B-65312EN - 04 Beta I Spindle Motor DESCRIPTIONS
B-65312EN - 04 Beta I Spindle Motor DESCRIPTIONS
DESCRIPTIONS
B-65312EN/04
• No part of this manual may be reproduced in any form.
• All specifications and designs are subject to change without notice.
The products in this manual are controlled based on Japan’s “Foreign Exchange and
Foreign Trade Law”. The export from Japan may be subject to an export license by the
government of Japan.
Further, re-export to another country may be subject to the license of the government of
the country from where the product is re-exported. Furthermore, the product may also be
controlled by re-export regulations of the United States government.
Should you wish to export or re-export these products, please contact FANUC for advice.
In this manual we have tried as much as possible to describe all the various matters.
However, we cannot describe all the matters which must not be done, or which cannot be
done, because there are so many possibilities.
Therefore, matters which are not especially described as possible in this manual should be
regarded as ”impossible”.
B-65312EN/04 SAFETY PRECAUTIONS
SAFETY PRECAUTIONS
This "Safety Precautions" section describes the precautions which must be observed to ensure safety
when using FANUC spindle motors.
Users of any spindle motor model are requested to read this manual carefully before using the spindle
motor.
The users are also requested to read this manual carefully and understand each function of the motor for
correct use.
The users are basically forbidden to do any behavior or action not mentioned in this manual. They are
invited to ask FANUC previously about what behavior or action is prohibited.
For matters that are not described in this manual, a machine must be designed and assembled in
accordance with EN60204-1 to ensure the safety of the machine and compliance with European
specifications. For details, refer to the specification.
Contents
WARNING
Applied when there is a danger of the user being injured or when there is a
damage of both the user being injured and the equipment being damaged if the
approved procedure is not observed.
CAUTION
Applied when there is a danger of the equipment being damaged, if the approved
procedure is not observed.
NOTE
The Note is used to indicate supplementary information other than Warning and
Caution.
s-1
SAFETY PRECAUTIONS B-65312EN/04
WARNING
WARNING
- Be safely dressed when handling a motor.
Wear safety shoes or gloves when handling a motor as you may get hurt on any edge or protrusion on it
or electric shocks.
- Before starting to connect a motor to electric wires, make sure they are
isolated from an electric power source.
A failure to observe this caution is very dangerous because you may get electric shocks.
- Do not supply the power to the motor while any terminal is exposed.
A failure to observe this caution is very dangerous because you may get electric shocks if your body or
any conductive stuff touches an exposed terminal.
s-2
B-65312EN/04 SAFETY PRECAUTIONS
WARNING
- Before touching a motor, shut off the power to it.
Even if a motor is not rotating, there may be a voltage across the terminals of the motor.
Especially before touching a power supply connection, take sufficient precautions.
Otherwise you may get electric shocks.
- Do not touch any terminal of a motor for a while (at least 5 minutes) after the
power to the motor is shut off.
High voltage remains across power line terminals of a motor for a while after the power to the motor is
shut off. So, do not touch any terminal or connect it to any other equipment. Otherwise, you may get
electric shocks or the motor and/or equipment may get damaged.
CAUTION
CAUTION
- Do not touch a motor when it is running or immediately after it stops.
A motor may get hot when it is running. Do not touch the motor before it gets cool enough. Otherwise,
you may get burned.
- FANUC motors are designed for use with machines. Do not use them for any
other purpose.
If a FANUC motor is used for an unintended purpose, it may cause an unexpected symptom or trouble. If
you want to use a motor for an unintended purpose, previously consult with FANUC.
s-3
SAFETY PRECAUTIONS B-65312EN/04
CAUTION
- Ensure that motors are cooled if they are those that require forcible cooling.
If a motor that requires forcible cooling is not cooled normally, it may cause a failure or trouble. For a
fan-cooled motor, ensure that it is not clogged or blocked with dust and dirt. For a liquid-cooled motor,
ensure that the amount of the liquid is appropriate and that the liquid piping is not clogged. For both types,
perform regular cleaning and inspection.
NOTE
NOTE
- Do not step or sit on a motor.
If you step or sit on a motor, it may get deformed or broken. Do not put a motor on another unless they
are in packages.
s-4
B-65312EN/04 SAFETY PRECAUTIONS
NOTE
- Do not modify a motor.
Do not modify a motor unless directed by FANUC. Modifying a motor may cause a failure or trouble in
it.
- For a motor with a terminal box, make a conduit hole for the terminal box in a
specified position.
When making a conduit hole, be careful not to break or damage unspecified portions. Refer to an
applicable specification manual.
- Before using a motor, measure its winding and insulation resistances, and
make sure they are normal.
Especially for a motor that has been stored for a prolonged period of time, conduct these checks. A motor
may deteriorate depending on the condition under which it is stored or the time during which it is stored.
For the winding resistances of motors, refer to the appendix of this specification manual, or ask FANUC.
For insulation resistances, see the following table.
s-5
SAFETY PRECAUTIONS B-65312EN/04
CAUTION LABEL
The following label is attached to the motor.
Attach this label to a prominent place on the motor to call attention to the user.
Remark:
The mark of this label conforms to the IEC standard, which is a global standard.
The mark has the meaning of heat caution, so the description is omitted.
s-6
B-65312EN/04 PREFACE
PREFACE
The models covered by this manual, and their abbreviations are:
Series Model
βiI series βiI 3/10000, βiI 6/10000, βiI 8/10000, βiI 12/8000, βiI 15/7000
βiIP 12/6000, βiIP 15/6000, βiIP 18/6000, βiIP 22/6000,
βiIP series
βiIP 30/6000, βiIP 40/6000
βiIC series βiIC 3/6000, βiIC 6/6000, βiIC 8/6000
The spindle motor can be used for the spindle of a machine tool. The main part of this manual describes
how to use the spindle motor and contains general notes. Understand this manual thoroughly before using
the spindle motor correctly.
This manual describes the arrangement of power terminals and the outputs of detector signals, but does
not describe the connections to the servo amplifier and the CNC unit. For an explanation of the
connections, refer to the FANUC SERVO AMPLIFIER βi series DESCRIPTIONS (B-65322EN), the
FANUC SERVO AMPLIFIER αi-B series DESCRIPTIONS (B-65412EN), the FANUC SERVO
AMPLIFIER αi series DESCRIPTIONS (B-65282EN), the MAINTENANCE MANUAL (B-65285EN),
and the MAINTENANCE MANUAL (B-65325EN).
Related manuals
The following seven kinds of manuals are available for FANUC SPINDLE MOTOR βi series. In the table,
this manual is marked with an asterisk (*).
Document
Document name Major contents Major usage
number
• Specification
FANUC AC SERVO MOTOR αi series • Selection of motor
B-65272EN • Characteristics *
DESCRIPTIONS • Connection of motor
• External dimensions
p-1
B-65312EN/04 TABLE OF CONTENTS
TABLE OF CONTENTS
SAFETY PRECAUTIONS............................................................................s-1
DEFINITION OF WARNING, CAUTION, AND NOTE ............................................. s-1
WARNING ............................................................................................................... s-2
CAUTION ................................................................................................................ s-3
NOTE ...................................................................................................................... s-4
CAUTION LABEL .................................................................................................... s-6
PREFACE ....................................................................................................p-1
I. SPECIFICATION
1 LINEUP OF THE SERIES ....................................................................... 3
1.1 MOTOR LINEUP ........................................................................................... 3
1.2 FEATURES.................................................................................................... 3
2 ORDERING SPECIFICATION NUMBER ................................................ 4
3 MOTOR SPECIFICATIONS .................................................................... 6
3.1 TERMS .......................................................................................................... 6
3.2 CURVES AND DATA SHEET........................................................................ 7
3.2.1 About Characteristic Curves and Data Sheet ...........................................................7
3.2.2 βiI series .................................................................................................................13
Model βiI 3/10000.............................................................................................................. 13
Model βiI 6/10000.............................................................................................................. 14
Model βiI 8/10000.............................................................................................................. 15
Model βiI 12/8000.............................................................................................................. 16
Model βiI 15/7000.............................................................................................................. 17
3.2.3 βiIP series ...............................................................................................................18
Model βiIP 12/6000 ...................................................................................................... 18
Model βiIP 15/6000 ...................................................................................................... 19
Model βiIP 18/6000 ...................................................................................................... 20
Model βiIP 22/6000 ...................................................................................................... 21
Model βiIP 30/6000 ...................................................................................................... 22
Model βiIP 40/6000 ...................................................................................................... 23
3.2.4 βiIC series...............................................................................................................24
Model βiIC 3/6000 ........................................................................................................ 24
Model βiIC 6/6000 ........................................................................................................ 25
Model βiIC 8/6000 ........................................................................................................ 26
3.3 EXTERNAL DIMENSIONS .......................................................................... 27
3.3.1 Models βiI 3/10000, βiI 6/10000, βiIC 3/6000, βiIC 6/6000 ..................................28
3.3.1.1 External Dimensions.......................................................................................... 28
3.3.1.2 Shaft figure ........................................................................................................ 30
3.3.1.3 Allowable radial load......................................................................................... 31
3.3.1.4 Axial run-out accuracy ...................................................................................... 32
3.3.1.5 Power terminal arrangement.............................................................................. 33
3.3.2 Models βiI 8/10000, βiI 12/8000, βiIP 12/6000, βiIC 8/6000 ................................34
3.3.2.1 External Dimensions.......................................................................................... 34
3.3.2.2 Shaft figure ........................................................................................................ 36
3.3.2.3 Allowable radial load......................................................................................... 37
c-1
TABLE OF CONTENTS B-65312EN/04
4 BUILT-IN DETECTOR........................................................................... 53
4.1 TYPE AND SPECIFICATION METHOD ...................................................... 53
4.2 OUTLINE ..................................................................................................... 53
4.3 CONNECTION............................................................................................. 53
4.3.1 Details of Cable K14 ..............................................................................................54
4.3.1.1 For the spindle motor with αiM sensor ............................................................. 54
4.3.2 Details of Cable K17 ..............................................................................................56
4.3.2.1 For the spindle motor with αiMZ sensor ........................................................... 56
APPENDIX
A PARAMETER TABLE FOR EACH MOTOR MODEL ........................... 97
A.1 SPINDLE MOTOR βiI series ....................................................................... 98
A.2 SPINDLE MOTOR βiIP series ................................................................... 101
A.3 SPINDLE MOTOR βiIC series ................................................................... 103
c-3
I. SPECIFICATION
B-65312EN/04 SPECIFICATION 1.LINEUP OF THE SERIES
1.2 FEATURES
(1)βiI series, βiIP series
The FANUC AC SPINDLE MOTOR βiI series and βiIP series is a highly cost-effective series having
sufficient basic performance as the core machine tool.
