FIN. GRADE 30” MIN. PAVEMENT 7 36" MIN METER BOX ASEM! WW 3 MIN (yP) / WATER MAIN SERVICE LINE MINIMUM 3O"DEPTH ON ALL SERVICE LINE INSTALLATIONS AND LINE SHALL BE EXTENDED A TYPICAL 3° BEHIND CURB, CORPORATION STOP SHALL BE INSTALLED AT MAIN AND CURB STOP AT_END OF SERVICE LINE, DIRECT TAP ON 6” AND LARGER O.LP. TAP SADDLE FOR ALL PVG PIPE AND 4” LLP, ALL SERVICE LINES SHALL BE 1 TYPE "kK" COPPER, SEAMLESS, SOFT TEMPERED, WHEN COPPER SERVICE LINE ARE TAPPED ONTO NON METALLIC MAINS, TRACER WIRE ON NON METALLIC MAIN SHALL BE WRAPPED AROUND TAPPING CORP. SEVERAL TURNS, ANYTHING THAT HAS TO BE REMOVED TO FACILITATE NEW CONSTRUCTION SHALL BE DELIVERED TO CENTRAL ARKANSAS WATER. CLEARWATER OPERATIONS CENTER INSTALL METER BOX ASSEMBLY 3° SEHIND CURB UNLESS: OTHERWISE DIRECTED BY C. A. W. (CITY AND COUNTY STREETS). INSTALL METER BOX ASSEMBLY WITHIN 1° OF R. 0. W. LINE, Bsa YE ae wor METERS SHALL BE SET PERPENDICULAR TO STREET WITH OUTLETS GOING TOWARDS THE HOUSE OR BUSINESS: WAN DETAIL #1 — ROM. METER LOCATION. WITHIN 1” OF PROPERTY CORNER HOUSE HOUSE | i i WANN ETA L #2 _— ROM. UNLESS OTHERWISE DIRECTED BY C. A. W. (FOR STATE HIGHWAYS). [eT eae MO RNER & ! HOUSE | (Howse, DUCTILE IRON BOX LID for 5/8" (SINGLE SETTER) \ rtm FIN. GR. for 1° METER —eOF z for 3/4” METER wy 3 . : + 3/4" COPPER FOR ® 3/82 3/4 SETTERS: COPPER FOR Ie Serress Se / PRIVATE. LINE Pu_X MIP CONNECTION ra HORZ. PU OUTLET 1" TYPE "Kk" cope * cuRB ‘OPPER Ba Sen STANDARD SINGLE M ETER BOX AND SETTING 01 Std, mtr set.dwg 2016 Revision METER BOX ASSEMBLY: 1 eae 7 FN. GRADE PaeveNT S30" mI oes 36" MIN. mn 1000 CORP. coxpy— 1" COPER | er me ™~ WATER MAIN SERVICE LINE STOP PJ X FIP- NOTE WIIMUM, 30°DEPTH_ ON ALL. SERVICE LINE. INSTALLATIONS AND NETERS SHALL BE SET PERPENDICULAR TO LINE SHALL SE EXTENDED A TYPIGAL 3 BEHIND CURD STREET ITH OUTLETS. CONG TOMAROS. THE HOUSE OR BUSINESS: CORPORATION STOP SHALL BE INSTALLED AT MAIN AND CURB STOP AT_END OF SERVICE LINE, DIRECT TAP ON 6" AND LARGER O.LP. TAP SADDLE FOR ALL PVG PIPE AND 4” D.LP, ALL SERVICE LINES SHALL BE 1” SEAWLESS, SOFT TEMPERED, DETAIL #1 TYPE "k” COPPER, Syerer LOCATION WITHIN WHEN COPPER SERVICE LINE ARE TAPPED ONTO NON. METALLIC METER LOCATION, WHIM MAINS, TRACER WIRE ON NON METALLIC MAIN SHALL BE i WARPED AROUND TASPING CORB. SEVERAL TURNS © ANYTHING THAT HAS 70. BE REMOVED TO FACILITATE. NEW Rouse] | (HOUSE GSKETRUCTON stats" 2e"BeLVERED 10" CENTRAL ARIANSAS WATER CLEARWATER OPERATIONS CENTER INSTALL METER BOX ASSEMBLY 3° BEHIND CURB UNLESS MAIN OTHERWISE DIRECTED By C. A. W. (CITY AND COUNTY STREETS). DETAL #2 —--—--—--— R.0W. INSTALL METER BOX ASSEMBLY WITHIN 1° OF R. O. W. LINE, ts UNLESS OTHERWISE DIRECTED BY C. A. W. (FOR STATE HIGHWAYS) ; METER LOCATION WITHIN K ). | 1" OF PROPERTY CORNER DUAL PURPOSE INLET t 36 [HOUSE 1 [HOUSE METER OK i ke sy" « — he 3s STRAIGHT “U" Raney TIME NWLET <3) we OUTLET rigyer 2 DUCTILE RON BOX LO 5/8" (DOUBLE SETTER) 578” (SINGLE SETTER) eter 3/4” METER J 5/8" x 3/4" Hon BoaL PURPOSE Serfen Bd X IP CONNECTION 3/4” FP. Lf eee ter ERT INLET- NS —— PRIVATE LINE ve curs — 3/4 Homz. PY OUTLET 34" coppeR FoR SroP' Bo x FP 5/8" & 3/4" SETTERS STRAIGHT "U" BRANCH 1" MIP INLET X3/4" MIP OUTLET ree xe _/ Ve 3/4 7 1/2 COPPER 5/8”, 3/4”, 1” STANDARD DUAL METER BOX AND SETTING O1B Dual Std mtr set.dng 2016 Revision CUT-OFF VALVE FLEXIBLE HOSE PRESSURE REGULATOR 150 — 250 PSI CHECK vaLvE 1/4" OUTLET FOR PRESSURE. GAUCE [7 Wale ae SuRGE OANPENING DEVICE STRAIGHT METER COUPLINGS: T/2°MIP X 3/4°FP FLEXIBLE HOSE ———= TO MAIN 5/8°WETER & PRESSURE GAUGE’ FURNISHED BY OWNER DISCHARGE SUCTION CONNECT TO CLEAR POTABLE WATER OR STRAINER IF USING = WATER SOURCE OTHER THAN CITY MAINS BASIC LAYOUT FOR TEST PUMP 1 SEE PAGE 26 FOR 1-1/2" AND 2" METER BOX AND LD X SEE PAGE 2A FOR ADDITIONAL INFORMATION ON SETTER PLACEMENT TOP OF 80x ' STEEL UD INLET To_BE SUPPLIED TO ACCOMMODATE 17 %4” L.L. METER | OUTLET . To a 2" ANGLE . . meet TP] vn ree ene NOTE: 2" METER SETTER — FORO H VV 77-128-11-77 SEE PAGE 2A FOR ADDITIONAL INFORMATION ON SETTER PLACEMENT 2° BRASS, OR COPPER 12" TO ADAPT 1 1/2" METER TO THIS SETTER, USE FORD A 67 PAIR ADAPTERS LOCKABLE 1" BALL VALVE c J 2 . 1" BRASS OR COPPER De 6S | - LIB 3 2" MIN. CLEARANCE ECR “—~ 6" OF CRUSHED STONE 2” FAP. THREAD —S 2° FLLP, THREAD METER SETTING FOR 1 1/2” & 2” METERS 150 P.S.l. WORKING PRESSURE 02 2in mtr set&test pump.dwg 2016 Revision 2A SUHLIN 42 ® .2/b—) YO4 NOILWTIVLSNI ONILIGS Y3L3N YO4 LNOAVT OISva Ldodans 3nwn, Jalodans Naa: OX, YY KX KK SONI GZOVENH “ATW X ‘Pd HLM ¥add09 7, IAL .Z YO SSvaa OUSENOG USdvIEHL MALIGS SIGN CNY NIVW N33MI3a TYRELWA CBZINVAIWS YO OAd ON “ios caeenisiann ONSE 08 Ssvwa CBQvRHIAZ (Hid3d YadO%d 139 O1 G3NINOIY HLONTT) SONILLIL 030¥38HL TW X a HUM aad09 A, 3AAL WZ 40 FlddIN Sv O3OVRUHLLZ (NIN) FlddIN SSVHE G3OVSSHL .9X,7Z OH “dtd WZ (nin) S1aaIN.ssvwa \ [ Q30VaYHL 9X2 —— TA N\ mun on 7aais xoa 40 doL NDIOOTE aa ASMYHL “ONOD BAL Odea¥ Yo | A5TNO “eT4.2/8 | Bloavs vais Tén0a ‘aN X ‘dT — TiedIN SSVUE KZ (147 Nado)(SaNa GaqvayHI) ANWA avo (SAYS .Z SONI O3QVMHL STW X Pd HLM Y3dd09 7, SdAL Z YO NIN .9 ~ FlddIN SSvMG CaqvaMHL,Z NIE 06 SSVYE O3OVIHL,Z ONILLAS YALAW 2 ONY .Z/1-b YO4 Z AOVd BAS 02k 1-1/2 & Zin mtr set.dng 2016 Revision METER BOX AND STEEL LID 10 BE 3 PROVIDED AND SET BY CONTRACTOR FN, omagg eke MIN, #04 fk x 2 ik 4 ence poe {F neeveo) SI ; YQ 3 FLaNse coupLNG sonore eastnc 5° oF masteo Su Se 2 MAIN ™, ROCK UNDER BOX (BP ccnacr83 . LECH AN “YEE OF METER La” Dl. FL. x FL. TO BE DETERMINED BY C.AW. Heep hive FL. ‘SPOOL PIECE * METER BODY TO BE SUPPLIED BY c faeBig i Ceew’ upon aPpRovat BF CAN ENGINEERING. 