0% found this document useful (0 votes)
143 views21 pages

User Manual For UMTS2100 Bandwidth Adjustable Pico Repeater (ATWS20E1) - 20...

This document provides a user manual for a UMTS2100 Bandwidth Adjustable Digital Pico Repeater. The repeater expands wireless coverage for mobile users by receiving, amplifying, and retransmitting signals. It is designed for indoor use in areas up to 1000 square meters, such as homes, offices, and vehicles. The manual describes the product's features, which include automatic level control, self-oscillation detection, and synchronized uplink and downlink gain adjustment. It also provides instructions on installation, mounting, and using the control buttons and indicators.

Uploaded by

alin7777
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
143 views21 pages

User Manual For UMTS2100 Bandwidth Adjustable Pico Repeater (ATWS20E1) - 20...

This document provides a user manual for a UMTS2100 Bandwidth Adjustable Digital Pico Repeater. The repeater expands wireless coverage for mobile users by receiving, amplifying, and retransmitting signals. It is designed for indoor use in areas up to 1000 square meters, such as homes, offices, and vehicles. The manual describes the product's features, which include automatic level control, self-oscillation detection, and synchronized uplink and downlink gain adjustment. It also provides instructions on installation, mounting, and using the control buttons and indicators.

Uploaded by

alin7777
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 21

USER MANUAL OF UMTS2100

BANDWIDTH ADJUSTABLE DIGITAL PICO


REPEATER

SHENZHEN GUANRI TECHNOLOGY CO., LTD.


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

CONTENT

I. Product introduction ................................................................................................................................ 2

II. Usage scope ............................................................................................................................................. 3

III. Characteristics ........................................................................................................................................ 4

IV. Product Description................................................................................................................................ 5

V. Indicator Instruction Table ...................................................................................................................... 7

VI. commissioning........................................................................................................................................ 9

ViI. Service after Sale ................................................................................................................................. 19

Shenzhen Guanri Technology Co., Ltd. Page 1 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

I. PRODUCT INTRODUCTION

The Pico Repeater provides an affordable solution to solve the indoor signal coverage problems in Triple

system due to signal fading and attenuation caused by architecture obstacles. And its easy installation and

maintenance can help carrier get fast return.

The repeater is working as a relay between the BTS and mobiles. Repeater is applied specially in small area

indoor DAS system. The base station signal is coupled and amplified by PICO Repeater into in-building system.

The amplified signals are transmitted by indoor antenna. Meanwhile the indoor antenna receives the cell

phone signal, and sends the signal to the base station as uplink. This method can eliminate the signal dead

spot, reject the interference, and provide the stable signal communication for cell phone users. This Repeater

mainly solves the problem spot problem in building.

Repeater is a bi-directional amplifier that allows for the reception of signals, amplifies the signal and

re-transmits into areas where there is no or very low signal level coverage enabling mobile user to establish a

call connection.

Repeater can be deployed in indoor coverage. It is especially advantageous to use in 100-1000 Sq.m, which is a

very economical solution.

Shenzhen Guanri Technology Co., Ltd. Page 2 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

II. USAGE SCOPE

To expand signal coverage or fill signal blind area where signal is weak or unavailable.

Residential house villas


basements parking lots
cars high-speed trains
border village
elevators vessels
high-buildings tunnels
countryside mines
Clubs underground facilities

Figure 1 Application Diagram

Shenzhen Guanri Technology Co., Ltd. Page 3 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

III. CHARACTERISTICS

AUTOMATIC LEVEL CONTROL FUNCTION

With the function of digital ALC, the dynamic gain adjustment range is more than 20dB. It ensures the PICO

Repeater works in linear status and provides the high reliability and stability.

SELF-OSCILLATION AUTOMATI C DETECTION FUNCTION

It has the function of self-oscillation automatic detection (The isolation detect when boot time), which detects

the self-oscillation occurred by inadequate isolation between the donor antenna and service antenna. The

PICO Repeater can activate AGC to set the Repeater gain when self-oscillation occurred.

UPLINK/DOWNLINK GAIN ADJUSTMENT SYNCHRONI ZATION UPLINK AND DO WNLINK GAIN


SETUP AUTOMATICALLY

After the system is powered up, the input power is detected automatically and then the output power is
adjusted. After the downlink gain is calculated by the system, the uplink gain can be adjusted equivalently.
This method can balance the system amplification. The both path gain is adjusted relevantly. The system gain
is less than the system path loss. So the Repeater will not bring any interference and noise into the system link.
One base station can hook up more than one Repeater.

