Fire and Gas Monitoring Panel
ST7-HV
ST7-HV
I NTRODUCTI ON TO THE ST7- HV SYSTEM
The ST7- HV syst em is a program m able PLC suit able for
safet y and securit y inst allat ions wit h a high t echnological
and econom ic cont ent t o ensure safety of people and
prot ect ion of asset s wit hin com m ercial and indust rial
environm ent s. This syst em is ideal for process plant s,
refineries, energy product ion fact ories, governm ent al and
public buildings, m ilit ary, naval inst allat ions and m any
m ore.
The ST7- HV syst em has st at e of t he art t echnology t hat
covers fire & gas det ect ion as well as CCTV and securit y
syst em s.
The ST7- HV syst em has been designed to m eet a variet y of
funct ions, reliabilit y and availabilit y requirem ent s which is
ideal for com panies t hat operat e in t he field of energy
product ion and t ransform at ion. The ST7- HV has excellent
resist ance t o elect rom agnet ic dist urbances and is capable of
cont inuous operat ion in difficult environm ent al condit ions.
I t s capacit y is set to t he com pliance wit h t he requirem ent s
of fault t olerance set by t he I nt ernat ional St andards I EC
61508. Due t o it s com pliance, it has obt ained t he level SI L3
( Safet y I nt egrit y Level 3) cert ified by a t hird party agency.
The ST7- HV syst em is cert ified t o perform m any prot ect ion funct ions. I t is in com pliance wit h t he applicable
regulat ions list ed in t he st andards for t he construct ion product s ( CPD & CPR) and in UL laborat ories t o m eet
t he corresponding US st andards.
Ext ernally, t he panel ST7- HV is sim ilar to a safet y PLC; it is com posed by elect ronic cards m echanically
com pat ible, which are insert ed in 19” racks. The panel ST7- HV can have from 1 t o 10 racks, each rack has 13
card slot s.
About 20 different cards can be used, each dedicat ed t o different funct ions such as firefight ing, gas det ect ion,
int ruder alarm , t echnologic cont rol and com m unicat ion wit h ot her syst em s and/ or panels. The ST7- HV panel
has a dedicat ed rack for t he operator’s int erface and it is const it ut ed by a big alphanum eric display, by a
keyboard and led indicat ions to show t he syst em st at us. Each panel ST7- HV has it s own m odular feeder and
bat t ery charger which allows the panel to work even wit hout an ext ernal power supply.
The ST7- HV syst em can com m unicat e wit h ot her panels of t he sam e t ype and wit h supervisory and SCADA
syst em s. This can be done using bot h propriet ary and st andard prot ocols, such as Et hernet TCP/ I P and
Modbus.
Special feat ures
• Hot backup redundant CPU’s
• Hot swap of all cards, including CPU’s, wit h aut om at ic reconfigurat ion
• Redundant and looped com m unicat ion bus bet ween cards and CPU’s
• Periodical aut om at ic t est ing of card input s and out put s
• Self- diagnost ics and signaling of card and CPU fault
• Aut om at ic safet y disabling of m alfunct ioning cards
Page 1 of 9
ST7-HV
APPLI CATI ONS OF THE ST7- HV SYSTEM
The ST7- HV syst em is com m only used for :
• Aut om at ic fire ext inguishing cont rol system s and in t he case of com plex firefight ing inst allat ion sect ioning.
This is in conform it y wit h t he Const ruct ion Product s Direct ive ( CPD) ;
• I nt egrat ed syst em s, including fire, int ruder/ burglar alarm , CCTV and t echnologic cont rol funct ions;
• Safet y & Securit y syst em s, where panels operat e as m ast er or slave unit s. Panels com m unicat e t hrough
net works ( of a fiber opt ic and fault t olerant t ype t oo) and are connect ed t o DCS or SCADA t hrough Modbus
prot ocol Et hernet and OPC Server;
• Fire prot ect ion wit h special logics t hat are in accordance wit h t he recom m endat ions of t he NFPA st andard;
• Gas det ect ion and m easurem ent syst em s. I t is ATEX- cert ifiable and capable of int erfacing wit h 4 & 20 m A
out put t oxic or explosive gas det ect ors.
All of t hese funct ions can coexist or be configured t o m eet specific cust om er requirem ent s.