Features
• High-output and high-torque are implemented defying its compact body.
• Spindle HRV control enables high-efficiency and low-heating driving.
• The built-in αiM sensor or αiMZ sensor enables synchronous spindle and Z-axis feed, rigid tapping,
and Cs contouring.
• Improvement in machining of the motor housing enhances the accuracy of the mounting part.
• Waterproof and pressure-proof design conforming to the international standard (IEC) is employed to
improve reliability and make it resistant to most environments.
(2)βiIC series
The FANUC AC spindle motor βiIC series improve spindle axis sensor-less control utilizing spindle speed
information detected by αiBZ Sensor or αi Positioncoder.
Features
• This spindle motor realizes economically better systems when combined with βiSVSPc amplifier.
• Improvement of output characteristics at high speed and speed stability at low speed by spindle
sensor-less control
• Waterproof and pressure-proof design conforming to the international standard (IEC) is employed to
improve reliability and make it resistant to most environments.
-3-
2. ORDERING
SPECIFICATION NUMBER SPECIFICATION B-65312EN/04
A06B--BU{V#abcd
An ordering specification number are described on the tables after next page.
* Every combination doesn’t exist.
U 1 : Flange mounting
2 : Foot mounting
abcd An ordering specification number are described on the tables after next page.
* Not all models have this number.
The following lists the combinations of selectable numbers in symbols in specification Nos.
-4-
2.ORDERING
B-65312EN/04 SPECIFICATION SPECIFICATION NUMBER
Symbol in specification △ ○ ▽
No. □□□□
1 2 0 5 0 1 3 4 6 7
Model name
βiIP 12/6000 1458 ○ ○ ○ ○ ○ ○ ○ ○ - -
βiIP 15/6000 1442 ○ ○ ○ ○ ○ ○ ○ ○ - -
βiIP 18/6000 1443 ○ ○ ○ ○ ○ ○ ○ ○ - -
βiIP 22/6000 1459 ○ ○ ○ ○ ○ ○ ○ ○ - -
βiIP 30/6000 1499 ○ ○ ○ ○ ○ ○ ○ ○ - -
βiIP 40/6000 1480 ○ ○ ○ ○ ○ ○ ○ ○ - -
∗ For the βiIP series, #abcd is omitted.
-5-
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
3 MOTOR SPECIFICATIONS
3.1 TERMS
To ensure consistency with our other models (servo motor αiS series, built-in spindle motor BiI series,
etc.), this manual uses some terms and symbols that are different from those used before.
The following table shows the correspondence between the key terms and symbols of the previous
version (Edition 03) of the Descriptions (B-65312EN) and those of this version.
Correspondence table
This version Previous version
Unit
(Edition 04) (Edition 03) Description
(SI)
Term Symbol Term Symbol
S2 {-minute rated {-minute rated Output capable of operating the motor for {
- - kW
output(*1) output(*1) minutes
S1 continuous rated Continuous rated Maximum value of the current necessary for
IC - A(rms)
current current outputting the S1 rated output Pc
S2 {-minute rated {-minute rated Maximum value of the current necessary for
- - A(rms)
current(*1) current(*1) outputting the S2 {-minute rated output
Load moment of
- Load inertia - kg▪m2 Moment of inertia coupled to the rotor
inertia
-6-
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
Speed-output characteristics
Speed-output characteristics show the relations between motor output and speed.
In the S1 continuous operating zone, the motor can be used continuously with any combination of speed
and output.
The S2 {-minute operating zone is a zone in which the motor can be used at room temperature for the
indicated time.
The S3 {% operating zone is a zone in which the motor can output the indicated percentage in a single
cycle (10 minutes) in intermittent use.
A data sheet shows values when the input voltage is 200 V.
Output
[kW]
16
Maximum output at acceleration
for acceleration time calculation
12.1kW
12 S2 15-minute, S3 25%
S2 60-minute, 11kW
operating zone
S3 40%
operating zone
8 7.5kW
4 2.42kW
S1 continuous
operating zone
2.2kW
1.5kW
1500 4500
0
0 2000 4000 6000 8000 10000
-1
Base speed (S2,S3) Motor speed [min ] Maximum speed
Base speed (S1)
Speed-output characteristics chart
Example) βiI 8/10000
-7-
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
Speed-torque characteristics
Speed-torque characteristics show the relations between motor torque and speed.
The definitions of S1, S2, and S3 are the same as those for speed-output characteristics.
A data sheet shows values when the input voltage is 200 V.
Torque
Constant torque range
[N⋅m]
80
S2 15-minute, S3 25%
operating zone
60
S2 60-minute, S3 40%
Constant torque range
operating zone
40
Continuous rated S1 continuous operating zone
torque in the
constant torque
range
20
1500
0
0 2000 4000 6000 8000 10000
-1
Motor speed [min ]
T[N⋅m]=P[kW]¯1000/0.1047/N[min-1]
P[kW] :Motor output
N[min-1]:Motor speed
-8-
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
Time
Motor temperature
Achieving temperature
Time
The rated output is guaranteed at the rated power voltage (amplifier input: 200/220/240 VAC, 50/60Hz).
If the input power voltage fluctuates, the rated output may not be achieved even within the permissible
range.
Time
Operation
time
Motor temperature
Achieving temperature
Time
The rated output is guaranteed at the rated power voltage (amplifier input: 200/220/240 VAC, 50/60Hz).
If the input power voltage fluctuates, the rated output may not be achieved even within the permissible
range.
-9-
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
Motor output
Time
Operation Stopping
time time
Motor temperature
Achieving temperature
Time
Operation time
Cycle retention percentage= ¯100[%]
One cycle time
The rated output is guaranteed at the rated power voltage (amplifier input: 200/220/240 VAC, 50/60Hz).
If the input power voltage fluctuates, the rated output may not be achieved even within the permissible
range.
- 10 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
Weight: w [kg]
Weight of the motor.
Vibration
Vibration class (rotation direction) of the motor (model without a key way). The vibration class is
determined by measuring the full amplitude (P-P) of the motor when the motor is driven with no load and
at the maximum speed. If, for example, the vibration class is V5, the full amplitude of the motor with no
load and at the maximum speed is 5μm (P-P) or less.
Amplitude
Time
Noise
Noise level of the motor. It is measured at a position 1 m apart from the motor, by using a frequency filter
with the A characteristic.
1m
Cooling system
Cooling system of the motor. The definition is as per IEC60034-6, and the IC code is as per IEC 34-6.
- 11 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
- 12 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
- 13 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
- 14 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
- 15 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
- 16 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
- 17 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
- 18 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
750 750
0 0
0 1200 1500 3000 4500 6000 0 1200 1500 3000 4500 6000
-1 -1
Motor speed [min ] Motor speed [min ]
- 19 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
- 20 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
7.5kW S1 continuous
S1 continuous
5 5.5kW 60 operating zone
operating zone
750 750
0 0
0 1000 1500 3000 4500 6000 0 1000 1500 3000 4500 6000
-1 -1
Motor speed [min ] Motor speed [min ]
- 21 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
0 750 750
0
0 1000 1500 3000 4500 6000 0 1000 1500 3000 4500 6000
-1 -1
Motor speed [min ] Motor speed [min ]
- 22 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
12 12.1kW 150
11kW
S1 continuous
S1 continuous 100
7kW operating zone
6 operating zone
50
0 650 650
0
0 1500 3000 4500 6000 0 1500 3000 4500 6000
-1 -1
Motor speed [min ] Motor speed [min ]
- 23 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
Output Torque
[kW] [N⋅m]
S2 60-minute S2 15-minute
8 40
operating zone operating zone
S2 15-minute
Maximum operating zone
6.1kW
6 output at 30
5.5kW acceleration S2 60-minute
operating zone
4.1kW
4 3.7kW 20 S1 continuous
3.7kW operating zone
3kW
S1 continuous
2 operating zone 10
- 24 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
Output Torque
[kW] S2 15-minute
operating zone [N⋅ m]
10 S2 60-minute
60
operating zone Maximum
S2 15-minute
8.3kW output at operating zone
8 7.5kW acceleration
45
S2 60-minute
6 5.5kW 6.1kW operating zone
5.5kW
30 S1 continuous
4.4kW operating zone
4
S1 continuous
operating zone 15
2
2000 2000
0 0
0 1500 3000 4500 6000 0 1500 3000 4500 6000
-1 -1
Motor speed [min ] Motor speed [min ]
- 25 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
Output Torque
[kW] [N⋅m]
15 S2 60-minute, S2 15-minute
80
operating zone operating zone S2 15-minute
12.1kW Maximum operating zone
12 11kW output at
60 S2 60-minute
acceleration
operating zone
9
7.5kW 8.3kW S1 continuous
7.5kW 40
operating zone
6 6kW
S1 continuous
operating zone 20
3
3.3.1 Models βiI 3/10000, βiI 6/10000, βiIC 3/6000, βiIC 6/6000 ..................................................28
3.3.2 Models βiI 8/10000, βiI 12/8000, βiIP 12/6000, βiIC 8/6000 ................................................34
3.3.3 Models βiI 15/7000, βiIP 15/6000, βiIP 18/6000, βiIP 22/6000, βiIP 30/6000 .......................40
3.3.4 Models βiIP 40/6000 ....................................................................................................................... 46
- 27 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
3.3.1 Models βiI 3/10000, βiI 6/10000, βiIC 3/6000, βiIC 6/6000
- 28 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
- 29 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
(2)Shaft details
(a)φ28 Shaft with no key (βiI 3/10000, βiIC 3/6000)
- 30 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
NOTE
1 When using a belt, adjust the tension so the allowable loads indicated above are
not exceeded. If an excessive load is applied, consider the use of a support
bearing on the machine side to maintain the long-term reliability of the motor. (If
an excessive
2 When the belt tension is maximized at a point outside the output shaft end, the
allowable loads are less than those at the output shaft end.
