0% found this document useful (0 votes)
32 views2 pages

Model 6600 M4 Datasheet

The 6600-M4 Automated Pitot Static Tester has three outputs that can test the entire pitot and static system of an aircraft. It has high accuracy that meets RVSM requirements and requires calibration only once per year. Using profiles, the remote control unit allows the operator to run through a test with only one keypress. The tester includes integrated pumps and valves to simulate pressure and can be operated from inside the aircraft cockpit.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
32 views2 pages

Model 6600 M4 Datasheet

The 6600-M4 Automated Pitot Static Tester has three outputs that can test the entire pitot and static system of an aircraft. It has high accuracy that meets RVSM requirements and requires calibration only once per year. Using profiles, the remote control unit allows the operator to run through a test with only one keypress. The tester includes integrated pumps and valves to simulate pressure and can be operated from inside the aircraft cockpit.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Model 6600-M4 Automated Pitot Static Tester - 3 Outputs (Hi-range)

The 6600-M4 Automated Tester is ideal for use on aircraft with "Smart Probes" capable of measuring AOA using Air Data. The
tester has one Static output (Ps1), one Pitot output (Pt) and a third output (Ps2) which can be used to simulate either AOA or
AOS. Using the small and light-weight Remote unit a user can operate the tester from the cockpit and test the entire pitot and
static system of the aircraft. The tester includes built-in vacuum and pressure pumps and emergency manual bleed-down
valves. The high accuracy of this unit meets all RVSM requirements. Also, it requires no maintenance other than to be
calibrated only once a year. The use of “Profiles” makes it possible for the operator to run through a test using only a single
key on the Remote unit.
Specifications
Ps1 Output “Jog” feature
Pressure function Allows set-point to be increased or decreased in steps of 1
range: 0.1 to 42 inHg foot or 0.1 knots simply by using arrow keys.
resolution: 0.0001 inHg
accuracy: 0.002 inHg “Profiles” feature
Altitude function A profile of the standard set-points of an altimeter check or
range: -4000 ft. to 80,000 ft. airspeed check can be downloaded from a computer. Such a
resolution: 1 foot profile allows the user to operate the unit using a single key. Up
accuracy: 2 ft. @ 0 ft; to 12 such profiles can be stored in the unit. PC-based software
6 ft. @ 35,000 ft. is included.
12 ft. @ 50,000 ft.
50 ft. @ 80,000 ft
Climb function Pressure & Vacuum system
range: 0 ft/min to 50,000 ft/min The tester includes separate pressure and vacuum
resolution: 1 ft/min diaphragm pumps for higher reliability. The pressure system
accuracy: 1% of rate of climb includes a membrane dryer, and a filter to provide clean dry air
Displayed units: Feet, meters, inHg, mbar for the entire system.

Remote unit
Ps2 Output
The Remote unit is the operator interface for the tester. It
Pressure function: Same as for Ps1 Output
is small and light enough to be used in the cockpit. The tester
Altitude function: Same as for Ps1 Output can be turned On and Off from the Remote. All valid
Climb function: Same as for Ps1 Output parameters, including altitude, climb and airspeed, are clearly
Airspeed function: displayed simultaneously on a single screen on the Remote.
range: 0 to 500 knots
resolution: 0.1 knots Manual Vent
accuracy: 0.3 knots @ 50 knots The tester includes manual metering valves to enable the
0.16 knots @ 100 knots system (aircraft) to be manually vented in the event of loss of
0.05 knots @ 500 knots power.
Displayed units: inHg, mbar, Dfin, Dfmb,
Power requirement
Feet, meters, knots, kmph
90-260 VAC, 47-440 Hz ; 240 VA (350VA with heaters on)
Pt Output
Pressure function Interfaces
range: 0.1 to 100 inHg RS232 Standard; IEEE-488 & Encoder optional
resolution: 0.0001 inHg
accuracy: 0.003 inHg Dimensions & weights
Main unit: 22” x 14” x 9” / 46 lbs
Airspeed function
range: 0 to 1000 knots Remote unit: 7” x 8” x 2” / 1 lb.
resolution: 0.1 knots Environmental specs:
accuracy: 0.5 knots @ 50 knots o o
Operating temp. 0 to 50 C
0.25 knots @ 100 knots o o
0.05 knots @ 650 knots Storage temp. -25 to 75 C
0.01 knots @ 1000 knots Humidity: 5 to 100%
Mach function
range: 0.0 to 5.0 Mach
resolution: 0.001 Mach
accuracy: 0.001 above 0.2 Mach Specifications subject to change without notice
Displayed units: knots, Mach, kmph, mph, EPR, 10/13
inHg, mbar, Qcin, Qcmb

Phone: (800) 285-7337


(281) 325-8300
Fax: (281) 325-8399
Sugar Land, TX Web: www.laversab.com