SI L syst em s
The ST7- HV panel can be used t o produce syst em s cert ifiable t o SI L2 and SI L3. This is wit h t he requirem ent s
of t he applicable regulat ions that refer t o t he I EC 61508 and deriving st andards.
I n t hese applicat ions, t he ST7- HV plays t he role of logic solver so it represent s t he core of t he syst em and it
can obt ain t he SI L2 or SI L3 level depending on t he cards select ed to be used wit h it .
Clearly, to reach t he expect ed safet y level, t he field devices ( input s and out put s) m ust also be cert ified
accordingly, in addit ion t o t he panel.
Page 2 of 9
ST7-HV
According t o t he st andards, t he ST7- HV panel ( or syst em ) , can be considered a PES ( Program m able Electronic
Safet y-relat ed syst em ) and can be configured t o perform t he following safet y funct ions:
• Monit or digit al input s from field devices ( convent ional det ectors, pressure swit ches, release pushbut t ons,
select or swit ches, et c.)
• Monit or analogue 4- 20m A input s from field devices ( explosive gas, toxic gas, oxygen and heat det ect ors,
et c.)
• Elaborat ion of logics as a funct ion of input st at us ( including fire ext inguishing cont rol t o EN12094- 1)
• Cont rol act uat ors ( solenoids, relays, et c.) .
I n t he past , cert ified safet y funct ions were lim it ed only to processed applicat ions and gas det ect ion due to t he
sm all availabilit y of sensor and act uat ors on t he m arket t hat were SI L cert ified; now addressable flam e
det ect ors wit h t his cert ificat ion are highly available and aut om at ic fire ext inguishing com m and devices such as
solenoids for cylinders, deluge valves and fire m onit ors.
Page 3 of 9
ST7-HV
PARTI CULAR NOTES FOR SAFETY APPLI CATI ONS
There will always be t wo CPU’s.
A SI L- cert ified ST7- HV panel can cont ain different cards and perform different funct ions from t hose t hat m ust
be cert ified to SI L.
For whole syst em configurat ion, refer t o ST7- HV panel Safety Manual.
Should you have any doubt s, please cont act Silver- Tec t echnical service.
SI L 2 Configurat ion ( SI NGLE/ MONO) SI L 3 Configurat ion (REDUNDANT/ DUPLEX)
The I / O cards do not need t o be duplicat ed. I n case of aut om at ic fire ext inguishing cont rol,
sensors m ust be inst alled on two different det ect ion
The I / O cards not relat ing t o SI L2- cert ified safet y lines.
funct ions do not need t o be duplicat ed. The I / O cards concerning SI L3- cert ified safet y
funct ions m ust be duplicat ed in different racks.
Consequent ly, also t he racks are duplicat ed.
The redundant I / O cards m ust be evenly spread in
t he redundant racks.
Page 4 of 9
ST7-HV
ST7LAR&C- M ST7LAR&C- D
Det ect ion, alarm and cont rol from analogue input s Det ect ion, alarm and cont rol from analogue input s
( t ypical of gas det ect ors) ( t ypical of gas det ect ion)
ST7LDR&C- M ST7LDR&C- D
Det ect ion, alarm and cont rol from analogue input s Det ect ion, alarm and cont rol from analogue input s
( t ypical of fire det ect ors) ( t ypical of fire det ect ors)
ST7LDR&C- M ST7LDR&C- D
Det ect ion and aut om at ic ext inguishing cont rol Det ect ion and aut om at ic ext inguishing cont rol
according t o t he st andard EN 12094- 1. according t o t he st andard EN 12094- 1.
Page 5 of 9
ST7-HV
Com m unicat ion net work
ST7- HV is suit able for use in syst em s where several panels fully int eract on a network. They m ust ent irely
m aint ain t heir aut onom y in respect ive area cont rol.
Panels can com m unicat e wit h supervisory syst em s on an Ethernet LAN, and wit h ext ernal elem ent s ( e.g.
DCS, PLC, SCADA syst em s) via MODBUS RTU.
Com m unicat ion on a net work enables t he int egrat ion of different - vector syst em s, also including fault -
t olerant loop archit ect ures.
Page 6 of 9
ST7-HV
Sum m a r y of ST7 - H V syst e m
Charact erist ics of device m anagem ent & addressing
Mult iple input rack cards for collect ive lines; alarm t hreshold current values can be
Convent ional det ectors
adapt ed t o m ost det ect ors.
