Rotary Gas Meters
METER ANSI 125 FF WEIGHT
SIZE FLANGE A B C D1 D2 D3 D4 D5 D6 E1 E2 (lbs)
RM3000 2” 6.75” Ø 6.0” 5.58” 14.93” 16.36” 17.19” 18.13” 17.48” 17.53” 4.00” 4.00” 27-36
RM3000 - IMPERIAL
IMPERIAL RM3000 2” FLANGE CONNECTION
TECHNICAL SPECIFICATION
Connection (Flanged) ANSI 125 FF 2”
MAOP (psig) 175
Flow Capacity (cfh) 3000
Rangeability @ ± 1% Error 60:1
Rangeability @ ± 2% Error 100:1
Start Rate (cfh) 4.0
Stop Rate (cfh) 3.3
Differential @ 100% Flow (I.W.C.) 0.86
Instrument Drive Rate (cf/rev) 10/100
LF Pulser (Optional on Std Ctr) (cf/pulse) 10/100
CORRECTED FLOW CAPACITY AND TYPICAL ACCURACY GUIDE
RM3000 METER
(SCFH)
Gauge RM3000
Pressure
Qmax =
P.S.I.G.
0.25 3000ft3/hr
2 3136
5 3951
10 4969
15 5988
20 7006
25 8024
50 13116
75 18208
100 23299
125 28391
150 33483
175 38574
GAS METERS AND ELECTRONIC INSTRUMENTS The values quoted are typical of normal production.They do not constitute a specification. Romet
Limited reserves the right to change any information in this literature without notice. All of the
Phone 905-624-1591 USA 1-800-387-3201 information and data in this literature has been carefully compiled and thoroughly checked.
However, Romet Limited will not assume responsibility for any possible omissions or errors.
www.rometlimited.com • email: romet@rometlimited.com ROMET and ROMET & DESIGN are registered trademarks of Romet Limited. Romet Limited’s
gas metering technology is protected under U.S.Patent No.4,910,519 and 6,453,721 and
Canadian Patent No.1,293,568.
RM3000IMP 4/14