ACI Deflection

This document contains calculations of deflection for two building components according to ACI 318M-99. For the first component, the calculated short-term deflection due to live load was within acceptable limits. However, for a roof supporting nonstructural elements, the total deflection may be too high. For the second component, the calculated deflections were higher. The total short-term and long-term deflection would be too great for a roof supporting nonstructural elements.

Uploaded by

muhanned
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
73 views4 pages

ACI Deflection

This document contains calculations of deflection for two building components according to ACI 318M-99. For the first component, the calculated short-term deflection due to live load was within acceptable limits. However, for a roof supporting nonstructural elements, the total deflection may be too high. For the second component, the calculated deflections were higher. The total short-term and long-term deflection would be too great for a roof supporting nonstructural elements.

Uploaded by

muhanned
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

Project No.

Date

General 28/4/02
DESIGN CALCULATION
SHEET Sheet No. Computed by

of -- A. HASHEM
Checked by Approved by
Subject Checking
_ _
Building Test1

Calculation of Deflection According to ACI 318M-99


Concrete Compressive Strength (f'c) = 200.00 Kg/cm2 = 20.00 MPa
Concrete Modulus of Rupture (fr) = 3.13 MPa (Eq. 9-9)
Concrete Modulus of Elasticity (Ec) = 2.1E+04 MPa (Clause 8.5.1)
n (Es/Ec) = 9.52 (Clause 8.5.2)
Section Properties
Thickness of Section (t) = 32.00 cm Depth of Ten. Reinforcement (d) = 28.60 cm
Breadth of Section (b) = 140.00 cm Depth of Comp. Reinforcement (d') = 3.40 cm
Tension Reinforcement (As) = 44.22 cm 2 Compression Reinforcement (As') = 20.10 cm2
Span (l) = 7.00 m
Nutral Axis Depth (z) = 9.85 cm
Gross Moment of Inertia (Ig) = 382293.33 cm4 = 3.82E+09 mm4
Cracked Moment of Inertial (Icr) = 199642.40 cm 4 = 2.00E+09 mm4
Cracking Moment (Mcr) = 7.48E+07 N mm = 7.48 m. t (Eq. 9-8)
Service Straining Actions
Bending Moment Due to Dead Load only (Md) = 23.60 m.t = 2.4E+08 N. mm
Bending Moment Due to Live Load only (Ml) = 3.40 m.t = 3.4E+07 N. mm
% of Sustained Load from the Live Load = 25%
% of Gross Inertia Used in Calculation = 100%
Bending Moment Due to Sustained Load (Msus) = 24.45 m.t = 2.4E+08 N. mm
Calculated Short Time Deflection (Calculated by total or percentage of gross moment of inertia)
Deflection due to Dead Load (Di)d = 0.6000 cm = 6.000 mm
Deflection due to Live Load (Di)l = 0.4000 cm = 4.000 mm
Efffective Moment of Inertia (Eq. 9-7)
Under Dead Load Only (Ie)d = 205457.47 cm4 = 2.05E+09 mm4
Under Sustained Load (Ie)sus = 204871.83 cm4 = 2.05E+09 mm4
Under Dead + Live Load (Ie)d+l = 203525.689 cm4 = 2.04E+09 mm4
Modified Short time Deflection
Deflection due to Dead Load (Di)d = 1.1164 cm
Deflection due to Sustained Load (Di)sus = 1.3062 cm
Deflection due to Dead + Live Load (Di)d+l = 1.8784 cm
Deflection due to Live Load (Di)l = 0.7619 cm
Additional Long Term Deflection (Clause 9.5.2.5)
For 5 years or more (Dlong) = 2.08826 cm For 12 months (Dlong) = 1.46179 cm
For 6 months (Dlong) = 1.25296 cm For 3 months (Dlong) = 1.04413 cm

Results
-- Flat roofs not supporting and not attached to nonstructural elements likely to be damaged by large defelections:
(Di)l = 0.7619 cm < l/180 = 3.8889 cm
-- Floors not supporting and not attached to nonstructural elements likely to be damaged by large deflections:
(Di)l = 0.7619 cm < l/360 = 1.9444 cm
-- Roof or floor construction supporting or attached to nonstructural elements likely to be damaged by
large deflections:
(Dlong) + (Di)l = 2.8502 cm > l/480 = 1.45833 cm
-- Roof or floor construction supporting or attached to nonstructural elements not likely to be damaged by