Addressable det ect ors and Loop rack cards, up to 127 addresses per loop; up t o 130 cards in panel version ST7-
devices HV/ 10R.
Support ed prot ocols and On t he sam e panel, cards wit h addressable loops belonging t o different brands and
addressable devices prot ocols can be used at t he sam e t im e
Rack cards for digit al I / O’s and analogue addressable I / O m odules on field bus; SSP
Technologic and I / O devices
propriet ary, up to 127 addresses per bus.
Rack cards, wit h one/ t wo 4-20 m A input s, for direct det ector connect ion and analogue
4- 20m A det ect ors
addressable m odules on field bus.
Gas det ect ors Rack cards wit h individual display and addressable m odules on bus.
Special rack cards ( ECD) * , cert ified for t his funct ion, wit h no logic and cont rol
Fire ext inguishing cont rol lim it at ion.
* = elect ric aut om at ic cont rol and delay device to EN 12094- 1
Special rack cards ( ECD) * , cert ified for t his funct ion, wit h no logic and cont rol
Fire ext inguishing cont rol
lim it at ion.
( direct ional valves)
Cert ified for 64 ext inguishing zones (ST7- HV/ 10R) .
Repeat er panels Addressable, on SSP serial bus, LCD display, 255 event - relat ed m essages.
Rem ot e cont rol PC wit h SI LVER- VI EW soft ware
Graphic m aps Silver- View int eract ive program , wit h different access levels and funct ions
St andard MODBUS RTU prot ocol; propriet ary prot ocol on Ethernet available upon
I nt erfacing wit h SCADA syst em
request .
Panel configurat ion Local and rem ot e, by m eans of PC and ProST7 program .
Com m unicat ion net work TCP/ I P on Et hernet , wit h com m unicat ion and consist ency cont rol.
Connect ion to ot her equipm ent Cards and MODBUS RTU protocol
Mult i- panel archit ect ure Et hernet and Modbus, copper of opt ic fibre.
Power supply
Several kind of feeder from 4 t o 20A are available and usable in parallel; all of t hem
are cert ified EN 54-4 and are in accordance wit h CPD / CPR
Feeder
Wit h fault indicat ion in case of m ains supply failure, bat t ery charger or bat t ery fault ,
overheat ing.
Can be coupled wit h feeder.
Bat t ery charge and aging st at us m onit oring, t hrough m icrocont roller-processed
Bat t ery charger
algorit hm ; t herm al com pensation during bat t ery charging; test ing but t on; bat t ery
capacit y < = 110 Ah.
Page 7 of 9
ST7-HV
Mechanic m odularit y and const ruct ion charact erist ics of t he panel
Cabinet wit h front door and swivel chassis for st andard 19” racks
• ST7- HV/ 1R for wall m ount ing L= 600 H= 700 P= 400m m
St ruct ure • ST7- HV/ 2R for wall m ount ing L= 600 H= 1100 P= 400m m
• ST7- HV/ 10R self- st anding L= 800 H= 2100 P= 400m m
Non- st andard panels can be produced, upon request , using different size cabinet s.
Front Acrylic glass door, lockable, wit h alarm swit ch.
By addit ion of 13- card slot racks; m axim um 10 ( + 1 base) racks, for m axim um 130
Expansion and rack cards.
Racks can be wired t o t erm inal blocks via flat cable, or cable wit h plug connect or.
There can be of t wo t ypes of t erm inal blocks:
t abbed t erm inal for DI N rail t erm inals and elect ronics ( cables up t o 4 m m 2) connect ed
Term inal blocks
t o rack cards using wired ribbon cable, or via t he t erm inals wit h elect ro- m echanical
cable assem blies and push- in connect or on t he rack.
Card inst allat ion Front plug- in, wit h locking screws.
Just change! ( no need t o eit her swit ch t he panel off or m ake changes to t he
Card & CPU replacem ent
connect ions and wiring) .
Card int erconnect ion Serial on rack backplane, and looped redundant bus, m anaged by FPGA.
Logic configurat ion of t he panel
Windows- com pat ible user- friendly program Silver- Pro enables t he configurat ion of:
• I / O st at us variat ions, expressed in AND/ OR logic gat es.
• Tim e and t im e period- based associat ions.
• Associat ions relat ing t o any input / out put int ernal t o t he panel.
• Associat ions and event s, or stat uses, relat ing to ot her panels on t he
net work.
