Siemens Simatic S7 400 PLC 2009
Siemens Simatic S7 400 PLC 2009
SIMATIC S7-400
Brochures
For brochures serving as selection
guides for SIMATIC products refer to:
http://www.siemens.com/simatic/
printmaterial
Siemens ST 70 · 2009
© Siemens AG 2008
SIMATIC S7-400
Introduction
S7-400/S7-400H/S7-400F/FH
■ Overview
S7-400H
5
• The power PLC for the mid to high-end performance ranges.
• The solution for even the most demanding tasks.
• Fault-tolerant automation system with redundant configuration
• With a comprehensive range of modules and performance-
• For applications with high failure safety requirements
graded CPUs for optimal adaptation to the automation task.
Processes with high restart costs, expensive downtimes, little
• Flexible in use through simple implementation of distributed supervision, and few maintenance options
structures; user-friendly connection methods.
• Redundant central functions
• Optimal communication and networking options.
• Increases availability of I/O: Switched-I/O configuration
• User-friendly handling and uncomplicated design without a
• Also possible to use standard-availability I/Os: Single-sided
fan.
configuration
• Can be expanded without problems when the tasks increase.
• Hot standby: Automatic reaction-free switching to the standby
• Multicomputing: unit in the event of a fault
Simultaneous operation of several CPUs in one S7-400 central
• Configuration with 2 separate or one divided central controller
rack.
The overall performance power of an S7-400 is spread by • Connection of switched I/O via redundant PROFIBUS DP
means of multicomputing. For example, complex tasks can be
broken down into technologies such open-loop control,
computing or communication, and assigned to different
CPUs. Each CPU can be assigned its own local I/O.
• Modularity:
The powerful backplane bus of the S7-400 and the communi-
cation interfaces that can be connected direct to the CPU
enable high-performance operation of many communication
lines. This makes it possible, for example, to have one
communication line for HMI and programming tasks, one for
high-performance and equidistant motion control compo-
nents, and one "normal" I/O fieldbus. Additionally required
connections to MES/ERP systems or the Internet can also be
implemented.
• Engineering and diagnostics:
The S7-400 is configured and programmed extremely
efficiently together with the SIMATIC Engineering Tools, partic-
ularly in the case of extensive automation solutions with a high
engineering component. There are high-level languages such
as SCL available for this purpose and graphical engineering
tools for sequential controls, state diagrams, and technology-
oriented diagrams.
SIMATIC S7-400
Introduction
S7-400/S7-400H/S7-400F/FH
5
Group 1
Mechanical tolerance
• Vibration, tested per/with IEC 68, Part 2-6/10 to 58 Hz;
constant amplitude 0.075 mm;
58 to 150 Hz;
• Failsafe automation system for plant with high safety require-
ments constant acceleration 1 g;
• Complies with safety requirements up to SIL 3 to IEC 61508, Duration of vibrations:
AK6 to DIN V 19250 and Cat. 4 to EN 954-1 10 frequency cycles per axis in
the direction of each of the three
• If required, also fault tolerant through redundant configuration mutually normal axes
• Without additional wiring of the failsafe I/O: • Impact, tested per/with IEC 68, Part 2-27/semi-sinusoidal:
Failsafe communication via PROFIBUS DP with PROFISafe
profile. impact 15 g (peak value),
duration 11 ms
• Based on S7-400H and ET 200M, includes failsafe modules
• Standard modules for non-safety-related applications can
also be used in the automation system For brochures serving as selection guides for SIMATIC products
• Isolating module for common use of failsafe and standard refer to:
modules in safety operation on an ET 200M http://www.siemens.com/simatic/printmaterial
SIMATIC S7-400
Central processing units
CPU 412
■ Overview
• The low-cost starter solution for the medium performance
range
• Can be used in small and medium-sized systems with require-
ments of the medium performance range
■ Technical specifications
6ES7 412-1XJ05- 6ES7 412-2XJ05- 6ES7 412-1XJ05- 6ES7 412-2XJ05-
0AB0 0AB0 0AB0 0AB0
Product status Backup
Hardware product status 1 • present Yes Yes
Firmware version V5.0 V5.0 • with battery Yes Yes
associated programming STEP7 V5.3 SP2 or STEP7 V5.3 SP2 or • without battery No No
package higher with HW- higher with HW-
update update CPU/blocks
SIMATIC S7-400
Central processing units
CPU 412
SIMATIC S7-400
Central processing units
CPU 412
• buffered and synchroni- Yes Yes • Size of GD packets, max. 54 byte 54 byte
zable S7 basic communication
• Resolution 1 ms 1 ms • supported Yes Yes
Operating hours counter • Useful data per job, max. 76 byte 76 byte
• Number 8 8 S7 communication
Clock synchronization • supported Yes Yes
• supports Yes Yes • Useful data per job, max. 64 Kibyte 64 Kibyte
• to MPI, Master Yes Yes S5-compatible communi-
• to MPI, Slave Yes Yes cation
• to DP, Master Yes Yes • supported Yes; Via FC Yes; (via CP max.
AG_SEND and 10 and
• to DP, Slave Yes Yes AG_RECV, max. FC AG_SEND and
via 10 CP 443-1 or FC AG_RECV)
• in AS, Master Yes Yes
443-5
• in AS, Slave Yes Yes
• Useful data per job, max. 8 Kibyte 8 Kibyte
• on Ethernet via NTP No; Via CP No; Via CP
Standard communication
S7 message functions (FMS)
Number of login stations for 31; Max. 31 with 31; Max. 31 with • supported Yes; Via CP and Yes; Via CP and
message functions, max. alarm_S and alarm_S and loadable FB loadable FB
alarm_D (OP’s); alarm_D (OP’s);
Web server
max. 8 with alarm_8 max. 8 with alarm_8
and alarm_P (e.g. • Web server No; Via CP No; Via CP
WinCC)
• ISO-on-TCP (RFC1006) Via CP 443-1 Adv. Via CP 443-1 Adv.
Symbol-related messages Yes Yes and loadable FB and loadable FB
Number of messages - Number of connections, 30
max.
• overall, max. 512 512 - Data length, max. 1 452 byte 1452
Block related messages Yes Yes Number of connections
Alarm 8-blocks Yes Yes
• overall 32 32
Instrumentation & control Yes Yes
messages
SIMATIC S7-400
Central processing units
CPU 412
5
- PG/OP communication Yes Yes
- Routing Yes
- Routing Yes Yes
- S7 basic communication Yes
- Global data communi- Yes Yes
cation - S7 communication Yes
- S7 basic communication Yes Yes - equidistance support Yes
- S7 communication Yes Yes - Activation/deactivation of Yes
DP slaves
• Transmission speeds, 12 MBit/s 12 MBit/s - direct data exchange Yes
max. (cross traffic)
DP master • Transmission speeds, 12 MBit/s
• Number of connections, 16 16 max.
max. • Number of DP slaves, max. 64
• Services • Address area
- PG/OP communication Yes Yes - Inputs, max. 4 Kibyte
- Routing Yes Yes - Outputs, max. 4 Kibyte
- S7 basic communication Yes Yes
• Useful data per DP slave
- S7 communication Yes Yes
- Inputs, max. 244 byte
- equidistance support Yes Yes
- Outputs, max. 244 byte
- Activation/deactivation of Yes Yes
DP slaves DP slave
- direct data exchange Yes Yes • Number of connections 16
(cross traffic)
• Services
• Transmission speeds, 12 MBit/s 12 MBit/s
max. - Routing Yes
- Programming Yes
• Number of DP slaves, max. 32; Max. 544 slots 32
• GSD file http://support.
• Address area automation.
- Inputs, max. 2 Kibyte 2 Kibyte siemens.com/WW/
- Outputs, max. 2 Kibyte 2 Kibyte view/en/113652
• Useful data per DP slave • Transmission speeds, 12 MBit/s
- Inputs, max. 244 byte 244 byte max.
- Outputs, max. 244 byte 244 byte • Transfer memory
DP slave - Inputs 244 byte
- Outputs 244 byte
• Number of connections 16 16
• Address area, max. 32
• Services
- PG/OP communication Yes Yes • Useful data per address 32 byte
area, max.
- Routing Yes Yes
• Useful data per address 32 byte
• Transmission speeds, 12 MBit/s 12 MBit/s area, of which consistent,
max. max.
• Transfer memory Isochronous mode
- Inputs 244 byte 244 byte
- Outputs 244 byte 244 byte Useful data per isoch- 244 byte 244 byte
ronous slave, max.
• Address area, max. 32; Virtual slots 32
equidistance Yes Yes
• Useful data per address 32 byte 32 byte
area, max. shortest clock pulse 1.5 ms; 1.5 ms;
0.5 ms without use 0.5 ms without use
• Useful data per address 32 byte 32 byte of SFC 126, 127 of SFC 126, 127
area, of which consistent,
max.
SIMATIC S7-400
Central processing units
CPU 412
SIMATIC S7-400
Central processing units
CPU 412
English 6ES7 498-8AA05-8BA0 For SIMATIC OP, for connection to 6GK1 500-0EA02
PPI, MPI, PROFIBUS
French 6ES7 498-8AA05-8CA0
PROFIBUS FastConnect
Spanish 6ES7 498-8AA05-8DA0 bus cable
Italian 6ES7 498-8AA05-8EA0 Standard type with special design 6XV1 830-0EH10
for quick mounting, 2-core,
S7-400 instructions list
shielded, sold by the meter, max.
German 6ES7 498-8AA05-8AN0 delivery unit 1000 m, minimum
order quantity 20 m
English 6ES7 498-8AA05-8BN0
French 6ES7 498-8AA05-8CN0
Spanish 6ES7 498-8AA05-8DN0
Italian 6ES7 498-8AA05-8EN0
B3: Subject to export regulations: AL: N and ECCN: 5D992B1
SIMATIC S7-400
Central processing units
CPU 414
■ Overview
• CPUs for high demands in the mid-level performance range
• Applicable for plants with additional demands on
programming scope and processing speed
• Integrated PROFINET functions in CPU 414-3 PN/DP
5
■ Technical specifications
6ES7 414-2XK05-0AB0 6ES7 414-3XM05-0AB0 6ES7 414-3EM05-0AB0
Product status
Hardware product status 1
Firmware version V5.0 V5.0 V5.0
associated programming STEP7 V5.3 SP2 or higher with HW- STEP7 V5.3 SP2 or higher with HW- STEP7 V5.4 SP1 or higher
package update update
Feeding of external buffer 5 to 15 VDC 5 to 15 VDC 5 to 15 VDC
voltage to CPU
Current consumption
from backplane bus DC 5 V, 1.1 A 1.3 A 1.4 A
max.
from interface DC 5 V, max. 90 mA; At each DP interface 90 mA; At each DP interface 90 mA; At each DP interface
Current consumption/
power loss
Power loss, typ. 4W 4.5 W 5.5 W
Backup battery
• Buffer current, typ. 125 μA; Valid up to 40°C 125 μA; Valid up to 40°C 125 μA; Valid up to 40°C
• Buffer current, max. 550 μA 550 μA 550 μA
Memory
Type of storage
RAM
• integrated (for program) 0.5 MByte 1.4 MByte 1.4 MByte
• expandable No No No
Load memory
• expandable FEPROM Yes Yes Yes
Backup
• present Yes Yes Yes
• with battery Yes Yes Yes; All data
• without battery No No No
CPU/blocks
DB
• Number, max. 6 000; Number range: 1 to 16,000 6 000; Number range: 1 to 16,000 6 000; Number range: 1 to 16,000
• Size, max. 64 Kibyte 64 Kibyte 64 Kibyte
SIMATIC S7-400
Central processing units
CPU 414
SIMATIC S7-400
Central processing units
CPU 414
SIMATIC S7-400
Central processing units
CPU 414
SIMATIC S7-400
Central processing units
CPU 414
SIMATIC S7-400
Central processing units
CPU 414
SIMATIC S7-400
Central processing units
CPU 414
SIMATIC S7-400
Central processing units
CPU 414
SIMATIC S7-400
Central processing units
CPU 414
SIMATIC S7-400
Central processing units
CPU 414
5
Isochronous mode
Useful data per isochronoous 244 byte 244 byte 244 byte
slave, max.
equidistance Yes Yes Yes
shortest clock pulse 1 ms; 0.5 ms without use of SFC 126, 1 ms; 0.5 ms without use of SFC 126, 1 ms; Without use of SFC 126 and
127 127 127 up to 0.5 ms
CiR configuration in RUN
CiR synchronization time, 100 ms 100 ms 100 ms
basic load
CiR synchronization time, 80 μs 80 μs 80 μs
time per I/O slave
CPU/programming
Configuration software
• STEP 7 Yes Yes Yes
Programming language
• STEP 7 Yes
• LAD Yes Yes Yes
• FUP Yes Yes Yes
• AWL Yes Yes Yes
• SCL Yes Yes Yes
• CFC Yes Yes Yes
• GRAPH Yes Yes Yes
• HiGraph Yes Yes Yes
Nesting levels 7 7 7
User program protection/ Yes Yes Yes
password protection
Dimensions
Required slots 1 2 2
Dimensions
Dimensions
• Width 25 mm 50 mm 50 mm
• Height 290 mm 290 mm 290 mm
• Depth 219 mm 219 mm 219 mm
Weights
• Weight, approx. 720 g 880 g 900 g
SIMATIC S7-400
Central processing units
CPU 414
SIMATIC S7-400
Central processing units
CPU 414
5
FastConnect system Industrial Ethernet Switches with
Max. transfer rate 12 Mbit/s integral SNMP access, web
diagnostics, copper cable
Without PG interface 6ES7 972-0BA51-0XA0 diagnostics and PROFINET
diagnostics for configuring line,
With PG interface 6ES7 972-0BB51-0XA0
star and ring topologies;
RS 485 bus connector with four 10/100 Mbit/s RJ45 ports and
axial cable outlet two FO ports
For SIMATIC OP, for connection to 6GK1 500-0EA02 IE FC RJ45 plugs
PPI, MPI, PROFIBUS
RJ45 plug connector for Industrial
PROFIBUS FastConnect bus Ethernet with a rugged metal
cable enclosure and integrated
insulation displacement contacts
Standard type with special design 6XV1 830-0EH10 for connecting Industrial Ethernet
for quick mounting, 2-core, FC installation cables
shielded, sold by the meter,
max. delivery unit 1000 m, IE FC RJ45 plug 180
minimum order quantity 20 m
180° cable outlet
RS 485 repeater for PROFIBUS 6ES7 972-0AA01-0XA0
1 unit 6GK1 901-1BB10-2AA0
Data transfer rate up to 12 Mbit/s;
10 units 6GK1 901-1BB10-2AB0
24 V DC; IP20 housing
50 units 6GK1 901-1BB10-2AE0
PROFIBUS/PROFINET see Catalogs IK PI, CA 01
bus components
For establishing
MPI/PROFIBUS/PROFINET
communication
SIMATIC S7-400
Central processing units
CPU 416
■ Overview
• High-performance CPUs in the high-end performance range
• Applicable for plants with high requirements in the high-end
performance range
• Integrated PROFINET functions in CPU 416-3 PN/DP
5
■ Technical specifications
6ES7 416-2XN05-0AB0 6ES7 416-3XR05-0AB0 6ES7 416-3ER05-0AB0
Product status
Firmware version V5.0 V5.0 V5.0
associated programming STEP7 V5.3 SP2 or higher with STEP7 V5.3 SP2 or higher with STEP7 V5.4 SP1 or higher
package HW-update HW-update
Feeding of external buffer 5 to 15 V DC 5 to 15 V DC 5 to 15 V DC
voltage to CPU
Current consumption
from backplane bus DC 5 V, 1.1 A 1.3 A 1.4 A
max.