Shenzhen Guanri Technology Co., Ltd. Page 4 of 20


UMTS2100 Bandwidth adjustable Digital Pico Repeater User Manual

IV. PRODUCT DESCRIPTI ON

APPEARANCE

Figure 2 View of Repeater

System 1 represent UMTS2100, System 2&system 3 and system 4 are invalid.

Alarm 1 represent UMTS2100, Alarm 2&Alarm 3 and system 4 are invalid.

FIGURE 3 PANEL VIEW OF REPEATER

Shenzhen Guanri Technology Co., Ltd. Page 5 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

INSTALLATION INSTRUCTIONS
1. At the installation site, install the repeater as per specified plan and site layout. The repeater can be pole-mounted or
wall-mounted using the brackets as shown below.

Figure 4 Diagram of Repeater Mounting

1. First of all, choose a mounting position for the Pico Repeater in indoor environment. And then align Pico Mounting
hole on the wall and be marked

2. According to formerly marking on the wall to drill the holes, and inserted the rubber plug in the holes.

3. Use screws fix the Pico’s mounting hole on the wall where Pico is going to be installed.

4. The BTS port on Pico Repeater is connected to the donor antenna, MS port is connected to the service antenna.

5. System is supplied by AC220V power via connection of the external extension power cable.

6. The system works properly under the condition of having enough system isolation.

7. With obstruction or no, it must ensure the distance of 5-30 m between the donor antenna and service antenna.

Shenzhen Guanri Technology Co., Ltd. Page 6 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

V. INDICATOR INSTRUCTION TABLE

BUTTONS FUNCTIONS

The functions of the buttons on the front panel are listed in the table below.

Button Function Explanations

The switch can control the Li-ion battery. Press it to OFF, but ON the battery only
can by the restore AC power supply.(This means this press can only OFF the
Battery Switch
battery),when powered by battery, power indicator off, but the other indicator will
always light green.
Smart mode is defaulted; smart indicator will be lightened. Press this button can
Activate or Deactivate
deactivate or active smart function. Under Smart mode, repeater can adjust
Smart function
again according to input power. We recommend you use Smart mode.

Choose System then press Enter can into setting mode, then press the button
Choose System 1~4 or
decrease the attenuation by 1dB/step, and the LCD monitor would display the
decrease the Gain
current gain value; press Enter button to save the settings.

Choose Uplink and Choose Uplink or Downlink then press Enter can into setting mode, then press
Downlink or Increase the the button increase the attenuation by 1dB/step, and the LCD monitor would
Gain display the current gain value; press Enter button to save the settings.

Choose RSSI or Gain Press the button to LCD will display gain or RSSI value.

Deactive Smart mode first, press “+” and “-“ button choose right system’s uplink
or downlink, Press this button, then value displayed in LCD will be blink, then you
Confirm button
can press press “+” and “-“ button to set gain, after setting press Enter button
again can save setting value and exit setting mode.

Shenzhen Guanri Technology Co., Ltd. Page 7 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

THE LED INDICATORS

The indicators on the front panel could be lightened are listed in the table below

Indicator Status

On means power supply is normal.

Blink means repeater working normal

System 1 On means LCD display value belong to system 1

Alarm 1 On means System 1 AGC is control

When powered by battery, power indicator off, but the BAT indicator will
always light green.

On means repeater work in smart mode.

UL On means value displayed in LCD is for Uplink

DL On means value displayed in LCD is for Downlink

RSSI On means value displayed in LCD is input power

Gain On means value displayed in LCD is Gain

Be noted that users can’t adjust parameters by manual setting when smart function is

activated .Repeater must not be powered on before the donor antenna and service antenna

are connected.

Shenzhen Guanri Technology Co., Ltd. Page 8 of 21


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

VI. COMMISSIONING

COMMISSIONING PREPARATION
1. Connect the RF cable from Donor Antenna to the spectrum analyzer and check if the Donor Antenna is
receiving the correct frequency; and then measure the signal level of the said frequency (RSL). Adjust the
antenna to make the readings approach the recorded value on the survey report. Record all readings.
2. Connect to the MS port to service antenna, and connect the BS port to donor antenna.
3. Turn ON the repeater.

LOCAL SETUP STEPS


Connect your laptop to the repeater via the usb data cable. Do the following steps (the parameters listed in
the steps are mandatory to fill, remaining is defaulted or user defined):

a. Startup the Local Test Program (NMS), the Username is “Admin”,the password is “123456”,and then
click the Login button, click on the Config Data tab from pop-up dialog ,Click on the Config Data tab,
choose the COM Parameters.