3 If a thrust load is applied when a helical gear is used, the shaft moves in the
direction of the thrust. So, as a general rule, never apply a thrust load.
- 31 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
10
- 32 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
Output axis
direction
- 33 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
3.3.2 Models βiI 8/10000, βiI 12/8000, βiIP 12/6000, βiIC 8/6000
- 34 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
- 35 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
(2)Shaft details
(a) φ32 Shaft with no key
- 36 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
NOTE
1 When using a belt, adjust the tension so the allowable loads indicated above are
not exceeded. If an excessive load is applied, consider the use of a support
bearing on the machine side to maintain the long-term reliability of the motor. (If
an excessive
2 When the belt tension is maximized at a point outside the output shaft end, the
allowable loads are less than those at the output shaft end.
3 If a thrust load is applied when a helical gear is used, the shaft moves in the
direction of the thrust. So, as a general rule, never apply a thrust load.
- 37 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
10
- 38 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
Output axis
direction
- 39 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
3.3.3 Models βiI 15/7000, βiIP 15/6000, βiIP 18/6000, βiIP 22/6000,
βiIP 30/6000
- 40 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
- 41 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
(2)Shaft details
(a) φ48 Shaft with no key
- 42 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
NOTE
1 When using a belt, adjust the tension so the allowable loads indicated above are
not exceeded. If an excessive load is applied, consider the use of a support
bearing on the machine side to maintain the long-term reliability of the motor. (If
an excessive
2 When the belt tension is maximized at a point outside the output shaft end, the
allowable loads are less than those at the output shaft end.
3 If a thrust load is applied when a helical gear is used, the shaft moves in the
direction of the thrust. So, as a general rule, never apply a thrust load.
- 43 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
10
- 44 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
Output axis
direction
- 45 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
- 46 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
- 47 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
(2)Shaft details
(a) φ60 Shaft with no key
- 48 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATIONS
NOTE
1 When using a belt, adjust the tension so the allowable loads indicated above are
not exceeded. If an excessive load is applied, consider the use of a support
bearing on the machine side to maintain the long-term reliability of the motor. (If
an excessive
2 When the belt tension is maximized at a point outside the output shaft end, the
allowable loads are less than those at the output shaft end.
3 If a thrust load is applied when a helical gear is used, the shaft moves in the
direction of the thrust. So, as a general rule, never apply a thrust load.
10
- 49 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
Output axis
direction
- 50 -
B-65312EN/04 SPECIFICATION 3.MOTOR SPECIFICATION
βiIP 40/6000 170-253 200 0.38 1.59 170-253 200 0.46 1.57
NOTE
1 The term "surge current" represents a peak-to-peak current that flows when the
power is turned on.
2 The values listed below are a rough standard. They are not guaranteed.
For a non-screw terminal block (Peel off each wire sheath on the motor side by 8 to 9 mm.)
φ11
- 51 -
3.MOTOR SPECIFICATIONS SPECIFICATION B-65312EN/04
Screwdriver
Use a flat-blade screwdriver with a blade size of 3.5 ×
Sheath Conductor 0.5 mm.
(210-120J (standard type), 210-350J (short type)
manufactured by WAGO)
Connection procedure
<1> Insert the tip of the screwdriver into the screwdriver
insertion slot (small rectangular hole) until the tip
touches the spring. Next, while tilting the screwdriver
toward the inside of the terminal block, push the
screwdriver until it butts the conductive plate. In this
<3> state, the spring is opened completely, and the
Screwdriver screwdriver is held in the terminal block. Ensure that
<4>
the screwdriver is secured. Otherwise, the next step
<1> (wire insertion) cannot be conducted easily.
<2> <2> Check the peel-off length (8 to 9 mm), then insert the
wire into the wire insertion slot (large rectangular hole)
until it stops, by sliding the wire along the outer side of
the hole slowly so that the conductor does not become
loose. Be careful not to push a thin wire excessively.
<3> While holding down the inserted wire by one hand,
extract the screwdriver. The spring is closed to make a
connection.
<4> By slightly pulling the wire, check that the wire is
connected firmly. The wire need not be pulled
intensely.
Conductor Spring Cautions
Conductive plate - Only one wire must be connected to one spring.
- A wire, which may be a stranded wire or single
conductor, can be directly connected without
performing terminal processing if its sheath is peeled
off. A wire after ferrule processing can also be
connected.
Screwdriver
Non-screw
terminal block Conductor
- 52 -
B-65312EN/04 SPECIFICATION 4.BUILT-IN DETECTOR
4 BUILT-IN DETECTOR
The αiM/MZ sensor is a detector built into the standard spindle motor.
(Reference)
The αiM/MZ sensor is available in the types below.
αiM/MZ sensor types
Sensor name One-rotation signal detection Number of teeth
αiM sensor No
128λ, 256λ
αiMZ sensor Yes
4.2 OUTLINE
(Omitted because the sensor is built into the motor.)
4.3 CONNECTION
For the αiM sensor → Cable K14
For the αiMZ sensor → Cable K17
- 53 -
4.BUILT-IN DETECTOR SPECIFICATION B-65312EN/04
(7) MB VB (A3)
(8) *MB RB (B3)
(10) SS SS (A5)
Cable specification : 6 common shielded cable (Three 0.18mm2 twisted pairs + 0.5mm2 wires)
Recommended cable conductor : A66L-0001-0368
NOTE
1 If only one 5 V line and only one 0 V line are used, use pins 20 and 16 for them,
so that, if the connector is attached the wrong way, the sensor can be prevented
from being damaged.
2 For the recommended cable conductor, the maximum length is 72 m.
3 If using a cable conductor other than the recommended one, make sure that the
sum of the 5V-0V electric wire resistances is 5 Ω or less.
4 For an explanation of the recommended cable and the JYA2-side connector
conforming to the recommended cable, refer to the FANUC SERVO AMPLIFIER
βi series DESCRIPTIONS (B-65322EN).
WARNING
If the feedback signal is connected incorrectly, an unpredictable motor operation
may occur.
- 54 -
B-65312EN/04 SPECIFICATION 4.BUILT-IN DETECTOR
10 SS 20 5V
9 5V 19 #
8 *MB 18 5V
7 MB 17 #
6 *MA 16 0V
5 MA 15 THR2
4 OH2 14 0V
3 OH1 13 THR1
2 *MZ 12 0V
1 MZ 11 #
NOTE
Do not use any pin that is marked #, because they may already be in use for
input/output signals for an optional PCB.
Pin arrangement of the connector (manufactured by Tyco Electronics Japan GK) on the motor side
A1 +5V B1
A2 VA B2 RA
A3 VB B3 RB
A4 B4
A5 SS B5 0V
A6 THR1 B6 THR2
- 55 -
4.BUILT-IN DETECTOR SPECIFICATION B-65312EN/04
(5) MA VA (A2)
(6) *MA RA (B2)
(7) MB VB (A3)
(8) *MB RB (B3)
(10) SS SS (A5)
Cable specification : 6 common shielded cable (Four 0.18mm2 twisted pairs + 0.5mm2 wires)
Recommended cable conductor : A66L-0001-0368
NOTE
1 If only one 5 V line and only one 0 V line are used, use pins 20 and 16 for them,
so that, if the connector is attached the wrong way, the sensor can be prevented
from being damaged.
2 For the recommended cable conductor, the maximum length is 50 m.
3 If using a cable conductor other than the recommended one, make sure that the
sum of the 5V-0V electric wire resistances is 4Ω or less.
4 For an explanation of the recommended cable and the JYA2-side connector
conforming to the recommended cable, refer to the FANUC SERVO AMPLIFIER
βi series DESCRIPTIONS (B-65322EN).
- 56 -
B-65312EN/04 SPECIFICATION 4.BUILT-IN DETECTOR
WARNING
If the feedback signal is connected incorrectly, an unpredictable motor operation
may occur.
JYA4
10 SS 20 5V
9 5V 19 #
8 *MB 18 5V
7 MB 17 #
6 *MA 16 0V
5 MA 15
4 # 14 0V
3 # 13
2 *MZ 12 0V
1 MZ 11 #
NOTE
Do not use any pin that is marked #, because they may already be in use for
input/output signals for an optional PCB.
Pin arrangement of the connector (manufactured by Tyco Electronics Japan GK) on the motor side
A1 +5V B1
A2 VA B2 RA
A3 VB B3 RB
A4 VZ B4 RZ
A5 SS B5 0V
A6 THR1 B6 THR2
- 57 -
II. CONFIGURATION AND SELECTION
CONFIGURATION 1.CONNECTING A SPINDLE
B-65312EN/04 AND SELECTION MOTOR
Connection diagram
Amp lifier
Spindle motor
Signal line (αiM/MZ, th ermistor)
Note
Frame
gro und
Ground
line
* For the βiIC series, only the thermistor signal line is to be connected.