from interface DC 5 V, max. 90 mA; At each DP interface 90 mA; At each DP interface 90 mA; At each DP interface
Current consumption/
power loss
Power loss, typ. 4W 4.5 W 5.5 W
Backup battery
• Buffer current, typ. 125 μA; Valid up to 40°C 125 μA; Valid up to 40°C 125 μA; Valid up to 40°C
• Buffer current, max. 550 μA 550 μA 550 μA
Memory
Type of storage
RAM
• integrated (for program) 2.8 MByte 5.6 MByte 5.6 MByte
• integrated (for data) 2.8 MByte 5.6 MByte 5.6 MByte
• expandable No No No
Load memory
• expandable FEPROM Yes Yes Yes; with Memory Card (FLASH)
• expandable FEPROM, max. 64 MByte 64 MByte 64 MByte
• integrated RAM, max. 1 MByte 1 MByte 1 MByte
• expandable RAM Yes Yes Yes; With Memory Card (RAM)
• expandable RAM, max. 64 MByte 64 MByte 64 MByte
Backup
• present Yes Yes Yes
• with battery Yes Yes Yes
• without battery No No No
CPU/blocks
DB
• Number, max. 10 000; Number range: 1 to 16,000 10 000; Number range: 1 to 16,000 10 000; Number range: 1 to 16,000
• Size, max. 64 Kibyte 64 Kibyte 64 Kibyte
SIMATIC S7-400
Central processing units
CPU 416
SIMATIC S7-400
Central processing units
CPU 416
SIMATIC S7-400
Central processing units
CPU 416
SIMATIC S7-400
Central processing units
CPU 416
SIMATIC S7-400
Central processing units
CPU 416
SIMATIC S7-400
Central processing units
CPU 416
5 MPI
• Number of connections 44 44 44
• Services
- PG/OP communication Yes Yes Yes
- Routing Yes Yes Yes
- Global data communication Yes Yes Yes
- S7 basic communication Yes Yes Yes
- S7 communication Yes Yes Yes
• Transmission speeds, max. 12 MBit/s 12 MBit/s 12 MBit/s
DP master
• Number of connections, max. 32 32 32; if a diagnostic repeater is used
on the line, the number of connection
resources on the line is reduced by 1
• Services
- PG/OP communication Yes Yes Yes
- Routing Yes Yes Yes
- Global data communication No No No
- S7 basic communication Yes Yes Yes
- S7 communication Yes Yes Yes
- equidistance support Yes Yes Yes
- Activation/deactivation of Yes Yes Yes
DP slaves
- direct data exchange Yes Yes Yes
(cross traffic)
• Transmission speeds, max. 12 MBit/s 12 MBit/s 12 MBit/s
• Number of DP slaves, max. 32 32 32
• Address area
- Inputs, max. 2 Kibyte 2 Kibyte 2 Kibyte
- Outputs, max. 2 Kibyte 2 Kibyte 2 Kibyte
• Useful data per DP slave
- Inputs, max. 244 byte 244 byte 244 byte
- Outputs, max. 244 byte 244 byte 244 byte
DP slave
• Number of connections 32 32 32
• Services
- PG/OP communication Yes Yes Yes; with interface active
- Routing Yes Yes Yes; with interface active
• Transmission speeds, max. 12 MBit/s 12 MBit/s 12 MBit/s
• Transfer memory
- Inputs 244 byte 244 byte 244 byte
- Outputs 244 byte 244 byte 244 byte
SIMATIC S7-400
Central processing units
CPU 416
SIMATIC S7-400
Central processing units
CPU 416
5
- Useful data consistency, 255 byte; incl. net data accompa-
max. niers
PROFINET CBA
• Acyclic transmission Yes
• cyclic transmission Yes
3rd interface
Type of interfaces Pluggable interface module (IF), Pluggable interface module (IF),
technical specifications as for 2nd technical specifications as for 2nd
interface interface
pluggable interface module IF 964-DP IF 964-DP
(Order No.: 6ES7 964-2AA04-0AB0) (Order No.: 6ES7 964-2AA04-0AB0)
Physics RS 485 / PROFIBUS
isolated Yes
power supply to interface 150 mA
(15 to 30 V DC), max.
Number of connection resources 32
Functionality
• MPI No
• DP master Yes
• DP slave Yes
DP master
• Number of connections, max. 32
• Services
- PG/OP communication Yes
- Routing Yes
- Global data communication No
- S7 basic communication Yes
- S7 communication Yes
- Equidistance support Yes
- SYNC/FREEZE Yes
- Activation/deactivation of Yes
DP slaves
- Direct data exchange Yes
• Transmission rate, max. 12 MBit/s
• Number of DP slaves, max. 125
• Address area
- Inputs, max. 8 Kibyte
- Outputs, max. 8 Kibyte
• Useful data per DP slave
- Useful data per DP slave, 244 byte
max.
- Inputs, max. 244 byte
- Outputs, max. 244 byte
SIMATIC S7-400
Central processing units
CPU 416
SIMATIC S7-400
Central processing units
CPU 416
SIMATIC S7-400
Central processing units
CPU 417
■ Overview
• The most powerful SIMATIC S7-400 CPU
• Can be used in the most sophisticated installations in the
upper performance range
• With two slots for IF modules
5
■ Technical specifications
6ES7 417-4XT05-0AB0 6ES7 417-4XT05-0AB0
Product status FB
Firmware version V5.0 • Number, max. 8 000; Number range: 0 to 7999
associated programming STEP7 V5.3 SP2 or higher with • Size, max. 64 Kibyte
package HW-update
FC
Feeding of external buffer 5 to 15 V DC
voltage to CPU • Number, max. 8 000; Number range: 0 to 7,999
SIMATIC S7-400
Central processing units
CPU 417
5 • Type
Data areas and their
SFB
Number of DP masters
• integrated 2
remanence
• via IM 467 4
remanent data area, total Total working and load memory
(with backup battery) • via CP 10; CP 443-5 Extended
Flag • Mixed mode IM + CP permitted No; IM 467 cannot be used with
CP 443-5 Ext.; IM 467 cannot be
• Number, max. 16 Kibyte
used with CP 443-1 EX40 in PN IO
• Remanence available Yes mode
• Number of clock memories 8; (in 1 memory byte) • via interface module 2
Address area • Number of pluggable S5 6
modules (via adapter capsule
I/O address area in central device), max.
• Inputs 16 Kibyte Number of IO controllers
• Outputs 16 Kibyte • via CP 4; Via CP 443-1 EX 41 in PN mode;
• of which, distributed max. 4 in central controller
- MPI/DPinterface, inputs 2 Kibyte Number of operable FMs and
- MPI/DP interface, outputs 2 Kibyte CPs (recommended)
- DP interface, inputs 8 Kibyte • FM Limited due to number of slots and
- DP interface, outputs 8 Kibyte number of connections
Process image • CP, point-to-point Limited due to number of slots and
number of connections
• Inputs, adjustable 16 Kibyte
• PROFIBUS and Ethernet CPs 14; Of which 10 CP or IM max. as
• Outputs, adjustable 16 Kibyte
DP master and PN controller
• Inputs, preset 1 024 byte
Time
• Outputs, preset 1 024 byte
Clock
• consistent data, max. 244 byte
• Hardware clock Yes
• Access to consistent data in Yes (real-time clock)
process image
• buffered and synchronizable Yes
Subprocess images
• Resolution 1 ms
• Number of subprocess 15
Operating hours counter
images, max.
• Number 8
Digital channels
Clock synchronization
• Inputs 131 072
• supports Yes
• Outputs 131 072
• to MPI, Master Yes
• Inputs, of which central 131 072
• to MPI, Slave Yes
• Outputs, of which central 131 072
• to DP, Master Yes
Analog channels
• to DP, Slave Yes
• Inputs 8 192
• in AS, Master Yes
• Outputs 8 192
• in AS, Slave Yes
• Inputs, of which central 8 192
• on Ethernet via NTP Via CP
• Outputs, of which central 8 192
• to IF 964 DP Yes
SIMATIC S7-400
Central processing units
CPU 417
5
Test commissioning functions - Routing Yes
Status/control - Global data communication Yes
- S7 basic communication Yes
• Status/control variable Yes - S7 communication Yes
Forcing • Transmission speeds, max. 12 MBit/s
• Forcing Yes DP master
Status block Yes • Number of connections, max. 32
Single step Yes • Services
Number of breakpoints 4 - PG/OP communication Yes
Diagnostic buffer - Routing Yes
- Global data communication No
• present Yes
- S7 basic communication Yes
• Number of entries, max. 3 200 - S7 communication Yes
• adjustable Yes - equidistance support Yes
- Activation/deactivation of Yes
• preset 120 DP slaves
Communication functions - direct data exchange Yes
(cross traffic)
PG/OP communication Yes
• Transmission speeds, max. 12 MBit/s
Routing Yes
• Number of DP slaves, max. 32
Global data communication
• Address area
• supported Yes
- Inputs, max. 2 Kibyte
• Size of GD packets, max. 54 byte - Outputs, max. 2 Kibyte
S7 basic communication • Useful data per DP slave
• supported Yes - Inputs, max. 244 byte
• Useful data per job, max. 76 byte - Outputs, max. 244 byte
DP slave
S7 communication
• supported Yes • Number of connections 32
SIMATIC S7-400
Central processing units
CPU 417
SIMATIC S7-400
Central processing units
CPU 417
5
4 MB 6ES7 952-1AM00-0AA0
SIMATIC Manual Collection B3 6ES7 998-8XC01-8YE2
8 MB 6ES7 952-1AP00-0AA0 update service for 1 year
16 MB 6ES7 952-1AS00-0AA0 Current "Manual Collection" DVD
and the three subsequent
64 MB 6ES7 952-1AY00-0AA0 updates
FEPROM memory card Brochure "SIMATIC S7-400
64 KB 6ES7 952-0KF00-0AA0 automation system - Design
and application"
256 KB 6ES7 952-0KH00-0AA0
German 6ES7 498-8AA00-8AB0
1 MB 6ES7 952-1KK00-0AA0
English 6ES7 498-8AA00-8BB0
2 MB 6ES7 952-1KL00-0AA0
RS 485 bus connector with
4 MB 6ES7 952-1KM00-0AA0 90° cable outlet
8 MB 6ES7 952-1KP00-0AA0 Max. transfer rate 12 Mbit/s
16 MB 6ES7 952-1KS00-0AA0 Without PG interface 6ES7 972-0BA12-0XA0
32 MB 6ES7 952-1KT00-0AA0 With PG interface 6ES7 972-0BB12-0XA0
64 MB 6ES7 952-1KY00-0AA0 RS 485 bus connector with
MPI cable 6ES7 901-0BF00-0AA0 angled cable outlet
Spanish 6ES7 498-8AA05-8DA0 Standard type with special design 6XV1 830-0EH10
for quick mounting, 2-core,
Italian 6ES7 498-8AA05-8EA0 shielded, sold by the meter,
max. delivery unit 1000 m,
S7-400 instructions list
minimum order quantity 20 m
German 6ES7 498-8AA05-8AN0
English 6ES7 498-8AA05-8BN0
French 6ES7 498-8AA05-8CN0
Spanish 6ES7 498-8AA05-8DN0
Italian 6ES7 498-8AA05-8EN0
B3: Subject to export regulations: AL: N and ECCN: 5D992B1
SIMATIC S7-400
Central processing units
CPU 412H, CPU 414H, CPU 417H
5
• CPU for the SIMATIC S7-400H and S7-400F/FH • CPU for SIMATIC S7-400H and S7-400F/FH
• Can be used in S7-400H fault-tolerant systems • Can be used in high availability S7-400H systems
• Can be used with F runtime license as F-enabled CPU in • Can be used with F-runtime license and F-compatible CPU in
S7-400F/FH safety-related systems failsafe S7-400F/FH systems
• With combined MPI/PROFIBUS DP master interface • With integrated PROFIBUS DP master interface
• With 2 connection slots for synchronization modules • With 2 slots for sync modules
SIMATIC S7-400
Central processing units
CPU 412H, CPU 414H, CPU 417H
■ Technical specifications
6ES7 412-3HJ14-0AB0 6ES7 414-4HM14-0AB0 6ES7 417-4HT14-0AB0
Product status
Hardware product status 1 1 1
Firmware version V4.5 V4.5 V4.5
associated programming STEP7 V5.3 SP2 or higher with STEP7 V5.3 SP2 or higher with STEP7 V5.3 SP2 or higher with
package HW update HW update HW update
Supply voltages
Rated value
• DC 24 V No; Power supply via system power No; Power supply via system power No; Power supply via system power
supply supply supply
Feeding of external buffer 5 to 15 V DC 5 to 15 V DC 5 to 15 V DC
voltage to CPU
Current consumption
from backplane bus DC 5 V,
max.
1.5 A 1.7 A 1.8 A
5
from interface DC 5 V, max. 90 mA; At each DP interface 90 mA; At each DP interface 90 mA; At each DP interface
Current consumption/
power loss
Power loss, typ. 5.5 W 6W 6.5 W
Backup battery
• Buffer current, typ. 190 μA; Valid up to 40°C 190 μA; Valid up to 40°C 970 μA; Valid up to 40°C
• Buffer current, max. 660 μA 660 μA 1 980 μA
Memory
Type of storage
RAM
• integrated (for program) 512 Kibyte 1.4 MByte 15 MByte
• expandable No No No
Load memory
• expandable FEPROM Yes Yes Yes
Backup
• present Yes Yes Yes
• with battery Yes; All data Yes; All data Yes; All data
• without battery No No No
CPU/blocks
DB
• Number, max. 4 095; Number range: 1 - 4095 4 095; Number range: 1 - 4095 8 191; Number range: 1 - 8191
• Size, max. 64 Kibyte 64 Kibyte 64 Kibyte
FB
• Number, max. 2 048; Number range: 0 - 2047 2 048; Number range: 0 - 2047 6 144; Number range: 0 - 6143
• Size, max. 64 Kibyte 64 Kibyte 64 Kibyte
FC
• Number, max. 2 048; Number range: 0 - 2047 2 048; Number range: 0 - 2047 6 144; Number range: 0 - 6143
• Size, max. 64 Kibyte 64 Kibyte 64 Kibyte
OB
• Size, max. 64 Kibyte 64 Kibyte 64 Kibyte
Nesting depth
• per priority class 24 24 24
• additional within an error OB 1 1 2
SIMATIC S7-400
Central processing units
CPU 412H, CPU 414H, CPU 417H
SIMATIC S7-400
Central processing units
CPU 412H, CPU 414H, CPU 417H
SIMATIC S7-400
Central processing units
CPU 412H, CPU 414H, CPU 417H
5 • to MPI, Slave
• to DP, Master
Yes
Yes
Yes
Yes
Yes
Yes
• to DP, Slave Yes Yes Yes
• in AS, Master Yes Yes Yes
• in AS, Slave Yes Yes Yes
S7 message functions
Number of login stations for 8 8 16
message functions, max.
