0% found this document useful (0 votes)
74 views12 pages

Maintenance Report Lumut OCT 22

This document provides a maintenance report for lifts in various apartment blocks from April to October 2022. It includes breakdown statistics which show that Lift Block A3-E had the highest number of reported breakdowns. The report also includes a detailed breakdown report listing the date, problem, cause, and status for each lift issue. Common problems included dirt interfering with doors, door roller and contact issues, and sensor errors. Repairs such as adjustments, replacements, and cleaning were needed to resolve the issues and return the lifts to normal operation.

Uploaded by

faizbukhari
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views12 pages

Maintenance Report Lumut OCT 22

This document provides a maintenance report for lifts in various apartment blocks from April to October 2022. It includes breakdown statistics which show that Lift Block A3-E had the highest number of reported breakdowns. The report also includes a detailed breakdown report listing the date, problem, cause, and status for each lift issue. Common problems included dirt interfering with doors, door roller and contact issues, and sensor errors. Repairs such as adjustments, replacements, and cleaning were needed to resolve the issues and return the lifts to normal operation.

Uploaded by

faizbukhari
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

JABATAN KERJA RAYA MALAYSIA

KERJA-KERJA PENGGANTIAN 29 UNIT LIF DAN LAIN-LAIN


KERJA BERKAITAN DI APARTMENT A,
PANGKALAN TLDM LUMUT, PERAK

NO. KONTRAK: JKR – CKM / 41 / 2019 ( T-BPPP&KB )

LAPORAN PENYELENGGARAAN
APRIL ~ OCTOBER 2022

KONTRAKTOR

FESMA SDN BHD


71-1, JALAN SBC 1,
TAMAN SRI BATU CAVES,
68100 BATU CAVES, SELANGOR
R
CONTENT
1. INTRODUCTION 1

2. BREAKDOWN STATISTIC 2

3. DETAIL BREAKDOWN REPORT 4

4. PMA RECORDS 6

5. LIST OF DEFECTS 7
1.0 INTRODUCTION

Maintenance is an activity that has been implemented to preserve and maintain the facilities
and the environment as per contract 1 years of free maintenance will be provided for all new
lift that has been replaced. Any breakdown will be incurred by this contractor during DLP
period.

The reason for maintenance are:


• To make sure the tools are functioning continuously and safe to use.
• To maintain and extend the tools life spans
• To increase the performance
• To reduce damage
• To guarantee the client’s safety

Maintenance of lift system for this project includes 30 units lifts at 15 different apartments
building which are A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12, A13, A14, A25
and A26.
2.0 BREAKDOWN STATISTIC
As a conclusion, referring to monthly report DLP period started in April until October and as per
October there are breakdown report that has been reported. Lift Block A3-E are the highest
frequent breakdown.
BREAKDOWN SERVICE SHEET OCTOBER
LIST OF PMA NUMBERS

SENARAI PMA

LIF NO PMA Tarikh Tamat


A1-E PK PMA 82150 12/31/2022
A1-O PK PMA 81933 5/31/2022
A3-E PK PMA 82151 12/31/2022
A3-O PK PMA 81931 5/31/2022
A4-E PK PMA 82152 12/31/2022
A4-O PK PMA 81932 5/31/2022
A5-E PK PMA 82214 2/9/2023
A5-O PK PMA 81936 6/3/2022
A6-E PK PMA 82215 2/9/2023
A6-O PK PMA 81953 6/16/2022
A7-E PK PMA 82216 2/9/2023
A7-O PK PMA 81934 6/4/2022
A8-E PK PMA 82204 2/9/2023
A8-O PK PMA 81935 6/3/2022
A9-E PK PMA 82329 6/1/2023
A9-O PK PMA 81980 6/29/2022
A10-E PK PMA 82208 2/10/2023
A10-O PK PMA 81981 6/29/2022
A11-E PK PMA 82209 2/10/2023
A11-O PK PMA 81982 6/29/2022
A12-E PK PMA 82153 12/31/2022
A12-O PK PMA 81951 6/16/2022
A13-E PK PMA 81952 6/16/2022
A13-O PK PMA 82142 12/28/2022
A14-E PK PMA 82143 12/28/2022
A14-O PK PMA 82331 6/1/2023
A25-E PK PMA 82145 12/28/2022
A26-E PK PMA 82144 12/28/2022
A26-O PK PMA 82330 6/1/2023
3.0 DETAIL BREAKDOWN REPORT

BLOCK FREQUENCY DATE PROBLEM CAUSE STATUS

1)LIFT STUCK 1)CAR DOOR ROLLER MISSING 1)LIFT RUN BACK TO NORMAL
7/5/22
2) LIFT STOP AT LVL 2 TRACK DUE TO CLOSE & OPEN 2)LIFT STOP FOR FUTHER REPAIR
A1-O 3 14/7/22
3) CAR DOOR CANNOT WITH FORCED 3)READJUST CAR DOOR .LIFT RUN
29/7/22
CLOSE 2) CAR DOOR MISS TRACK BACK TO NORMAL
3) SYSTEM ERROR
RESET AND LIFT RUN BACK TO
A1-E 1 18/7/22 LIFT STOP AT LVL 4 FOUND DIRT ON CAR DOOR SILL
NORMAL