3" FLANGE COUPLING ADAPTER SMITHBLAIR 912 90" ELL, FL BYPASS TO BE 4” Dl ~S 4° FL. x FL. GATE VALVE 90" WITH ADJ. VALVE BOX J Ble x PE 3° LON 1 | ane SI ~ Fore te gpl x pL. | "FL. x FL. GATE VALVE TAPPING VALVE WITH “ADJ. VALVE BOX WITH ADU. VALVE BOX SE00 Pe ora 4° x 3" FL REDUCER 4" x 3" FL REDUCER 4 FL. x FL. GATE VALVE WITH ADJ. VALVE BOX 4° DL FL. TEE 3D. FL. x PLAIN END SPOOL PIECE 18" MIN. LENGTH NOTES: 1. ALL PROCEDURES, MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE SPECIFICATIONS OF CENTRAL ARKANSAS. WATER. 2. ALL DJ. PIPE & FITTINGS SHALL BE POLY WRAPPED. 3. ALL FITTINGS AND VALVES SHALL BE ALL PIPE SHALL BE OR P. , WITH FLANGE ADAPTER. 4. ALL VALVES SHALL OPEN RIGHT, EXCEPT FOR CERTAIN AREAS NORTH OF ARKANSAS RIVER WHICH SHALL OPEN LEFT. 5. METER BOX AND STEEL LID PER DETAIL PAGE 26 WILL BE PROVIDED AND SET BY CONTRACTOR. 6. UNI-FLANGES SHALL NOT BE USED. 7. IF FLANGE ADAPTERS (BEYOND THE ONE SHOWN) ARE USED, PLACE CONC. THRUST BLOCKING BEHIND AFFECTED TEES AND BENDS. QUANTITY METER SETTER PARTS DESCRIPTION a la" FLANGE XFLANGE RESILIENT SEAT VALVES 2 la FLANGED TEES 2 la" FLANGED 90 DEGREE BENDS 7 la" X74" DI FLANGED SPOOL PIECE 7 la" X36" DI FLANGED XPLAIN END SPOOL PIECE 7 la" X12" DIFLANGED SPOOL PIECE 1 la" X21" DIFLANGED SPOOL PIECE 1 IS" FLANGED COUPLING ADAPTOR “SMITH BLAIR 912 ONLY” 2 la" X3" FLANGED REDUCERS. 1 [3 X18" DI FLANGED SPOOL PIECE 1 [3 X18" DI FLANGED XPLAIN END SPOOL PIECE 76 la” FLANGE PACKS "BOLTS & GASKETS" 4 ls" FLANGE PACKS "BOLTS & GASKETS” 2 la” FLANGED 90 DEGREE BENDS (AS REQUIRED FOR FIELD CONDITIONS.) 2 la" FL XFL SPOOL PIECES (LENGTHS AS REQUIRED FOR FIELD CONDITIONS.) 05 3in mtr set.dwg 2016 Revision 3” TURBINE METER SET METER BOX AND STEEL LID TO BE 4 [ PROVIDED AND SET BY CONTRACTOR FIN. GRADE 19" MIN 4° Ok FL x FL. 20" MAX. 90" BENDS: (IF NEEDED) 4. FLANGE COUPLING ADAPTER EXIST. MT 1 NaN 8° OF WASHED, ROCK UNDER BOX (BY CONTRACTOR) LENGTH_AND TYPE OF METER TO BE DETERMINED BY C.AW. * METER BODY TO BE SUPPLIED BY AW. UPON APPROVAL BY C.AW. ENGINEERING. 4° FLANGE COUPLING ADAPTER SMITH-BLAIR 912 4 Ol FLL x FL. 40 DL FL x FL. ‘SPOOL PIECE TAPPING VALVE EXIST, MAIN x 4” TAPPING SLEEVE OR TEE BYPASS TO BE 4” D.. FL. 4" FL. x FL. GATE VALVE 90° WITH “ADJ. VALVE BOX 1 oN exist. I van | 90" ELL, FL ZL Ble FL x PE, 36" LONG 4” Ol. FL. TEE 4° FL, x FL, GATE VALVE WITH “ADJ. VALVE “BOX 4° Dil. FL. x PLAIN END SPOOL PIECE 4° FL. x FL. GATE VALVE. 20" MIN. LENGTH NOTES: WITH “ADJ. VALVE BOX Ne awrexe | METER BOX TAPPING VALVE WITH ADJ. VALVE 80X FL FL, 4° Di. FL. TEE 1. ALL PROCEDURES, MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE SPECIFICATIONS OF CENTRAL ARKANSAS. WATER. ALL D.l. PIPE & FITTINGS SHALL BE POLY WRAPPED, ALL FITTINGS AND VALVES SHALL BE FLANGED. ALL PIPE SHALL 8E ED OR P. E, WITH FLANGE ADAPTER. ALL VALVES SHALL OPEN RIGHT, EXCEPT FOR CERTAIN AREAS NORTH OF ARKANSAS RIVER WHICH SHALL OPEN LEFT. METER BOX AND STEEL LID PER DETAIL PAGE 26 WILL BE PROVIDED AND SET BY CONTRACTOR, UNI-FLANGES SHALL NOT BE USED. IF FLANGE ADAPTERS (BEYOND THE ONE SHOWN) ARE USED, PLACE CONC. THRUST BLOCKING BEHIND AFFECTED TEES AND BENDS. QUANTITY " METER SETTER PARTS DESCRIPTION (@” FLANGE X FLANGE RESILIENT SEAT VALVES: 4 FLANGED TEES FLANGED 90 DEGREE BENDS X74" DIFLANGED SPOOL PIECE X36" DI FLANGED XPLAIN END SPOOL PIECE 4" X12" DI FLANGED SPOOL PIECE # X27" DI FLANGED SPOOL PIECE 4” FLANGED COUPLING ADAPTOR "SMITH BLAIR 912 ONLY” X24" Di FLANGED SPOOL PIECE 4” X24" DI FLANGED XPLAIN END SPOOL PIECE ia” FLANGE PACKS "BOLTS & GASKETS” 4” FLANGED 90 DEGREE BENDS (AS REQUIRED FOR FIELD CONDITIONS) 4 FL XFL SPOOL PIECES (LENGTHS AS REQUIRED FOR FIELD CONDITIONS.) 4” TURBINE METER SET_ Zore Revision NOTES: 1. 2-INCH FILL CONNECTIONS ARE REQUIRED ON ALL MAINS, 12-INCH'S AND LARGER, OR AS DIRECTED BY C.AW. ENG. ‘INCH FILL CONNECTIONS SHALL BE USED ON ALL MAINS SMALLER THAN 12-INCH'S EXCEPT FOR MAINS WITH TEMPORARY END TO END CONNECTIONS OR AS SPECIFIED, 2. FULL SIZE CONNECTIONS WILL 8E ALLOWED ONLY WITH WRITTEN APPROVAL OF CW, THESE CONNECTIONS SHALL HAVE A VALVE BOX TO ACCEPT “TYLER 71%, LOCKING LID. VALVES SHALL BE OPERATED BY C.AM. PERSONNEL ONLY- ALL OTHER CONNECTIONS TO EXISTING FACILITIES SHALL CONTAIN A CHECK VALVE. 3. 2" BLOWOFFS ARE REQUIRED ON ALL MAINS 6” AND LARGER. 4, AFTER APPROVAL OF SAMPLES, CLOSE CORP STOPS AT MAIN AND REMOVE THE ENTIRE FILL ASSEMBLY UNLESS OTHERWISE DIRECTED BY THE ENGINEER. FOR 2" PERMANENT CONNECTIONS, CLOSE 2° VALVES, REMOVE FILL ASSEMBLY, AND PLUG COUPLINGS. TEMPORARY CONNECTIONS SHALL HAVE ALL PIPING REMOVED’ AT MAIN CONNECTION POINTS aND 2" VALVES PLUGGED. 5. 2" VALVES ON MAIN LINES SHALL BE |. 8. (R.S.) WITH THREADED ENDS; OPEN LEFT. 2” NIPPLES SHALL BE BRASS. oR 2” CORP. STOPS " VALVES ON MAIN LINES SHALL BE BRASS CORPORATION STOPS. ‘ALL 1" TAPS WILL BE BY DIRECT TAP METHOD, UNLESS PREVIOUSLY APPROVED BY CAW. EXCEPTIONS MAY BE: PRESSURE CLASS D.L, C-900, AND SDRI7 PVC, WHERE THE USE OF SADDLES MAY BE PERMITTED. OR 2" CHECK VALVE COMPARISON. / re POINT [- UNION (1 OPTIONAL) ‘SAMPLE POINT "OR 2" GATE OR BALL VALVE Flow |__1* coPPER oR 2" GALY. PIPING 17 VALVED COPPER OUTLET —18"' LONG (MIN.) WITH FLARED ENO. 1B'WIN TO “3O'MAX ABOVE GROUND GROUND SURFACE 2°18. GATE VALVE| Behe Ts PROPOSED MAIN METER BOX, W/LID_ ExISTING MAN / HERS eR CL ona tet Fok Fie BRA oI CURD STOP OR 2" COUPLING W/PLUG Rows ws, euue open 2 | —.., view ih MATEPEERE oo) TEMPORARY (END TO END) NOTE: EX. VALVE & PIPE TEMPORARY _(END TO END) NOSE af uviRGsttcatLy resreo PaOR (WO METER BOK REQUIRED) TORE WE SUNN LE Rar we SEE NOTE NO. to ( a 271... VALVE 3 on oe Cone 5 OR 1 = PROPOSED z van - exstne wh 7 3.0" MAX 8 20 un 28, vave H . | exisme ‘OR 2” CORP. BLOWOFF OR 1" cone EXISTING MAIN —_ oo tS pun yew T—EXISTNG ANCHOR COLLAR L_5.0" MAX __] INLINE N20" Mn oa stone ‘9 SEE NOTE NO. 2.9" TEE/TAP Og 1 oiRECT TAP LL ON DUP. ORT TAP 40 SEE NOTE NO. 2 +" SADDLE ON PVC 1”/_2” FILL CONNECTION DETAILS TYPICAL INSTALLATIONS 95 Fi cong 17 CURB STOP (CF. X Pd.) ——_} NOTE: TYPE."K" COPPER PIPE NEMoo oN 6" AND LAREN Ble rue ro WET Fence rox | 2, AP TAP, SADDLE, REQUIRED, FOR ALL Gr OTHER SUMTABLE” SUPPORT vetMn sora i, | GROUND _LEVEL | " PVC METER BOX AND LID ———! — TYPE "kK" COPPER PIPE — CORPORATION STOP (C.C. X P.v.) CORPORATION STOP (C.C. x P.J.) 2"—3" PVC MAINS MAINS 4” & LARGER: REMOVE RISER PIPE & INSTALL METER BOX W/LID WITHIN TEN (10) DAYS AFTER TAKING SAMPLE UNLESS OTHERWISE DIRECTED BY ENGINEER. 