اسئلة تحليلات الدوائر الكهربائية (شبكات كهربائية)
اسئلة تحليلات الدوائر الكهربائية (شبكات كهربائية)
Fig. (1)
2. If the reading of the two wattmeters is equal and opposite while measuring power in a
3 phase induction motor then the power factor of the load will be
a) Unity
b) zero
c) lagging
d) 0.5 leading
b) [ ]
c) [ ]
d) [ ]
Fig. (2)
b) In the circuit of Fig(3), if Vab = 440 10° , Vbc = 440 250° , Vca = 440 130° V,
find the line currents.
Fig(3)
Fig.(4)
Q3) For the circuit shown in fig.(5), 3-phase voltage with positive sequence, if the supply
voltage is 433V and W3 = 18749.45w, find:
1- The value of R.
2- The currents distribution in the circuit.
3- The reading of W1 and W2.
4- Draw the phasor diagram of voltages and currents. [ 12.5 Marks ]
page ( 2 of 3 )
IA1 10 Ω
W1
IA IA2 10 Ω
IB1
Fig.(5) W2
IB IB2 10 Ω
IC1
IC IC2
W3
R R
Fig.(6 )
b) For the two – port network shown in fig.(7), Z11=9Ω, Z12=6Ω, Z21=6Ω and Z22=12Ω,
find:
1- The ABCD parameters.
I1 R1 R2 I2
2- The value of R1, R2 and R3.
V1 R3 V2
Fig.(7 )
Q5: For the circuit shown in fig.(8), find the reading of all wattmeters , line voltages and
the value of X if W1= 6402 watt and W3= 9000 watt. [ 12.5 Marks ]
15 Ω
A W1 W3
15 Ω
Fig.(8) B W4
15 Ω
C W2
W5
W6
Xl Xl Xl
page ( 3 of 3 )