Sdonglea-03 Quick Guide (4G) : Communication Scenario
Sdonglea-03 Quick Guide (4G) : Communication Scenario
Document Issue: 14
Part Number: 31509550
Release Date: 2022-02-24
The information in this document is subject to change without notice. Every effort has been
made in the preparation of this document to ensure accuracy of the contents, but all statements,
information, and recommendations in this document do not constitute a warranty of any kind,
express or implied.
• SDongleA-03 Smart Dongle (the "Dongle" for short) is a smart communications expansion
module that works with Huawei inverters to implement wireless communication between
inverters and management systems through the 4G network.
• When multiple inverters are cascaded, only one Dongle or one SmartLogger is allowed.
1 Communication Scenario
RS485 communication scenario
App
Slave inverter n Slave inverter 1 Master inverter
Management system
• In the networking, the inverter where the Dongle is installed is the master
inverter, and other inverters are slave inverters. Slave inverters can
communicate with the Dongle through cascading.
• This document uses the RS485 communication scenario as an example. For
details about the MBUS communication scenario, see the user manual.
• This document uses connection to Huawei FusionSolar Smart PV
Management System as an example. For details about connection to a
third-party management system, see the user manual.
• The inverter model is subject to change without notice. The model User Manual
information and device appearance in this document are for reference only.
For more details, see the user manual.
• The number of devices that can be cascaded varies with the Dongle model. You can view
the maximum number of devices that can be connected to the Dongle from the label on
the external package.
• If cascaded inverters include a single-phase inverter or are connected to batteries, a
maximum of three inverters can be cascaded.
• If devices are connected to the RS485-2, RS485_2, or 485B2 and 485A2 ports of the main
inverter, the devices are not included as cascaded devices.
• You need to prepare a standard SIM card (size: 25 mm x 15 mm; capacity: ≥ 64 KB).
When connecting to Huawei FusionSolar Smart PV Management System, prepare a SIM
card based on the traffic requirements in the following table.
• Before installing a SIM card, you need to remove the Dongle from an inverter.
LED
ILO4H00001
Ensure that the AC or DC side of the inverter has been powered on.
3. Install the FusionSolar app. Perform the Setup wizard operations. If you have performed
such operations, skip this step. If not, you can scan the QR code below to obtain the app
quick guide which describes the Setup wizard operations.
• You can obtain SIM card parameters from the SIM card carrier. For more details about
how to use the app, scan the QR code to obtain related documents.
• To create multiple installer accounts for a company, log in to the app and then tap New
User.
LED
Remarks Description
Color Status
The Dongle is not secured or is not powered
N/A Off
on.
Yellow (blinking Normal
green and red Steady on The Dongle is secured and powered on.
simultaneously)
Normal
Dialing (duration < 1 min)
Blinking in a 2-second
If the duration is longer than 1 min, the 4G
cycle (on for 0.1s and
Abnormal parameter settings are incorrect. Reset the
then off for 1.9s)
parameters.
The dial-up connection is set up successfully
Normal
Blinking at long (duration < 30s).
intervals (on for 1s and If the duration is longer than 30s, the settings
Green
then off for 1s) Abnormal of the management system parameters are
incorrect. Reset the parameters.
Successfully connected to the management
Steady on
system.
Blinking at short Normal
The inverter is communicating with the
intervals (on for 0.2s
management system through the Dongle.
and then off for 0.2s)
Steady on The Dongle is faulty. Replace Dongle.
The Dongle has no SIM card or the SIM card is
Blinking at short in poor contact. Check whether the SIM card
intervals (on for 0.2s has been installed or is in good contact. If not,
and then off for 0.2s) install the SIM card or remove and insert the
SIM card.
The Dongle fails to connect to the
Red management system because it has no signals,
weak signals, or no traffic. If the Dongle is
Blinking at long reliably connected, check the SIM card signal
intervals (on for 1s and through the app. If no signal is received or the
Abnormal
then off for 1s) signal strength is weak, contact the carrier.
Check whether the tariff and traffic of the SIM
card are normal. If not, recharge the SIM card
or buy traffic.
No communication with the inverter
• Remove and insert the Dongle.
Blinking at long • Check whether inverters match the
intervals (red for 1s Dongle.
Blinking red and green for 1s) • Connect the Dongle to other inverters.
and green Check whether the Dongle or the USB port
alternatively of the inverter is faulty.
Blinking at short
intervals (red for 0.2s Normal The Dongle is being upgraded locally.
and green for 0.2s)
3 Performance Parameters
Basic Parameters
Installation Plug-and-play (applicable Standard SIM cards
SIM Card Type
Mode to inverters only) (25 mm x 15 mm)
Typical Power
Indicator LED 3.5 W
Consumption
Dimensions (W x Operating
130 mm x 48 mm x 33 mm –30°C to +65°C
H x D) Temperature
Net Weight 90 g Relative Humidity 5% RH to 95% RH
Ingress
Protection IP65 Storage Temperature –40°C to +70°C
Rating
4 Obtaining Documentation
You can obtain the latest version of this document by scanning the following QR codes.