0% found this document useful (0 votes)
130 views8 pages

2UBB005074 - Airduct Interface For EC Fanbox - C

1. The document provides instructions for disassembling an air duct interface. 2. It instructs to disassemble the 4 screws in the corners and 14 cap screws to remove the louver. 3. Keeping the 4 screws in the corners will allow removal of the air duct interface from the EC D500/D560 Fanbox.

Uploaded by

rizal arifin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
130 views8 pages

2UBB005074 - Airduct Interface For EC Fanbox - C

1. The document provides instructions for disassembling an air duct interface. 2. It instructs to disassemble the 4 screws in the corners and 14 cap screws to remove the louver. 3. Keeping the 4 screws in the corners will allow removal of the air duct interface from the EC D500/D560 Fanbox.

Uploaded by

rizal arifin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

1 2 3 4 5 6 7 8

A A
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. CNIAB
First angle projection. Original drawing made with Solid Edge. Set the correct scale factor when adding dimensions after DWG/DXF conversion.

B B
Disassemble the 4 screws

C Disassemble the 14 cap screws C

D D
Remove the louver

Keep 4 screws in corners


Keep the 4 screws
E (2 opposite side) E

Disassemble the 4 screws


The method how to make airduct interface
A.1 NEW CABINET ENCLOSURE

For EC D500/D560 Fanbox


2UBB005072

F Based on Prepared GUOCHAO WANG 4/9/2019 Title ACS580MV_Airduct interface Doc. des. Scale Form F
Customer Check. SHEN LUO 1/27/2021 Outline Drawing DIMENSION DRAWING A4
Appr. SHENGJIN YAO 1/27/2021 EC FAN BOX Resp.dept. MV Drives R&D Center Rev.ind. C (AP) Lang. EN
Cust. Doc. No. Project name HUASHAN Doc. No. Sheet 1
ABB Ref. No. Weight kg 0.000 kg DRIVES 2UBB005074 Total 8
A
1 2 3 4 5 6 7 8

A A
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. CNIAB

655
Air Duct > 601
Keep cap screws in four corners
A to fix the fan louver frame in
position and disassemble others;
First angle projection. Original drawing made with Solid Edge. Set the correct scale factor when adding dimensions after DWG/DXF conversion.

B B
Pay attention to avoid the
40

14x O 7 A interference with four cap


screws in two sides when
150

design the air duct

Air Duct > 353


411.5

C
Pay attention to avoid the C
interference with four cap
screws in two sides when
150

design the air duct

Pay attention to avoid the


40

D interference with top cover D


when design air duct
16.5

14.5 42 180 180 180 42


653 3

28.5
E A-A E
1:2
A.1 NEW CABINET ENCLOSURE

EC D500 fanbox duct interface


2UBB005072

F Based on Prepared GUOCHAO WANG 4/9/2019 Title ACS580MV_Airduct interface Doc. des. Scale Form F
Customer Check. SHEN LUO 1/27/2021 Outline Drawing DIMENSION DRAWING A4
Appr. SHENGJIN YAO 1/27/2021 EC FAN BOX Resp.dept. MV Drives R&D Center Rev.ind. C (AP) Lang. EN
Cust. Doc. No. Project name HUASHAN Doc. No. Sheet 2
ABB Ref. No. Weight kg 0.000 kg DRIVES 2UBB005074 Total 8
A
1 2 3 4 5 6 7 8

A A
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. CNIAB

761
Air Duct > 711
14x O 7 Keep cap screws in four corners
B to fix the fan louver frame in
position and disassemble others;
First angle projection. Original drawing made with Solid Edge. Set the correct scale factor when adding dimensions after DWG/DXF conversion.

B B
47.5

Pay attention to avoid the


B interference with four cap
screws in two sides when
design the air duct
160

Air Duct > 387.5


C Pay attention to avoid the C
448

interference with four cap


screws in two sides when
design the air duct
160

Pay attention to avoid the


D
interference with top cover D
45

when design air duct


18.5

13 89.5 185 185 185 89.5


3

30.5
760
E E
B-B
1:2
A.1 NEW CABINET ENCLOSURE

EC D560 fanbox duct interface


2UBB005072

F Based on Prepared GUOCHAO WANG 4/9/2019 Title ACS580MV_Airduct interface Doc. des. Scale Form F
Customer Check. SHEN LUO 1/27/2021 Outline Drawing DIMENSION DRAWING A4
Appr. SHENGJIN YAO 1/27/2021 EC FAN BOX Resp.dept. MV Drives R&D Center Rev.ind. C (AP) Lang. EN
Cust. Doc. No. Project name HUASHAN Doc. No. Sheet 3
ABB Ref. No. Weight kg 0.000 kg DRIVES 2UBB005074 Total 8
A
1 2 3 4 5 6 7 8

A A
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. CNIAB

26 906.5
First angle projection. Original drawing made with Solid Edge. Set the correct scale factor when adding dimensions after DWG/DXF conversion.