Shenzhen Guanri Technology Co., Ltd. Page 9 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

b. From the pop-up dialog, configure the Com Parameters, mark this check box and select

RS232,then click the Config button, choose the correct Com port from your PC, set Baudrate to

9600,and set the Timeout to180.Then click the start button from tool bar.

Start
button

Shenzhen Guanri Technology Co., Ltd. Page 10 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

c. Right click the Site List, then choose New/ Area for create new area.

From pop-up dialog, Click the Create Button,the Area Code should be filled by any number with 2 digits,and

input the Area Name,and then click on OK.

Shenzhen Guanri Technology Co., Ltd. Page 11 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

d. Right click on the area name from Site List, then choose New/Site for create new Repeater.

From pop-up dialog, config the new site(repeater) properties as below: select Protocol 2G for

Protocol Type, select 7.Wideband Repeater from the Main Equipment Type, the Site ID must be

filled by any number with 8 digits, and the Sub ID must be “255”, then click OK for save settings.

Shenzhen Guanri Technology Co., Ltd. Page 12 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

After above steps, right click on the Repeater name from Site List, then select Local RS232 for Communicate
Mode, and select the correct COM Port for Serial Port. And then click OK.

e. Right click on the Repeater name from Site List, then select Get MOID.

Shenzhen Guanri Technology Co., Ltd. Page 13 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

When Get MOID successfully, there will display as below Prompt: Get moid list successfully

f. After get MOID, you can pick up the parameters of repeater as below:

a) Query the Repeater Info, choose the Repeater Info page, click the All button, then click Inquiry button.

Shenzhen Guanri Technology Co., Ltd. Page 14 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

b) Query the Monitor Info, choose the Monitor Info page, click the All button, then click Inquiry button.

c) Query the Alarm Info, choose the Alarm Info page, click the All button, then click Inquiry button.

Shenzhen Guanri Technology Co., Ltd. Page 15 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

d) Query the Alarm Enable, choose the Alarm Enable page, click the All button, then click Inquiry button.

If you need to disable alarm, you should tick the alarm which alarm needs to be disabled, then double click
Local Value and choose Disable. Then click Set button.

Shenzhen Guanri Technology Co., Ltd. Page 16 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

e) Query and set the RF Parameters, choose the RF Para page, click the All button, then click Inquiry button.
And you can set the gain directly of Downlink and Uplink. Double click the Local Value of Gain Down(ICS)
and Gain Up(ICS), and then input 40 to 70 according requirements.
Gain Down(ICS) CH1: Gain for UMTS2100 Downlink
Gain Up(ICS) CH1: Gain for UMTS2100 Uplink

For working bandwidth adjustable, we adjust the working bandwidth ( 5-15MHz Tune bandwidth) by set the
bandw idth and center channel number, For example: the work frequency band is
2125.6MHz-2139.8MHz (Bandwidth is 14.2MHz), so we should set the channel number 10664(center
frequency is 2132.7MHz) for Channel 1, double click the Local Value of Channel 1, input 10664. And set
14.2 for Band width CH1, double click the Local Value of Band width CH1 then input 14.2,final click Set
button. The adjust bandwidth is 5-15MHz Tune Bandwidth.

Uplink Frequency will automatically change with downlink Frequency.

Freq(WCDMA2100)=ChannelNumber/5

Shenzhen Guanri Technology Co., Ltd. Page 17 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

f) Query the RF Status, choose the RF Statues page, click the All button, then click Inquiry button, main RF
parameters are shown below, DL O/P is the output power of repeater.

Shenzhen Guanri Technology Co., Ltd. Page 18 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

VII. SERVICE AFTER SALE

Your satisfaction is our priority. Offering a quick and effective technical support, we always put the customer
first. Please don’t hesitate to contact us by the following ways if you have any questions.

SHENZHEN GUANRI TECHNOLOGY CO., LTD

Address: 3/F, Lifeng Building, 42# of Liuxian 1st Road ,Bao’an 71st District ,Shenzhen,China

Tel: +86-755-86023910, 26466353

Fax: +86-755-26495994

E-mail: [email protected]

Website: http://www.guanritech.com

Shenzhen Guanri Technology Co., Ltd. Page 19 of 20


UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual

UMTS2100 Bandwidth Adjustable Digital Pico Repeater User Manual (ATWS20E1)

Edition 1.0 (JAN 2017)

SHENZHEN GUANRI TECHNOLOGY CO., LTD.

All rights reserved.

Information in this manual is subject to change without prior notice

Shenzhen Guanri Technology Co., Ltd. Page 20 of 20