CAUTION
If a motor is not connected to ground through the machine (cabinet) in which the
motor is installed, connect the motor grounding point and the amplifier grounding
point to absorb noise. In this case, use a wire with a thickness of at least 1.25
mm2, other than the GND conductor in the power line. Keep the wire as far from
the power line as possible.
For an explanation of the arrangement of the power terminals on the spindle motor side, see Section 3.3,
"EXTERNAL DIMENSIONS", in Part I.
- 61 -
1. CONNECTING A SPINDLE CONFIGURATION
MOTOR AND SELECTION B-65312EN/04
- 62 -
2.CONDITIONS FOR
CONFIGURATION APPROVAL RELATED TO
B-65312EN/04 AND SELECTION THE IEC60034 STANDARD
This chapter, "CONDITIONS FOR APPROVAL RELATED TO THE IEC60034 STANDARD", consists
of the following sections:
βiI series
Model name Motor specification number
βiI 3/10000 A06B-1444-Bxxx
βiI 6/10000 A06B-1445-Bxxx
βiI 8/10000 A06B-1446-Bxxx#010x
βiI 12/8000 A06B-1447-Bxxx#010x
βiI 15/7000 A06B-1498-Bxxx
βiIP series
Model name Motor specification number
βiIP 12/6000 A06B-1458-Bxxx
βiIP 15/6000 A06B-1442-Bxxx
βiIP 18/6000 A06B-1443-Bxxx
βiIP 22/6000 A06B-1459-Bxxx
βiIP 30/6000 A06B-1499-Bxxx
βiIC series
Model name Motor specification number
βiIC 3/6000 A06B-1415-Bxxx#0009
βiIC 6/6000 A06B-1416-Bxxx#0009
βiIC 8/6000 A06B-1417-Bxxx#0009
- 63 -
2. CONDITIONS FOR
APPROVAL RELATED TO CONFIGURATION
THE IEC60034 STANDARD AND SELECTION B-65312EN/04
IP4 : Machine protected from introduction of solid foreign matter over 1.0 mm
- Electric cables and wires with a diameter or thickness greater than 1.0 mm do not enter.
Note that these models satisfy the provisions for short-time water immersion, and do not guarantee their
water-proof performance in an atmosphere in which cutting fluid is applied directly to the motor.
Use a motor with the output axis being between 45° upward and vertical downward.
- 64 -
2.CONDITIONS FOR
CONFIGURATION APPROVAL RELATED TO
B-65312EN/04 AND SELECTION THE IEC60034 STANDARD
(6) Heat protection (IEC60034-11)
The spindle motor conforms to the heat protection standard (IEC60034-11) by using an overheat
protection circuit with temperature detection (overheat alarm).
(8) Remarks
For details on EMC compliance authorization, refer to the separate manual "Compliance with EMC
Directives"
Mechanical and electrical safety of each motor should be evaluated after the motor is mounted on the
machine.
- 65 -
CONFIGURATION
3.MOTOR TYPES AND SELECTION B-65312EN/04
3 MOTOR TYPES
3.1 SELECTING MOTOR SPECIFICATIONS ACCORDING TO
THE SPINDLE STRUCTURE
Each model includes the types of motors listed below, and the user can make an optimal choice according
to the spindle driving structure.
See the chapter 1, “ORDERING SPECIFICATION NUMBER” in the Part I or Order List (B-65311EN)
for available motors.
- 66 -
CONFIGURATION
B-65312EN/04 AND SELECTION 3.MOTOR TYPES
- 67 -
CONFIGURATION
3.MOTOR TYPES AND SELECTION B-65312EN/04
Max. output
at ac celeration
Po
Outpu t (kW)
Pm
Max.
rated output
① ② ③
Nb Nf Nm
-1
Motor speed (min )
t 1 = 0.01097 ⋅
(J L + J m ) ⋅ N b 2 [sec]
Po ⋅ 1000
t 2 = 0.01097 ⋅
(J L + J m ) ⋅ (N f 2 − N b 2 ) [sec]
2 ⋅ Po ⋅ 1000
⎧ Pm ⎫
(J L + J m ) ⋅ (N m − N f ) ⋅ ⎨(N m − N f ) − Po ⋅ N m − Pm ⋅ N f ⋅ ln ⎬
⎩ Pm − Po Po ⎭ [sec]
t 3 = 0.01097 ⋅
(Pm − Po ) ⋅ 1000
The total time (t) required for acceleration in the range from 0 to Nm is t1+t2+t3 [sec]
NOTE
This is not a guaranteed value but a guideline.
- 68 -
CONFIGURATION
B-65312EN/04 AND SELECTION 3.MOTOR TYPES
Reference 1
The moment of inertia of a cylindrical object rotating about its central axis is calculated as follows:
-SI unit---------------------------
πγ b
Jb = [kg⋅m2]
4
Db Lb
32
Jb : Moment of inertia [kg⋅m2]
γb : Weight of the object per unit volume [kg/m3]
Db : Diameter of the object [m]
Lb : Length of the object [m]
Reference 2
The moment of inertia applied to the motor shaft for JO is calculated as follows:
2 2
⎛ Z1 ⎞ ⎛1⎞
J = ⎜⎜ ⎟⎟ × J0 or ⎜ ⎟ × J0
⎝ Z2 ⎠ ⎝Z⎠
Jo : Moment of inertia before deceleration
Z1 : Number of teeth of the gear on the motor side (for gear connection)
Z2 : Number of teeth of the gear on the spindle side (for gear connection)
1/Z : Deceleration ratio
- 69 -
CONFIGURATION
3.MOTOR TYPES AND SELECTION B-65312EN/04
Motor
speed
t1 t2 t3 t4 t5
Motor
output P1 P2 P3 P4 P1
P12 t 1 + P2 2 t 2 + P3 2 t 3 + P 4 2 t 4
RMS output Pav = [kW]
Dt
NOTE
1 Cutting output P3 at motor speed N which is lower than base speed Nb shall be
calculated by the following equation.
P3=PC × Nb/N [kW] (PC: Actual cutting output)
2 In case that P3 is calculated by the load indicator voltage, use the following
equation.
P3=P1 × L3/10 [kW] (L3: Load indicator voltage in cutting [V])
- 70 -
III. HANDLING, INSTALLATION, AND USE
ENVIRONMENT OF THE MOTOR
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
B-65312EN/04 OF THE MOTOR 1.MOTOR HANDLING
1 MOTOR HANDLING
This chapter contains notes on handling the FANUC AC spindle motor βi series.
1.1 CHECKING A DELIVERED SPINDLE MOTOR AND STORING A SPINDLE MOTOR ..........73
1.2 SEPARATING AND DISPOSING OF A SPINDLE MOTOR....................................................74
FANUC spindle motors are completely checked before shipment, and the inspection at acceptance is
normally unnecessary. When an inspection is required, check the specifications (wiring, current, voltage,
etc.) of the motor and sensor. Store the motor indoors. The storage temperature is -20°C to +60°C. Avoid
storing in the following places.
- 73 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
1.MOTOR HANDLING OF THE MOTOR B-65312EN/04
Terminal box
Fan cover
- 74 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
B-65312EN/04 OF THE MOTOR 2.MOTOR INSTALLATION
2 MOTOR INSTALLATION
This chapter describes how to install the FANUC AC spindle motor βi series.
NOTE
The SPANN ELEMENTE RfN8006 is manufactured by RINGFEDER.
The clamping sleeve DSM is manufactured by SPIETH.
SPANN ELEMENTE
- 75 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
2.MOTOR INSTALLATION OF THE MOTOR B-65312EN/04
2 After attaching a pulley to the motor, adjust the runout of the belt groove to within 20 μm (T.I.R).
3 Before the belt is looped, FANUC recommends that the dynamic balance (field balance) be
corrected.
4 Limit the radial load applied to the motor output shaft by the tension of the belt to the allowable
value described in the manual for each series. If the allowable value is exceeded, the bearing or shaft
may fail prematurely.
5 The tension of the belt is reduced as a result of abrasion during the initial several hours of operation.
To transfer torque normally after this reduction in tension, the initial tension before operation should
be set to a value 1.3 times the actually required tension T.
Recommended belts:
Ribace manufactured by BANDO.
Ribstar manufactured by MITSUBOSHI.
7 Reduce the deviation between the positions of the motor and machine pulleys in the shaft direction
as much as possible and ensure that the center lines of the shafts are as parallel as possible.
Spindle
Spindle motor
- 76 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
B-65312EN/04 OF THE MOTOR 2.MOTOR INSTALLATION
Motor model βiI 3/10000 βiI 6/10000 βiI 8/10000 βiI 12/8000
Designed power (15 min. rated output × 1.1) [kW] 6.1 8.3 12.1 16.5
Belt type 5M (5MS) 5M (5MS) 5M (5MS) 7M (7MS)
Pulley dia. on the spindle side (PCD) [mm] φ 165 φ 165 φ 210 φ 210
Pulley dia. on the motor side (PCD) [mm] φ 132 φ 132 φ 168 φ 168
Gear reduction ratio 0.80 0.80 0.80 0.80
Motor max. speed [min-1] 8,000 8,000 6,000 6,000
Belt surface speed (at the max. motor speed) [m/s] 55.3 55.3 52.8 52.8
Number of belt crests 4 6 7 4
Static axial load for new belts [N] 1,200 1,638 1,904 2,604
Static axial load for re-stretched belts [N] 923 1,260 1,464 2,003
Allowable radial load (at the output axis center) [N] 1445 1,607 2,205 3,371
NOTE
1 Prevent oil or dust from entering between the belt and the pulley. Otherwise, the
belt may slip.
2 If the allowable radial load is exceeded, reduce the load by using support
bearings on the machine side or directly connecting to the machine in order to
secure reliability for a extended period of time.
