Dry Cooler Outdoor Installation: 200-5775-CV-201 Overland Conveyor #1 Length: 6515m Lift: 146m Power: 2 X 6000kW
Dry Cooler Outdoor Installation: 200-5775-CV-201 Overland Conveyor #1 Length: 6515m Lift: 146m Power: 2 X 6000kW
Dry Cooler
Outdoor Installation
A A
from Sheet 169
XY XY
Run Command Run Command
270 271
YI YI
Running Brake Open Running
270 Command Unit A 271
Brake Open
IAH XY IAH Command Unit B
Overload Overload
270 265 271
XY
B 266 B
PT PT 200-5775-CV-201-CPS1
DO
DO
PI
KP1
C TT C
PI
PI
to Sheet 169
TE TI
Air Inlet Temp. #1
235A 235A
TE TI
Air Inlet Temp. #2
235B 235B
200-5775-CV-201-BR1M1 200-5775-CV-201-BR1M2
Pump Motor Pump Motor
D Hydraulic Brake System Hydraulic Brake System TE TI D
Air Outlet Temp.
235C 235C
TE TI
Winding Temp U
200-5775-CV-201-M1 236A 236A
Hydraulic Reservoir Overland Conveyor
Drive Motor #1
TE TI
Winding Temp V
236B 236B
200-5775-CV-201-BR1HT1 200-5775-CV-201-BR1HT2
Immersion Heater Immersion Heater TE TI
Winding Temp W
236C 236C
E ST SI E
Speed
237 237
SS SA
Over Speed
237 237
ZE ZA
Air Gap
268 268
HI XA
DI HS Cycloconverter Fault
Stop 242
298D 298D
1411 CUAJONE
Tolerances for ISO 2768 part 1/2 Tolerance classification Tolerances for ISO 13920 Tolerance classification
THIS DRAWING AND ALL INFORMATION ON IT IS machined surfaces N/A welded constructions N/A
THE PROPERTY OF THYSSENKRUPP INDUSTRIAL
SOLUTIONS (USA), INC. IT IS CONFIDENTIAL Surface Scale Weight kg
ISO 1302
200-5775-CV-201 AND PROVIDED FOR A LIMITED PURPOSE.
NEITHER THIS DRAWING NOR ANY PART OF IT Bill of Material
Material