B
207 B

370

C C

27
D D

1200
E E

EC D500/560 Fanbox duct interface


A.1 NEW CABINET ENCLOSURE

Frontward for 6~11kV (R1~R6)


2UBB005072

F Based on Prepared GUOCHAO WANG 4/9/2019 Title ACS580MV_Airduct interface Doc. des. Scale Form F
Customer Check. SHEN LUO 1/27/2021 Outline Drawing DIMENSION DRAWING A4
Appr. SHENGJIN YAO 1/27/2021 EC FAN BOX Resp.dept. MV Drives R&D Center Rev.ind. C (AP) Lang. EN
Cust. Doc. No. Project name HUASHAN Doc. No. Sheet 4
ABB Ref. No. Weight kg 0.000 kg DRIVES 2UBB005074 Total 8
A
1 2 3 4 5 6 7 8

A A
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. CNIAB

37.2 906 197


First angle projection. Original drawing made with Solid Edge. Set the correct scale factor when adding dimensions after DWG/DXF conversion.

B B

702
C C

282.5
359.5

D D

E
1200 E

EC 560 Fanbox duct interface


A.1 NEW CABINET ENCLOSURE

Frontward for 3.3/4.16kV (R4~R6)


2UBB005072

F Based on Prepared GUOCHAO WANG 4/9/2019 Title ACS580MV_Airduct interface Doc. des. Scale Form F
Customer Check. SHEN LUO 1/27/2021 Outline Drawing DIMENSION DRAWING A4
Appr. SHENGJIN YAO 1/27/2021 EC FAN BOX Resp.dept. MV Drives R&D Center Rev.ind. C (AP) Lang. EN
Cust. Doc. No. Project name HUASHAN Doc. No. Sheet 5
ABB Ref. No. Weight kg 0.000 kg DRIVES 2UBB005074 Total 8
A
1 2 3 4 5 6 7 8

A A
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. CNIAB

26 906 407

570
First angle projection. Original drawing made with Solid Edge. Set the correct scale factor when adding dimensions after DWG/DXF conversion.

B B

28.5
C C

D D

1400
E E

EC D500/560 Fanbox duct interface


A.1 NEW CABINET ENCLOSURE

Frontward for 3.3~11kV (R7~R9)


2UBB005072

F Based on Prepared GUOCHAO WANG 4/9/2019 Title ACS580MV_Airduct interface Doc. des. Scale Form F
Customer Check. SHEN LUO 1/27/2021 Outline Drawing DIMENSION DRAWING A4
Appr. SHENGJIN YAO 1/27/2021 EC FAN BOX Resp.dept. MV Drives R&D Center Rev.ind. C (AP) Lang. EN
Cust. Doc. No. Project name HUASHAN Doc. No. Sheet 6
ABB Ref. No. Weight kg 0.000 kg DRIVES 2UBB005074 Total 8
A
1 2 3 4 5 6 7 8

A A
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. CNIAB
First angle projection. Original drawing made with Solid Edge. Set the correct scale factor when adding dimensions after DWG/DXF conversion.

B B

C 137 26 C
27

D D

( 1200 / 1400 )
E E

EC D500/560 Fanbox duct interface


A.1 NEW CABINET ENCLOSURE

Backward for 6~11kV (R1~R6) / 3.3~11kV (R7~R9)


2UBB005072

F Based on Prepared GUOCHAO WANG 4/9/2019 Title ACS580MV_Airduct interface Doc. des. Scale Form F
Customer Check. SHEN LUO 1/27/2021 Outline Drawing DIMENSION DRAWING A4
Appr. SHENGJIN YAO 1/27/2021 EC FAN BOX Resp.dept. MV Drives R&D Center Rev.ind. C (AP) Lang. EN
Cust. Doc. No. Project name HUASHAN Doc. No. Sheet 7
ABB Ref. No. Weight kg 0.000 kg DRIVES 2UBB005074 Total 8
A
1 2 3 4 5 6 7 8

A A
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. CNIAB

906
First angle projection. Original drawing made with Solid Edge. Set the correct scale factor when adding dimensions after DWG/DXF conversion.

B B

702

C C

126 37.2 359.5


282.5

D D

E
1200 E

EC 560 Fanbox duct interface


A.1 NEW CABINET ENCLOSURE

Backward for 3.3/4.16kV (R4~R6)


2UBB005072

F Based on Prepared GUOCHAO WANG 4/9/2019 Title ACS580MV_Airduct interface Doc. des. Scale Form F
Customer Check. SHEN LUO 1/27/2021 Outline Drawing DIMENSION DRAWING A4
Appr. SHENGJIN YAO 1/27/2021 EC FAN BOX Resp.dept. MV Drives R&D Center Rev.ind. C (AP) Lang. EN
Cust. Doc. No. Project name HUASHAN Doc. No. Sheet 8
ABB Ref. No. Weight kg 0.000 kg DRIVES 2UBB005074 Total 8
A

You might also like