- 77 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
2.MOTOR INSTALLATION OF THE MOTOR B-65312EN/04
3 Mount the motor on the machine so that the vibration acceleration is 0.5 G (4.9m/s2) or less when it
is measured using the method described in CAUTION 5 of Section 3.1, “COMMON”.
- 78 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
B-65312EN/04 OF THE MOTOR 2.MOTOR INSTALLATION
Flexible coupling has three tolerances of degree of freedom: eccentricity, declination, and axial
displacement. This enables coupling with less vibration and less noise to achieve high-speed
rotation.
• Tolerances of eccentricity and declination: Slight eccentricity and declination that could not be
absorbed by centering are absorbed.
• Tolerance of axial displacement: Extension of the spindle and motor shaft due to temperature
increase is absorbed.
(Caution)
• These tolerances are criteria for preventing the coupling from being damaged, not criteria for
preventing load from being applied to the spindle and motor bearings. Therefore, to perform
rotation with low vibration and low noise before high-speed rotation is achieved, the spindle
and motor shaft must be centered.
• FANUC has confirmed that with a coupling (disk coupling) that permits only the degrees of
freedom of declination and axial displacement, rotation can take place properly if centering has
been performed with a concentricity of 5 μm.
2 It is important to perform centering and obtain parallelism to avoid having to recourse to the
flexibility of the coupling.
At high speeds, any eccentricity may cause the bearing to fail prematurely.
3 Check all machines before shipping to confirm that the vibration acceleration is 0.5 G (4.9m/s2) or
less when measured using the method described in CAUTION 5 of Section 3.1, “COMMON”.
4 Set the torsional rigidity of the coupling to an appropriate high value. If the torsional rigidity is low,
vibration may be produced during orientation.
5 When attaching the coupling to the motor shaft, never use a hammer or the like; otherwise, impact
load is applied to the bearing.
6. When the motor shaft and the spindle are to be connected via a coupling, the motor shaft may remain
pressed inside the motor when the motor shaft is inserted into the spindle. (Caution is required
particularly for Oldham's coupling because the engagement is tight.)
- 79 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
2.MOTOR INSTALLATION OF THE MOTOR B-65312EN/04
With the motor shaft remaining pressed inside the motor, the precompression load of the built-in
bearing of the motor may be lost or become excessive, possibly causing the bearing to be defective.
After connection via a coupling, check that the motor shaft does not remain pressed inside the motor.
NOTE
Examples of how to check that the motor shaft does not remain pressed inside
the motor
- After connection via a coupling, check that the axis direction dimension (total
length) of the coupling itself is correct.
* In some cases, if the motor shaft is not inserted correctly, the total length may
be longer than the normal dimension.
- Before inserting the coupling, measure the distance between the coupling and a
datum plane of the motor (such as the inside low end), and check that the
distance does not change after insertion.
Alternatively, prepare a datum plane on the machine side to facilitate
measurement inside the coupling box, check the positional relation between the
datum plane of the motor and the datum plane on the machine side first, and
then check the position of the coupling from the datum plane on the machine
side.
(Reference)
- 80 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
B-65312EN/04 OF THE MOTOR 3.NOTES ON INSTALLATION
3 NOTES ON INSTALLATION
This chapter contains notes on installing the FANUC AC spindle motor βi series.
3.1 COMMON
Be sure to observe the following, regardless of the connection method of the motor:
WARNING
When connecting a metallic conduit to a plastic terminal box, connect the conduit to ground on the power
magnetics cabinet side.
CAUTION
1 Mount the motor so that the output shaft points in a direction ranging within 45 degrees above the
horizontal to vertically downwards.
- 81 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
3.NOTES ON INSTALLATION OF THE MOTOR B-65312EN/04
2 When the motor needs to be pointed to more than 45 degrees above the horizontal, consult you
FANUC representative.
3 Use the eyebolt of the motor to lift only a single motor, (gear and pulley may be attached).
4 Place a cover over an air-cooled motor to prevent the motor from being exposed to coolant or
lubricant.
5 Limit the vibration acceleration at the rear bracket of the motor to 0.5 G (4.9 m/s2) to ensure the
long-term reliability of each part of the motor.
In particular, to limit the acceleration in the case of direct connection to 0.5 G (4.9 m/s2), carefully
perform centering with the mating spindle and make the motor shaft parallel with the spindle.
- 82 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
B-65312EN/04 OF THE MOTOR 3.NOTES ON INSTALLATION
1. Using a pickup
A. Pressing a pickup against B. Screwing a block into the eyebolt
the side of the rear bracket internal thread on the rear
bracket, then screwing a pickup
into the block.
Block
Pickup Pickup
Side of the rear bracket Eyebolt internal thread
Eyebolt
internal thread
6 Dynamic balance
During high-speed operation, a small imbalance may cause a large vibration, resulting in an unusual
sound, premature bearing damage, or some other abnormality.
Therefore, reduce the amount of the imbalance with the dynamic balance of the other rotation shafts,
as well as the gear and pulley mounted on the output shaft of the motor, as much as possible.
• Balance correction
With the βi series, a shaft with no key is used as standard to facilitate the balance correction of
a pulley, gear, and coupling attached to the shaft. Use a completely symmetric pulley, gear, or
coupling, and use a backlash-less tightening part such as a SPANN ELEMENTE to secure a
pulley, gear, or coupling to the shaft. When attaching a pulley to a shaft, for example, adjust the
periphery vibration to within 20 μm. This basically eliminates the need for balance correction.
To further reduce the vibration level, make a field balance correction, for example, by
tightening a screw into the tapped hole for balance correction provided on a component such as
a pulley.
7 Vibrations applied to the motor must be 5Gs (4.9 m/s2) or less in a state where the motor is attached
to the machine.
- 83 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
3.NOTES ON INSTALLATION OF THE MOTOR B-65312EN/04
8 The edge of the fauset joint to mount the flange mounting type motor should be chamfered about C1.
9 Please space 30 mm or more between the fan cover and the partition to keep the cooling ability well.
We recommend to take a structure such as you can clean air holes and the fan cover easily.
NOTE
1 Cable wiring
Follow the procedure below to install the cable.
(1) Use a hammer to strike the portion for the cable hole on the terminal box and open the hole.
This time, pay attention not to break the other place except hole.
(2) Thread the cable through a conduit. Connect the conduit with the connector.
(3) Tighten the connector at the cable hole of the terminal box using a nut. (*1, *2)
(4) Connect each terminal appropriately in the terminal box with screws.
- 84 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
B-65312EN/04 OF THE MOTOR 3.NOTES ON INSTALLATION
When a hole once made is not used, purchase the following rubber bushing and mount it at the hole.
NOTE 1
When the 90 degrees connector is used in the following models, the mounting direction of the
conduit is restricted to prevent interference between the conduit and the motor. To allow the
conduit to be mounted in any direction, use the 45 degrees connector.
(In a model other than the following, the conduit can be mounted in any direction even when
the 90 degrees connector is used.)
Applicable models: βiI 15/7000, βiIP 15/6000, βiIP 18/6000, βiIP 22/6000, βiIP 30/6000
For the 90° connector
NOTE 2
The nut used to fasten the connector to the terminal box must be smaller than the size listed
below. (Any larger nut interferes with the terminal box.) For the diameter of the cable hole in
each model, refer to the outside dimension drawing of the respective models.
- 85 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
3.NOTES ON INSTALLATION OF THE MOTOR B-65312EN/04
e t
2 Center of gravity
The distance L from the flange end face to the center of gravity in each model is listed below.
Center
of gravity
- 86 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
B-65312EN/04 OF THE MOTOR 3.NOTES ON INSTALLATION
Ambient humidity
The ambient humidity should be 80%RH or less and no condensation should not be caused.
Installation height
Up to 1,000 meters above the sea level requires, no particular provision for attitude. When operating the
machine at a higher level, special care is unnecessary if the ambient temperature is lowered 1°C at every
100m higher than 1,000m. For example, when the machine is installed at a place of 1,500 meters above
sea level, there is no problem if the ambient temperature is 35°C or less.
Vibration
When installed in a machine, the vibration applied to the motor must not exceed 5G (49m/s2).
If any one of the four environmental conditions (ambient temperature, ambient humidity, installation
height, and vibration) specified above is not satisfied, the output must be restricted.
- 87 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
3.NOTES ON INSTALLATION OF THE MOTOR B-65312EN/04
2. Motor periphery
If the cutting fluid or lubricant falls on the motor, it will adversely affect the sealing properties of the
motor surface, entering the inside of the motor and possibly damaging the motor.
• Make sure that the motor surface is never wet with the cutting fluid or lubricant, and also make sure
that no fluid builds up around the motor. If there is a possibility of the surface being wet, a cover is
required.
• If the cutting fluid is misted, the cutting fluid may be condensed on the inside of the cover and fall
on the motor. Make sure that no condensed droplets fall on the motor.
• If the inside of the machine is full of misted cutting fluid, the cutting fluid adhered to the motor can
enter the inside of the motor and damage the motor. Install a mist collector with an appropriate
capacity to prevent the inside of the machine from becoming full of mist.
• Completely separate the machining area from the motor area, using a telescopic cover, accordion
curtain, and so on. Note that partitions such as accordion curtains are consumable and require
periodic inspection for damage.
- 88 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
B-65312EN/04 OF THE MOTOR 3.NOTES ON INSTALLATION
For those models with an oil seal, ensure that the surface of the lubricant is below the lip of the oil seal.
If a simple labyrinth is used as the output shaft seal or if no seal is provided (foot mounting type), ensure
that lubricant does not splash onto the flange surface. If such a motor is directly mounted on a gear box,
the lubricant may gradually penetrate inside the motor even when no lubricant splashes on flange surface,
thus resulting in motor failure. Therefore, do not mount such a motor on a gear box directly.