Symbol-related messages No No No
Block related messages Yes Yes Yes
Alarm 8-blocks Yes Yes Yes
Instrumentation & control Yes Yes Yes
messages
Test commissioning functions
Status/control
• Status/control variable Yes Yes Yes
Forcing
• Forcing Yes Yes Yes
Status block Yes Yes Yes
Single step Yes Yes Yes
Number of breakpoints 4 4 4
Diagnostic buffer
• present Yes Yes Yes
• Number of entries, max. 3 200 3 200 3 200
• adjustable Yes Yes Yes
• preset 120 120 120
Communication functions
PG/OP communication Yes Yes Yes
Routing Yes Yes Yes
Global data communication
• supported No No No
S7 basic communication
• supported No No No
S7 communication
• supported Yes Yes Yes
• as server Yes Yes Yes
• as client Yes Yes Yes
• Useful data per job, max. 64 Kibyte 64 Kibyte 64 Kibyte
SIMATIC S7-400
Central processing units
CPU 412H, CPU 414H, CPU 417H
SIMATIC S7-400
Central processing units
CPU 412H, CPU 414H, CPU 417H
SIMATIC S7-400
Central processing units
CPU 412H, CPU 414H, CPU 417H
SIMATIC S7-400
Central processing units
CPU 412H, CPU 414H, CPU 417H
SIMATIC S7-400
Central processing units
CPU 412H, CPU 414H, CPU 417H
SIMATIC S7-400
Central processing units
CPU 416F
■ Overview
• For constructing a fail-safe automation system for plants with
increased safety requirements
• High-performance CPU in the top-end performance range
• Satisfies safety requirements up to SIL 3 acc. to IEC 61508
and Cat. 4 acc. to EN 954-1
• Standard and safety-related tasks can be performed with a
single CPU
• Multi-processor mode is possible
• Safety-related communication with distributed I/O devices
over PROFIBUS DP with the PROFIsafe profile
• Fail-safe I/O modules can be connected decentralized over
the integrated interfaces (DP and PN with CPU 416F-3 PN/DP)
and/or through communication modules (CP 443-5 Ext. and
CP 443-1 Adv.)
■ Technical specifications
6ES7 416-2FN05- 6ES7 416-3FR05- 6ES7 416-2FN05- 6ES7 416-3FR05-
0AB0 0AB0 0AB0 0AB0
Product status CPU/blocks
Firmware version V5.0 V5.0 DB
associated programming STEP7 V5.3 SP2 or STEP7 V5.4 SP1 or • Number, max. 10 000; Number 10 000; Number
package higher with HW- higher range: 1 to 16,000 range: 1 to 16,000
update
• Size, max. 64 Kibyte 64 Kibyte
Feeding of external buffer 5 to 15 V DC 5 to 15 V DC
voltage to CPU FB
SIMATIC S7-400
Central processing units
CPU 416F
• Number of clock memories 8; (in 1 memory 8; (in 1 memory • Mixed mode IM + CP No; IM 467 cannot No; IM 467 cannot
byte) byte) permitted be used with be used with
CP 443-5 Ext.; CP 443-5 Ext.;
Address area IM 467 cannot be IM 467 cannot be
used with used with
I/O address area CP 443-1 EX40 in CP 443-1 EX40 in
• Inputs 16 Kibyte 16 Kibyte PN IO mode PN IO mode
• Outputs 16 Kibyte 16 Kibyte • via interface module 0 1
• of which, distributed • Number of pluggable 6 6
- MPI/DPinterface, inputs 2 Kibyte 2 Kibyte S5 modules (via adapter
capsule in central device),
- MPI/DP interface, 2 Kibyte 2 Kibyte max.
outputs
- DP interface, inputs 8 Kibyte 8 Kibyte Number of IO controllers
- DP interface, outputs 8 Kibyte 8 Kibyte • integrated
Process image • via CP 4; 4;
Via CP 443-1 EX 41 Via CP 443-1 EX 41
• Inputs, adjustable 16 Kibyte 16 Kibyte in PN mode; max. 4 in PN mode; max. 4
• Outputs, adjustable 16 Kibyte 16 Kibyte in central controller in central controller
• Inputs, preset 512 byte 512 byte Number of operable FMs
and CPs (recommended)
• Outputs, preset 512 byte 512 byte
• consistent data, max. 244 byte 244 byte • FM Limited due to Limited due to
number of slots and number of slots and
• Access to consistent data Yes Yes number of connec- number of connec-
in process image tions tions
SIMATIC S7-400
Central processing units
CPU 416F
• CP, point-to-point Limited due to Limited due to • Number of entries, max. 3 200 3 200
number of slots and number of slots and • adjustable Yes Yes
number of connec- number of connec-
tions tions • preset 120 120
• PROFIBUS and Ethernet 14; Of which 10 CP 14; Of which 10 Communication functions
CPs or IM max. as DP CP/IM max. as DP PG/OP communication Yes Yes
master and PN master and PN
controller controller Routing Yes Yes
Time Global data communication
Clock • supported Yes Yes
5 • Hardware clock
(real-time clock)
Yes Yes • Size of GD packets, max.
S7 basic communication
54 byte 54 byte
SIMATIC S7-400
Central processing units
CPU 416F
SIMATIC S7-400
Central processing units
CPU 416F
5 • Number of connections,
max.
32 • Updating time 250 μs to 512 ms;
minimum value
dependent on
• Services preset communi-
- PG/OP communication Yes cation share for
- Routing Yes PROFINET I/O,
- S7 basic communication Yes of number of I/O
devices and
- S7 communication Yes
number of
- equidistance support Yes configured user
- Activation/deactivation of Yes data
DP slaves
• Address area
- direct data exchange Yes
(cross traffic) - Inputs, max. 8 Kibyte
- Outputs, max. 8 Kibyte
• Transmission speeds, 12 MBit/s
- Useful data consistency, 255 byte; incl. net
max.
max. data accompaniers
• Number of DP slaves, max. 125
PROFINET CBA
• Address area
• Acyclic transmission Yes
- Inputs, max. 8 Kibyte
- Outputs, max. 8 Kibyte • cyclic transmission Yes
SIMATIC S7-400
Central processing units
CPU 416F
SIMATIC S7-400
Central processing units
CPU 416F
SIMATIC S7-400
Central processing units
CPU 416F
5
system integral SNMP access, web
Max. transfer rate 12 Mbit/s diagnostics, copper cable
diagnostics and PROFINET
Without PG interface 6ES7 972-0BA51-0XA0 diagnostics for configuring line,
star and ring topologies;
With PG interface 6ES7 972-0BB51-0XA0
four 10/100 Mbit/s RJ45 ports and
RS 485 bus connector with two FO ports
axial cable outlet
IE FC RJ45 plugs
For SIMATIC OP, for connection to 6GK1 500-0EA02
RJ45 plug connector for Industrial
PPI, MPI, PROFIBUS
Ethernet with a rugged metal
PROFIBUS FastConnect enclosure and integrated
bus cable insulation displacement contacts
for connecting Industrial Ethernet
Standard type with special design 6XV1 830-0EH10 FC installation cables
for quick mounting, 2-core,
shielded, sold by the meter, IE FC RJ45 plug 180
max. delivery unit 1000 m,
180° cable outlet
minimum order quantity 20 m
1 unit 6GK1 901-1BB10-2AA0
RS 485 repeater for PROFIBUS 6ES7 972-0AA01-0XA0
10 units 6GK1 901-1BB10-2AB0
Data transfer rate up to 12 Mbit/s;
24 V DC; IP20 housing 50 units 6GK1 901-1BB10-2AE0
PROFIBUS/PROFINET see Catalogs IK PI, CA 01
bus components
For establishing
MPI/PROFIBUS/PROFINET
communication
SIMATIC S7-400
Central processing units
Sync module for coupling the CPU 41xH
5 6ES7 960-1Ax04-0XA0
•1m 6ES7 960-1AA04-5AA0
•2m 6ES7 960-1AA04-5BA0
• For coupling the two CPU 41xH in the S7-400H subunits.
• 10 m 6ES7 960-1AA04-5KA0
• Can be plugged direct into the CPU
For Sync module on request
■ Technical specifications
6ES7 960-1AB04-0XA0;
fiber-optic monomode
LC/LC duplex crossed 9/125 μ
6ES7 960-1AA04- 6ES7 960-1AB04- (max. 10 km)
0XA0 0XA0
Current consumption
from CPU, max. 210 mA 250 mA
Current consumption/
power loss
Power loss, typ. 1.1 mW 1.3 mW
Dimensions
Dimensions
• Width 25 mm 25 mm
• Height 53 mm 53 mm
• Depth 140 mm 140 mm
Weights
• Weight, approx. 65 g 65 g
B7: Subject to export regulations: AL: N and ECCN: EAR99H
SIMATIC S7-400
Central processing units
IF-964 DP PROFIBUS module
SIMATIC S7-400
SIPLUS central processing units
SIPLUS CPU 416, CPU 417
■ Overview SIPLUS CPU 416-3, CPU 416-3 PN/DP ■ Overview SIPLUS CPU 417-4
5
High-performance CPUs in the high-end performance range The most powerful SIMATIC S7-400 CPU
• Applicable for plants with high requirements in the high-end • Applicable for plants with maximum requirements in the high-
performance range end performance range
• Integrated PROFINET functions in CPU 416-3 PN/DP • With 2 plug-in slots for IF modules
For further technical documentation on SIPLUS, see: For further technical documentation on SIPLUS, see:
http://www.siemens.com/siplus-techdoku http://www.siemens.com/siplus-techdoku
SIMATIC S7-400
SIPLUS central processing units
SIPLUS CPU 414-4H, CPU 417-4H
5
CPU for SIMATIC S7-400H and S7-400F/FH CPU for SIMATIC S7-400H and S7-400F/FH
• For use in S7-400H fault-tolerant systems • For use in S7-400H fault-tolerant systems
• Can be used with F-Runtime license as fail-safe CPU in safety- • Can be used with F-Runtime license as fail-safe CPU in safety-
related S7-400F/FH systems related S7-400F/FH systems
• With integral PROFIBUS DP master interface • With integral PROFIBUS DP master interface
• With 2 plug-in slots for sync modules • With 2 plug-in slots for sync modules
For further technical documentation on SIPLUS, see: For further technical documentation on SIPLUS, see:
http://www.siemens.com/siplus-techdoku http://www.siemens.com/siplus-techdoku
■ Technical specifications
6AG1 414-4HJ04- 6AG1 417-4HL04- 6AG1 414-4HJ04- 6AG1 417-4HL04-
4AB0 4AB0 4AB0 4AB0
Supply voltages Memory
Rated value Type of storage
• DC 24 V Yes Yes RAM
Feeding of external buffer 5 to 15 V DC 5 to 15 V DC • integrated (for program) 700 Kibyte
voltage to CPU
• integrated (for data) 700 Kibyte
Current consumption
• expandable No No
from backplane bus DC 5 V, 2 A 1.7 A
max. Load memory
Current consumption/ • expandable FEPROM Yes; with Memory Yes; with Memory
power loss Card (FLASH) Card (FLASH)
Power loss, typ. 4.5 W 6W • expandable FEPROM, 64 MByte 64 MByte
max.
Backup battery
• integrated RAM, max. 256 Kibyte 256 Kibyte
• Buffer current, typ. 550 μA 600 μA
• expandable RAM Yes; With Memory Yes; With Memory
• Buffer current, max. 1 530 μA 1 810 μA Card (RAM) Card (RAM)
• expandable RAM, max. 16 MByte 16 MByte
SIMATIC S7-400
SIPLUS central processing units
SIPLUS CPU 414-4H, CPU 417-4H
• Time range
- lower limit 10 ms 10 ms
- upper limit 9 990 s 9 990 s
IEC timer
• present Yes Yes
• Type SFB SFB
SIMATIC S7-400
SIPLUS central processing units
SIPLUS CPU 414-4H, CPU 417-4H
SIMATIC S7-400
SIPLUS central processing units
SIPLUS CPU 414-4H, CPU 417-4H
5 • DP master
• DP slave
Yes; Default setting Yes
No No
User program
protection/password
protection
Yes Yes
SIMATIC S7-400
Digital modules
SM 421 digital input modules
■ Overview
• Digital inputs for the SIMATIC S7-400
• For connecting standard switches and two-wire proximity
switches (BERO)
5
■ Technical specifications
6ES7 421-7BH01- 6ES7 421-1BL01- 6ES7 421-1EL00- 6ES7 421-1FH20- 6ES7 421-7DH00-
0AB0 0AA0 0AA0 0AA0 0AB0
Supply voltages
Load voltage L+
• Rated value (DC) 24 V
• permissible range, 20.4 V
lower limit (DC)
• permissible range, 28.8 V
upper limit (DC)
Current consumption
from backplane bus DC 5 V, 130 mA 20 mA 200 mA 80 mA 150 mA
max.
from supply voltage L+, max. 120 mA
Current consumption/
power loss
Power loss, max. 5W 6W 16 W 12 W 8 W; 3.5 W (24 V DC);
6.5 W (48 V DC);
8.0 W (60 V DC)
Digital inputs
Number of digital inputs 16 32 32 16 16
Number of simultanneously
controllable inputs
- Number of simultaneously 16 32 32 16 16
controllable inputs,
up to 40 °C
- Number of simultaneously 16 32 32 16 16
controllable inputs,
up to 60 °C
Input voltage
• Rated value, DC 24 V 24 V
• Rated value, UC 120 V 230 V; 120/230 V UC 24 V; 24 to 60 V UC
• for signal "0" -30 to +5 V DC -30 to +5 V DC 0 to 20 V UC 0 to 40 V AC/ -6 to +6 V DC/
-40 to +40 V DC 0 to 5 V AC
• for signal "1" 11 to 30 V DC 13 to 30 V DC 79 to 132 V AC; 74 to 264 V AC; 15 to 72 V DC;
80 to 132 V DC 80 to 264 V DC, -15 to -72 V DC;
-80 to -264 V 15 to 60 V AC
• Frequency range 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz AC / DC
SIMATIC S7-400
Digital modules
SM 421 digital input modules
5 Cable length
20 ms
SIMATIC S7-400
Digital modules
SM 421 digital input modules
SIMATIC S7-400
Digital modules
SM 422 digital output modules
■ Overview
• Digital outputs for the SIMATIC S7-400
• For connecting solenoid valves, contactors, low-power
motors, lamps and motor starters
5
■ Technical specifications
6ES7 422-1FH00- 6ES7 422-1HH00- 6ES7 422-1BH11- 6ES7 422-1BL00- 6ES7 422-7BL00-
0AA0 0AA0 0AA0 0AA0 0AB0
Supply voltages
Load voltage L+
• Rated value (DC) 60 V 24 V 24 V 24 V
• permissible range, lower limit 1V 20.4 V 20.4 V 20.4 V
(DC)
• permissible range, upper limit 60 V 28.8 V 28.8 V 28.8 V
(DC)
Load voltage L1
• Rated value (AC) 230 V; 120/230 V AC 230 V
• permissible range, lower limit 79 V 2V 20.4 V
(AC)
• permissible range, upper limit 264 V 264 V 28.8 V
(AC)
Current consumption
from load voltage L+ 1.5 mA 30 mA 30 mA 120 mA
(without load), max.
from load voltage L1 6 mA
(without load), max.
from backplane bus DC 5 V, 400 mA 1A 160 mA 200 mA 200 mA
max.