622622985.xls - Rev. 0 Rectangular Section


large deflections:
(Dlong) + (Di)l = 2.8502 cm < l/240 = 2.9167 cm

622622985.xls - Rev. 0 Rectangular Section


Project No. Date

General 28/4/02
DESIGN CALCULATION
SHEET Sheet No. Computed by

of -- A. HASHEM
Checked by Approved by
Subject Checking
_ _
Building Test2

Calculation of Deflection According to ACI 318M-99


Concrete Compressive Strength (f'c) = 210.00 Kg/cm2 = 21.00 MPa
Concrete Modulus of Rupture (fr) = 3.21 MPa (Eq. 9-9)
Concrete Modulus of Elasticity (Ec) = 2.2E+04 MPa (Clause 8.5.1)
n (Es/Ec) = 9.29 (Clause 8.5.2)
Section Properties
Thickness of Section (t) = 40.00 cm Depth of Ten. Reinforcement (d) = 28.60 cm
Breadth of Wib (bw) = 30.00 cm Depth of Comp. Reinforcement (d') = 2.50 cm
Breadth of Flange (bf) = 60.00 cm Flange Thickness (tf) = 7.00 cm
Tension Reinforcement (As) = 6.03 cm 2 Compression Reinforcement (As') = 2.26 cm2
Span (l) = 7.00 m
Nutral Axis Depth (z) = 6.29 cm
Gross Moment of Inertia (Ig) = 209514.95 cm4 = 2.10E+09 mm4
Cracked Moment of Inertial (Icr) = 33116.24 cm 4 = 3.31E+08 mm4
Cracking Moment (Mcr) = 2.99E+07 N mm = 2.99 m. t (Eq. 9-8)
Service Straining Actions
Bending Moment Due to Dead Load only (Md) = 3.80 m.t = 3.8E+07 N. mm
Bending Moment Due to Live Load only (Ml) = 0.49 m.t = 4.9E+06 N. mm
% of Sustained Load from the Live Load = 30%
% of Gross Inertia Used in Calculation = 100%
Bending Moment Due to Sustained Load (Msus) = 3.9519 m.t = 4.0E+07 N. mm
Calculated Short Time Deflection (Calculated by total or percentage of gross moment of inertia)
Deflection due to Dead Load (Di)d = 1.0000 cm = 10.000 mm
Deflection due to Live Load (Di)l = 0.5000 cm = 5.000 mm
Efffective Moment of Inertia (Eq. 9-7)
Under Dead Load Only (Ie)d = 118948.91 cm4 = 1.19E+09 mm4
Under Sustained Load (Ie)sus = 109722.54 cm4 = 1.10E+09 mm4
Under Dead + Live Load (Ie)d+l = 92795.4631 cm4 = 9.28E+08 mm4
Modified Short time Deflection
Deflection due to Dead Load (Di)d = 1.7614 cm
Deflection due to Sustained Load (Di)sus = 2.1959 cm
Deflection due to Dead + Live Load (Di)d+l = 3.3867 cm
Deflection due to Live Load (Di)l = 1.6253 cm
Additional Long Term Deflection (Clause 9.5.2.5)
For 5 years or more (Dlong) = 3.88074 cm For 12 months (Dlong) = 2.71652 cm
For 6 months (Dlong) = 2.32845 cm For 3 months (Dlong) = 1.94037 cm

Results
-- Flat roofs not supporting and not attached to nonstructural elements likely to be damaged by large defelections:
(Di)l = 1.6253 cm < l/180 = 3.8889 cm
-- Floors not supporting and not attached to nonstructural elements likely to be damaged by large deflections:
(Di)l = 1.6253 cm < l/360 = 1.9444 cm
-- Roof or floor construction supporting or attached to nonstructural elements likely to be damaged by
large deflections:
(Dlong) + (Di)l = 5.5061 cm > l/480 = 1.45833 cm

622622985.xls - Rev. 0 T - Section


-- Roof or floor construction supporting or attached to nonstructural elements not likely to be damaged by
large deflections:
(Dlong) + (Di)l = 5.5061 cm > l/240 = 2.9167 cm

622622985.xls - Rev. 0 T - Section