1” BLOW OFF / SAMPLE POINT ASSEMBLY 2° 6 GALY. 2'GAL. 90° BEND > Ss 18" METER BOX AND STEEL LID 30" TYPICAL 2° COUPLING-F.LP.T x LPT. W/2" PLUG 2°% 24"GALV. NIPPLE — MALP. X MALP. 2" .B.(RS.) GATE VALVE 2°% 6" BRASS NIPPLE — MIP. X MP. DOUBLE STRAP SADDLE W/2"F.P. OUTLET OR TAPPED TEE \ conc, THRUST BLOCKING CA. | __—2°oalv. 90" BEND 4 UNDISTURBED SOIL PO RS ARRAN BEND SUPPORT NOTES: VALVE SUPPORT ALL SADDLES, STRAPS ANO BOLTS SHALL BE POLYWRAPPED, WHEN TAPPING MAIN USE 1" BIT. 7% TAPPED TEES MAY BE USED ON CONNECTIONS TO NEW MAINS WHEN APPROVED BY OWNER. ALL THREADED OUTLETS SHALL HAVE A DOUBLE WRAP OF TEFLON TAPE, TEFLON PASTE OR RECTORSEAL ON THREADS. VALVE BOXES SHALL BE INSTALLED ON ALL BLOW OFF VALVES. AFTER TESTING AND STERILIZATION IS COMPLETE, 2” GALV. PIPING TO BE REMOVED AND 2” VALVE PLUGGED. RISER PIPE WILL GE PIPED INTO METER BOX AS SHOWN ONLY WHEN SPECIFIED. 2016 Revision __— ¥ caw. pee 7 TEE W/1" BRANCH OUTLET "Cp 18" LONG (MIN.) WITH FLARED END. 30” ABOVE GROUND (MIN.) TYPICAL (REMOVE AFTER TESTING/STERILIZATION) 18" METER BOX AND STEEL LID \30" TYPICAL 2” SAMPLE POINT ASSEMBLY . e—[wwew_w_eos_— 2" COUPLING-F.LP.T x FALP.T. W/2" PLUG 2° 24" GALV, NIPPLE — M.LP, X MLLP. 2'1.8.(R.S.) GATE VALVE W/VALVE BOX BRASS NIPPLE — MuLP. X MALP. SEA] Ms. TAPPED ™\ f DUCTILE IRON _(\t1)/ PIPE W/Md. BELL FIN. GRADE 2°CALV. PIPE | | aly. 90° BEND UNDISTURBED SOIL 2H MIN. 9” MAK ANCHOR COLLAR (SEE DETAIL) BEND SUPPORT VALVE SUPPORT NOTES: 1. 2" END BLOW OFF'S TO BE INSTALLED AT THE END OF MAINS 6” AND LARGER 2. A 1* COPPER BLOW OFF SHALL BE INSTALLED AT ON NEAR THE END OF EVERY MAIN NOT REQUIRING A 2° BLOW OFF. 3. ALL THREADED OUTLETS SHALL HAVE A DOUBLE WRAP OF TEFLON TAPE, TEFLON PASTE OR RECTORSEAL ON THREADS. 4 VALVE BOXES SHALL SE INSTALLED ON ALL BLOW OFF VALVES. 5. AFTER TESTING AND STERILIZATION IS COMPLETE, 2” GALV. PIPING TO BE REMOVED AND 2” VALVE PLUGGED. 6. RISER PIPE WILL BE PIPED INTO METER BOX AS SHOWN ONLY WHEN SPECIFIED. 2” END BLOW OFF ASSEMBLY 12MIN 18" METER BOX & LID 12"UN - 21" METER BOX & LID | GROUND SURFACE AI rel a VALMATIC_ 25.6 (exGk ONT x F.LP, THREADS) (SEE SPeciricarions) 1" CURB sToP (PACK JOINT F.LP. THREADS) J——— 1" Tye °K” COPPER PIPE 1" CORP. STOP (TAPERED THREADS x PACK JOINT) ALL 1" TAPS WILL BE BY DIRECT ‘TAP METHOD, UNLESS PREVIOUSLY APPROVED. EXCEPTIONS MAY BE: PRESSURE CLASS D.l., C-800, AND = SOR17 PVC, WHERE THE USE ‘OF note; MANUAL ‘AUTOMATIC SADDLES MAY BE PERMITTED. 1. ALL THREADED CONNECTIONS SHALL HAVE A DOUBLE WRAP OF TEFLON TAPE, TEFLON PASTE OR RECTORSEAL ON THE THREAD. 2. VALVES WILL BE PIPED TO POINT BEYOND PAVEMENT AND SHOULDER. 3. COPPER PIPE SHALL SLOPE CONTINUOUSLY UPWARDS FROM MAIN TO AIR RELEASE, —— 1" TYPE "k" COPPER PIPE 1" CORP. STOP 7 (TAPERED THREADS x PACK JOINT) ALL AIR RELEASE DETAIL 07 End blowotfé! air release.dwg 2016 Revision 90" BEND W/CLOSE NIPPLE == a | ar ne rae GROUND SURFACE 12 = 90° BEND 7 BRICK SUPPORT ON | COMPACTED SOIL > WE fo yave FILL W/SAND ° 4 * 2" COPPER 2" UNION, GALV. 2°% 6” BRASS NIPPLE VALMATIC_202¢.2 2-2" 90" BRASS BENDS —| ———— (SEE. SPECIFICATIONS) ‘SLOPE UP, \ . 2° 6" BRASS NIPPLE —— 2° 90° BEND, COPPER/BRASS BRICK SUPPORT ON COMPACTED SOIL. DOUBLE STRAP SADDLE — SECTION o—_ 2" 1.B. (RS.) VALVE W/B0x 2-INCH AUTOMATIC 24" BRASS NIPPLE ‘\ 2-2" 90" BRASS. BENDS- 1, ALL THREADED CONNECTIONS SHALL HAVE A DOUBLE WRAP OF TEFLON TAPE, TEFLON PASTE, OR RECTORSEAL ON THREADS. 2. DRILL HOLE IN SIDE OF METER BOX FOR OUTLET PIPING. 3. VALVES WILL BE PIPED TO POINT BEYOND PAVEMENT AND, SHOULDER. 4. PIPE BETWEEN 2” 1.8, VALVE AND AIR VALVE SHALL BE 2” TYPE "K" COPPER, SWEAT ON ALL FITTINGS, ADAPTERS, ELS, COUPLINGS, ETC. WITH 95-5 SOLDER, J 2° BRASS 90° DOUBLE STRAP SADDLE (SLOPE UP) PLAN 2-INCH AUTOMATIC (ROTATED 90") voc ons vox |] | 7 21" METER BOX & LID OF DUBUQUE IOWA 2.0'MIN. 1” cay, —| GROUND SURFACE NOTE: ALL 1" TAPS WILL BE BY DIRECT TAP METHOD, UNLESS PREVIOUSLY 90" PVC BEND XS PRESSURE. CLISS bl C200, AND vaunanic 2016.2 rt C800, ee eee eons) SORIT PVC, WHERE THE USE oF SADOLES way Se. PERMITED DRILL HOLE THRU 80x FILL W/SAND 1% "OUTLET (SIDE) W/', "CHECK VALVE UNION 1" CURB STOP (PACK JOINT x F.1.P. THREADED) —— 1" TYPE "kK" COPPER PIPE ” CORP. STOP (ee. XP) PLAN 1-INCH AUTOMATIC COMBINATION AIR VALVE DETAIL 08 Com air vac.dwg TT 2016 Revision =o oe FINISH GRADE __ 9” FINISH GRADE | 1 Lown . x{ sowax 1 | ® UST OF MATERIAL ® 1 Li 1. AST RON COVER i 2 Gash RON 98 secriON gl ob Shen Bru, eTON ° Fe Bee GEateNSIOn Plece, 18 fn t IF NEEDED.) COMPACTED SOIL * pe — ® 1s {3 remmin. 