Current consumption/
power loss
Power loss, max. 16 W 25 W 7W 4W 8W
Digital outputs
Number of digital outputs 16 16; Relay 16 32 32
Short-circuit protection of the Yes; Fuse 8 A, 250 V; Yes; clocked Yes; clocked Yes; clocked
output per group electronically electronically electronically
Limitation of inductive shutdown -30 V -27 V L+ (-45 V)
voltage to
Lamp load, max. 50 W 60 W 10 W 5W 5W
Output voltage
• for signal "1", min. L1 (-18.1 V) L+ (-0.5 V) L+ (-0.3 V) L+ (-0.8 V)
SIMATIC S7-400
Digital modules
SM 422 digital output modules
5
Aggregate current of the outputs
(per group)
• up to 60 °C, max. 2 A; 5 A with fan 5 mA; 10 A with fan 2 A; 2 adjacent 2 A; 8 adjacent 2A
subassembly; per subassembly outputs each outputs each
4 adjacent outputs
• cable length, shielded, max. 1 000 m 1 000 m 1 000 m 1 000 m 1 000 m
• Cable length unshielded, max. 600 m 600 m 600 m 600 m 600 m
Relay outputs
Number of operating cycles 100 000; 100,000
(AC 15 / DC 13);
3,000,000
mechanical
Switching capacity of the
contacts
• with inductive load, max. 5 A; 5 A (30 V DC);
5 A (230 V AC)
• with resistive load, max. 5 A; 5 A (30 V DC);
5 A (230 V AC);
1.2 A (60 V DC);
0.2 A (125 V DC)
Status information/alarms/
diagnostics
Alarms
• Diagnostic alarm Yes; Parameterizable
Diagnoses
• Diagnostics Yes;
internal/ external fault
Isolation
Isolation checked with 1500 V AC 1500 V AC 500 V DC 500 V DC 500 V DC
Isolation
Isolation, digital outputs
• between the channels, in 4 2 8 32 8
groups of
• between the channels and the Yes Yes Yes Yes Yes
backplane bus
Dimensions
Dimensions
• Width 25 mm 25 mm 25 mm 25 mm 25 mm
• Height 290 mm 290 mm 290 mm 290 mm 290 mm
• Depth 210 mm 210 mm 210 mm 210 mm 210 mm
Weights
• Weight, approx. 800 g 700 g 600 g 600 g 600 g
SIMATIC S7-400
Digital modules
SM 422 digital output modules
SIMATIC TOP connect see page 5/131; Current "Manual Collection" DVD
Information about which compo- and the three subsequent
nents can be used for the updates
respective module, see Manual "SIMATIC S7-400
DT&IAMall or Catalog KT 10.2 programmable controller"
Cover film for labeling strips 6ES7 492-2XX00-0AA0 incl. instruction list
Spare part German 6ES7 498-8AA05-8AA0
S7 SmartLabel V3.0 English 6ES7 498-8AA05-8BA0
Software for automatic labeling of French 6ES7 498-8AA05-8CA0
modules direct from the STEP 7
project Spanish 6ES7 498-8AA05-8DA0
Single license B8 2XV9 450-1SL03-0YX0 Italian 6ES7 498-8AA05-8EA0
Upgrade single license B8 2XV9 450-1SL03-0YX4
B3: Subject to export regulations: AL: N and ECCN: 5D992B1
B6: Subject to export regulations: AL: N and ECCN: EAR99
B7: Subject to export regulations: AL: N and ECCN: EAR99H
B8: Subject to export regulations: AL: N and ECCN: EAR99S
SIMATIC S7-400
SIPLUS digital modules
SIPLUS SM 421 digital input modules
SIPLUS SM 422 digital output modules
5
• Digital inputs for SIMATIC S7-400 • Digital outputs for SIMATIC S7-400
• For connection of switches and 2-wire proximity switches • For connecting solenoid valves, contactors, small-power
(BEROs) motors, lamps and motor starters
Digital input module SIPLUS SM 421 Digital input module SIPLUS SM 422
Order No. 6AG1 421-1BL01-2AA0 Order No. 6AG1 422-1BL00-2AA0
Order No. based on 6ES7 421-1BL01-0AA0 Order No. based on 6ES7 422-1BL00-0AA0
Ambient temperature range -25 ... +60 °C Ambient temperature range -25 ... +60 °C
Environmental conditions Suited for exceptional medial Environmental conditions Suited for exceptional medial
exposure (e. g. by chlorine sulfur exposure (e. g. by chlorine sulfur
atmosphere). atmosphere).
Technical data The technical data are identical Technical data The technical data are identical
with those of the based-on with those of the based-on
modules. modules.
For further technical documentation on SIPLUS, see: For further technical documentation on SIPLUS, see:
http://www.siemens.com/siplus-techdoku http://www.siemens.com/siplus-techdoku
SIMATIC S7-400
Analog modules
SM 431 analog input modules
■ Overview
• Analog inputs for the SIMATIC S7-400
• For connection of voltage and current sensors,
thermocouples, resistors and resistance thermometers
• Resolution from 13 to 16 bit
5
■ Technical specifications
6ES7 431-0HH00-0AB0 6ES7 431-1KF20-0AB0 6ES7 431-1KF00-0AB0 6ES7 431-1KF10-0AB0
Supply voltages
Load voltage L+
• Rated value (DC) 24 V; only required for 24 V; only required for not necessary 24 V; only required for
supplying 2-wire trans- supplying 2-wire trans- supplying 2-wire trans-
mitters mitters mitters
• reverse polarity protection Yes Yes Yes
Current consumption
from load voltage L+ 400 mA; for 16 connected, 200 mA; for 8 connected, 200 mA
(without load), max. fully controlled 2-wire trans- fully controlled 2-wire trans-
mitters mitters
from backplane bus DC 5 V, 100 mA 1 000 mA 350 mA 600 mA
max.
Current consumption/
power loss
Power loss, typ. 2W 4.9 W 1.8 W 3.5 W
Analog inputs
Number of analog inputs 16 8 8 8
Number of analog inputs for 16 8 8 8
voltage/current measurement
Number of analog inputs for 4 4 4
resistance measurement
cable length, shielded, max. 200 m 200 m 200 m 200 m; 50 m with thermo-
couples and input ranges
<= 80 mV
Input ranges (rated values),
voltages
• 1 to 5 V Yes Yes Yes Yes
• -1 V to +1 V Yes Yes Yes Yes
• -10 V to +10 V Yes Yes Yes Yes
• -2.5 V to +2.5 V Yes
• -250 mV to +250 mV Yes
• -5 V to +5 V Yes
• -500 mV to +500 mV Yes
• -80 mV to +80 mV Yes
SIMATIC S7-400
Analog modules
SM 431 analog input modules
SIMATIC S7-400
Analog modules
SM 431 analog input modules
resistance measurement
• Interference voltage 60 / 50 Hz none / 400 / 60 / 50 Hz 60 / 50 Hz 60 / 50 Hz
suppression for interference
frequency f1 in Hz
Encoder
Connection of signal encoders
• for current measurement as Yes Yes; with external trans- Yes
2-wire transducer mitter supply
• for current measurement as Yes Yes Yes Yes
4-wire transducer
• for resistance measurement Yes; Line resistances are Yes; Line resistances are Yes; Line resistances are
with 2-conductor connection also measured also measured also measured
• for resistance measurement Yes; Line resistances are Yes; Line resistances are Yes
with 3-conductor connection also measured also measured
• for resistance measurement Yes Yes Yes
with 4-conductor connection
Errors/accuracies
Operational limit in overall
temperature range
• Voltage, relative to input area +/- 0,65 %; +/- 0,7 %; +/- 1 %; +/- 0,38 %;
1.0% at 1 to 5 V; +/-0.7% at +/-1 V; +/-1.0% at +/-1 V; +/-0.38% at +/-80 mV;
0.65% at +/-1 V, +/-10 V +/-0.9% at +/-10 V, 1 to 5 V +/-0.6% at +/-10 V; +/-0.35% at +/-250 mV,
+/-0.7% at 1 to 5 V +/-500mV, +/-1 V, +/-2,5 V,
+/-5 V, 1 to 5 V, +/-10 V
• Current, relative to input area +/- 0.65 % +/- 0,8 %; +/- 1 %; +/- 0,35 %;
at +/-20 mA, 4 to 20 mA at +/-20 mA, 4 to 20 mA 0 to 20 mA, +/-20 mA,
4 to 20 mA
• Impedance, relative to input +/- 1 % +/- 1,25 %; 0 to 500 ohms +/- 0.5 %
area (4-conductor measurement,
in range of 600 ohms)
• Resistance-type thermometer, +/- 0.5 %
relative to input area
Basic error limit
(operational limit at 25 °C)
• Voltage, relative to input area +/- 0,25 %; +/- 0,6 %; +/- 0,7 %; +/- 0,15 %;
0.5% at 1 to 5 V; 0.6% at +/-1 V; 0.7% at +/-1 V; +/-0.15% (+/-250 mV,
0.25% at +/-1 V, +/-10 V 0.75% at +/-10 V, 1 to 5 V 0.4% at +/-10 V; +/-500 mV, +/-1 V, +/-2.5 V,
0.5% at 1 to 5 V +/-5 V, 1 to 5 V, +/- 10 V);
+/-0.17% (+/- 80 mV);
• Current, relative to input area +/- 0,25 %; +/- 0,7 %; +/- 0,7 %; +/- 0,15 %;
at +/-20 mA, 4 to 20 mA at +/- 20 mA, 4...20 mA at +/- 20 mA, 4...20 mA 0 to 20 mA, +/- 20 mA,
4 to 20 mA
SIMATIC S7-400
Analog modules
SM 431 analog input modules
5
(4-conductor
measurement, in range of
6000 ohms);
+/-0.3% at 0 to 300 ohms
(3-conductor
measurement),
0 to 600 ohms
(3-conductor
measurement),
0 to 5000 ohms
(3-conductor
measurement, in range of
6000 ohms)
• Resistance-type thermometer, +/- 0.3 %
relative to input area
Isolation
Isolation checked with 500 V DC between bus and 2120 V DC between bus 2120 V DC between bus 2120 V DC between bus
local ground and analog part; and analog part; and L+/M;
500 V DC between bus and 500 V DC between bus and 2120 V D between bus and
local ground; local ground; analog part;
707 V DC between analog 2120 V DC between analog 500 V DC between bus and
part and L+/M; part and local ground local ground;
2120 V DC between analog 707 V DC between analog
part and local ground; part and L+/M;
2120 V DC between L+/M 2120 V DC between analog
and local ground part and local ground;
2120 V DC between L+/M
and local ground
Isolation
Isolation, analog inputs
• Isolation, analog inputs No Yes; internal/external Yes; internal/external Yes; internal/external
• between the channels No No No No
Permissible potential
difference
between the inputs (UCM) 2 V DC / 2 Vpp AC 8 V AC 30 V AC 120 V AC
Dimensions
Required slots 1 1 1 1
Dimensions
Dimensions
• Width 25 mm 25 mm 25 mm 25 mm
• Height 290 mm 290 mm 290 mm 290 mm
• Depth 210 mm 210 mm 210 mm 210 mm
Weights
• Weight, approx. 500 g 500 g 500 g 500 g
SIMATIC S7-400
Analog modules
SM 431 analog input modules
5
Power loss, typ. 4.5 W 4.6 W 3.3 W
Analog inputs
Number of analog inputs 16 8 8
Number of analog inputs for 16 8
voltage/current measurement
Number of analog inputs for 8 8
resistance measurement
cable length, shielded, max. 200 m; 50 m with thermocouples and 200 m 200 m; 50 m with thermocouples and
input ranges <= 80 mV input ranges +/-80 mV
Input ranges (rated values),
voltages
• 1 to 5 V Yes Yes
• -1 V to +1 V Yes Yes
• -10 V to +10 V Yes Yes
• -100 mV to +100 mV Yes
• -2.5 V to +2.5 V Yes Yes
• -20 mV to +20 mV Yes
• -25 mV to +25 mV Yes
• -250 mV to +250 mV Yes Yes
• -5 V to +5 V Yes Yes
• -50 mV to +50 mV Yes Yes
• -500 mV to +500 mV Yes Yes
• -80 mV to +80 mV Yes Yes
Input ranges (rated values),
currents
• 0 to 20 mA Yes Yes
• -10 to +10 mA Yes Yes
• -20 to +20 mA Yes Yes
• -3.2 to +3.2 mA Yes
• 4 to 20 mA Yes Yes
• -5 to +5 mA Yes Yes
Input ranges (rated values),
thermoelements
• Type B Yes Yes
• Type E Yes Yes
• Type J Yes Yes
• Type K Yes Yes
• Type L Yes Yes
• Type N Yes Yes
• Type R Yes Yes
• Type S Yes Yes
• Type T Yes Yes
• Type U Yes Yes
SIMATIC S7-400
Analog modules
SM 431 analog input modules
SIMATIC S7-400
Analog modules
SM 431 analog input modules
5
Encoder
Connection of signal encoders
• for current measurement as Yes
2-wire transducer
• for current measurement as Yes Yes
4-wire transducer
• for resistance measurement Yes; Line resistances are also
with 2-conductor connection measured
• for resistance measurement Yes Yes
with 3-conductor connection
• for resistance measurement Yes Yes Yes
with 4-conductor connection
Errors/accuracies
Operational limit in overall
temperature range
• Voltage, relative to input area +/- 0,3 %; +/-0.3% at +/-250 mV, +/- 0.3 %
+/-500 mV, +/-1 V, +/-2.5 V, +/-5 V,
1 to 5 V, +/- 10 V;
+/-0.31% at +/-80 mV;
+/-0.32% at +/-50 mV;
+/-0.35% at +/-25 mV;
• Current, relative to input area +/- 0,3 %; at 0 to 20 mA, +/-5 mA, +/- 0.5 %
+/-10 mA, +/- 20 mA, 4 to 20 mA
• Impedance, relative to input +/- 0,3 %; +/-0.3% at 0 to 48 ohms
area (4-conductor measurement),
0 to 150 ohms (4-conductor
measurement),
0 to 300 ohms (4-conductor
measurement),
0 to 600 ohms (4-conductor
measurement),
0 to 5000 ohms (4-conductor
measurement, in range of
6000 ohms);
+/-0.4% at 0 to300 ohms (3-
conductor measurement),
0 to 600 ohms (3-conductor
measurement),
0 to 5000 ohms (3-conductor
measurement, in range of
6000 ohms);
• Resistance-type thermometer, +/- 0.4 % +/-1 °C
relative to input area
Basic error limit (operational limit
at 25 °C)
• Voltage, relative to input area +/- 0,15 %; +/-0.15% at +/-250 mV, +/- 0.1 %
+/-500 mV, +/-1 V, +/-2.5 V, +/-5 V,
1 to 5 V, +/-10 V;
+/-0.17% at +/-80 mV;
+/-0.19% at +/-50 mV;
+/-0.23% at +/-25 mV;
• Current, relative to input area +/- 0,15 %; at 0 to 20 mA, +/-5 mA, +/- 0.17 %
+/-10 mA, +/- 20 mA, 4 to 20 mA
SIMATIC S7-400
Analog modules
SM 431 analog input modules
5
measurement, in range of
6000 ohms)
• Resistance-type thermometer, +/- 0.3 % +/-0.2 °C
relative to input area
Status information/alarms/
diagnostics
Alarms
• Diagnostic alarm Yes; Parameterizable Yes; Parameterizable Yes; Parameterizable
• Limit value alarm Yes; Parameterizable Yes Yes
Diagnoses
• Diagnostics Yes; Parameterizable Yes Yes
Isolation
Isolation checked with 2120 V DC between bus and L+/M; 1500 V DC 1500 V DC
2120 V D between bus and analog
part;
500 V DC between bus and local
ground;
707 V DC between analog part and
L+/M;
2120 V DC between analog part and
local ground;
2120 V DC between L+/M and local
ground
Isolation
Isolation, analog inputs
• Isolation, analog inputs Yes; internal/external Yes; internal/external Yes; internal/external
• between the channels No Yes No
Permissible potential
difference
between the inputs (UCM) 120 V AC 120 V AC none
Dimensions
Required slots 1 1 1
Dimensions
Dimensions
• Width 25 mm 25 mm 25 mm
• Height 290 mm 290 mm 290 mm
• Depth 210 mm 210 mm 210 mm
Weights
• Weight, approx. 500 g 650 g 650 g
SIMATIC S7-400
Analog modules
SM 431 analog input modules
• with screw contacts, 1 item B7 6ES7 492-1AL00-0AA0 Electronic manuals on DVD, five
languages: S7-200/300/400, C7,
• with screw contacts, 84 items B6 6ES7 492-1AL00-1AB0 LOGO!, SIMATIC DP, PC, PG,
STEP 7, engineering software,
• with spring-loaded terminals, 6ES7 492-1BL00-0AA0 runtime software, PCS 7, SIMATIC
1 item HMI, SIMATIC NET
• with crimp contacts, 1 item B7 6ES7 492-1CL00-0AA0 SIMATIC Manual Collection B3 6ES7 998-8XC01-8YE2
• with crimp contacts, 84 items 6ES7 492-1CL00-1AB0 maintenance service for 1 year
1 unit; for 6ES7 431-7KF00-0AB0; 6ES7431-7KF00-6AA0 Current "Manual Collection" DVD
spare part, included in scope of and the three subsequent
delivery updates
SIMATIC TOP connect see page 5/131; Manual "SIMATIC S7-400
Information about which compo- programmable controller"
nents can be used for the incl. instruction list
respective module, see
DT&IAMall or Catalog KT 10.2 German 6ES7 498-8AA05-8AA0
Measuring range module for 6ES7 974-0AA00-0AA0 English 6ES7 498-8AA05-8BA0
analog inputs
French 6ES7 498-8AA05-8CA0
1 module for 2 inputs (spare part)
Spanish 6ES7 498-8AA05-8DA0
Cover film for labeling strips 6ES7 492-2XX00-0AA0
Italian 6ES7 498-8AA05-8EA0
Spare part
SIMATIC S7-400
Analog modules
SM 432 analog output modules
■ Overview
• Analog outputs for the SIMATIC S7-400
• For the connection of analog actuators
5
■ Technical specifications
6ES7 432-1HF00-0AB0 6ES7 432-1HF00-0AB0
Supply voltages Analog value creation
Load voltage L+ Integration and conversion
time/resolution per channel
• Rated value (DC) 24 V
• Resolution with overload area 13 Bit
Current consumption (bit including sign), max.