Logics
• Dist inct logics for event s relat ing t o fire- fight ing, int ruder alarm and
t echnological cont rol funct ions.
• Special logics relat ing t o fire ext inguishing funct ions ( including direct ional
valve cont rol) .
• Vot ing logics 1oo2, 2oo2, or alike, conform ing to int ernat ional specificat ions
( ARAMCO and sim ilar) .
300 zones for area 1 ( fire) + 300 zones for area 2 ( int ruder and t echnologic cont rol
Zones alarm ) ; each zone can be at t ribut ed 99 input s, 99 out put s and 99 dist inct logic
associat ions.
Logics can be configured for int eract ion of panels on a net work, t he num ber of
Panel int eract ion
int erconnect ed panels being 99.
Once t he panel has been configured, a prot ect ion funct ion can be enabled, so t hat
m odificat ions can be m ade only by people in possession of a USB-port hardware key
and a com pat ible code.
This funct ion, whose enabling is at Custom er’s discret ion, prevent s unaut horized
Prot ect ion m odificat ions aft er t est ing.
Page 8 of 9
ST7-HV
Elect ronic m odularit y
LCD, LED ret ro- illum inat ed, graphic t ype, wit h t hirt y 52- charact er lines; can display
Display
event s concerning ot her panels on t he net work.
- ST7- CP1101- N CPU Rj 45
Main or secondary CPU ( Hit achi, 32 bit s, wit h int ernal operat ing syst em ; int egrat ed wat chdog; 4 MByt e Dat a
Mem ory SRAM + 2 MByt e Program Mem ory on Flash Eprom , 2 RS 232 port s + 1 port
Et hernet 10/ 100 base TX per CPU) .
- Display + keyboard ST7- ST7- DU1001- N
- Default input s/ out put s ST7-FT3001
Cards in base rack
- Default repet it ion FT3201- N ( t erm inals) or FT3101- N (relays)
- Back Plane BP1301- N
- BP1401- N Rack backplane ( flat cable)
- BP1402- N Rack backplane (plug cable)
Cards in each addit ional rack
- RC1201- N Rack cont roller
- BL0000- N Blank card ( em pt y slot s)
- FT3201- NTerm inal block m odule, 16 t erm inals
- FT3104- N - 1Term inal block m odule, 8 t erm inals
- PC2001- S Plug cable, 16 wires
- PC2001- R Double plug cable, 16 wires, for redundant applicat ions
- PC2101- S Plug cable, 2 wires
- PC2101- R Double plug cable, 4 wires, for redundant applicat ions
- PC2201- S Plug cable, 8 wires
- PC2201- R Double plug cable, 8 wires, for redundant applicat ions
Card t erm inat ion
- PC2301- S Plug cable, 4 wires
- PC2301- R Double plug cable, 4 wires, for redundant applicat ions
- PC2401- S Plug cable, 6 wires
- PC2501- S Plug cable, 4 wires
- PC2501- R Double plug cable, 4 wires, for redundant applicat ions
- FT3103- N Term inal block card, 8 volt age- free relays
- FT3102- N Term inal block card, 16 volt age-free relays
- FT3104- N Term inal block card, 4x2A out put s, polarit y reversing, for OC6201- S
- ST7-I C4001 Eight input s, convent ional det ect ion
- ST7-I C5001 One 4- 20 m A analogue input
- ST7-I C5002 Two analogue input s
- ST7-I C5003 Eight analogue input s
- ST7- OC6001 Eight 500 m A m onit ored out put s
- ST7- OC6101 Sixt een open collect or out put s
- ST7- OC6201 Eight polarit y reversal- m onit ored out put s
- ST7- OC6002 Four m onit ored out put s
Cards in expansion racks
- ST7- EX9001 Fire ext inguishing cont rol ( EDC) , cert ified to EN12094- 1
- ST7- LS9002 Special logic cont rol
- ST7- AL7001- S Addressable analogic loop cont rol DCP ( UL)
- ST7- AL7002- S Analogue addressable loop cont rol, ESP prot ocol
- ST7- AL7003- S Analogue addressable loop cont rol, SSP prot ocol
- ST7- AL7004- S Analogue addressable loop cont rol, Apollo prot ocol
- ST7- MD8001- N MODBUS RTU card
- ST7- AL7005- S Addressable bus cont rol, Syst em Sensor prot ocol
Page 9 of 9