4 Notes 1. EXTENSION PIECE 1S. USED, ANOTHER VALVE BOX cOWPAGTED SOL SofTOW SECHON SHALL BE USED 2. EXTENSION PIECE CAN BE CUT TO LENGTH REQUIRED. = 3. USE SUP TYPE BOTTOM OR CUT THREADS OFF Ly Seen TYPE Son 4. IN UNDEVELOPED AREAS, CONSTRUCT A 2°X2'X0.5" TGR CLASS CONE” Sab aROUND THe TOP. OF THENATVE Box AENORCED wil Po REBAR PROVIDE VALVE STEM EXTENSION WITH CENTERING DEVICE IF GREATER THAN 5.0" DEEP, (PER C.AW. SPECIFICATIONS) VALVE BOX INSTALLATION [— ANCHOR COLLAR (SEE DETAL) [— Mw. TAPPED PLUG BRASS NIPPLE 12°LONG — MiLP_X M.LP. [— GATE VALVE 1.8. (R.S.) W/SCREWED ENDS. ANY APPURTENANCES —& ci re SN needa ce Md. DUCTLE IRON PIPE BRASS NIPPLE (iP. BEVEL)=6" LONG (OF ANCHOR COLLAR W/Md. BELL SUGSLE Bel COUPLING {| Ir V.C. CL 250 | ¢ ISunoistupae sol SRREEKRKERAY = 24 ww, ——+! ‘valve suPPoRT NOTES: 1, SIZE OF TAP, VALVE, AND PVC SHALL BE AS SHOWN IN THE CONSTRUCTION PLAN, 2. VALVE SHALL BE INSTALLED WITH VALVE BOX. 2”/3" PVC MAIN CONNECTION TO 6”AND LARGER MAINS 09 Val box&PVC conn.dwg 2016 Revision 10 £tben 7 2 1B. (RS) CATE VALVE (THREADED ENDS)(OPEN LEFT) 2°CL_ 250 PVC PIPE Lp» puctie IRON DOUBLE BELL COUPLING 2°X 4" BRASS NIPPLE (M.LP. X BEVEL) VALVE. SUPPORT 2°X 4" BRASS NIPPLE (M.LP. X MP.) Ie NEEDED) 2° THREADED —! FIP) BRASS TEE & VALVE DOUBLE STRAP SADDLE W/2"LP. THREADS OR TAPPED TEE i aes (BLOCK TAPPED TEES) (USE 0.0. CONTROLLED SADOLE ON P.V.C. PIPE) K CONCRETE THRUST BLOCK CONCRETE THRUST BLOCK 2” SERVICE CONNECTIONS — MAINS 4” AND LARGER DOUBLE STRAP SADOLE W/2".P. THREADS OR TAPPED TEE (BLOCK TAPPED TEES)(USE’0.D. CONTROLLED SADDLE ON P.V.C. PIPE) 2° |.B. (RS.) GATE VALVE (THREADED ENDS)(OPEN LEFT) 2°X 4"BRASS NIPPLE (M.LP.X BEVEL) 2" DUCTILE IRON DOUBLE BELL COUPLING (IF NEEDED) 2” |.B. (R.S.) IN-LINE GATE VALVE (THREADED ENDS)(OPEN LEFT) 2° DUCTILE IRON DOUBLE BELL COUPLING 2° DUCTILE IRON BELL PLUG (OR CAP) 2" 4" BRASS NIPPLE L /— (M.LP.X BEVEL) (IF NEEDED) 2” THREADED seer i aneee ‘ Gp) Biase tee VALVE 27 X 4" BRASS NIPPLE (WLP. X MIP) 2°CL_ 250 PVC PIPE CONCRETE THRUST BLOCK 2” SERVICE AND MAIN CONNECTION — MAINS 4” AND LARGER NOTES: 1. SADDLES, STRAPS AND BOLTS SHALL BE POLYWRAPPED. 2. WHEN MAIN TAPPED USE 17/8" BIT. (TAPPED TEES MAY BE USED ON CONNECTIONS TO NEW MAINS WHEN SPECIFIED), 3. VALVE BOXES SHALL BE INSTALLED ON ALL VALVES, 4. INSTALL CONTINUOUS INSULATED COPPER WIRE WRAPPED AROUND ALL PVC PIPES. 5. PROVIDE CONCRETE SUPPORT UNDER VALVES ATTACHED TO SADDLES. 10 Large mains 2sve con.dwg 2016 Revision 14 BRASS 2" TEE (W/ F.LP. BRANCH AND RUNS) [= AWWA LB. (R'S.) 2” GATE VALVE (OPEN LEFT) W/SCREWED ENDS W/VALVE BOX X 4" BRASS NIPPLE (M.LP.X BEVEL) [ 2° DUCTILE IRON DOUBLE BELL COUPLING 2°CL_250 PvC PIPE [ $e j — CONCRETE THRUST BLOCK 2" 4° BRASS NPRLE = MLE. ALLP DUCTLE IRON BELL 2” x 2” SERVICE AND MAIN CONNECTION HARCO D.|. TAPPED TEE (3" PUSH-ON x 2” FLLP.) AM.WLA. |.B, (R.S.) 2" GATE VALVE (OPEN LEFT) W/SCREWED ENDS W/VALVE BOX 2°X 4" BRASS NIPPLE (MJLP.X BEVEL) [~ 2" DUCTILE IRON DOUBLE BELL COUPLING 2°CL 250 PVC PIPE g — CONCRETE THRUST BLOCK L 2" DUCTILE IRON BELL 2" X 4" BRASS NIPPLE — MIP, X MALE. PLUG (OR CAP) CONCRETE THRUST BLOCK 3” x 2” SERVICE AND MAIN CONNECTION EXIST. MAIN SIZE VARIED DUCTILE IRON TAPPED TEE OR 3” TAPPING SADDLE (W/F.LP. BRANCH). AWWA, IB. (R.S.) 3” GATE VALVE (OPEN RIGHT OR LEFT AS DETERMINED) W/SCREWED ENDS W/VALVE 80X [——— 3° 4” BRASS NIPPLE (M.LP.X BEVEL) [ 3" DUCTILE IRON DOUBLE BELL COUPLING & JE—vawve supporr 3° X 4" BRASS NIPPLE — MILP. X MLLP. * Ole fon cary — PLUG (OR CAP) CONCRETE THRUST BLOCK 3°CL_250 PVC PIPE = 1 J — CONCRETE THRUST BLOCK 3” SERVICE AND MAIN CONNECTIONS NOTES: ‘ALL THREADED CONNECTIONS SHALL HAVE A DOUBLE WRAP OF TEFLON TAPE, TEFLON PASTE, OR RECTOR SEAL. 2. LAY COPPER TRACING WIRE WITH PVC PIPE, 11 2&3 sve con.dwa| 3. POLY WRAP ALL IRON FITTINGS, BOLTS, AND NUTS. 2016 Revision PROPERTY LINE, BUILDING 12 3.0" MINIMUM OR ANY OTHER OBSTRUCTION BURY LINE 3.0" MINIMUM ———| Sane BURY LINE enc aD 2X1" DEEP KEEP WT ROM, A W/HS. REBAR CONC aD We a eres, vave [| KEEP wy 0. a Ove 3e W/8Ox ORS ——! p-—s.o" »+—-+ 5.0 courage Shaw ANCHOR. TEE La oman 80d ba) Lal DRAIN BED—_| aE ‘STONE SLABS OR CONCRETE BLOCKS ==} STONE SLABS oR Z} CONCRETE BLOCKS 13" OR 17" SWIVEL ADAPTER 13" OR 17" SWIVEL ADAPTER CONCRETE THRUST * UNLESS OTHERWISE NOTED BLOCKING CONCRETE THRUST ~ BLOCKING ELEVATION VIEW / FLANGED OUTLET ELEVATION VIEW / STANDARD ANCHOR TEE CONCRETE PIPE — USE TANGENT FLANGE OUTLET. SIDE_OBSTRUCTION SIDE OBSTRUCTION 5,0'* -—so"-— 4.0" MIN 4.0" MIN r| i} i3| | PLAN VIEW PLAN VIEW STANDARD FIRE HYDRANT INSTALLATION TANGENT OUTLET USE ANCHOR TEE (UNLESS OTHER WISE NOTED) MAINS 16” AND LARGER NOTES: 1, DRAINAGE BED SHALL CONSIST OF CRUSH STONE OR COURSE GRAVEL WITH COURSE SAND. MINIMUM VOLUME OF 6 CU. FT. DRAIN BED SHALL EXTEND A MINIMUM OF 6" ABOVE DRAIN. OUTLET. 2. USE 6” Dl. NIPPLE WITH M.J. RETAINER GLANDS IF DISTANCE BETWEEN VALVE AND HYDRANT MUST BE GREATER THAN 17° SWIVEL” ADAPTER. 3. FIRE HYDRANT TO BE BLOCKED AGAINST FIRM SOIL AS SHOWN. 4. ALL HYDRANTS SHALL BE INSTALLED PLUMB. 5. LARGE NOZZLE SHALL FACE CURB UNLESS OTHERWISE NOTED. ROTATE BARREL AS REQUIRED. 6 7. HYDRANT SHOULD NOT BE SET CLOSER THAN 4.0" TO OBSTRUCTIONS THAT ARE IN LINE WITH NOZZLE. M.J. ANCHOR TEE OR TAPPING SLEEVE MAY BE USED (SEE MATERIAL SPECIFICATIONS) WHEN USING REGULAR M.J. TEE USE 13” SWIVEL ADAPTER NIPPLE BETWEEN TEE AND VALVE. 8. HYDRANTS TO BE SET AT DEPTHS GREATER THAN 6.0° SHALL BE SET WITH A MODIFIED FIRE HYDRANT SETTING. SEE DEEP BURY FIRE HYDRANT ASSEMBLY 9. POLY WRAP ALL PIPE, FITTINGS, BOLTS AND NUTS 10. FOR HYDRANTS NOT SET IN CONCRETE, PAVEMENT OR SIDEWALKS, A CONCRETE PAD SHALL BE CONSTRUCTED AROUND THE HYDRANT BARREL. CONCRETE PAD SHALL BE 2'X2°X1" DEEP, REINFORCED WITH ONE #5 REBAR ALL AROUND HYDRANT. STANDARD FIRE HYDRANT ASSEMBLY 12,PH,slenderd w_concis 2018 Revision STD, FIRE HYOT. 13 Dy -BaE 03 LD / So BB prone ou i) ry BURY LINE CONC PAD W/#5 REBAR BURY LINE 6°25. VALVE W/BOX & 6°RS. VALVE W/B0X_& x VALVE STEM EXTENSION VALVE STEM” EXTENSION in hea i i A 6.0" MAX, '2°x2"x1" DEEP Conc PAD W/#5. REBAR UNDISTURBED SOL 4 sone stass on | 45-60" TYP. CONCRETE BLOCKS THRUST BLOCK —> FRONT VIEW - 177 SvIVEL ADAPTER CONCRETE THaUST BLOGKING UNoIsTURBED } SOL 6" D.l. W/RETAINER GLANDS —ja| AND ALL THREAD, RODS (LENGTH AS REQ'D) unoisTuRBeD eA || be usaisturseo So . | 6° 90" MJ. BEND CONCRETE THRUST CONCRETE THRUST BLOCKING occ 17" SWIVEL ADAPTER 6°(R.S.) GATE VALVE 6" ANCHOR TEE/TAPPING SLEEVE NOTES: PLAN VIEW 1, DRAINAGE BED SHALL CONSIST OF CRUSH STONE OR COURSE GRAVEL WITH COURSE SAND. MINIMUM VOLUME OF 6 CU. FT. DRAIN BED SHALL EXTEND A MINIMUM OF 6” ABOVE DRAIN. OUTLET. 