from backplane bus DC 5 V, 150 mA • Conversion time (per channel) 420 μs; 420 μs in the ranges 1 to 5 V
max. and 4 to 20 mA; 300 μs in all ranges
from supply voltage L+, max. 400 mA Settling time
Current consumption/ • for resistive load 0.1 ms
power loss
• for capacitive load 3.5 ms
Power loss, max. 9W
• for inductive load 0.5 ms
Analog outputs
Errors/accuracies
Number of analg outputs 8
Operational limit in overall
cable length, shielded, max. 200 m temperature range
Voltage output, Short-circuit Yes • Voltage, relative to output area +/- 0,5 %; +/-10 V, 0 to 10 V, 1 to 5 V
protection
• Current, relative to output area +/- 1 %; +/-20 mA, 4 to 20 mV
Voltage output, short-circuit 30 mA
current, max.. Basic error limit (operational limit
at 25 °C)
Current output, no-load voltage, 19 V
max. • Voltage, relative to output area +/- 0,5 %; +/- 10 V, 0 to 10 V, 1 to 5 V
Output ranges, voltage • Current, relative to output area +/- 0,5 %; +/-20 mA, 0 to 20 mA
• 0 to 10 V Yes Status information/alarms/
diagnostics
• 1 to 5 V Yes
Substitute values connectable No
• -10 to +10 V Yes
Isolation
Output ranges, current
Isolation checked with 2120 V DC between bus and L+/M;
• 0 to 20 mA Yes 2120 V D between bus and analog
• -20 to +20 mA Yes part;
500 V DC between bus and local
• 4 to 20 mA Yes ground;
Load impedance 707 V DC between analog part and
(in rated range of output) L+/M;
2120 V DC between analog part and
• with voltage outputs, min. 1 kΩ local ground;
2120 V DC between L+/M and local
• with voltage outputs, 1 μF
ground
capacitive load, max.
• with current outputs, max. 500 Ω; 600 ohms if common-mode-
voltage reduced to <1 V
SIMATIC S7-400
Analog modules
SM 432 analog output modules
SIMATIC S7-400
SIPLUS analog modules
SIPLUS SM 431 analog input module
SIPLUS SM 432 analog output module
5
• Analog inputs for SIMATIC S7-400 • Analog outputs for SIMATIC S7-400
• Connecting voltage sensors and current sensors, • For connection of analog actuators
thermo elements, resistors and resistance thermometers
• Resolution 13 to 16 bit
Analog input module SIPLUS SM 431 Analog output module SIPLUS SM 432
Order No. 6AG1 431-0HH00-4AB0 Order No. 6AG1 432-1HF00-4AB0
Order No. based on 6ES7 431-0HH00-0AB0 Order No. based on 6ES7 432-0HF00-0AB0
Ambient conditions Suited for exceptional medial Ambient conditions Suited for exceptional medial
exposure (e. g. by chlorine sulfur exposure (e. g. by chlorine sulfur
atmosphere). atmosphere).
Technical data The technical data are identical Technical data The technical data are identical with
with those of the based-on those of the based-on
modules. modules.
For further technical documentation on SIPLUS, see: For further technical documentation on SIPLUS, see:
http://www.siemens.com/siplus-techdoku http://www.siemens.com/siplus-techdoku
SIMATIC S7-400
Function modules
FM 450-1 counter module
■ Overview
• Two-channel intelligent counter module for simple counting
tasks
• For direct connection of incremental encoders
• Comparison function with 2 specifiable comparison values
• Integrated digital outputs for outputting the response when the
comparison values are reached
Note
SIMODRIVE Sensor/Motion Connect 500 feature incremental
encoders and preassembled connecting cables for counting
and positioning functions.
http://www.siemens.com/simatic-technology
5
■ Technical specifications
6ES7 450-1AP00-0AE0 6ES7 450-1AP00-0AE0
Supply voltages Input delay (for rated value of
input voltage)
Aux. voltage 1L+,
load voltage 2 L+ • Input frequency (with 0.1 ms 200 kHz
delay), max.
• Rated value (DC) 24 V
• for standard inputs
• permissible range, lower limit 20.4 V; dynamic 18.5 V
(DC) - programmable Yes
- at "0" to "1", max. 2.5 μs; >= 2.5 μs (200 kHz);
• permissible range, upper limit 28.8 V; dynamic 30.2 V <= 25 μs (20 kHz)
(DC)
Digital outputs
• non-periodic skip
- Duration 500 ms Number of digital outputs 6
- Recovery time 50 s Short-circuit protection of the Yes; clocked electronically
- Value 35 V output
Load voltage 1L+ Limitation of inductive shutdown 2L+ (-39 V)
voltage to
• Reverse polarity protection Yes
Output voltage
Load voltage 2L+
• for signal "0" (DC), max. 3V
• Reverse polarity protection Yes
• for signal "1", min. 2L+ (-1.5 V)
Current consumption
Output current
from load voltage 1L+ (without 40 mA
load), max. • for signal "1" rated value 0.5 A
from backplane bus DC 5 V, 450 mA • for signal "1" permissible range 5 mA
max. for 0 to 60 °C, min.
Current consumption/ • for signal "1" permissible range 0.6 A
power loss for 0 to 60 °C, max.
Power loss, typ. 9W Output delay with resistive load
Connection point • "0" to "1", max. 300 μs
required front connectors 1x 48-polig Encoder supply
Digital inputs 5 V encoder supply
Number of digital inputs 6 •5V Yes; 5.2 V +/-2 %
Functions 1 for gate start, 1 for gate stop, • Short-circuit protection Yes
1 for setting the counter • Output current, max. 300 mA
Input voltage 24 V encoder supply
• for signal "0" -28.8 to +5 V • 24 V Yes; 1L+ (-3 V)
• for signal "1" +11 to +28.8 V • Short-circuit protection Yes
Input current • Output current, max. 300 mA
• for signal "1", typ. 9 mA
SIMATIC S7-400
Function modules
FM 450-1 counter module
SIMATIC S7-400
Function modules
SIPLUS FM 450-1 counter module
Note:
We offer incremental sensors and preassembled connecting
cables for counting and positioning functions under SIMODRIVE
Sensor or Motion Connect 500.
http://www.siemens.com/simatic-technology
SIMATIC S7-400
Function modules
FM 451 positioning module
■ Overview
• Three-channel positioning module for rapid traverse/creep
speed drives
• 4 digital outputs per channel for motor control
• Incremental or synchro-serial position decoding
Note
SIMODRIVE Sensor/Motion Connect 500 feature position-
measuring systems and preassembled connecting cables for
counting and positioning functions.
http://www.siemens.com/simatic-technology
5
■ Technical specifications
6ES7 451-3AL00-0AE0 6ES7 451-3AL00-0AE0
Supply voltages Encoder supply
Rated value 5 V encoder supply
• DC 24 V Yes •5V Yes
Current consumption • Output current, max. 210 mA
Current consumption, max. 550 mA • Cable length, max. 35 m; at max. 210 mA
Connection point 24 V encoder supply
required front connectors 1x 48-pin • 24 V Yes
Digital inputs • Output current, max. 300 mA
Number of digital inputs 12; 4 per axis • Cable length, max. 100 m; at max. 300 mA
Functions Reference cams, reversing cams, Absolute encoder (SSI) encoder
flying actual value setting, start/stop supply
positioning
• Absolute encoder (SSI) Yes
Input voltage
• Output voltage 24 V DC
• Rated value, DC 24 V
• Output current, max. 300 mA
• for signal "0" -3 to +5 V
• Cable length, max. 300 m; at max.156 kbit/s
• for signal "1" 11 to 30 V
Encoder
Input current
Connectable encoders
• for signal "1", typ. 6 mA
• Incremental encoder Yes
• for 2-wire BERO (symmetrical)
- for signal "1", typ. 30 mA • Incremental encoder Yes
Digital outputs (asymmetrical)
Number of digital outputs 12; 4 per axis • Absolute encoder (SSI) Yes
Functions Rapid traverse, creep, run right, run Encoder signals, incremental
left encoder (symmetrical)
Short-circuit protection of the Yes • Trace mark signals A, notA, B, notB
output • Zero mark signal N, notN
Output voltage • Input signal 5 V difference signal (phys. RS 422)
• for signal "1", min. UP - 3 V • Input frequency, max. 1 MHz
Output current Encoder signals, incremental
• for signal "1" permissible range 600 mA; with UPmax encoder (asymmetrical)
for 0 to 55 °C, max. • Trace mark signals A. B
• for signal "0" residual current, 0.5 mA • Zero mark signal N
max.
• Input voltage 24 V
• Input frequency, max. 50 kHz; for 25 m cable length,
25 kHz for 100 m cable length
• cable length, shielded, max. 100 m
SIMATIC S7-400
Function modules
FM 451 positioning module
SIMATIC S7-400
Function modules
FM 452 cam controller
■ Overview
• Extremely high-speed electronic cam controller
• Low-cost alternative to mechanical cam controllers
• 32 cam tracks, 16 onboard digital outputs for direct output of
actions
• Incremental or synchro-serial position decoding
Note:
SIMODRIVE Sensor/Motion Connect 500 feature position-
measuring systems and preassembled connecting cables for
counting and positioning functions.
http://www.siemens.com/simatic-technology
5
■ Technical specifications
6ES7 452-1AH00-0AE0 6ES7 452-1AH00-0AE0
Supply voltages Encoder supply
Rated value 5 V encoder supply
• DC 24 V Yes •5V Yes
Current consumption • Output current, max. 300 mA
Current consumption, max. 500 mA • Cable length, max. 32 m
Connection point 24 V encoder supply
required front connectors 1x 48-pin • 24 V Yes
Digital inputs • Output current, max. 300 mA
Number of digital inputs 11 • Cable length, max. 100 m
Functions Reference point switch, flying actual Encoder
value setting/length measurement,
brake release, enable track output Connectable encoders
no. 3 to 10 • Incremental encoder Yes
Input voltage (symmetrical)
SIMATIC S7-400
Function modules
FM 452 cam controller
SIMATIC S7-400
Function modules
FM 453 positioning module
■ Overview
• Positioning module for servo and/or stepper motors in
machines with high clock pulse rates
• Can be used for point-to-point positioning tasks and for
complex traversing patterns
• Up to 3 independent motors can be controlled
Note:
SIMODRIVE Sensor/Motion Connect 500 feature position-
measuring systems and preassembled connecting cables for
counting and positioning functions.
http://www.siemens.com/simatic-technology
5
■ Technical specifications
6ES7 453-3AH00-0AE0 6ES7 453-3AH00-0AE0
Supply voltages Output voltage
Aux. voltage 1L+ to 4L+ • Rated value (DC) 24 V
• Rated value (DC) 24 V • for signal "1", min. UP - 0.3 V
• dynamic range 18.5 to 30.2 V Output current
• static area 20.4 to 28.8 V • for signal "1" rated value 0.5 A; at 40 °C; 0.1 A at 60 °C
Current consumption • for signal "1" permissible range 5 mA
for 0 to 40 °C, min.
from load voltage1L+, max. 1 A; with 24 V position encoder;
1 A for 5 V position encoder • for signal "1" permissible range 0.6 A
for 0 to 40 °C, max.
from load voltage 2L+ to 4L+, 2 A; per channel
max. • for signal "1" permissible range 5 mA
for 40 to 60 °C, min.
from backplane bus DC 5 V, 1.6 A; Rated current
max. • for signal "1" permissible range 0.12 A
for 40 to 60 °C, max.
Current consumption/
power loss • for signal "0" residual current, 2 mA
max.
