Digital Upgrade Mammography
Details
1724 · 2430 SENSOR
Parameter New 1724 MCA New 2430 MCA Unit
Sensor Type CMOS -
Scintillator CsI : TI -
Active Array 2384 x 3312 3312 x 4344 pixels
Active Area 170.9 x 231.0 231.8 x 304.0 mm2
2357 x 3280 3302 x 4264 pixels
165.0 x 229.6 231.1 x 298.5 mm2
Dimensions 267.5 x 194.5 x 14.2 253.7 x 327.5 x 14.2 mm
Digital Upgrade Mammography
Pixel Pitch 70 μm
AED (Auto trigger) Yes -
4.5(@1x1) 3.6(@1x1)
Frame Rate fps
14.9(@2x2) 12.7(@2x2)
A/D Conversion 14 bits
Energy Range up to 50 kVp
Saturation Dose > 350 (3,000 uGy) mR
Data Interface GigE -
Weight 1.4 2.2 kg
Xmaru W - System Requirements
THE MINIMUM SYSTEM REQUIREMENTS for THE RECOMMENDED SYSTEM REQUIREMENTS for
a proper execution of Xmaru W are as follows a proper execution of Xmaru W are as follows.
• CPU:Intel® Core™ i5(4th Gen) or higher • CPU: Intel® Core™ i5(8th Gen) or higher
• Main memory (RAM): 8GB or higher • Main memory (RAM): 16GB or higher
• Monitor Resolution: 1920 x 1080 • Monitor Resolution: 2560 x 1440
Rayence’s Global Networks
RAYENCE EUROPE RAYENCE JAPAN
Mergenthalerallee 77,657960, Eschborn, Germany 4F-B, Aiefu Yushima, 2-25-5, Yushima Bunkyo-ku, Tokyo, Japan
Tel : (49) 6196-9989-897 Tel : (81) 3-5812-4073 Fax : (82) 3-5812-4076 1724 · 2430 MCA
E-mail :
[email protected] E-mail :
[email protected] Wide Dynamic Range
Easy Upgrade
AEC control
Xmaru W
Wide Range for View
User Interface
Optimized Image Processing
RAYENCE HEADQUARTERS RAYENCE USA (MEDICAL)
14, Samsung 1-ro, 1-gil, Hwaseong-si, Gyeonggi-do, Korea 81 Ruckman Rd, Unit A,B Closter, NJ 07624, USA
Tel : (82) 31-8015-6245 Fax : (82) 31-8015-6300 Tel : (201) 585-0290 Fax : (201) 585-0293 www.rayence.com
E-mail :
[email protected]+ E-mail :
[email protected] Address (18449) 14, Samsung 1-ro 1-gil, Hwaseong-si, Gyeonggi-do
Phone 031-8015-6245 Product inquiry 031-8015-6431
© RYMKT2020
Digital Upgrade Mammography Digital Upgrade Mammography
1724 • 2430 MCA
1. Quality
Wide Dynamic Range Wide Range for View
Other SHEZON ShezON High resolution of 70µm Image processing algorithm
CMOS sensor specialized in Mammography Imaging system for mammography
provide quality image and quick acquisition. • Various image type (Film/CR FFDM)
• Maximized skin expression,
ShezON Automatic dose detection
• Image Quality Improvement by automatically detecting dose 1 2 3 4 5 6 7 8
• Low Dose – High sensitivity technology for Quality Image
• Over Dose – Optimized sensitivity technology for Image Loss prevention
Skin burn Without skin burn out
2. Easy
Easy 2
Easy Upgrade User Interface
Get the advantages of digital detector without replacing the existing mammography system 1) Simple Procedure 2) Nipple Align Premium option 3) QC Tool Premium option
• Compatible with currntly in use CR/Film
mammography system units
• Image quality that parallels high-end FFDM systems
•
• 17 x 24, 24 x 30 Size optimized for the systems
Preset Procedures Auto Nipple Position Image Quality Maintenance
3. Optimized
AEC control Optimized Image Processing
Optimization design considering the structure of mammography imaging system
Premium option
RCC LCC
• Easy and Fast Image Select with
Optimized AEC
Outstanding the x-ray transmission • Detail tuning of Image contrast &
• Prevention of patient overexposure sharpness with premium edit function
Others / 70mm² • System AEC calibration not required
AEC Area
• Easy to use AEC control for mammography
• Wider range of control
ShezON / 112mm²