION CRITERIA dmin = 83 mm

MINIMUM EFFECTIVE DEPTH PROVIDED dpro = 117

greater than 'min. eff depth reqd'. Hence ok