Power loss, max. 8W
Switching frequency
Connection point
• with resistive load, max. 100 Hz
required front connectors 1x 48-pin
• with inductive load, max. 0.25 Hz
Digital inputs
Encoder supply
Number of digital inputs 6; for each channel/axis
5 V encoder supply
Functions configurable
•5V Yes
Input voltage
• Output current, max. 300 mA
• Rated value, DC 24 V
• Cable length, max. 35 m; at max. 210 mA;
• for signal "0" -3 to +5 V (max. 3 mA) 25 m at max. 300 mA
• for signal "1" 11 to 30 V (max. 7 mA) 24 V encoder supply
Input delay (for rated value of • 24 V Yes
input voltage)
• Cable length, max. 100 m; at max. 300 mA
• for standard inputs
- at "0" to "1", max. 15 μs; via input voltage range, Encoder
8 μs at DC 24 V Connectable encoders
- at "1" to "0", max. 45 μs; via input voltage range
• Incremental encoder Yes
Digital outputs (symmetrical)
Number of digital outputs 4; for each channel/axis • Absolute encoder (SSI) Yes
Functions configurable Encoder signals, incremental
Short-circuit protection of the Yes encoder (symmetrical)
output • Input signal 5 V difference signal (phys. RS 422)
• Input frequency, max. 1 MHz; for 10 m cable length;
0.5 MHz for 35 m cable length
SIMATIC S7-400
Function modules
FM 453 positioning module
• cable length, shielded, max. 250 m; at max. 156 kBit/s • Galvanic isolation, Yes; Optocoupler
digital outputs
Drive interface
Environmental requirements
Signal input I
Operating termperature
• Type Drive interface step, signal input
"READY 1" • min. 0 °C
5
Signal output I • min. -40 °C
• Type 5 V (phys. RS 422) • max. 70 °C
• Function Clock pulse, direction, enable, Relative humidity
current control
• Humidity class F No
• Differential output voltage, min. 2 V; RL = 100 Ohm
Degree of protection
• Differential output voltage for 1.1 V; Io = 30 mA
signal "0", max. IP 20 Yes
• Differential output voltage, 3.7 V; Io = -30 mA Dimensions
for signal "1", min. Dimensions
• Load impedance 55 Ω • Width 50 mm
• Pulse frequency 200 kHz; 500 kHz available soon • Height 290 mm
• Cable length, max. 35 m; 35 m with symm. transmission; • Depth 210 mm
10 m with asymm. transmission
Weights
Signal output II
• Weight, approx. 1 620 g
• Type Contact relay
• Function Drive disconnection for operation
• Load 1 A/50 V/30 VA DC
Signal output III
• Type Analog output
• Function Drive interface Servo:
Setpoint output for drive
• Output voltage -10 to +10 V
• Output current 3 to +3 mA
• Cable length, max. 30 m
SIMATIC S7-400
Function modules
FM 455 controller module
■ Overview
• 16-channel closed-loop control module for universal closed-
loop control tasks
• Suitable for temperature, pressure, and flow control systems
• User-friendly online self-optimization for temperature controls
• Preprogrammed controller structures
• 2 control algorithms
• 2 versions:
- FM 455 C as continuous-action controller
- FM 455 S as step controller or pulse controller
• With 16 analog outputs (FM 455 C) or 32 digital outputs
(FM 455 S) for actuators
5
■ Technical specifications
6ES7 455-0VS00- 6ES7 455-1VS00- 6ES7 455-0VS00- 6ES7 455-1VS00-
0AE0 0AE0 0AE0 0AE0
Supply voltages Limitation of inductive L+ (-1.5 V)
shutdown voltage to
Load voltage L+
Lamp load, max. 5W
• Rated value (DC) 24 V 24 V
Controlling a digital input Yes
• permissible range, lower 20.4 V 20.4 V
limit (DC) Output voltage
• permissible range, upper 28.8 V 28.8 V • for signal "1", min. L+ (-2.5 V)
limit (DC)
Output current
Current consumption
• for signal "1" rated value 0.1 A
from load voltage L+ 440 mA; 400 mA;
(without load), max. typ. 370 mA typ. 330 mA • for signal "1" permissible 5 mA
range for 0 to 60 °C, min.
Current consumption/
power loss • for signal "1" permissible 150 mA
range for 0 to 60 °C, max.
Power loss, max. 17.3 W 16.2 W
• for signal "0" residual 0.5 mA
Power loss, typ. 12 W 10.7 W current, max.
Connection point Parallel switching of
2 outputs
required front connectors 2x 48-pin 2x 48-pin
• for logic links Yes
Digital inputs
Switching frequency
Number of digital inputs 16 16
• with resistive load, max. 100 Hz
Input characteristic curve to Yes Yes
IEC 1131, Type 2 • with inductive load, max. 0.5 Hz
Input voltage • on lamp load, max. 100 Hz
• Rated value, DC 24 V 24 V Load impedance range
• for signal "0" -3 to +5 V -3 to +5 V • lower limit 240 Ω
• for signal "1" 13 to 30 V 13 to 30 V • upper limit 4 kΩ
Input current • cable length, shielded, 1 000 m
max.
• for signal "1", typ. 7 mA 7 mA
• Cable length unshielded, 600 m
Cable length max.
• cable length, shielded, 1 000 m 1 000 m Analog inputs
max.
Number of analog inputs 16; 16;
• Cable length unshielded, 600 m 600 m with thermo- with thermo-
max. couples or 2-wire couples or 2-wire
Digital outputs connection; connection;
8 with Pt 100 or 8 with Pt 100 or
Number of digital outputs 32 4-wire connection 4-wire connection
Short-circuit protection of Yes; Electronic
the output
SIMATIC S7-400
Function modules
FM 455 controller module
• internal temperature Yes; parametrizable Yes; parametrizable • for inductive load 0.5 ms 0.5 ms
compensation Encoder
• external temperature Yes; parametrizable Yes; parametrizable Connection of signal
compensation with Pt100 encoders
Analog outputs • for voltage measurement Yes Yes
Number of analg outputs 16 • for current measurement Yes Yes
cable length, shielded, max. 200 m; as 4-wire transducer
50m at 80 mV and Connectable encoders
thermocouples
• 2-wire BEROS Yes Yes
Voltage output, Short-circuit Yes - permissible quiescent 1.5 mA 1.5 mA
protection current (2-wire BEROS),
Voltage output, short-circuit 25 mA max.
current, max.. Errors/accuracies
Current output, no-load 18 V Linearity error (relative to +/- 0.05 % +/- 0.05 %
voltage, max. input area)
SIMATIC S7-400
Function modules
FM 455 controller module
SIMATIC S7-400
Function modules
FM 458-1 DP application module
■ Overview
SIMATIC FM 458-1 DP integrated into SIMATIC S7-400
• Designed for high-performance and freely-configurable
control tasks in the SIMATIC S7-400
• Can be adapted as required to individual requirements, e.g.:
open-loop control, closed-loop control, computing and motion
control. Therefore highly flexible for many different applica-
tions.
• Extensive library with approx. 300 function blocks:
These include simple functions such as AND, ADD and OR up
to complex GMC (General Motion Control) blocks such as
virtual master or gearbox functions.
• User-friendly graphic configuring with the SIMATIC
engineering tool CFC (Continuous Function Chart):
Optimum code generation by compiler, therefore SCL is not
required.
5 • PROFIBUS DP interface onboard
SIMATIC FM 458-1 DP is based on more than 15 years
experience with high-performance control systems, and
combines this know-how with the advantages of SIMATIC – the
global leader in automation systems for decades already. In
contrast to other function modules with static struc-
tures/functions, the FM 458-1 DP application module can be
flexibly configured according to individual requirements.
SIMATIC S7-400
Function modules
FM 458-1 DP basic module
■ Overview
• Basic module for handling computing, open-loop control and
closed-loop control tasks
• PROFIBUS DP interface for linking of distributed I/O and drive
engineering
• Modular configuration with expansion modules for I/O and
communication
5
■ Technical specifications
6DD1 607-0AA2 6DD1 607-0AA2
Supply voltages Digital inputs
Rated value Number of digital inputs 8; Connectors x2
• DC 5 V Yes Input voltage
• DC 24 V Yes • Rated value, DC 24 V
• Permissible range (ripple 4.8 V • for signal "0" -1 to +6 V
included), lower limit (DC)
• for signal "1" 13.5 to 33 V
• permissible range (ripple 5.25 V
included), upper limit (DC) Input current
SIMATIC S7-400
Function modules
FM 458-1 DP basic module
SIMATIC S7-400
Function modules
EXM 438-1 input/output expansion module
6DD1 607-0CA1
Output ranges, voltage
Supply voltages
• -10 to +10 V Yes
Rated value
Analog value creation
• DC 5 V Yes
Integration and conversion
• DC 24 V Yes; to be set up externally time/resolution per channel
Current consumption • Resolution with overload area 4 AO: 16 bits,
(bit including sign), max. 4 AO: 12 bits,
Current consumption, typ. 1.5 A 5 AI: 12 bits
Digital inputs • Conversion time (per channel) 4 AO (16 bits): 2 μs;
Number of digital inputs 16 4 AO (12 bits): 4 μs;
5 AI: 45 μs
Input voltage
Encoder supply
• Rated value, DC 24 V
Output voltage about 14 V (non-isolated)
• for signal "0" -1 to +6 V or input open
Output current, rated value 100 mA
• for signal "1" +13 to +33 V
Short-circuit protection Yes; electronic
Input current
Encoder
• for signal "0", max. (permissible 0 mA
quiescent current) Number of connectable 12;
encoders, max. 8 incremental encoders
• for signal "1", typ. 3 mA (synchronizable),
Input delay (for rated value of 4 absolute encoders
input voltage) Connectable encoders
• for standard inputs • Incremental encoder Yes
- at "0" to "1", max. 200 μs (symmetrical)
SIMATIC S7-400
Function modules
EXM 438-1 input/output expansion module
SIMATIC S7-400
Function modules
EXM 448
universal communication expansion module
SIMATIC S7-400
Function modules
EXM 448-2
universal communication expansion module
SIMATIC S7-400
Function modules
Accessories for FM 458-1 DP
5
• For connecting the FM 458-1 DP to an SBxx or SU12 interface This cable is used to connect the SIMATIC TDC SM500
module peripheral (I/O) module or the SIMATIC S7-400 EXM 438-1
• To use the digital inputs of the FM 458-1 DP with interrupt expansion module to a SU13 interface module.
capability
This cable is used to connect the SIMATIC TDC SM500 The interface module is used to connect 8 digital inputs or
peripheral module (I/O) or the SIMATIC S7-400 EXM 438-1 outputs.
expansion module to up to 5 interface modules SB10, SB60,
SB70, SB61 SB71 and/ or SU12.
SIMATIC S7-400
Function modules
Accessories for FM 458-1 DP
5
It is used to connect 8 digital inputs with conversion from The interface module is used to connect 10 signals;
24/48 V DC to 24 V DC. there is no electronic conversion.
The interface module is used to connect 8 digital outputs with This interface module can be used to connect 50 signals;
conversion of the 24 V DC voltage on the module side to a max. there is no electronic conversion.
of 24/48 V DC/AC on the plant side using transistors.
SIMATIC S7-400
Function modules
Accessories for FM 458-1 DP
Max. cable cross-section 1.5 mm² SB10 interface module 6DD1 681-0AE2
SIMATIC S7-400
Function modules
SIPLUS DCF 77 radio clock module
5
S7-200, S7-300 and S7-400 with
the official time of the DCF 77 time
signal transmitter of the
Physikalisch-Technische Bunde-
This module can be used to synchronize the real-time clock of sanstalt Braunschweig
the SIMATIC S7-200, S7-300 and S7-400 automation systems
with the official time of the DCF 77 time signal transmitter of the B7: Subject to export regulations: AL: N and ECCN: EAR99H
Physikalisch-Technische Bundesanstalt Braunschweig.
The time is received by means of a DCF receiver (antenna with
electronics) which is connected via two digital inputs on the
SIMATIC and SIPLUS together with a software driver included in
the scope of delivery (function block FB). The function blocks
are available on the Internet for downloading.
http://www.siemens.com/siplus – Support – Tools and
Downloads!
SIMATIC S7-400
Communication
CP 440
SIMATIC S7-400
Communication
CP 441-1, CP 441-2
■ Overview
• For powerful, high-speed serial communication via point-to-
point connections
• 2 versions:
- CP 441-1 with 1 variable interface for simple point-to-point
connection
- CP 441-2 with 2 variable interfaces for powerful point-to-
point connection
• Plug-in interface modules for different transmission interfaces:
RS 232C (V.24) , 20 mA (TTY) or RS 422/RS 485 (X.27)
• Implemented protocols: ASCII, 3964 (R), printer drivers;
CP 441-2 additionally has RK 512 and customized protocols
(retrofittable)
• Simple parameterization via a parameterization tool integrated
into STEP 7
5
■ Technical specifications
6ES7 441-1AA04- 6ES7 441-2AA04- 6ES7 441-1AA04- 6ES7 441-2AA04-
0AE0 0AE0 0AE0 0AE0
Supply voltages Point-to-point
Rated value supported printers HP-Deskjet, HP-Deskjet,
HP-Laserjet, HP-Laserjet,
• DC 5 V Yes Yes IBM-Proprinter, IBM-Proprinter,
• DC 24 V Yes Yes user-defined user-defined
Current consumption Transmission speed, max. 38.4 kBit/s 115.2 kBit/s;
distributed on both
from backplane bus DC 5 V, 600 mA; without 600 mA; without interfaces
max. interface module interface module
Integrated protocol driver
Current consumption/
power loss • 3964 (R) Yes Yes
Power loss, typ. 0.3 W 0.3 W • ASCII Yes Yes
Memory • Printer Yes Yes
Type of storage • customer-specific drivers No Yes
reloadable
Memory requirements per 1 to 5 KB for param- 1 to 5 KB for param-
interface in CompactFlash eters; eters; • RK512 No Yes
Card of S7-CPU 0 to 55 KB for 0 to 55 KB for
message texts message texts; Transmission speed,
0 to 64 KB for 20 mA (TTY)
loadable drivers • with 3964 (R) protocol, 19.2 kBit/s 19.2 kBit/s
interfaces max.
Number of interfaces 1; variable 2; variable • with ASCII protocol, max. 19.2 kBit/s 19.2 kBit/s
Physical interface, Yes Yes • with printer driver, max., 19.2 kBit/s 19.2 kBit/s
20mA (TTY) • with RK 512 protocol, max. 19.2 kBit/s
interface physics, Yes Yes Transmission speed,
RS 232C (V.24) RS 422/485
interface physics, Yes Yes • with 3964 (R) protocol, 38.4 kBit/s 115.2 kBit/s
RS 422/RS 485 (X.27) max.
20mA (TTY), cable length, 1 000 m 1 000 m • with ASCII protocol, max. 38.4 kBit/s 115.2 kBit/s
shielded, max.
• with printer driver, max. 38.4 kBit/s 115.2 kBit/s
RS 232, cable length, 10 m 10 m
shielded, max. • with RK 512 protocol, max. 115.2 kBit/s
RS 422/485, cable length, 1 200 m 1 200 m Transmission speed, RS232
shielded, max. • with 3964 (R) protocol, 38.4 kBit/s 115.2 kBit/s
interface module max.