When the motor is used in an environment in which lubricant does not splash onto the motor, the simple
labyrinth type instead of the oil seal type may be selected. Generally in a dry environment, the motor
temperature of the simple labyrinth type will increase more moderately than that of the oil seal type.
- 89 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
3.NOTES ON INSTALLATION OF THE MOTOR B-65312EN/04
• When the motor is rotating, the oil seal has an effect of discharging any oil that enters, but if it is
pressurized for a long time when the motor is stopped, it may allow oil to enter through the lip.
When lubrication with an oil bath is conducted for gear engagement, for example, the oil level must
be below the lip of the oil seal of the shaft, and the oil level must be adjusted so that the oil does
nothing but splash on the lip.
Oil level
• If foreign matter such as cutting chips is caught by the oil seal lip, it will be easily worn, losing its
sealing properties. When the motor is used within a splash guard, and so cutting chips may fall on
the motor, for example, take measures to prevent cutting chips from entering near the lip.
• In an environment in which dry and wet states alternate, if cutting fluid splashes onto the lip after it
has worn in a dry state, the cutting fluid may easily enter the inside of the motor. In this case,
provide a cover to prevent cutting fluid from splashing onto the oil seal of the motor.
• The oil seal shows its sealing effect when a part such as the gear coupling is lubricated by oil bath.
Cutting fluid does not provide lubrication for the oil seal lip, so the cutting fluid may easily
penetrate the seal. Therefore, provide a cover to prevent cutting fluid from splashing onto the oil
seal.
- 90 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
B-65312EN/04 OF THE MOTOR 3.NOTES ON INSTALLATION
NOTE
1 The foot mounting type motors are not equipped with an oil seal. When an oil
seal is necessary, add #0002 to a motor drawing number when ordering the
motor. For details, refer to the order list (B-65311EN).
Example)
Model βiI 12/8000 (foot mounting type, with no key, rear exhaust)
To add an oil seal to A06B-1447-B200, order A06B-1447-B200#0002 .
2 When lubricant does not splash onto the oil seal, remove the coil spring of the oil
seal to reduce friction between the lip and shaft.
This does not affect sealing from dry dust.
When the area in which the shaft touches the oil seal is dry, turning the shaft at a
high speed may generate contact sound (abnormal sound) from that area or may
damage the lip.
4. Motor coupling
When a coupling box is used to connect the motor to the machine, take measures as follows not to allow
leaked cutting fluid to build up in the coupling box.
• Provide a cover for the top and sides of the coupling box.
• Provide a drain hole at the bottom of the coupling box. The hole must be large enough to avoid
clogging.
Partition Cover
Spindle Motor
Drain Coupling box
- 91 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
3.NOTES ON INSTALLATION OF THE MOTOR B-65312EN/04
<Fault example>
The cutting fluid leaks from a gap in the accordion curtain to the motor area, and builds up in the
coupling box. While the spindle is moving, the cutting fluid ripples, splashing onto the oil seal of the
motor. The cutting fluid enters the inside of the motor there in large quantities, deteriorating the
insulation of the motor.
Accordion curtain
There is a gap, so the cutting fluid enters No cover, thus the cutting fluid falls in
the motor area. the box.
Machining
Motor area
area
Spindle Motor
Drain Coupling box
The hole is too small, and clogged.
• When a conduit is attached to the terminal box, use a water-proof connector with rubber packings to
prevent lubricant and cutting fluid from entering the inside of the terminal box through its cable
holes.
• On the inner side of the upper lid of the terminal box, a rubber water-proof packing is installed.
Ensure that the packings are not damaged, then install the lid so that no foreign matter is caught.
Connector Terminal
box
Nut
Rubber packing
• If the connector you want to use is smaller than the cable hole on the terminal box, prepare the
bushing, nut, and O-ring shown below.
O-ring
Connector
Bushing
Nut
- 92 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
B-65312EN/04 OF THE MOTOR 3.NOTES ON INSTALLATION
NOTE
For the diameter of the cable hole in each model, refer to the outside dimension
drawing of the respective models.
Cooling air
Filter
Cooling air
- 93 -
HANDLING, INSTALLATION,
AND USE ENVIRONMENT
4.NOTES ON OPERATION OF THE MOTOR B-65312EN/04
4 NOTES ON OPERATION
WARNING
1 When supplying voltage to the spindle motor or the fan motor, ensure that the earth cable is
connected to the earth terminal and secure that the spindle motor is put to earth certainly. In addition,
be sure to check that the power cable are secured to the terminal block.
CAUTION
1 Sound and vibration
Check that there is no abnormal sound or vibration.
2 Cooling
Clean off dust from the cooling air inlet and outlet of the stator every year, and check the flow of air
carefully. The table given below indicates the direction of the rotation of the cooling fan when
viewed from the rear side of the motor. Check that the actual rotating direction is correct.
NOTE
1 To increase the operating lifetime of a motor of these series, break in the motor. As a guideline,
increase the speed of the motor from 1000 min-1 to its maximum speed in 1000 min-1 increments,
and operate the motor at each speed for about 5 minutes.
- 94 -
APPENDIX
A.PARAMETER TABLE
B-65312EN/04 APPENDIX FOR EACH MOTOR MODEL
For an explanation of any matters that are not contained in this document, refer to the descriptions below.
FANUC AC SPINDLE MOTOR αi series,
FANUC AC SPINDLE MOTOR βi series,
FANUC BUILT-IN SPINDLE MOTOR Bi series
PARAMETER MANUAL (B-65280EN)
NOTE
1 The parameter tables contain two CNC models, FS30i and FS0i-D, as
representatives.
For an explanation of the parameter numbers for those models that are not
contained here, refer to the Parameter Manual (B-65280EN).
2 For those models for which no parameter tables are provided, such as models
under development, contact a FANUC service representative.
- 97 -
A.PARAMETER TABLE
FOR EACH MOTOR MODEL APPENDIX B-65312EN/04
- 98 -
A.PARAMETER TABLE
B-65312EN/04 APPENDIX FOR EACH MOTOR MODEL
Motor model βi I 8/8000 βi I 8/8000 βi I 8/8000 βi I 8/10000 βi I 8/10000 β i I 8/10000 βi I 12/7000 βi I 12/7000
Specification 1446 1446 1446 1446 1446 1446 1447 1447
Applicable amplifier β i SVSP*-11 β i SVSP*-15 βi SVSPx-18 βi SVSP*-11 βi SVSP*-15 βi SVSP*-18 β i SVSP*-15 βi SVSP*-18
Model code 334 340 - 341 342 360 335 -
Applicable software series and edition 9D50/I 9D50/Q - 9D50/Q 9D50/Q 9D8A/A 9D50/I -
