0% found this document useful (0 votes)
166 views1 page

Column Footing Details Mahantesh Nagar Site

This drawing shows column footing details for a building with ground plus four floors. The schedule lists the column numbers and their corresponding group for reinforced concrete footing sizes and steel reinforcement. Notes provide guidance on dimensions, concrete mix design, reinforcement grades and cover, lapping, and other construction details. The drawing is the property of the structural engineer and shall not be reproduced without permission.

Uploaded by

Girish Haragon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
166 views1 page

Column Footing Details Mahantesh Nagar Site

This drawing shows column footing details for a building with ground plus four floors. The schedule lists the column numbers and their corresponding group for reinforced concrete footing sizes and steel reinforcement. Notes provide guidance on dimensions, concrete mix design, reinforcement grades and cover, lapping, and other construction details. The drawing is the property of the structural engineer and shall not be reproduced without permission.

Uploaded by

Girish Haragon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

THIS DRAWING IS THE PROPERTY OF VINAY BEHERE, CONSULTING STRUCTURAL ENGINEER AND SHALL NOT BE REPRODUCED OR USED WITHOUT

EXPLICIT PERMISSION OF THIS OFFICE


NOTES
1- DO NOT SCALE THIS DRAWING.
2- THIS DRAWING SHOULD NOT BE USED FOR EXECUTION
SCHEDULE OF COLUMN FOOTING [VALID FOR G+4] UNLESS IT IS STAMPED AND SIGNED
TOP COLUMN BARS 3- ALL DIMENSIONS ARE IN FEETS & INCHES,
C1,C3,C4,C7,C11,C13 C2,C5,C6,C8,C9, 4-ARCHITECT /ENGINEER /CONTRACTOR SHALL CHECK ALL
LOWER COLUMN BARS DIMENSIONS & LEVELS BEFORE EXECUTION OF WORK.
COLUMN NOS C10,C12 5-DISCREPANCY IN DRAWING, IF ANY, SHALL BE BROUGHT
TO THE OUR NOTICE OR THE SITE ENGINEER, PRIOR
8TOR@6"C/C TO CONSTRUCTION.

GROUP 1 P FOR 2'-0" 6- NGL AT SITE = REFERENCE LVL.IS ASSUMED


GROUP 2 TO BE AT 0.000 FEET LEVEL
SIZE FIXING TIES CAN BE 7-GRADE OF CONCRETE MIX SHALL BE M:25
4TH SLAB REMOVED BEFORE AS PER IS :456:2000
ERECTING CAGE OVER
TO STEEL 8- MINIMUM CEMENT CONTENT SHALL BE OF
75 P/2 350 Kg/cum WITH AGGREGATE SIZE 20mm
TERRACE 9- REINFORCEMET STEEL SHALL BE GRADE Fe 500 FOR ALL
TIES STRUCTURAL ELEMENTS CONFORMING TO BS 1786-1989.
10- CLEAR COVER TO MAIN REINFORCEMENT SHALL BE
3RD SLAB SIZE AS FOLLOWS:-
SLOPE 1 IN 6 (MAX) WALLS=1" FOOTING =2"
TO EXTRA TIES @ COLUMNS=1.5" BEAMS =1"
STEEL
THE POINT OF BEND LOWER BARS CRANKED SLABS=0.75"
4TH SLAB INTO THE POSITION INSIDE 8TOR@6"C/C 11-FIRST STIRRUPS IN BEAM SHALL BE 50mm AWAY FROM
TIES UPPER BARS THE FACE OF SUPPORT.
FOR 2'-0"
12-WHEN BARS OF TWO DIFFERENT DIA. ARE TO BE
2ND SLAB SIZE
LAPPED,LAP LENGTH SHALL BE ON THE BASIS OF
SMALLER DIA. OF BAR.
TO STEEL 13- NOT MORE THAN 50% BARS SHALL BE LAPPED AT LAPPED
3RD SLAB , LAP POINT, LAPS SHALL BE STAGGERED PROPERLY.
TIES COLUMN & BEAM JOINT 15.- FOR BEAMS HAVING DEPTH MORE THAN 750MM PROVIDE

1ST SLAB SIZE 9"X21" 9"X24" COLUMN SPLICE DETAIL SIDE FACE REINFORCEMENT 12 # @ 200 C/C ON BOTH FACES.
16- LAP LENGTH FOR COLUMN -40 XD for M25 FE 500
LAP LENGTH FOR BEAMS/SLAB -50 XD for M25 FE 500
TO STEEL 8 NOS TOR 16 10 NOS TOR 16 17- DESIGN OF CENTRING, SHUTTERING, AND
Ld= DEVELOPMENT LENGTH CONCRETE MIX IS CONTRACTOR RESPONSIBLITY
2ND SLAB 18- SBC OF SOIL IS CONSIDERED 30T/SQMT
TIES 8TOR@8"C/C 8TOR@8"C/C BAR DIA TENSION COMPRESSION 19. DUE CARE SHALL BE TAKEN TO ASCERTAIN THAT REQUISITE

SIZE 9"X21" 9"X24" 6MM 291 233 6" 6"


STRENGTH OF CONCRETE IS GAINED BEFORE COMMENCEMENT
OF DESHUTTERING IT SHALL COMPLY WITH PROVISION OF
FOOTING 8MM 388 311 CLAUSE NO.11.3 OF IS 456: 2000
TO DESHUTTERING PEROID
STEEL 10 NOS TOR 16 12 NOS TOR 16 10MM 485 388 a) VERTICAL FORMWORK TO COLUMN, WALL AND BEAMS = 24 HRS
1ST SLAB 12MM 583 466
b) PROPS TO SLAB -14DAYS
TIES 8TOR@8"C/C 8TOR@8"C/C c) PROPS TO BEAM AND ARCH - 21 DAYS
16MM 777 621 NOTE- THE NUMBER OF PROPS LEFT UNDER,THEIR SIZES
& DISPOSITION SHALL BE SUCH AS TO BE ABLE TO SAFELY
FOOTING STEEL B' WAYS 12TOR@6"C/C 12TOR@6"C/C 20MM 971 777 PLINTH LVL. CARRY THE FULL DEAD LOAD OF THE SLAB,BEAM OR ARCH AS
25MM 1214 971 THE CASE MAY BE TOGETHER WITH ANY LIVE LOAD LIKELY
FOOTING DEPTH D 20" FLAT 24" FLAT TO OCCUR DURING CURING OR FURTHER CONSTRUCTION.
LAP LENGTH-50D STRUCTURAL CONSULTANT WILL NOT BE RESPONSIBLE FOR
FOOTING SIZE 6'-0"X5'-0" 7'-0"X6'-0" 8TOR@6"C/C 1- THE STABILITY OF STRUCTURE IF ANY CHANGES OR
MODIFICATIONS ARE MADE IN THIS DRAWING WITHOUT
THE WRITTEN CONSENT
P.C.C.SIZE 6'-6"X5'-6" 7'-6"X6'-6" 2- DRAWING RELEASED FOR 'APPROVAL' IS USED ON THE
SITE FOR CONSTRUCTION PURPOSE
10TOR@6"C/C

5'-0"
3- SAFETY OF ANY ARCHITECTURAL PROJECTION
L d+10 d b PROVIDED WHICH IS NOT GIVEN IN THIS DRAWING

QUALITY OF CONCRETE, QUALITY OF MATERIALS USED


FOR CONSTRUCTION,POOR WORKMANSHIP,
FAULTY CONSTRUCTION PROCEDURE

ANY ACCIDIENT OCCURING DURING CONSTRUCTION OF


STRUCTURE
ANY ACCIDIENT DUE TO INSUFFICIENT AND IMPROPER
L d+10 d b

15"
10TOR@6"C/C 15" SHUTTERING AND CENTERING WORK

STABILITY OF ADJOINING STRUCTURES


SETTELMENT OF BED CONCRETE

15"
Ld= DEVELOPMENT LENGTH Ld= DEVELOPMENT LENGTH CRACKS IN WALLS
IN TENSION CRACKS DUE TO SHRINKAGE OF CONCRETE
IN TENSION
d b= BAR DIAMETER
d b= BAR DIAMETER
10TOR @ 6"C/C
ANCHORAGE OF BEAM BARS
LAP, SPLICE IN BEAM IN AN EXTERNAL JOINT PCC 1:4:8 4"THK
ARCHITECT / ENGINEER
MR.VIJAY KALYANSHETTY
LIFT FOUNDATION DETAILS PROJECT: PROPOSED CONSTRUCTION OF RESI. APPT.BUILDING
FOR MR. ANGADI @

DRAWING TITLE
FOUNDATION DETAILS
DRN. : VARSHA CHD. : VINAY

8TOR@8"C/C
DRG. NO. : 21171/2R0 DATE : 11-05- 2021
8TOR@8"C/C 8TOR@8"C/C 8TOR@8"C/C
8TOR@8"C/C 8TOR@8"C/C
REVISION SIGN
COLUMN TIES FOR 8 BARS COLUMN TIES FOR 10 BARS COLUMN TIES FOR 12 BARS SR.NO. VINAY BEHERE M.E.
DESCRIPTION DATE
CONSULTING STRUCTURAL ENGINEERS
TEL-0831-4215890(O) 9448145890(M)
[email protected]