• 20 mA (TTY), 100 mA; 100 mA 300 mA at 5 V; • with ASCII protocol, max. 38.4 kBit/s 115.2 kBit/s
power consumption from from 5 V; 45 mA at 24 V • with printer driver, max., 38.4 kBit/s 115.2 kBit/s
5 V/24 V, max. 45 mA from 24 V
• with RK 512 protocol, max. 115.2 kBit/s
• RS 422/485 (X.27), 250 mA; from 5 V 300 mA
power consumption from
5 V, max.
• RS 232C (V.24), 100 mA; from 5V 300 mA
power consumption from
5 V, max.
SIMATIC S7-400
Communication
CP 441-1, CP 441-2
SIMATIC S7-400
Communication
CP 443-5 Basic
■ Overview
• Connection of the S7-400 to PROFIBUS
• Communication services:
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
- PROFIBUS FMS
• Time synchronization
• Easy programming and configuration over PROFIBUS
• Cross-network programming device communication through
S7 routing
• Can be easily integrated into the SIMATIC S7-400 system
• Modules can be replaced without the need for a PG
• SIMATIC H system operation for redundant S7 communication
5
'30 '36 )06 3*23 66
*B,.B;;B
■ Technical specifications
Order No. 6GK7 443-5FX02-0XE0 Order No. 6GK7 443-5FX02-0XE0
Product type description CP 443-5 BASIC Product type description CP 443-5 BASIC
Transfer rate Design, dimensions and weight
Transmission rate at Interface 1 Module format S7-400 compact module,
single width
• Minimum 9.6 kbit/s
• Width 25 mm
• Maximum 12 Mbit/s
• Height 290 mm
Interfaces
• Depth 210 mm
Version of electrical connection of 9-pin Sub-D socket (RS 485)
the PROFIBUS interface Net weight 700 g
Supply voltage Performance data
Type of supply voltage DC FMS function
Supply voltage 5V Number of possible connections in 48
the case of FMS connection, max.
Relative symmetrical tolerance at 5%
5 V DC Data volume of the variables
Current consumption • for READ job, max. 237 byte
Current consumed from backplane 1.2 A • for WRITE job, max. 233 byte
bus at 5 V DC, typical
Number of variables
Effective power loss
• Configurable from server to 512
Effective power loss 6.5 W FMS partner
Permitted ambient conditions • Loadable from server to 2640
FMS partner
Ambient temperature
S7 communication
• during operation 0 … +60 °C
Number of possible connections for 48
• during storage -40 … +70 °C S7 communication, max. 1)
• during transport -40 … +70 °C
Maximum relative humidity at 95%
25 °C during operation
1) depending on the CPU type
SIMATIC S7-400
Communication
CP 443-5 Basic
SIMATIC S7-400
Communication
CP 443-5 Extended
■ Overview
• DP-V1 master connection of the S7-400 to PROFIBUS
• For setting up additional PROFIBUS DP lines
• Communication services:
- PROFIBUS DP
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
• Time synchronization
• Easy programming and configuration over PROFIBUS
• Cross-network programming device communication through
S7 routing
• Can be easily integrated into the SIMATIC S7-400 system
• Module replacement without PG
• SIMATIC H system operation for redundant S7 communication
5 or DP-Master communication
• Data record routing (PROFIBUS DP)
• Adding or modifying distributed I/O during operation
'30 '36 )06 3*23 66
*B,.B;;B
■ Technical specifications
Order No. 6GK7 443-5DX04-0XE0 Order No. 6GK7 443-5DX04-0XE0
Product type description CP 443-5 Extended Product type description CP 443-5 Extended
Transfer rate Design, dimensions and weight
Transmission rate at Interface 1 Module format S7-400 compact module,
• Minimum 9.6 kbit/s single width
• Maximum 12 Mbit/s • Width 25 mm
Interfaces • Height 290 mm
• Depth 210 mm
Version of electrical connection of 9-pin Sub-D socket (RS 485)
the PROFIBUS interface Net weight 700 g
Supply voltage Max. number of modules per CPU 14
Type of supply voltage DC Number of external DP lines per 10
central rack, max.
Supply voltage 5V
Performance data
Relative symmetrical tolerance 5%
at 5 V DC PROFIBUS DP
Current consumption Service as DP-Master DPV1 Yes
Current consumed from backplane 1.3 A Number of DP-Slaves 125
bus at 5 V DC, typical operable on DP-Master
Effective power loss Data volume
Effective power loss 6.5 W • of the address area of the inputs 4 Kibyte
as DP-Master overall
Permitted ambient conditions
• of the address area of the outputs 4 Kibyte
Ambient temperature as DP-Master overall
• during operation 0 … +60 °C • of the address area of the inputs 244 bytes
• during storage -40 … +70 °C per DP-Slave
• during transport -40 … +70 °C • of the address area of the outputs 244 bytes
per DP-Slave
Maximum relative humidity at 95%
25 °C during operation
SIMATIC S7-400
Communication
CP 443-5 Extended
SIMATIC S7-400
Communication
CP 443-1
■ Overview
• Connection of SIMATIC S7-400 to Industrial Ethernet
- 2 x RJ45 interface for 10/100 Mbit/s full/half duplex
connection with autosensing/autonegotiation and
autocrossover function
- Integrated real-time switch ERTEC with two ports
- Multi-protocol operation for ISO, TCP/IP, UDP and PROFINET
IO protocols
- Adjustable Keep Alive function
• Communication services:
- Open communication (ISO, TCP/IP and UDP)
- PROFINET IO Controller with real-time properties RT and IRT
- PG/OP communication: Across networks by means of S7
routing
- S7 communication
• Multicast for UDP
5
• Access protection by means of configurable access list
• Support for fail-safe programmable controllers in combination
with SIMATIC S7-400 CPU 416F-3 PN/DP
,62 7&3 31 053 ,7 ,35 3*23 66
• Module replacement without PG
8'3 • SIMATIC H system operation for redundant S7 communication
*B,.B;;B
SIMATIC S7-400
Communication
CP 443-1
■ Technical specifications
Order No. 6GK7 443-1EX20-0XE0 Order No. 6GK7 443-1EX20-0XE0
Product type description CP 443-1 Product type description CP 443-1
Transfer rate Performance data
Transmission rate at Interface 1 Open communication
• Minimum 10 Mbit/s Number of possible connections 64 2)
for open communication by means
• Maximum 100 Mbit/s of SEND/RECEIVE blocks, max. 3)
Interfaces Data volume as useful data for
Version of electrical connection to 2 x RJ45 (TP) open communication by means of
the Industrial Ethernet interface 1 SEND/RECEIVE blocks
Supply voltage • per ISO connection, max. 8 KB
Type of supply voltage DC • per ISO on TCP connection, max. 8 KB
Supply voltage 5V • per TCP connection, max. 8 KB
5
Relative symmetrical tolerance 5% • per UDP connection, max. 2 KB
at 5 V DC Number of possible connections 64
Current consumption for open communication by means
T blocks, max.
Current consumed from backplane 1.4 A
bus at 5 V DC, typical Data volume as useful data for
open communication by means
Effective power loss T-blocks
Effective power loss 8.6 W • per ISO on TCP connection, max. 1 452 bytes
Permitted ambient conditions S7 communication
Ambient temperature Number of possible connections
• during operation 0 … +60 °C for S7 communication
SIMATIC S7-400
Communication
CP 443-1
SIMATIC S7-400
Communication
CP 443-1 Advanced
■ Overview
• Connection of SIMATIC S7-400 to Industrial Ethernet
- Multi-protocol operation for ISO, TCP/IP, UDP and PROFINET
IO protocols
- Adjustable Keep Alive function
• Two separate interfaces (integrated network separation):
- Gigabit interface with an RJ45 connection with
10/100/1000 Mbit/s full/half duplex with auto-sensing
functionality
- PROFINET interface with four RJ45 connections with
10/100 Mbit/s full/half duplex with auto-sensing and auto-
crossover functionality via integrated 4-port switch
• Communication services via both interfaces
- Open communication (ISO, TCP/IP and UDP), Multicast with
UDP, incl. routing between two interfaces
- PG/OP communication:
Cross-network by means of S7 routing
- S7 communication (client, server, multiplexing) incl. routing
between both interfaces
5
- IT communication:
HTTP communication allows access to process data via own
,62 7&3 31 053 ,7 ,35 3*23 66
8'3 web sites;
e-mail client function, sending of e-mails with authentication
*B,.B;;B
SIMATIC S7-400
Communication
CP 443-1 Advanced
■ Technical specifications
Order No. 6GK7 443-1GX20-0XE0 Order No. 6GK7 443-1GX20-0XE0
Product type description CP 443-1 Advanced Product type description CP 443-1 Advanced
Transfer rate Data volume as useful data for
open communication by means of
Transmission rate at Interface 1 SEND/RECEIVE blocks
• Minimum 10 Mbit/s • per ISO connection, max. 8 KB
• Maximum 1000 Mbit/s • per ISO on TCP connection, max. 8 KB
Transmission rate at Interface 2 • per TCP connection, max. 8 KB
• Minimum 10 Mbit/s • per UDP connection, max. 2 KB
• Maximum 100 Mbit/s • for each e-mail connection, max. 2 KB
Interfaces Number of possible connections 64 2)
Electrical connection version for open communication by means
of T blocks, max.
• at Industrial Ethernet interface 1 1 x RJ45 (TP)
5
Data volume as useful data for
• at Industrial Ethernet interface 2 4 x RJ45 (TP) open comm. by means of T-blocks
Slot version of the swap medium C-PLUG • per ISO on TCP connection, max. 1 452 bytes
Supply voltage S7 communication
Type of supply voltage DC Number of possible connections
Supply voltage 5V for S7 communication
SIMATIC S7-400
Communication
CP 443-1 Advanced
5
Total number of interconnections in 600 • as useful data for remote inter- 2 000 bytes
the case of PROFINET CBA connections with output variables
in the case of cyclic transmission
Data volume with PROFINET CBA, max.
• as useful data for digital inputs in 8 192 bytes Performance data
the case of PROFINET CBA, max. PROFINET CBA, HMI variables via
• as useful data for digital outputs in 8 192 bytes PROFINET (acyclic)
the case of PROFINET CBA, max. Number of HMI stations with login 3
• as useful data for arrays and data capability for HMI variables in the
types case of acyclic transmission with
PROFINET CBA
- in case of acyclic transmission 8 192 bytes
with PROFINET CBA, max. Send cycle of the HMI variables in 500 ms
the case of acyclic transmission
- in case of cyclic transmission 250 bytes
with PROFINET CBA
with PROFINET CBA, max.
- in case of local interconnection 2 400 bytes Send cycle of the HMI variables in 200
with PROFINET CBA, max. the case of acyclic transmission
with PROFINET CBA max.
Performance data PROFINET
Data volume as useful data for 8 192 bytes
CBA, remote interconnections
HMI variables in the case of
with acyclic transmission
acyclic transmission with
Send cycle of the remote intercon- 100 ms PROFINET CBA max.
nections in the case of acyclic
Performance data
transmission with PROFINET CBA
PROFINET CBA, device-internal
Number of remote interconnections
interconnections Number of interconnections in the 300
• with input variables 150 case of PROFINET CBA, max
in case of acyclic transmission Data volume of internal inter- 2 400 bytes
with PROFINET CBA, max. connections in the case of
• with output variables 150 PROFINET CBA, max
in case of acyclic transmission Performance data
with PROFINET CBA, max. PROFINET CBA, interconnections
Data volume with constants
SIMATIC S7-400
Communication
CP 443-1 Advanced
SIMATIC S7-400
Communication
CP 443-1 Advanced
SIMATIC S7-400
Modules for SIMATIC S7-400H
Y link for S7-400H
■ Overview
• Transceiver for the transition from a redundant PROFIBUS DP
master system to a single-channel PROFIBUS DP master
system
• To connect devices with a single PROFIBUS DP interface to
the redundant PROFIBUS DP master system of the SIMATIC
S7-400H
5
■ Technical specifications
6ES7 153-2BA02-0XB0 6ES7 153-2BA02-0XB0
Supply voltages 1st interface
Rated value DP slave
• Permissible range (ripple 20.4 V • GSD file SI04801.GSG
included), lower limit (DC)
CPU/programming
• permissible range (ripple 28.8 V
included), upper limit (DC) Configuration software
external protection for supply 2.5 A Number of stampable digital 128; Max. 128 signals / station;
cables (recommendation) inputs, max. max. 32 signals / slot
SIMATIC S7-400
Modules for SIMATIC S7-400H
Y link for S7-400H
SIMATIC S7-400
Modules for SIMATIC S7-400F/FH
IM 153-1/153-2
■ Overview
IM 153-1 Standard
The IM 153-1 is one reasonably priced version that is best suited
for most applications in the manufacturing environment. It
permits the use of up to eight S7-300 I/O modules.
IM 153-2 High Feature
For higher requirements in manufacturing technology, such as
the use of F-technology or the highest performance in
conjunction with clock synchronization, the IM 153-2 High
Feature is available. This IM is also designed for use with the
PCS 7 in the field of manufacturing applications. This IM can be
redundantly used and supports typical functions as they are
required in the control field. These include, for example, clock
synchronization or time stamping with an accuracy of up to
1 ms.
■ Technical specifications
6ES7 153-1AA03-0XB0 6ES7 153-2BA02-0XB0 6ES7 153-2BA82-0XB0 6ES7 153-2BB00-0XB0
Power supply
Input current
• Rated value at DC 24 V 625 mA
Output voltage
• Rated value, DC 5 V Yes Yes Yes
Output current
• for backplane bus (DC 5 V), 1A 1.5 A 1A
max.
Supply voltages
Rated value
• DC 24 V Yes Yes Yes
• Permissible range (ripple 20.4 V 20.4 V 20.4 V 20.4 V
included), lower limit (DC)
• permissible range (ripple 28.8 V 28.8 V 28.8 V 28.8 V
included), upper limit (DC)
external protection for supply not necessary 2.5A 2.5A not necessary
cables (recommendation)
Power supply and voltage
jumpering
• Mains/voltage failure 5 ms 20 ms 20 ms
jumpering
Current consumption
Current consumption, max. 350 mA; At 24 V DC 600 mA 600 mA 500 mA; At 24 V DC
Inrush current, typ. 2.5 A 3A 3A 3.5 A
I²t 0.1 A²s 0.1 A²s 0.1 A²s 0.1 A²s
Current consumption/
power loss
Power loss, typ. 3W 5.5 W 5.5 W 4.5 W
SIMATIC S7-400
Modules for SIMATIC S7-400F/FH
IM 153-1/153-2
SIMATIC S7-400
Modules for SIMATIC S7-400F/FH
IM 153-1/153-2
5 Air pressure
• Operating height above sea 3 000 m 3 000 m 3 000 m 3 000 m
level, max.
Degree of protection
IP 20 Yes Yes Yes Yes
General information
Vendor identification (VendorID) 801Dh 801E 801E 8071h
Dimensions
Dimensions
• Width 40 mm 40 mm 40 mm 40 mm
• Height 125 mm 125 mm 125 mm 125 mm
• Depth 117 mm 117 mm 117 mm 117 mm
Weights
• Weight, approx. 360 g 360 g 360 g 360 g
SIMATIC S7-400
Modules for SIMATIC S7-400F/FH
IM 153-1/153-2
SIMATIC S7-400
Modules for SIMATIC S7-400F/FH
SIPLUS IM 153-1/153-2
■ Overview
• For connecting ET 200M as a slave to PROFIBUS DP (via
copper conductors)
• IM 153-2 also for use in redundant PROFIBUS DP systems
with S7-400H, software redundancy and S5-155H
• With time stamp functionality and time synchronization
• Suitable for isochronous mode
5
SIPLUS IM 153-1 SIPLUS IM 153-2
Order No. 6AG1 153-1AA03-2XB0 6AG1 153-2BA02-7XB0
Order No. based on 6ES7 153-1AA03-0XB0 6ES7 153-2BA02-0XB0
Ambient temperature range -25 ... +60 °C -25 ... +70 °C
Condensation permissible -25 ... +60 °C (for applications with cUL approval),
condensation permissible
Environmental conditions Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere)
Approvals CE. UL haz. Loc. CE
Conforms with standard for Yes No
electronic equipment used on
rolling stock (EN 50155,
temperature T1, category 1).