7.5kW 7.5kW 7.5kW 7.5kW 7.5kW 7.5kW 11kW 11kW
Continuous rated output -1 -1 -1 -1 -1 -1 -1 -1
2000/8000min 2000/8000min 2000/8000min 2000/10000min 2000/10000min 2000/10000min 2000/7000min 2000/7000min
11kW 11kW 11kW 11kW 11kW 11kW 15kW 15kW
S2 15 min rated output -1 -1 -1 -1 -1 -1 -1 -1
1500/8000min 1500/8000min 1500/8000min 1500/10000min 1500/10000min 1500/10000min 1500/7000min 1500/7000min
FS30i /FS0i
4007 00000000 ← ← ← ← ← 00000000 ←
4008 00000000 ← ← ← ← ← 00000000 ←
4009 00000000 ← ← ← ← ← 00000000 ←
4010 00010000 ← ← ← ← ← 00010000 ←
4011 00011010 ← ← ← ← ← 00011010 ←
4012 10000000 ← ← ← ← ← 10000000 ←
4013 00001100 ← ← ← ← ← 00001100 ←
4019 00000100 ← ← ← ← ← 00000100 ←
4020 8000 ← ← 10000 ← ← 7000 ←
4023
4039 0 ← ← ← ← ← 0 ←
4040
4041
4048
4049
4080 75 ← ← ← ← ← 60 ←
4083 30 ← ← ← ← ← 30 ←
4093 0 ← ← ← ← ← 0 ←
4100 1500 ← ← ← ← ← 1550 ←
4101 95 ← ← ← ← ← 82 ←
4102 2602 ← ← ← ← ← 1844 ←
4103 64 ← ← ← ← ← 80 ←
4104 2000 ← ← ← ← ← 3000 ←
4105 0 ← ← ← ← ← 0 ←
4106 6000 ← ← ← ← ← 8000 ←
4107 0 ← ← ← ← ← 0 ←
4108 0 ← ← ← ← ← 0 ←
4109 25 ← ← ← ← ← 25 ←
4110 887 1331 1774 887 1331 1774 1031 1375
4111 381 ← ← ← ← ← 355 ←
4112 200 ← ← ← ← ← 200 ←
4113 500 ← ← ← ← ← 705 ←
4114 0 ← ← ← ← ← 23040 ←
4115 100 ← ← ← ← ← 100 ←
4116 8000 ← ← ← ← ← 6300 ←
4117 90 ← ← ← ← ← 90 ←
4118 100 ← ← ← ← ← 100 ←
4119 19 ← ← ← ← ← 14 ←
4120 0 ← ← ← ← ← 0 ←
4124 0 ← ← ← ← ← 0 ←
4127 161 ← ← ← ← ← 150 ←
4128 78 ← ← ← ← ← 95 ←
4129 0 ← ← ← ← ← 0 ←
4130 25700 ← ← ← ← ← 25700 ←
4134 110 ← ← ← ← ← 110 ←
4136 0 ← ← ← ← ← 0 ←
4138 0 ← ← ← ← ← 0 ←
4139 0 ← ← ← ← ← 0 ←
4140 0 ← ← ← ← ← 0 ←
4141 0 ← ← ← ← ← 0 ←
4142 0 ← ← ← ← ← 0 ←
4143 0 ← ← ← ← ← 0 ←
4144 0 ← ← ← ← ← 0 ←
4145 0 ← ← ← ← ← 0 ←
4146 0 ← ← ← ← ← 0 ←
4147 0 ← ← ← ← ← 0 ←
4148 0 ← ← ← ← ← 0 ←
4149 0 ← ← ← ← ← 0 ←
4150 0 ← ← ← ← ← 0 ←
4151 0 ← ← ← ← ← 0 ←
4152 0 ← ← ← ← ← 0 ←
4153 0 ← ← ← ← ← 0 ←
4154 0 ← ← ← ← ← 0 ←
4155 0 ← ← ← ← ← 0 ←
4156 0 ← ← ← ← ← 0 ←
4158 0 ← ← ← ← ← 0 ←
4159 0 ← ← ← ← ← 0 ←
4161 0 ← ← ← ← ← 0 ←
4165 0 ← ← ← ← ← 0 ←
4166 0 ← ← ← ← ← 0 ←
4169 0 ← ← ← ← ← 0 ←
Maximum output
12.1kW 12.1kW 12.1kW 12.1kW 12.1kW 12.1kW 16.5kW 16.5kW
during acceleration
- 99 -
A.PARAMETER TABLE
FOR EACH MOTOR MODEL APPENDIX B-65312EN/04
- 100 -
A.PARAMETER TABLE
B-65312EN/04 APPENDIX FOR EACH MOTOR MODEL
- 101 -
A.PARAMETER TABLE
FOR EACH MOTOR MODEL APPENDIX B-65312EN/04
Motor model βi IP 15/6000 βi IP 15/6000 βi IP 15/6000 βi IP 18/6000 βi IP 18/6000 βi IP 18/6000 βi IP 22/6000 βi IP 22/6000 β i IP 30/6000 βi IP 40/6000
Specification 1442 1442 1442 1443 1443 1443 1459 1459 1499 1480
Applicable amplifier βi SVSP*-11 βi SVSP*-15 βi SVSP*-18 βi SVSP*-11 βi SVSP*-15 βi SVSP*-18 βi SVSP*-15 βi SVSP*-18 β i SVSP*-18 βi SVSP*-18
Model code 350 351 354 353 352 355 356 357 358
Applicable software series and edition 9D50/U 9D50/Q 9D8A/A 9D50/U 9D50/Q 9D8A/A 9D5A/N, 9D8A/A 9D8A/A 9D8A/A 9D9A/A
7.5kW 7.5kW 7.5kW 9kW 9kW 9kW 11kW 11kW 15kW 15kW
Continuous rated output -1 -1 -1 -1 -1 -1 -1 -1 -1 -1
1200/6000min 1200/6000min 1200/6000min 1000/6000min 1000/6000min 1000/6000min 1000/6000min 1000/6000min 1000/6000min 650/6000min
9kW 9kW 9kW 11kW 11kW 11kW 15kW 15kW 18.5kW 18.5kW
S2 15 min rated output -1 -1 -1 -1 -1 -1 -1 -1 -1 -1
750/6000min 750/6000min 750/6000min 750/6000min 750/6000min 750/6000min 750/6000min 750/6000min 1500/6000min 650/6000min
FS30i /FS0i
4007 00000000 ← ← 00000000 ← ← 00000000 ← 00000000 0
4008 00010000 ← ← 00010000 ← ← 00010000 ← 00010000 10000
4009 00000000 ← ← 00000000 ← ← 00000000 ← 00000000 0
4010 00010000 ← ← 00010000 ← ← 00010000 ← 00010000 10000
4011 00001010 ← ← 00001010 ← ← 00001010 ← 00001010 1010
4012 10000000 ← ← 10000000 ← ← 10000000 ← 10000000 10000000
4013 00001100 ← ← 00001100 ← ← 00001100 ← 00001100 1100
4019 00000100 ← ← 00000100 ← ← 00000100 ← 00000100 100
4020 6000 ← ← 6000 ← ← 6000 ← 6000 6000
4023
4039 0 ← ← 0 ← ← 0 ← 0 0
4040
4041
4048
4049
4080 20575 ← ← 21845 ← ← 19275 ← 16730 16228
4083 30 ← ← 30 ← ← 30 ← 30 30
4093 0 ← ← 0 ← ← 0 ← 0 0
4100 750 ← ← 750 ← ← 770 ← 750 670
4101 79 ← ← 79 ← ← 100 ← 100 72
4102 1566 ← ← 1191 ← ← 953 ← 1007 775
4103 0 ← ← 0 ← ← 0 ← 0 0
4104 2000 ← ← 3000 ← ← 4000 ← 3500 6500
4105 0 ← ← 0 ← ← 0 ← 0 0
4106 7000 ← ← 7000 ← ← 9000 ← 8000 7500
4107 0 ← ← 0 ← ← 0 ← 0 0
4108 0 ← ← 0 ← ← 0 ← 0 0
4109 25 ← ← 25 ← ← 25 ← 25 25
4110 943 1415 1886 793 1190 1586 1077 1436 1143 849
4111 503 ← ← 410 ← ← 333 ← 334 299
4112 200 ← ← 200 ← ← 200 ← 200 200
4113 228 ← ← 268 ← ← 300 ← 300 193
4114 0 ← ← 0 ← ← 20480 ← 0 0
4115 100 ← ← 100 ← ← 100 ← 100 100
4116 5307 ← ← 4194 ← ← 4408 ← 4298 4983
4117 90 ← ← 90 ← ← 90 ← 90 90
4118 100 ← ← 100 ← ← 100 ← 100 100
4119 42 ← ← 36 ← ← 32 ← 32 49
4120 0 ← ← 0 ← ← 0 ← 0 0
4124 0 ← ← 0 ← ← 0 ← 0 0
4127 132 ← ← 134 ← ← 150 ← 136 136
4128 90 ← ← 105 ← ← 103 ← 0 108
4129 0 ← ← 0 ← ← 0 ← 0 0
4130 25700 ← ← 25700 ← ← 25700 ← 25700 25700
4134 130 ← ← 130 ← ← 130 ← 130 130
4136 0 ← ← 0 ← ← 0 ← 0 0
4138 0 ← ← 0 ← ← 0 ← 0 0
4139 0 ← ← 0 ← ← 0 ← 0 0
4140 0 ← ← 0 ← ← 0 ← 0 0
4141 0 ← ← 0 ← ← 0 ← 0 0
4142 0 ← ← 0 ← ← 0 ← 0 0
4143 0 ← ← 0 ← ← 0 ← 0 0
4144 0 ← ← 0 ← ← 0 ← 0 0
4145 0 ← ← 0 ← ← 0 ← 0 0
4146 0 ← ← 0 ← ← 0 ← 0 0
4147 0 ← ← 0 ← ← 0 ← 0 0
4148 0 ← ← 0 ← ← 0 ← 0 0
4149 0 ← ← 0 ← ← 0 ← 0 0
4150 0 ← ← 0 ← ← 0 ← 0 0
4151 0 ← ← 0 ← ← 0 ← 0 0
4152 0 ← ← 0 ← ← 0 ← 0 0
4153 0 ← ← 0 ← ← 0 ← 0 0
4154 0 ← ← 0 ← ← 0 ← 0 0
4155 0 ← ← 0 ← ← 0 ← 0 0
4156 0 ← ← 0 ← ← 0 ← 0 0
4158 0 ← ← 0 ← ← 0 ← 0 0
4159 0 ← ← 0 ← ← 0 ← 0 0
4161 0 ← ← 0 ← ← 0 ← 0 0
4165 0 ← ← 0 ← ← 0 ← 0 0
4166 0 ← ← 0 ← ← 0 ← 0 0
4169 0 ← ← 0 ← ← 0 ← 0 0
Maximum output
9.9kW 9.9kW 9.9kW 12.1kW 12.1kW 12.1kW 16.5kW 16.5kW 20.4kW 20.4kW
during acceleration
- 102 -
A.PARAMETER TABLE
B-65312EN/04 APPENDIX FOR EACH MOTOR MODEL
(*1) This setting is applied to when the position coder is attached to the spindle.
When using the αiBZ sensor, set bits 3, 2, 1, 0 of parameter No. 4002 to 0, 0, 1, 1,
respectively, and set bits 7, 6, 5, 4 of parameter No. 4003 or parameter No. 4361
depending on the number of sensor teeth.
(*2) Since these values are the standard values for the motor alone, they need to be
changed as shown below depending on the load state of an actual machine.
Setting = (machine load inertia/motor inertia + 1) * standard value of motor alone
- 103 -
B.LOADMETER (DYNAMOMETER) APPENDIX B-65312EN/04
B LOADMETER (DYNAMOMETER)
The loadmeter (dynamometer) shows the percentage of the load (load factor) to the maximum output that
the motor can produce. At the maximum output, 10 V is output. It is output on pin 16 of the JY1
connector of the amplifier. (For details, refer to "FANUC SERVO AMPLIFIER βi series Descriptions"
(B-65322EN).) Two types of loadmeter are available : Load meter (Normalized by max. output) and Load
meter (Normalized by cont. rated output). (For details, refer to technical report (B-65280EN/08-015) , or
ask FANUC.)