2. USE 6” Dl. NIPPLE WITH M.J. RETAINER GLANDS IF DISTANCE BETWEEN VALVE AND HYDRANT MUST BE GREATER THAN 17° SWIVEL” ADAPTER. 3. FIRE HYDRANT TO BE BLOCKED AGAINST FIRM SOIL AS SHOWN. 4. ALL HYDRANTS SHALL BE INSTALLED PLUMB. 5. LARGE NOZZLE SHALL FACE CURB UNLESS OTHERWISE NOTED. ROTATE BARREL AS REQUIRED. 6. 7. HYDRANT SHOULD NOT BE SET CLOSER THAN 4.0" TO OBSTRUCTIONS THAT ARE IN LINE WITH NOZZLE. M.J. ANCHOR TEE OR TAPPING SLEEVE MAY BE USED (SEE MATERIAL SPECIFICATIONS) WHEN USING REGULAR M.J. TEE USE 13" SWIVEL ADAPTER NIPPLE BETWEEN TEE AND VALVE. 8. POLY WRAP ALL PIPE, FITTINGS, BOLTS AND NUTS 9. FOR HYDRANTS NOT SET IN CONCRETE, PAVEMENT OR SIDEWALKS, A CONCRETE PAD SHALL BE CONSTRUCTED AROUND THE HYDRANT BARREL. CONCRETE PAD SHALL BE 2°X2'X1" DEEP, REINFORCED WiTH ONE #5 REBAR ALL AROUND HYDRANT. DEEP BURY FIRE HYDRANT ASSEMBLY 13 FH Deep bury.dws (BURY DEEPER THAN 6.0°) 2016 Revision proposes | | WATER MAINT REPLACEMENT ! SANTARY SEWER i| | sme. Senyce SECTION sek ine VARIES, He _. Heol with Il CONCRETE aon ttt VOINT OF DIP PRESSURE PIPE CENTERED ON NEW WATER MAIN NEW_WATER MAI PLAN EXISTING SANITARY SEWER SERVICE (IF NEEDED) 3/4" ANCHOR RODS (See Nore) - | | 90" BEND—_ MJ. B.S. TAPPING VALVE 3 14] EXISTING GRADE SY UNDISTURBED SOIL a EXISTING SANITARY SEWER SERVICE TO BE REPLACED WITH Dl. PRESSURE PIPE i WATER MAIN. BEDDING PER STANDARD C. A. W. CONSTRUCTION SPECIFICATIONS CAREFULLY comPacteo + clay BackFiL | SECTION AWA NOTE: SANITARY SEWER SERVICE REPLACEMENT SHALL BE SUBJECT TO LOCAL WASTEWATER AUTHORITY SPECIFICATIONS AND INSPECTION. IN CROSSING UNDER NEW WATER MAIN EITHER RIGHT OR LEFT (IF NEEDED) 2g“ AAGHOR Roos (SEE NOTE) CONC. THRUST: BLOCKING (F POSSIBLE) NIPPLE MINIMUM ' NEW WATER. MAIN 43 MIN, LENGTH 18" MJ. R.S. TAPPING VALVE(@) MJ. TEE OR MJ. OUTLET ON MAIN, OR TAPPING SADDLE WITH M.J. OUTLET SECTION VIEW > EXISTING MAIN] TAPPING SLEEVE CONC. THRUST TF BLOCKING, NOTES: 1. CONTRACTOR SHALL LOCATE EXISTING MAIN IN ADVANCE OF LAYING NEW LINE IN ORDER TO ASSURE ADEQUATE LENGTH TO ADJUST DEPTH OF NEW MAIN 2. DIMENSIONS SHOWN ARE RECOMMENDED MINIMUMS TO PROVIDE ADEQUATE ROOM FOR TIGHTENING BOLTS ON JOINTS. (OTHER DIMENSIONS MAY GE USED ) PLAN VIEW 3. USE TIE RODS IF ADEQUATE THRUST BLOCKING AGAINST UNDISTURBED SOIL IS NOT POSSIBLE 4. ALL TIE RODS AND NUTS FOR PERMANENT PLACEMENT SHALL BE SERIES 300 STAINLESS STEEL USE 3/4” RODS FOR 6" THRU 24”. USE 1" RODS FOR 30" THRU 36”. USE 1 1/4” RODS FOR 42" THRU 48". 5. RODS SHALL BE FIELD CUT TO FIT & SHALL BE PROTECTED WITH POLYWRAP, 6. ROTATE TEE UP & ELBOW DOWN AS REQUIRED TO MATCH. 225 PS| = = 3 ra = = = = = sehbs Sho Z[PIPE_SIZE 6 e [io] mo 20" [2a [30° se" | ae [ae STAINLESS \[RODS / NiPPLE[ 2 2 | 4 4 = [| 2 | 16 [| 78 [16 [20 STEEL SWING CONNECTION NEW MAIN TO EXISTING MAIN 14 Swing Con&Sew Cross.dw: 2016 Revision J SPACERS REQ'D FOR 4’ 1 aes (4" CARRIER PIPE & LARGER) 45, 30" 1 = oi mrerrereveouereneeay— 2" FEMALE UNION VARIES 6. Bune We ; WATER MAIN ) 7 OSA NGS BSS ALL AROUND THE ENCASEMENT PIPE SPOOL PE x FLO G0" MiNiMuM) WATER: MAIN q SSIS GROUT EXTERIOR COMPACTED EARTH ANCHOR COLLAR, W/2 MATS — "A (SEE DETAIL) cy | 15 NOTES: SPACER SHALL BE AS SPECIFIED IN THE MATERIAL SPECIFICATIONS IN THE FOLLOWING AMOUNTS: 4 EACH FOR 12” AND LARGER PIPE 3 EACH FOR 4° THRU 10” PIPE > PER JOINT OF PIPE PLACE SPACERS 2.0" FROM ENDS. WHEN CONCRETE PIPE IS USED, JOINT PROTECTION WILL BE AS SPECIFIED IN PARAGRAPH 16.8.2.4 OF THE CONSTRUCTION. SPECIFICATIONS, NOTES: ENCASEMENT VENTS PIPES SHALL BE MADE OF. 2-INCH GALV. AND SHALL BE CONSTRUCTED AS SHOWN. VENT PIPES SHALL BE INSTALLED PLUMB & WITHIN 6-INCHES OF THE RIGHT-OF-WAY. VENTS ARE REQUIRED UNLESS DELETED BY THE ENGINEER. ENCASEMENT ENDS SHALL BE SEALED WITH LINK-SEAL OR ‘APPROVED EQUAL. GROUT EXTERIOR ANNULAR SPACE AROUND ENCASENENT (PARAGRAPH 22.12 OF THE CONSTRUCTION SPECIFICATIONS. ENCASEMENTS, FOR MAINS 2-INCH_AND LARGER THAT GROSS R.O.W.'S CONTROLLED BY THE AHTD OR RAILROAD ‘SHALL HAVE VENT PIPE PLACED AT EACH RIGHT-OF-WAY LINE. VENT PIPES SHALL BE 2~INCH GALV. AND SHALL HAVE A C.AW. LABEL ATTACHED. (LABELS WILL “BE PROVIDED BY C.AW.) FOR CARRIER PIPES 4” AND LARGER 3/8” SERIES 300 STAINLESS STEEL CABLE SHALL BE SECURELY FASTENED TO THE LEAD END, OF THE WATER MAIN DURING INSTALLATION WITH A 3/8” CABLE CLAMP ‘AND SPIRAL WRAPPED AROUND WATER MAIN. AS PLACED THROUGH THE ENCASEMENT. ONCE THE WATER MAIN IS IN PLACE, THE 3/8” CABLE CLAMP SHALL BE REMOVED AND THE REQUIRED 10° OF ADDITIONAL CABLE ON EACH END SHALL BE WRAPPED AROUND WATER MAIN AND. SECURED INSIDE THE SEALED END. IF RESTRAINED JOINT WATER PIPE, DO NOT INSTALL CABLE, ENCASEMENT AND VENT REBARS 4.0" MIN. FLANGED BUTTERFLY VALVE (IF VALVE HAS SEAT ADJUSTMENT, PLACE TOWARDS REMOVAL SECTION). REMOVAL SECTION PIPE SPOOL, FLG X PE LENGTH = 2 PIPE DIAMETERS SOLID SLEEVE COUPLING WITH APPROVED. RETAINER GLANDS __ WATER MAIN PE. AS REQUIRED Ee —! 20° min, L NOTE: EXCAVATE TRENCH A MINIMUM OF 2.0" FEET EACH SIDE OF AND BELOW PIPE, TYPICAL BUTTERFLY VALVE INSTALLATION IN STRAIGHT RUN OF PIPE (16" AND LARGER PIPE) 2016 Revision 15. BF Valve&eEne det.dwa| NDISTURSED SOIL Ww oT ANCHOR COLLAR SCHEDULE 16 ¥ MINIMUM DIMENSIONS * REINFORCING BARS |ay petaner W H T THRUST COLLAR "A" BARS ["B” BARS | LANDS SHALL BE MEGA-LUG 15° | 2 2.0" | M.L. RETAINER GLAND 6 @ 6 @ 6” |--- 15° | 2. 2.0’ | M.L. RETAINER GLAND 6 @ 6 @ 6” |weto-on THRUST 20 | 4. 2.0' | M.L. RETAINER GLAND 6 @ 6 @ 6” [RING SHALL BE 3.0' | 4. 2.0’ | M.L. RETAINER GLAND 6 @ 6 @ 6" | DUCTILE IRON OR 35° | 5. 2.0’ | M.L. RETAINER GLAND 6 @ 6 @ 6" | STEEL 4.5) | 5: 2.0° | ML, RETAINER GLAND 7@ #7 @ 10” |Wetp ON THRUST 65' | 6.0' | 2.5" ]4.5" x 1.0" WELD-ON | #8 @ 8 @ 10” |InG SHALL BE 75) | 7. 2.5' |4.7" X 1.0" WELD-ON | #8 @ 8 @ 10” | desicneD FoR 3s’ | 8. 