1)LIFT RUN BACK TO NORMAL


1LANDIND DOOR OPEN 2)RESET AND LIFT RUN BACK TO
1)LANDING DOOR LVL 4 BAD
1/4/22 AND CLOSE AT LVL 4 NORMAL
CONTACT
13/4/22 2)LIFT STOP 3)RESET AND LIFT RUN TO
2)DOOR OPERATOR PROBLEM
24/6/22 3)LIFT STOP LVL 8 NORMAL
3)BRAKE SWITCH 2 ERROR
A3-E 7 29/7/22 4) LIFT STOP AT LVL 1 4) REPLACE NEW CONTACT
4) CAR DOOR CONTACT BROKEN
3/8/22 5) LIFT STOP AT GROUND 5) LIFT RUN BACK TO NORMAL
5) RESET LIFT
4/8/22 FLOOR 6) READJUST SWITCH AND LIFT
6) CAR TRAP DOOR BAD CONTACT
19/10/22 6) LIFT STOP RUN BACK TO NORMAL
7) MISS CONTACT
7) Mantrap 7) READJUST DOOR CONTACT LIF
RUN BACK TO NORMAL

1/4/22 1)DOOR OPEN AND CLOSE 1)FOUND DIRT ON DOOR TRACK REMOVE DIRT LIFT RUN BACK TO
A4-O 2
21/4/22 2)LIFT STOP AT LVL 9 2)DIRT ON LANDING DOOR SILL NORMAL

REMOVE DIRT AND LIFT RUN


A6-E 1 4/4/22 LIFT STOP AT LVL 6 DIRT ON DOOR TRACK BACK TO NORMAL

ADJUST ROPE SWTCH LIFT RUN


A9-O 1 15/4/22 LIFT STOP AT LVL 9 FRW ENC SPEED BACK TO NORMAL

1)LIFT SHUTDOWN AT LVL


1)BRAKE SWITCH 2 NOT OPEN
G WITH DOOR CLOSE
A9-E 2 15/4/22 2)LANDING DOOR CAM ROLLER 1)ADJUST BRAKE SWITCH 2 LIFT
POSITION
28/4/22 BROKEN AT LEVEL G RUN BACK TO NORAM
2)LIFT STOP AT LVL G
2)REPLACE NEW DOOR CAM
ROLLER AND LIFT RUN BACK TO
NORMAL

1)LIFT STOP AT LVL 3 IN 2) 1)FOUND DIRT IN CAR AND 2) REMOVE DIR LIFT RUN BACK TO
A10-O 1 21/4/22
DOOR OPEN POSITION LANDING DOOR SEAL. NORMAL

1)ADJUST BRAKE SWITCH AND


LIFT RUN TO NORMAL
28/4/22 1)MANTRAP -
A10-E 2 2)UNIT SHUTDOWN WAITING FOR
1/5/22 2)LIFT STOP OPERATE 2)BRAKE SWITCH 1 BROKEN
REPLACEMENT

LIFT SHUTDOWN WAITING FOR


1)LIFT STOP AT LVL 7 IN
A11-O 1 26/6/22 LEVELING SENSOR ERROR REPLACEMENT PART
DOOR CLOSE POSITION
RUNNING ON ARRIVAL
A11-E 1 24/4/22 - -
REPLACE DOOR ROLLER ,
WAITING FOR FUTHER REPAIR
A12-0 1 13/10/22 MANTRAP CONTACTOR LIF RUN BACK TO
DUE TO VANDALISM
NORMAL

1)REMOVE DIRT LIFT RUN BACK


TO NORMAL
24/4/22 1)LIFT STOP AT LVL G 1)DIRT ON LANDING DOOR SILL 2)ADJUST DOOR LOCK LIFT RUN
A14-O 3 3/5/22 2)LIFT STOP OPERATE 2)CAR DOOR LOCK MISS CONTACT BACK TO NORMAL
3) LIFT STOP AT LVL 3 3) LEVELING SENSOR ERROR 3) REPLACE NEW PART. LIFT RUN
BACK TO NORMAL ON 15/7/22

1)REMOVE DIRT LIFT RUN BACK


TO NORMAL
24/4/22 1)LIFT STOP AT LVL 6 1)DIRT ON LANDING DOOR SILL
3)RUNNING ON ARRIVAL
3 28/4/22 - -
A14-E SHUTTING WAITING FOR
23/5/22 3)LIFT STOP 2)LVL SENSOR ERROR
REPLACEMENT PART

RUNNING ON ARRIVAL
RESET AND LIFT RUN BACK TO
NORMAL
28/4/22 - -
REPLACE NEW PART. LIFT RUN
19/6/22 LIFT STOP AT LVL 3 LEVELING SENSOR ERROR
A26-O 4 BACK TO NORMAL ON 15/7/22
28/6/22 LIFT STOP AT LVL 1 LEVELING SENSOR ERROR
READJUST DOOR LIF RUN BACK
12/10/22 LIFT STOP AT LVL 5 LANDING DOOR BACK CONTACT
TO NORMAL
RESET & LIFT RUN BACK TO
A26-E 1 12/7/2022 LIFT STOP LVL 10 DIRT ON LANDING DOOR SILL
NORMAL