Example
- Load meter (Normalized by max. output)
S2 60-minute, Red
S3 40% rating Excess of rated output
White
S1 Continuous rating
Motor
speed
(min-1)
0
0 10
S2 60-minute, Red
S3 40% rating Excess of rated output
White
S1 Continuous
Motor rating
speed
(min-1)
0
0 10
- 104 -
B-65312EN/04 APPENDIX B.LOADMETER (DYNAMOMETER)
10000 6.7
S2 15-minute,
S3 25% rating
Load meter (Normalized by
4500
max. output)
2000
1500
0
0 4.6 6.1 9.1 10
S2 60-minute,
S3 40% rating
6.3 6.9
10000
S2 15-minute,
S3 25% rating
Load meter (Normalized by
cont. rated output) 4500
2000
1500
0
0 4.6 6.8 9.1 10
S2 60-minute, 6.1 7.5
S3 40% rating
βiI 6/10000
6.1
10000 S2 15-minute,
4
S3 25% rating
Load meter (Normalized by
max. output) 4500
2000
1500
0
0 S2 60-minute,5.0 6.7 9.1 10
S3 40% rating
7.4 8.2
10000
S2 15-minute,
Load meter (Normalized by S3 25% rating
cont. rated output) 4500
2000
1500
0
0 S2 60-minute, 5.0 7.5 9.1 10
S3 40% rating 6.7 6.8
βiI 8/10000
10000 S2 15-minute,
S3 25% rating
Load meter (Normalized by
max. output)
2000
1500
0
0 S2 60-minute, 4.6 6.2 9.1 10
S3 40% rating
10000
S2 15-minute,
Load meter (Normalized by S3 25% rating
cont. rated output)
2000
1500
0
0 S2 60-minute, 4.6 6.8 9.1 10
S3 40% rating 6.2 7.5
- 105 -
B.LOADMETER (DYNAMOMETER) APPENDIX B-65312EN/04
βiI 12/8000
8000 7.9
S2 15-minute,
Load meter (Normalized by S3 25% rating
max. output) 3500
2000
1500
0
0 5.0 6.7 9.1 10
S2 60-minute,
S3 40% rating
βiI 15/7000
7.4
7000
S2 15-minute,
Load meter (Normalized by S3 25% rating
max. output) 3500
2000
1500
00
5.5 7.4 9.1 10
S2 60-minute,
S3 40% rating
6.8
7.4
7000
S2 15-minute,
Load meter (Normalized by S3 25% rating
cont. rated output) 3500
2000
1500
0
0 5.5 9.1 10
S2 60-minute, 6.8 7.4 7.5
S3 40% rating
- 106 -
B-65312EN/04 APPENDIX B.LOADMETER (DYNAMOMETER)
βiIP 15/6000
6000 S2 15-minute,
S3 25% rating
Load meter (Normalized by
max. output)
1200
750
0
0 4.7 7.6 9.1 10
S2 60-minute rating
6000
S2 15-minute,
S3 25% rating
Load meter (Normalized by
cont. rated output)
1200
750
0
0 S2 60-minute 4.7 6.3 7.6 9.1 10
rating 5.7
βiIP 18/6000
7.6
6000
5000 S2 15-minute,
Load meter (Normalized by S3 25% rating
max. output)
1000
750
0
0 5.6 7.4 9.1 10
S2 60-minute rating
6.7 7.4
6000
5000
S2 15-minute,
Load meter (Normalized by S3 25% rating
cont. rated output)
1000
750
0
0 5.6
S2 60-minute rating 7.5 9.1 10
6.8 7.4
- 107 -
B.LOADMETER (DYNAMOMETER) APPENDIX B-65312EN/04
βiIP 22/6000
6000
S2 15-minute,
Load meter (Normalized by S3 25% rating
max. output)
1000
750
0
0 5.0 6.7 9.1 10
S2 60-minute rating
6.8 7.5
6000
S2 15-minute,
Load meter (Normalized by
S3 25% rating
cont. rated output)
1200
750
0
0 5.0 6.7 9.1 10
S2 60-minute rating
βiIP 30/6000
7.6
6000
S2 60-minute,
Load meter (Normalized by S3 40% rating
max. output) 3000
1000
750
0
0 5.5 7.4 9.1 10
S2 15-minute,
S3 25% rating
6.6 7.3
6000
S2 15-minute,
Load meter (Normalized by S3 25% rating
cont. rated output) 3000
1000
750
0
0 5.5 9.1 10
S2 60-minute rating 6.8 7.4 7.5
βiIP 40/6000
5.8
6000
S2 15-minute,
Load meter (Normalized by S3 40% rating
3000
max. output)
0
0 7.4 9.1 10
9.1 10
6000
0
0 5.8 7.8
7.1
- 108 -
B-65312EN/04 APPENDIX B.LOADMETER (DYNAMOMETER)
βiIC 6/6000
7.3
6000
S2 15-minute rating
Load meter (Normalized by 4000
max. output)
2000
1500
0 S2 60-minute
0 5.0 6.7 9.1 10
rating
6.3
6.9
6000 S2 15-minute rating
βiIC 8/6000
7.3
6000
S2 15-minute rating
Load meter (Normalized by 4000
max. output) 2000
1500
0 S2 60-minute
0 4.6 6.2 9.1 10
rating
5.8
6.4
6000 S2 15-minute rating
- 109 -
B-65312EN/04 INDEX
INDEX
Model βiI 15/7000 .........................................................17
<β > Model βiI 3/10000 .........................................................13
βiI series..................................................................13,105 Model βiI 6/10000 .........................................................14
βiIC series................................................................24,109 Model βiI 8/10000 .........................................................15
βiIP series ................................................................18,107 Model βiIC 3/6000 .........................................................24
Model βiIC 6/6000 .........................................................25
<A> Model βiIC 8/6000 .........................................................26
About Characteristic Curves and Data Sheet ...................7 Model βiIP 12/6000 .......................................................18
Allowable radial load ......................................31,37,43,49 Model βiIP 15/6000 .......................................................19
AMBIENT TEMPERATURE, HUMIDITY, Model βiIP 18/6000........................................................20
INSTALLATION HEIGHT, AND VIBRATION ......87 Model βiIP 22/6000........................................................21
APPROVED SPECIFICATIONS ..................................64 Model βiIP 30/6000 .......................................................22
Axial run-out accuracy....................................32,38,44,49 Model βiIP 40/6000 ..................................................23,46
Models βiI 15/7000, βiIP 15/6000, βiIP 18/6000, βiIP
<B> 22/6000, βiIP 30/6000................................................40
BUILT-IN DETECTOR.................................................53 Models βiI 3/10000, βiI 6/10000, βiIC 3/6000, βiIC
6/6000.........................................................................28
<C> Models βiI 8/10000, βiI 12/8000, βiIP 12/6000, βiIC
CAUTION.....................................................................s-3 8/6000.........................................................................34
CAUTION LABEL .......................................................s-6 MOTOR HANDLING ...................................................73
CHECKING A DELIVERED SPINDLE MOTOR MOTOR INSTALLATION ...........................................75
AND STORING A SPINDLE MOTOR.....................73 MOTOR LINEUP ............................................................3
COMMON .....................................................................81 MOTOR SPECIFICATIONS...........................................6
CONDITIONS FOR APPROVAL RELATED TO MOTOR TYPES ............................................................66
THE IEC60034 STANDARD ....................................63
CONNECTING A SPINDLE MOTOR .........................61 <N>
CONNECTION..............................................................53 NOTE............................................................................ s-4
Connection of Power Line..............................................61 NOTES ON INSTALLATION ......................................81
Connection of Signal Lines ............................................62 NOTES ON OPERATION.............................................94
COOLING FAN.............................................................51
Cooling Fan Connection.................................................51 <O>
Cooling Fan Specifications ............................................51 ORDERING SPECIFICATION NUMBER.....................4
CURVES AND DATA SHEET .......................................7 OUTLINE ......................................................................53
<D> <P>
DEFINITION OF WARNING, CAUTION, AND PARAMETER TABLE FOR EACH MOTOR MODEL
NOTE ........................................................................s-1 ....................................................................................97
Details of Cable K14......................................................54 Power terminal arrangement ........................... 33,39,45,50
Details of Cable K17......................................................56 PREFACE .................................................................... p-1
DETERMINING THE ACCELERATION TIME .........68
DETERMINING THE RMS OUTPUT .........................70 <S>
SAFETY PRECAUTIONS ........................................... s-1
<E> SELECTING MOTOR SPECIFICATIONS
EXTERNAL DIMENSIONS .....................27,28,34,40,46 ACCORDING TO THE SPINDLE STRUCTURE .66
SEPARATING AND DISPOSING OF A SPINDLE
<F> MOTOR .....................................................................74
FEATURES .....................................................................3 Shaft figure ..................................................... 30,36,42,48
For the spindle motor with αiM sensor ..........................54 SPINDLE MOTOR SELECTION CONDITIONS ........67
For the spindle motor with αiMZ sensor........................56 SPINDLE MOTOR βiI series ........................................98
SPINDLE MOTOR βiIC series ....................................103
<L> SPINDLE MOTOR βiIP series.....................................101
LINEUP OF THE SERIES...............................................3
LOADMETER (DYNAMOMETER) ..........................104 <T>
TERMS ............................................................................6
<M> TYPE AND SPECIFICATION METHOD....................53
Model βiI 12/8000 .........................................................16 TYPES OF MOTORS TO BE APPROVED..................63
i-1
INDEX B-65312EN/04
<U>
USAGE CONSIDERING ENVIRONMENTAL
RESISTANCE............................................................88
<W>
WARNING ...................................................................s-2
WHEN A MOTOR IS CONNECTED TO A SPINDLE
VIA A BELT ..............................................................75
WHEN A MOTOR IS CONNECTED TO A SPINDLE
VIA A GEAR .............................................................78
WHEN A MOTOR IS DIRECTLY CONNECTED TO
A SPINDLE VIA A COUPLING...............................79
-2-
B-65312EN/04 REVISION RECORD
REVISION RECORD
Edition Date Contents
• Renovation of the overall configuration
04 Nov., 2014 • Addition of following model
βiIP 40/6000
• Changing of model names of following series
βiI 15/7000, βiIP 22/6000, βiIP 30/6000
03 Apr., 2012
• Addition of following series
βiIC series
• Changing of model names of following series
βiI series
02 Jul., 2007
• Addition of following series
βiIP series
01 May, 2003
r-1
B-65312EN/04
* B - 6 5 3 1 2 E N / 0 4 *