3.0'_|5.0" X_1.25" WELD-ON | #8 @ B_@ 10" | 950 PSI WORKING u PRESSURE AND UNDISTURBED SOIL W "x" BARS "B" BARS EA, DIAGONAL “A” BARS (LENGTH ANCHOR COLLAR (ELEVATION NoTE: PIPE SURFACES SHALL BE CLEANED OF ALL FOREIGN MATERIAL BEFORE CONCRETE COLLAR IS POURED. 72_HOUR CURE BEFORE PRESSURE APPLIED TO PIPE AND COLLAR. T NO INCLINE VALVE IN THIS SECTION: i FOR 24” OR SMALLER DUCTILE IRON PIPE, USE TWO (2) 375 PSI TEST PRESSURE, PIPE DIA. x 3.0) MEGALUG RETAINER GLANDS PLACED BACK’ TO BACK, FOR DUCTILE IRON PIPE LARGER THAN 24", DUCTILE IRON ‘OR STEEL ANCHOR RING TO BE SHOP WELDED TO PIPE. VALVE /APPURTENANCES —rrust LANL Mu. PLUG-+f DUCTILE IRON (Wi) PIPE rf E 3 W/W. BELL 2H MIN.-9" wax. "A°/"B" REBAR MAT ALL THREAD RODS FOR TEMPORARY RESTRAINT SIZE AND NUMBER AS Lv SPECIFIED BY ENGINEER Fr AC. PLUG OR zl cAB W/LUGS DUCTILE IRON PIPE (TOP VIEW conc rasust / BLOCKING FOR PERMANENT RESTRAINT L2H Mino" wax. — ASBESTOS CEMENT PIPE ANCHOR COLLAR DETAIL pe HRUST ANY APPURTENANCES 2H MIN FROM WALL ALWAYS PLACE DOUBLE A/a OF ANCHOR COLLAR MATS OF REINFORCEMENT CONC THRUST BLOCKING FOR | PERMANENT RESTRAINT [RESTRAINED PLUG OR, CAP 2H MIN.-9" MAX. CONCRETE PIPE—PRECAST KEY 16 Anc Col det.dwa| 2016 Revision NOTES: 7 1. NEW VALVE SHALL BE INSTALLED ONLY IF SHOWN IN THE CONSTRUCTION PLAN. 2. IF WATER MAIN. CAN BE TEMPORARILY SHUT DOWN, NEW INSERTED VALVE SHALL BE CUT IN BY CONTRACTOR. 3. IF WATER MAIN CAN NOT BE TEMPORARILY SHUT DOWN PRIOR TO CUT AND PLUG, NEW INSERTED VALVE SHALL BE INSTALLED BY C.AW. USING HYDRO-TAP METHOD. 4. SEE C.AW. STANDARD DETAILS FOR MINIMUM DIMENSIONS OF ANCHOR COLLAR. 10-0" FIELD VERIFY, NO_JONTS, FITTINGS, “SLEEVES, "AND/GR COUPLINGS IN THE AREA (e nea) cone, azouNo uscisTuRBED sot een vase SLRS idee ro Sgies 10 PIPE TO BE ABANDONED EXISTING MAIN SLEEVE \ J MuJ. SLEEVE ~ 12” LONG MIN. POSITION SLEEVE AND PLUG TIGHT AGAINST THE BRACING PIPE(S), STEEL PLATE, AND PIPE 10 BE ABANDONED BELLY THERE IS NO FLL aT OR NEAR THE POINT fo Se ue A SEaLYT OF Meaannoues Tae GUE, ISIC Gi THE APANRONED HE eae Ra i AGH GOLURS A ie RRSTETE es GET MING Gi oO ah SESE SEMEN Cr Ft PPE 08 SMALLER He i SASH TiCANRSS GeaEEL : Pier CoBe Aaa SOME OF Siacine PES SEAL END. OF IPE W/u. PLUC/CAP Soe eee MO OF NENG Exc Ree Te aie earscone STANDARD CUT AND PLUG DETAIL NO. 1 wis FED WER ONT FFENGS SLEEVES, AN/OR GOUPtNCS HY Tie ARES (F REQ’O) CONGRETE_ AROUND J oe SOIL NEW GATE VALVE- 4 eee (W/VALVE BOX) Mal. PLUG > INSERTED INTO AITACHED TO IPE TO BE ABANDONED EXISTING MAIN SLEEVE lel WATER MAIN TO REMAIN IN SERVICE J BELL Mu. SLEEVE — 12" LONG MIN, POSITION SLEEVE AND PLUG TIGHT AGAINST THE "H” BEAM AND CONC. ANCHOR COLLAR To See RR SE OME BERD I Si ncnce FOR 12" OR SMALLER PIPE, PLACE ONE(1) 8" WF. OR "H” BEAM, MIN. LENGTH OF 3.0", F 12" PIPE OR SMALLER, FOR 14” OR LARGER PIPE, NUMBER OF BEAMS, SIZE, IF 14" PIPE AND LARGER TORCH LL [BE NEEDED 10 wopiry IN’ FIELD. TO ACCOMMODATE PROTRUSION ‘OF BOLTS. NOTES: 18 1. NEW VALVE SHALL BE INSTALLED ONLY IF SHOWN IN THE CONSTRUCTION PLAN. 2. IF WATER MAIN. CAN BE TEMPORARILY SHUT DOWN, NEW INSERTED VALVE SHALL BE CUT IN BY CONTRACTOR. 3. IF WATER MAIN CAN NOT BE TEMPORARILY SHUT DOWN PRIOR TO CUT AND PLUG, NEW INSERTED VALVE SHALL BE INSTALLED BY C.AW. USING HYDRO-TAP METHOD’ 4. SEE C.A.W. STANDARD DETAILS FOR MINIMUM DIMENSIONS OF ANCHOR COLLAR. ANCHOR COLLAR AND TIE RODS, MJ. CAP OR PLUG IF NEEDED FOR TEMPORARY RESTRAINT. CONC ANCHOR OR CONC THRUST BLOCKING FOR PERMANENT THRUST RESTRAINT EXISTING PIPE TO BE ABANDONED. SEAL END OF PIPE W/CONC RETAINING GLAND OR 4” RING WATER MAIN TO REMAIN IN SERVICE 2 A f 7 12" PIPE AND SMALLER Ney Gare vaive SEAL END OF PIPE W/MuJ. PLUG/CAP W/ Yate B00) : | 14" IPE AND LARGER INSERTED INTO a EXISTING MAIN ; ) Sr SIZE, NUMBER, AND TYPE OF ALLTHREAD RODS TO BE DETERMINED BY C.AW. ENGINEER, POLY WRAP ALL EXPOSED IRON AND STEEL. TIE RODS ARE ONLY FOR TEMPORARY RESTRAINT WHEN MAIN. MUST BE QUICKLY RETURNED TO. SERVICE. TEMP. TIE RODS MAY BE CARBON OR STAINLESS STEEL. Sa} asicHOn COLLAS FELD. vERIPY_NO JONTS, FITTINGS, SLEEVES: AND/OR COUBLINGS IN’ BOUR 72 HOURS Tas ake ROO UN ALTERNATE CUT AND PLUG DETAIL TO BE USED ONLY UPON WRITTEN APPROVAL FROM CAW. NTS. WINIMUM UNDISTURBED SOIL BEND THRUST GLOcK SHALL BE NO Less THAN. 2 “MES THE HEIGHT (H) OF EQUIVALENT ANCHOR COLLAR RAR LISS. THRUST hRENCH wioTH 3 | (Excavation) eI UNDISTURSED. SUL THRUST MINIMUM LENGTH OR SPAN OF UNDISTURBED SOIL SHALL BE NO LESS’ THAN 2 TIMES THE VERTICAL HEIGHT (H) OF ANCHOR COLLAR MINIMUM UNDISTURBED SOIL BEHIND ANCHOR COLLAR / THRUST BLOCK 18 Alternate Cut & Plug LAN VIEW & Min Undisturbed Soil .dwg 2016 Revision ALLOWED BY C.A.W. ENG, CONG. ANCHOR COLLAR 9 AS PER STANDARD DETAIL, IN WRITING ONLY OVERSIZED AS NECESSARY ‘GROUND SURFACE, TO ANCHOR AGAINST THE APPLIED THRUST BY WEIGHT OF CONCRETE ALONE. REE Ate BLOCKING FOR TEE Me ORR Vay ANS Cy TYPICAL BLOCKING FOR VERTICAL BENDS SPECIAL BLOCKING OF TEE & PLUG (WHEN DIRECTED BY ENGINEER) car RY, TYPICAL SECTION OF CROSS & 2 PLUG BLOCKING FOR HORIZONTAL BENDS (WHEN DIRECTED BY ENGINEER) + ALTERNATE LOCATION IF {| FITTING LENGTH TOO SHORT TO 1 REINFORCING BARS ‘ACCOMMODATE 1} COLLAR St ote a8 Ma REDUCER TYPICAL, SECTION OF CROSS & PLUG BLOCKING ‘TWRUST SUPPORT FOR REDUCER (WHEN ‘DIRECTED GY ENGINEER) (SIZE 10 BE DETERMINED BY ENGINEER) NOTES ON THRUST BLOCKING 1. ALL BLOCKING SHALL BE AGAINST UNDISTURBED SOIL, 2. > WHERE SOIL CONDITIONS WAKE IT NECESSARY TO POUR CONCRETE OVER JOINTS, THE ENDS OF THE ADJACENT PIPES MUST HAVE A THRUST BLOCK TO RESIST MOVEMENT OF THESE JOINTS. 