We hereby Summary of Inspection Report that the following item(s) have/has been fully inspected
accordance to stipulations of:
1. Latest API Specification –6A,
2. The Applicable PT. Mitra Katup Nusantara Procedures & Specification,
No. Qty Serial Number Description of Equipment
1. 1 Set n/a - Sec A Box #01 (Wellhead Casing Head Assembly)
1. 1 Set n/a - Sec A Box #02 (Wellhead Casing Head Assembly)
1. 1 Set n/a - Sec A Box #07 (Wellhead Casing Head Assembly)
3. 1 Set n/a - Sec C Box #01 (X’Mas Tree Assembly)
4. 1 Set n/a - Sec C Box #02 (X’Mas Tree Assembly)
All Equipment of Wellhead are ready to be prepare for 3 Well site, after onsite redress.
Our recommendation for all the Wellhead & X’Mass tree :
1. Redress Inside Diameter of Casing Head, sealing area had pitting condition
2. Redress Inside Diameter of Tubing Spool, sealing area had pitting condition
3. Have to replace all the Rubber Seal because already out of date
4. All gate valve need to be greasing, to make stem packing better movement
5. All Adjustable Choke need to be greasing, to make stem packing better movement
In completeness the aforementioned, we herein have attached the supporting document(s) as
received evidence for this release: