ELEMENTARY DIAGRAM
(UL APPLICATIONS ONLY)
LD10895
2 YORK INTERNATIONAL
FORM 160.73-PW3 (405)
LD10896
YORK INTERNATIONAL 3
FORM 160.73-PW3 (405)
ELEMENTARY DIAGRAM
(CE APPLICATIONS ONLY)
LD10897
4 YORK INTERNATIONAL
FORM 160.73-PW3 (405)
LD10898
YORK INTERNATIONAL 5
FORM 160.73-PW3 (405)
ELEMENTARY DIAGRAM
6 YORK INTERNATIONAL
FORM 160.73-PW3 (405)
YORK INTERNATIONAL 7
FORM 160.73-PW3 (405)
8 YORK INTERNATIONAL
FORM 160.73-PW3 (405)
YORK INTERNATIONAL 9
FORM 160.73-PW3 (405)
LEGEND
LD09000
10 YORK INTERNATIONAL
FORM 160.73-PW3 (405)
LD10915
NOTES:
1. This wiring diagram describes the standard electronic 10. For wiring diagram of V.S.D refer to product form
control scheme for use with a YORK V.S.D. for details 160.49-PW9.
of standard modifications, refer to Product Form 160.54- 11. A jumper is installed between terminals 24 & 25 for
PW7. normal operation.
2. Field wiring to be in accordance with the National CAUTION: The jumper is the only connection permitted
Electrical Code as well as all other applicable codes and between terminals 24 & 25 . Connections of any other
specifications. See Product Form 160.54-PW6 for field devices to either terminals 24 & 25 may cause inadver-
wiring connections. tent compressor start-up.
3. Numbers along the left side of diagram are line identi- 12. Stop contact on V.S.D logic board is set to trip at 105%
fication numbers. The numbers along the right side indicate FLA.
the line number location of relay contacts. An underlined
contact location signifies a normally closed contact. 13. Contact rating is 5 Amps resistive @ 250 Volts A.C. &
30 Volts D.C., 2 Amp Inductive (.4 PF) @ 250 Volts A.C.
4. Main control panel Class 1 field wiring terminal con- & 30 Volts D.C.
nection points are indicated by numbers within a rectangle,
i.e. 15 . Main control panel factory wiring terminal con- 14. Field connected control power supply is not required,
nection points are indicated by numbers within a triangle, as control transformer is supplied on the V.S.D.
i.e. 5 . Component terminal markings are indicated by 15. For high and low voltage units, the factory supplied
numbers within a circle, i.e. C1 . Numbers adjacent to jumper between 15 & 53 must be removed when elec-
circuit lines are the circuit identification numbers. tromechanical starter overloads and/or safety devices
5. To cycle unit on and off automatically with contacts are used. For high voltage (2300-4160) UL and CUL ap-
other than those shown, install a cycling device between proved units only. Elecromechanical compressor motor
terminals 1 & 13 (line 37) (see note 7). If a cycling starter overloads (normally closed) must be connected
device is installed, jumper must be removed between between 15 & 53 .
terminals 1 & 13 . 16. Each 115VAC field-connected inductive load: i.e. relay
6. To stop unit and not permit it to start again, install a coil, motor starter coil, etc., shall have a transient sup-
stop device between terminals 1 & 8 (Line 33) (see pressor wired in parallel with its coil, physically located
note 7). A remote start-stop switch may be connected at the coil. Spare transient suppressors and control circuit
to terminals 1 , 7 & 8 (Lines 32 & 33) (see note 7). fuses are supplied in a bag attached to green ground
Remote start-stop switch (Line 32) is operative only in screw in lower left corner of control panel.
the “remote” operating mode. 17. Resistor for use with Belimo actuator. Remove resis-
7. Device contact rating to be 5 milliamperes @ 115 volts tor if hot gas actuator is a Dodge Engineering, Bray or
A.C. Landis-Staefa actuator.
8. Contact rating is 5 Amps resistive @ 120 volts A.C. or
240 volts A.C.
YORK INTERNATIONAL 11
FORM 160.73-PW3 (405)
CONNECTION DIAGRAM
(UL APPLICATIONS ONLY)
LD10903
FIG. 6 – CONNECTION DIAGRAM (UL APPLICATIONS ONLY)
12 YORK INTERNATIONAL
FORM 160.73-PW3 (405)
LD10904
CONNECTION DIAGRAM (UL APPLICATIONS ONLY) (CON'T)
YORK INTERNATIONAL 13
FORM 160.73-PW3 (405)
CONNECTION DIAGRAM
(CE APPLICATION ONLY)
14 YORK INTERNATIONAL
FORM 160.73-PW3 (405)
LD10906
CONNECTION DIAGRAM (CE APPLICATION ONLY) (CON'T)
YORK INTERNATIONAL 15
FORM 160.73-PW3 (405)
CONNECTION DIAGRAM
16 YORK INTERNATIONAL
FORM 160.73-PW3 (405)
LD10908
CONNECTION DIAGRAM (CON'T)
YORK INTERNATIONAL 17
FORM 160.73-PW3 (405)
CONNECTION DIAGRAM
18 YORK INTERNATIONAL
FORM 160.73-PW3 (405)
YORK INTERNATIONAL 19
FORM 160.73-PW3 (405)
CONNECTION DIAGRAM
20 YORK INTERNATIONAL
FORM 160.73-PW3 (405)
YORK INTERNATIONAL 21
FORM 160.73-PW3 (405)
22 YORK INTERNATIONAL
FORM 160.73-PW3 (405)
LD10914
YORK INTERNATIONAL 23