3. WEIGHT CALCULATIONS TO BE BASED ON THRUST DUE TO STATIC PRESSURE + 50% OR TEST PRESSURE, WHICH EVER IS GREATER. ( THRUST = 2AP 1/2 SIN WHERE A = AREA OF PIPE P = WATER PRESSURE ) WHEN BLOCKING AGAINST PLUG, PLUS SHALL BE COVERED TO PREVENT BONDING OF CONCRETE. WHERE SHEAR BECOMES A PROBLEM PROPER REINFORCING MUST SE INSTALLED INTO THE BLOCKING. CLEARANCE SHALL BE A MINIMUM OF 6” BETWEEN PIPE AND OBSTRUCTIONS. CLEARANCE ON PIPES BELONGING TO OIL/GAS COMPANIES SHALL BE 18” UNLESS SPECIAL PERMISSION IS GIVEN BY THESE COMPANIES, STANDARD THRUST BLOCKING 19, the * Blocking det.dwg| UNIMPROVED GRAVEL ROADS, STREETS, ALLEYS, DRIVEWAYS AND PARKING LOTS . 120} 2” HOT MIX 4 2 EINISH GRADE IF Exist. EZ 2 CONCRETE ie TT SURFACE concrerE W/SXEX6 te 4 WAM. CMIN.) see serun ee em] TWP. COVER ’ pw — Bey comPacteD eee CL7 STONE 4 apts s® OR CONCRETE I WHEN SPECIFIED = J___SEE NOTE 4 woot oF cur— NOTES: MATERIAL TO MEET OR EXCEED ARKANSAS HIGHWAY COMMISSION SPECIFICATIONS. REFER TO BEDDING & BACKFILL DETAILS FOR PVC PIPE BEDDING REQUIREMENTS WITH SAND OR #67 STONE. DO NOT PLACE CLASS 7 STONE AGAINST PVC PIPE; IF PVC PIPE ENCAPSULATE PVC WITH #67 STONE. PLACE 6"-9" OF SELECT GRANULAR RIVER SAND OR #67 STONE FOR ALL PIPE LAID IN HARD ROCK. PV: PAYABLE WIDTH FOR PAVEMENT REPAIR. ANY TRENCH WIDTH EXCEEDING PW DIMENSION IS A NON PAY ITEM, BUT MUST BE BACKFILLED AS PER DETAIL. TYPICAL SECTION OF REPAIR FOR UTILITY CUT ON STATE HIGHWAY DETAIL NO. 1 Pw (SEE NOTE 5) FC EXSTING FINISH GRADE 36"MIN, eau at mp. coven fos" tlt coMPACTED wey CL7 STONE eo FULL DEPTH Beg Ty . eek Lt : < SE wore 4 DETAIL NO. 5 MATERIAL TO MEET OR EXCEED ARKANSAS HIGHWAY COMMISSION SPECIFICATIONS. REFER TO BEDDING & BACKFILL DETAILS FOR PVC PIPE BEDDING REQUIREMENTS WITH SAND OR #67 STONE. DO NOT PLACE CLASS 7 STONE AGAINST PVC PIPE; IF PVC PIPE ENCAPSULATE PVC WITH #67 STONE. PLACE 6"-9" OF SELECT GRANULAR RIVER SAND OR #67 STONE FOR ALL PIPE LAID IN HARD ROCK. PW: PAYABLE WIDTH FOR PAVEMENT REPAIR AS DEFINED IN SECTION 39.3.20. ANY TRENCH WIDTH EXCEEDING PW DIMENSION IS A NON PAY ITEM, BUT MUST BE BACKFILLED AS PER DETAIL. 20.1 & 5 Rd detdng 2016 Revision NoTES: * WIDTH OF DITCH 21] EXCAVATION + 247% ROLL COMPACT ALL ASPHALTIC. CONCRETE FINISH GRADE EXISTING SURFACE CONCRETE W/6X6X6 WWM. ——_| pw HOT Mix asPHaLnc cone | |] FINISH GRADE IF_EXIST. cE CONCH srefnc. J | SURFACE. CONCRETE Laval : 36°MIN. 12 bea ee TYP. COVER —PW—l5 ote Fes * COMPACTED ea | SU Stone ef apcamsy " ] on concrete a: WHEN SPECIFIED {= Inia | < Z EE NOTE 4 1 wort oF cor— 12" MIN, UNLESS OTHER WISE SPECIFIED DETAIL NO. 2A CITY STREET ROLL COMPACT ALL wort oF Dc ASPHALTIC. CONCRETE EXCAVATION + 487 FINISH GRADE, CONCRETE W/6K6X6 WWM. —— |, EXISTING SURFACE ‘| HOT MIX ASPHALTIC CONC. — | FINISH GRADE IF_EXIST. 7 1 SURFACE CONCRETE f 36"MIN Tye. COVER comPacTeD CL7 STONE | | WIDTH_OF CUT 24” PLUS PIPE DIA DETAIL NO. 2B COUNTY ROAD 1 MATERIAL TO MEET OR EXCEED ARKANSAS HIGHWAY COMMISSION SPECIFICATIONS. REFER TO BEDDING & BACKFILL DETAILS FOR PVC PIPE BEDDING REQUIREMENTS WITH SAND OR #67 STONE, DO NOT PLACE CLASS 7 STONE AGAINST PVC PIPE; PLACE 6"-9" OF SELECT GRANULAR RIVER SAND OR #67 STONE FOR ALL PIPE LAID IN HARD ROCK, PV: PAYABLE WIDTH FOR PAVEMENT REPAIR. ANY TRENCH WIDTH EXCEEDING PW DIMENSION IS A NON PAY ITEM, BUT MUST BE BACKFILLED AS PER DETAIL, INCREASE EACH SIDE IN UNSTABLE SOIL CONDITIONS AS OR CONCRETE ale : WHEN SPECIFIED SEE NOTE 4 IF PVC PIPE ENCAPSULATE PVC WITH #67 STONE, DIRECTED BY THE ENGINEER. TRENCH WIDTH 12” AND GREATER IMPROVED COUNTY & CITY ROAD SURFACES 21 28&2B Rd det.dng 2016 Revision 2" HOT NIX ASPHALTIC CONC. ROLL COMPACT ALL ASPHALTIC CONCRETE q(T EXISTING FINISH GRADE iz * s*00NC, t CONCRETE W/SX6XE W.N.M : ely Ty] wes cover comPactep. ———-]- = .* é class 7 STONE tote g FULL DEPTH “ reer ait SEE NOTE 4 Notes DETAIL NO. 4A MATERIAL TO MEET OR EXCEED ARKANSAS HIGHWAY COMMISSION SPECIFICATIONS. REFER TO BEDDING & BACKFILL DETAILS FOR PVC PIPE BEDDING REQUIREMENTS WITH SAND OR #67 STONE. 00 NOT PLACE CLASS 7 STONE AGAINST PVC PIPE; IF PVC PIPE ENCAPSULATE PVC WITH #67 STONE. PLACE 6-9" OF SELECT GRANULAR RIVER SAND OR #67 STONE FOR ALL PIPE LAID IN HARD ROCK. PW: PAYABLE WIOTH FOR PAVEMENT REPAIR. ANY TRENCH WIDTH EXCEEDING PW DIMENSION IS A NON PAY ITEM, BUT MUST BE BACKFILLED AS PER DETAIL OPTIONAL: WHEN SURFACE IS ASPHALT OR SURFACE, TREATMENT, DELETE CONCRETE AND PLACE 6” OF HOT ASPHALTIC CONCRETE BASE COURSE LAID IN 2” LIFTS, COMPACTED. IMPROVED ALLEYS, DRIVEWAYS AND PARKING LOTS (ASPHALT SURFACE) * ONC. CONCRETE W/6X6X6_ W.W.M. / TRING Fist ome ey setun wiht Mw COMPACTED ————=} 88 ea oy TYP, POVER CLASS 7 STONE te so Pout ‘ocr Bey eae ay =n SEE NOTE 4 Notes DETAIL NO. 4B MATERIAL TO MEET OR EXCEED ARKANSAS HIGHWAY COMMISSION SPECIFICATIONS. REFER TO BEDDING & BACKFILL DETAILS FOR PVC PIPE BEDDING REQUIREMENTS WITH SAND OR #67 STONE. DO NOT PLACE CLASS 7 STONE AGAINST PVC PIPE; IF PVC PIPE ENCAPSULATE PVC WITH #67 STONE, PLACE 6"-9" OF SELECT GRANULAR RIVER SAND OR #67 STONE FOR ALL PIPE LAID IN HARD ROCK, PW: PAYABLE WIDTH FOR PAVEMENT REPAIR. ANY TRENCH WIDTH EXCEEDING PW DIMENSION IS A NON PAY TEM, SUT MUST BE BACKFILLED AS PER DETAIL, IMPROVED ALLEYS, DRIVEWAYS AND PARKING LOTS (CONCRETE SURFACE) 22 4AKAB Rd det.dwg 2016 Revision \22| 123] SURFACE MIN.COVER AS. SPECIFIED BACKFILL (SEE SECTION 26 OF THE CONSTRUCTION SPECIFICATIONS) 12" SELECT NATIVE MATERIAL, MAX. ROCK SIZE OF 2.5 INCH Select native WATER Wx Roe size OF 23" won | an COMPACTED SELECT 1/2 PIPE DIAMETER | TYPE 2 BEDDING | NATIVE, MATERIAL MAX. ROCK SIZE OF 2.5 INCH SURFACE MIN.COVER AS. SPECIFIED x7 BACKFILL (SEE SECTION 26 OF THE CONSTRUCTION SPECIFICATIONS) KA 12" SELECT NATIVE MATERIAL, MAX. ROCK SIZE OF 2.5 INCH COMPACTED SELECT NATIVE MATERIAL, MAX. ROCK SIZE OF 2.5 INCH PIPE BEDDED IN LOOSE NATIVE MATERIAL 4° LOOSE NATIVE MATERIAL, MAX. ROCK SIZE OF 2.5 INCH TYPE 3 BEDDING 6" MAX. COVER 3" MIN. COVER BACKFILL + (SEE SECTION 26 OF THE CONSTRUCTION SPECIFICATIONS) OR TYPE "x" BEDDING IF SPECIFIED IN. PLANS/BID ut 4° MIN, SUBGRADE (IF HARD ROCK TRENCH + SAND MEETING ASTM ¢ 144 (RIVER SAND) OR #67 STONE PLACE 6"-9" MIN. BEDDING & BACKFILL DETAILS PVC PIPE 23 Type 2&3&PVC Bed det.dag 2016 Revision [234] SURFACE | MIN.COVER, AS. SPECIFIEO | ous | TYPE 4 BEDDING 9” MIN. 9” MIN. MAX. | OF THE CONSTRUCTION SPECIFICATIONS) BACKFILL (SEE SECTION 26 OF THE CONSTRUCTION SPECIFICATIONS) 12" SELECT NATIVE MATERIAL, ROCK SIZE OF 2.5 INCH COMPACTED SELECT NATVE_ MATERIAL, MAX. ROCK SIZE OF 2.5 INCH CRUSHED STONE (SEE SECTION 27.5 SURFACE | MIN.COVER ‘AS. SPECIFIED 1/2 PIPE DiaWETER | SELECT NATIVE MATERIAL, MAX ROCK SIZE OF 2.5°INCH 1/2 PRE OWNETER | TYPE 4 (MODIFIED) BEDDING | OF THE CONSTRUCTION SPECIFICATIONS) ACKFILL (SEE_SECTION 26 OF THE CONSTRUCTION ‘SPECIFICATIONS) 12" SELECT NATIVE MATERIAL, MAX. ROCK SIZE OF 2.5 INCH CRUSHED STONE (SEE SECTION 27.5 SURFACE 9” MIN. BEDDING & BACKFILL DETAILS BACKFILL (SEE SECTION 26 OF THE CONSTRUCTION “SPECIFICATIONS) CRUSHED STONE (SEE SECTION 27.5 OF THE TYPE 5 BEDDING CONSTRUCTION SPECIFICATIONS) 23A Type 4&5&4 Modified Bed det.dwg 2016 Revision 24 3D conc. THRUST 0 [hee wate wan { ca wos L 90° BEND EXISTING MAIN existing unuy/| CROSSING over Of UNDER NeW Wate MAN 10" MIN. TO. REDUCE VERTICAL THRUST J, \ BLOCKING NC. THRUST TAPPING SLEEVE: a NEW WATER MAIN 90" BEND “CONC. THRUST NIPPLE , 18” MIN. LENGTH M.J. R.S. TAPPING VALVE NEW WATER MAIN, MIN. 36” COVER a SECTION VIEW NOTES: EXISTING UTILITY 1. CONTRACTOR SHALL LOCATE EXISTING MAIN IN ADVANCE OF LAYING NEW LINE IN ORDER TO ASSURE ADEQUATE LENGTH TO ADJUST DEPTH OF NEW MAIN. 2. DIMENSIONS SHOWN ARE RECOMMENDED MINIMUMS TO PROVIDE ADEQUATE ROOM FOR TIGHTENING BOLTS ON JOINTS. (OTHER DIMENSIONS MAY BE USED ) 3. USE TIE RODS IF ADEQUATE THRUST BLOCKING AGAINST UNDISTURBED SOIL IS NOT POSSIBLE. 4. ALL TIE RODS AND NUTS FOR PERMANENT PLACEMENT SHALL BE SERIES 300 STAINLESS STEEL. USE 3/4” RODS FOR 6” THRU 24”. USE 1” RODS FOR 30” THRU 36”. USE 1 1/4” RODS FOR 42” THRU 48". 5. RODS SHALL BE FIELD CUT TO FIT & SHALL BE PROTECTED WITH POLYWRAP. 6. ROTATE TEE UP & ELBOW DOWN AS REQUIRED TO MATCH 225 PS! = TT = = 7 7 = = sees! 30 7 PIPE SIZE 6 Bi o [12 | ie | 20" | 28 | 30 aa" | ae STAINLESS \[RODS / NIPPLE 2 2 | 4 4 a | i2 | 6 1 16 | 20 STEEL BACKSIDE TAP SWING CONNECTION 24 Backside Tap Swing Connection 2016 Revision 5] LOT UNE RIGHT-OF-WAY UNE, STREET cuRS ~ ied 2” & 3” SERVICE STREET CROSSING LOCATION FINISH SURFACE 48" MAX COVER es INSTALLED ON THE OPPOSITE SIDE OF THE STREET. SHARED TRENCH OPTION FOR WATER AND GAS MAINS 2” & 3” Street Crossing. dw TYPICAL SECTION 38 uty Shared trench Soe-dug 2016 Revision Manufacturer East Jordan Iron Works, Ine. P.O.Box 439 East Jordan, MI 49727 1-800-874-4100 Fax 231-536-4458 reoate COVER SECTION 5] custom Loco PRODUCT NO. 32143005RING ‘COVER - GRAY IRON ASTM AGS CL3SB BOTTOM VIEW LOAD RATING - NON TRAFFIC 21/8" 1-1/2", 2” METER BOX LID 32. 5/8" 20 7/16" in r —19 1/8" yo" ow 36cr HOLES . Four PLACES. 31 EQUALLY SPACED RING SECTION RING TOP VIEW 30" 1814 . 2.00" 28 1/4 HEX BOLT AT WASHER Sk WASHER Hex NUT Sues 24" propuct xo.38549224 4 TING GRAY IRON SASTM AM CL3SD BOX PLASTIC |___24 1/2 L ESTIMATED WEIGHT RING 63.88 30 PLASTIC BOX SOLES akg 28 11/16" _ > MISC PARTS “LB Ike BOX SECTION 1-1/2” METER BOX & LID RING 26 1.5 INCH AND LARGER METER BOX & LID & RING.dwg 2016 Revision BOXLOK VALVE BOX ALIGNMENT DEVICE TYPE NUMBERS nero | 2" | 3"| 4" a"| 10"| 12" we _|2 [2 [2 [2 lela [ss On cow [2 [2 [2 [2 [2 [2 |rcom xenneey [2 | 2 [2 [2 [2 [2 wan [2 [2 |[2fe lez fz wor |? 12 12 12 |2 le | ot watwous |? Pa fa ta fa [a US Pipe treton f+ fa fa fa fa fa fa US Pipe treo] 2 f 2 f2f2 fafa | 2 VALVE BOX ALIGNMENT DEVICE 75 Aor Oa an ie Nes VALVE INT DEVICE wm 2 ES SU Lak TED 1 Valve Box Alignment Device.dwg 2016 Revision THRUST BLOCK/ANCHOR COLLAR AS—BUILT RECORD FORM CAW PROJECT NO. : DATE AND TIME : JOB DESC : SUPV : COORD : PIPE DIA. & TYPE : TYPE OF FITTING LOCATION (STA. NO., INTERSECTION, FEATURE LOCATE) : TONS OF THRUST : SOIL TYPE *REQUIRED LOAD BEARING AREA (S.F.) : *(SEE OTHER SIDE FOR SAFE BEARING AREA TABLES) THRUST BLOCK AS—BUILT ANCHOR COLLAR AS—BUILT UNOWSTURBED SOL UNDISTURBED SOIL w ere, Peas, Foo 12 ob ‘STUNDARD. PLAN. ADOMONA. REQUREMENTS. NOTES ON THRUST BLOCKING ‘ALL BLOCKING SHALL BE AGAINST UNDISTURBED HAND DUG SOIL. WHERE SOIL CONDITIONS MAKE IT NECESSARY, TO. POUR CONCRETE OVER JOINTS, THE ENDS OF THE ADJACENT PIPES THRUST BLOCK TO RESIST MOVEMENT OF THESE JOINTS. WHERE SHEAR BECOMES A PROBLEM PROPER RENFORCING MUST OF INSTALLED INTO THE BLOCKING, CLEARANCE SHALL BE A MINIMUM OF 6” BETWEEN PIPE AND. OBSTRUCTIO IGE ON PPES BELONGING TO OIL/GAS COMPANIES SHALL BE 10" UNLESS SPECIAL PERMISSION 1S GNEN BY THESE: COMPRES, K: Safe Beai Press (25 tons /59. 1) Fiuing | PipeDia ee terrae 1 T "2 8457944 1s 1 ee nu 1 1 2 3 4 58 7 8 4 14 30° Sr ae es 90" 1 ee a Pug dead-end) | 1 Gees Ll Ct HAL Beating Area st 225 wre (G ons sq.) Fiting / PipeDia ett te) areata 1a a aaron 1s 1 5 2 8 4 5 7 8 4 4 nine 1 1 2 38 4 5 7 8 Hn 4 30° 1 PD oo eb ee Un as 1 1 2 3 5 7 4 % © 26 90° + 2 8 6 8 2 we FF Mee Vt ee JM SHALE or Safe Bearing At Biting / PipeDia 6 gt oe eg eee ar a. a 1 +2 $78 We 15 1 4 2 5 7 8 Hw nue oe 5 8 2 6 2% 30° fo 7 woo “as [ 2 3 a a ed so" 2 3 6 3 2 4 6 Plug (dead-end) | 1 2 4 2 oot SSE) SOFT SHALE, DRY SAND or LOAM Suzgested Safe Bearing Area at 225 psi TEST Pressure (@tone eq ft) Fiving / PipeDia 6 ttt aaa 1a 12348 1s ee nin ee i 30" ee er ase Sos ee OC 90° 3 5 8 6 2 6 57 ot tas Pade) | 2 8 7 & 8 © @ oF Tm te Bi Pressure (125 ons eq) Fitting / Pipe Dia 6a treme ie 1 1847814202428 1° ee ee nun Ce 6 ee ee 30° 266 ee ee ee 4s° 8 4 8 6 2 3 5 7 10s 199 90° 4 8 18 wk tas tw Pugdeate) | 3 5 12 2 tht tt cu (0.55 ons /9q 7.) Biting / PipeDia 6 tte se aa 1a 2288 a 486 1s oa Bm oF nin 7 4 6 2 om Ms 30° Go 2 tos a7 t02 o 5 8 2 te 217204 90" es a ee a ce Prog(dead-end) | 6 9 11 2 8 4520888

You might also like