Technical data The technical data are identical with those of the based-on modules.
SIPLUS bus module for accommodating an for accommodating two for accommodating a PS For accommodating two
80 mm module IM 153-2 and an IM 153 40 mm wide I/O modules
Order No. 6AG1 195-7HC00-2XA0 6AG1 195-7HD10-2XA0 6AG1 195-7HA00-2XA0 6AG1 195-7HB00-7XA0
Order No. based on 6ES7 195-7HC00-0XA0 6ES7 195-7HD10-0XA0 6ES7 195-7HA00-0XA0 6ES7 195-7HB00-0XA0
Ambient temperature range -25 ... +60 °C
Condensation permissible
Environmental conditions Suited for exceptional medial exposure (e.g. by chlorine sulfur atmosphere)
Approvals CE, cUL (available soon) CE, UL haz. Loc. CE. UL haz. Loc.
Conforms with standard for No No No No
electronic equipment used on
rolling stock (EN 50155,
temperature T1, category 1).
Technical data The technical data are identical with those of the based-on modules.
SIMATIC S7-400
Modules for SIMATIC S7-400F/FH
SIPLUS IM 153-1/153-2
SIMATIC S7-400
Modules for SIMATIC S7-400F/FH
Isolation module
SIMATIC S7-400
Modules for SIMATIC S7-400F/FH
SIPLUS isolating module
■ Overview
• Failsafe input/output modules for use with the SIMATIC
S7-400F/FH
• With integrated safety functions
• Can only be plugged into the ET 200M
• Achievable safety classes in safety operation: SIL 2, SIL 3 to
IEC 61508, AK 4, AK 6 to DIN V 19250, Category 3, 4 to
EN 954-1
• Use in standard mode with high diagnostics requirements
• Also suitable for redundant operation
For further information see section 4, page 111.
SIMATIC S7-400
Connection methods
Front connectors
SIMATIC S7-400
Connection methods
Fully modular connection
■ Overview
Basic modules
5
The fully modular connection is the standard connection for the
SIMATIC S7-300/400. The fully modular connection facilitates
convenient, fast, and correct connection of the I/O to the In the case of the basic module, the connection modules are
SIMATIC S7-300/400. used with basic functionality. Here, the I/O signal is connected
quickly and simply from the field to the module or from the
• Easy plugging in of front connector module, connecting cable module to the field.
and connection module
The connection terminals for the I/O signals are designed as
• Fast and low-cost wiring screw terminals or spring terminals. The connection modules are
• Supply voltage connectable to front connector module or available for digital and analog signals.
connection module for digital and analog signals
Signal modules
• Reduction in wiring errors, clear control cabinet wiring
• Distribution of digital signals by byte or by double-byte
• Each component can be replaced individually.
• Every cable length can be configured without cutting, or
pre-assembled cables can be used
Connecting cables
SIMATIC S7-400
Connection methods
Fully modular connection
SIMATIC S7-400
Connection methods
Fully modular connection
Technical data of connecting cable from SIMATIC S7 to connection Max. operating voltage 60 V DC
module Continuous current signal 1A
Operating voltage 60 V DC conductor
SIMATIC S7-400
Connection methods
Fully modular connection
6ES7 924-0CA10-0B_0
• mechanical 5 x 106 operating cycles
• for 2 x 8 signals with LED Approx. 100 x 43.2 x 80
6ES7 924-1AA10-0B_0 • electrical 3 x 104 operating cycles at 230 V
AC/2 A/ cos ϕ = 1
Operating temperature 0 to +60 °C
Connection module TP2 with LED Mounting position Any
Max. operating voltage 24 V DC Air gaps and creepage distances Basic standard IEC 60664-1;
Continuous current per signal 2A UL 508; Cul
conductor (Reference CSA C22.2 No. 142)
overvoltage category III
Operating temperature 0 to + 60 °C pollution degree 2
Mounting position Any Dimensions (W x H x D) in mm
Air gaps and creepage distances EC Report 664, IEC 664 A, 6ES7 924-0BD10-0B_0 Approx. 100 x 45 x 80
IEC 1131 T2,
CSA C22.2 No 142 UL 508,
VDE 0160 (12.90), overvoltage
category II, pollution degree 3 Connection module with relay for inputs (TPRi)
• for 2-ampere modules with LED Approx. 68 x 43.2 x 80 Operating voltage for coil 230 VAC
6ES7 924-0BB10-0B_0 from 207 – 280 V AC
Input circuit Varistors
Number of wires per 1 or a combination of 2 conductors up to Air gaps and creepage distances Basic standard IEC 60664-1;
connection the cross-sections specified above (total) UL 508; Cul
in a shared wire end ferrule (Reference CSA C22.2 No. 142)
overvoltage category III
Blade width of the screw- 3.5 mm (cylindrical shape) pollution degree 2
driver
Dimensions (W x H x D) in mm
Tightening torque for - 0.4 to 0.7 Nm
connecting the cables 6ES7 924-0BE10-0B_0 Approx. 120 x 45 x 80
SIMATIC S7-400
Connection methods
Fully modular connection
SIMATIC S7-400
Connection methods
Fully modular connection
■ Ordering data basic modules Order No. ■ Ordering data signal modules Order No.
Connection module TP1 Connection module TP1 with
LED
for 1-wire initiators
for 1-wire initiators
Packaging unit (1 unit)
Packaging unit (1 unit)
• Spring terminals 6ES7 924-0AA10-0AB0
• Spring terminals 6ES7 924-0AA10-0BB0
• Screw terminals 6ES7 924-0AA10-0AA0
• Screw terminals 6ES7 924-0AA10-0BA0
Connection module TP3
Connection module TP3 with
for 3-wire initiators LED
Packaging unit (1 unit) for 3-wire initiators
• Spring terminals 6ES7 924-0CA10-0AB0 Packaging unit (1 unit)
• Screw terminals 6ES7 924-0CA10-0AA0 • Spring terminals 6ES7 924-0CA10-0BB0
Connection module TPK • Screw terminals 6ES7 924-0CA10-0BA0
for 2 x 8 signals Connection module TPK with
5 Packaging unit (1 unit) LED
for 2 x 8 signals
• Spring terminals 6ES7 924-1AA10-0AB0
• Screw terminals 6ES7 924-1AA10-0AA0 Packaging unit (1 unit)
Connection module TP2 • Spring terminals 6ES7 924-1AA10-0BB0
for 2 A modules • Screw terminals 6ES7 924-1AA10-0BA0
for 2-wire initiators Connection module TP2 with
LED
Packaging unit (1 unit)
for 2 A modules
• Spring terminals 6ES7 924-0BB10-0AB0
for 2-wire initiators
• Screw terminals 6ES7 924-0BB10-0AA0
Packaging unit (1 unit)
Connection module TPA
• Spring terminals 6ES7 924-0BB10-0BB0
for analog signals
• Screw terminals 6ES7 924-0BB10-0BA0
Packaging unit (1 unit)
Accessories
• Spring terminals 6ES7 924-0CC10-0AB0
Labeling plates for connection
• Screw terminals 6ES7 924-0CC10-0AA0
modules
Insertable labeling plate 6ES7 928-2AB00-0AA0
Accessories PU = 200 units
Labeling plates Self-adhesive labeling plate 6ES7 928-2BB00-0AA0
for connection modules PU = 200 units
Insertable labeling plate 6ES7 928-2AB00-0AA0
PU = 200 units
Self-adhesive labeling plate 6ES7 928-2BB00-0AA0
PU = 200 units
Shield plate 6ES7 928-1BA00-0AA0
for analog connection module
(4 units)
Shield connection terminal
for shield plate, 2 units, with cable
diameter
• 2 to 6 mm (2 cables) 6ES7 390-5AB00-0AA0
• 3 to 8 mm 6ES7 390-5BA00-0AA0
• 4 to 13 mm 6ES7 390-5CA00-0AA0
SIMATIC S7-400
Connection methods
Fully modular connection
■ Ordering data
function modules Order No. Order No.
Connection module TPRo for Accessories
output signals
Labeling plates for connection
for 2-wire connection modules
Packaging unit (1 unit) Insertable labeling plate 6ES7 928-2AB00-0AA0
PU = 200 units
• Spring terminals 6ES7 924-0BD10-0BB0
Self-adhesive labeling plate 6ES7 928-2BB00-0AA0
• Screw terminals 6ES7 924-0BD10-0BA0 PU = 200 units
Connection module TPRi for Replacement relay for relay
input signals connection module
for 2-wire connection PU = 4 units
Packaging unit (1 unit) Replacement relay for TPRi 6ES7 928-3BA00-4AA0
• Spring terminals 6ES7 924-0BE10-0BB0 Replacement relay for TPRo 6ES7 928-3AA00-4AA0
• Screw terminals 6ES7 924-0BE10-0BA0 Optocoupler DC alternative 6ES7 928-3DA00-4AA0
for relay in the case of TPRo
PU = 4 units 5
Optocoupler AC alternative 6ES7 928-3CA00-4AA0
for relay in the case of TPRo
PU = 4 units
SIMATIC S7-400
Connection methods
Flexible connection
SIMATIC S7-400
Racks
Racks
■ Overview
CR2 (Central Rack)
• For setting up central controllers
• For holding up to 18 modules
• Segmented rack:
For operating two mutually independent S7-400 CPUs without
S7-400 Multicomputing, but with communication between the
CPUs over the backplane bus (C bus). Both CPUs can
address their own local I/O modules (segmented P bus).
CR3 (Central Rack)
• For configuring central racks
• Optimized for distributed automation solutions due to holding
up to 4 modules
UR2-H
• For configuring a complete S7-400H system in one subrack
• Also suitable for S7-400:
5
Operation of 2 separate CPUs with their own I/O (separate
• The basic mechanical framework of the SIMATIC S7-400/ P and C buses)
S7-400H • Can also be used as an expansion unit
• For accommodating the modules, supplying them with • For holding up to 18 modules
operating voltage and connecting them via the backplane bus
• Also available as aluminum rack
• Several versions for configuring central controllers and
expansion racks ER1 (Extension Rack)
UR1 (Universal Rack) • For setting up expansion units economically
• For setting up central controllers and expansion units • For holding up to 18 modules with restricted functionality
• For holding up to 18 modules • Also suitable for S7-400H
• Also suitable for S7-400H • Also available as aluminum rack
• Also available as aluminum rack ER2 (Extension Rack)
UR2 (Universal Rack) • For setting up expansion units economically
• For setting up central controllers and expansion units • For holding up to 9 modules with restricted functionality
• For holding up to 9 modules • Also suitable for S7-400H
• Also suitable for S7-400H • Also available as aluminum rack
• Also available as aluminum rack
■ Technical specifications
6ES7 400-1TA01- 6ES7 400-1TA11- 6ES7 400- 6ES7 400- 6ES7 401-2TA01- 6ES7 401-
0AA0 0AA0 1JA01-0AA0 1JA11-0AA0 0AA0 1DA01-0AA0
Hardware config.
Number of single-width slots, 18 18 9 9 18; 2 segments 4
max. with 8 or 10 slots
Rack
• K bus Yes Yes Yes Yes Yes Yes
• P bus Yes Yes Yes Yes Yes Yes
Dimensions
Dimensions
• Width 482.5 mm 482.5 mm 257.5 mm 257.5 mm 482.5 mm 130 mm
• Height 290 mm 290 mm 290 mm 290 mm 290 mm 290 mm
• Depth 27.5 mm 27.5 mm 27.5 mm 27.5 mm 27.5 mm 27.5 mm
Weights
• Weight, approx. 4 200 g 3 000 g 2 200 g 1 500 g 4 200 g 750 g
SIMATIC S7-400
Racks
Racks
UR2 aluminum rack 6ES7 400-1JA11-0AA0 for expansion units, P bus only, 18
slots
for central controllers and
expansion units, 9 slots ER2 rack 6ES7 403-1JA01-0AA0
SIMATIC S7-400
Racks
Fan subassembly
5
• permissible range, upper 132 V AC or
limit (AC) 264 V AC
• permissible frequency 47 Hz
• Fans for the SIMATIC S7-400 range, lower limit
• Necessary when using modules that generate an extremely • permissible frequency 63 Hz
large amount of heat range, upper limit
Current consumption
Inrush current, typ. 0.9 A; at 24 V 0.6 A at rated
voltage 230 V AC:
1.15 A: at rated
voltage 120 V AC
Current consumption/
power loss
Power loss, max. 11 W 20 W
Relay outputs
Rated input voltage of relay 24 V 24 V
L+ (DC)
Switching capacity of the
contacts
• with resistive load, max. 200 mA 200 mA
Dimensions
Dimensions
• Width 482.5 mm 482.5 mm
• Height 109.5 mm 109.5 mm
• Depth 235 mm 235 mm
Weights
• Weight, approx. 1.6 kg 2 kg
SIMATIC S7-400
Racks
Expansion racks
■ Overview
• SIMATIC S5 expansion racks for distributed expansion of the The following requirements must be met for expansion:
SIMATIC S7-400 • IM 463-2 interface module plugged into the SIMATIC S7-400
• For connection to existing SIMATIC S5 systems central controller
The following components can be connected to the SIMATIC • IM 314 interface module plugged into SIMATIC S5 expansion
S7-400: racks
• Expansion racks ER 701-2 and ER 701-3 from the • Maximum configuration:
SIMATIC S5-115U series • Up to 32 SIMATIC S5 expansion racks can be connected to
• Expansion racks EG 183U and EG 185U from the one S7-400 central controller
SIMATIC S5-135U/-155U series • Transmission distance:
The maximum permissible distance between the central
controller and the last expansion rack on a line is 600 m
SIMATIC S7-400
Interface modules
IM 460-0
SIMATIC S7-400
Interface modules
IM 461-0
5 • Height
• Depth
290 mm
217 mm
SIMATIC S7-400
Interface modules
IM 460-1
SIMATIC S7-400
Interface modules
IM 461-1
5 • Height
• Depth
290 mm
217 mm
SIMATIC S7-400
Interface modules
IM 460-3
SIMATIC S7-400
Interface modules
IM 461-3
5 • Height
• Depth
290 mm
217 mm
• Transmission of data from the P-bus and C-bus • Weight, approx. 620 g
• Can be plugged into expansion rack
• To be used exclusively with IM 460-3
■ Ordering data Order No.
IM 461-3 interface module 6ES7 461-3AA01-0AA0
Receive interface module for
distributed connection up to
102 m; with C bus transmission
468-1 connecting cable
between IM 460-3 and IM 461-3
0.75 m 6ES7 468-1AH50-0AA0
1.5 m 6ES7 468-1BB50-0AA0
5m 6ES7 468-1BF00-0AA0
10 m 6ES7 468-1CB00-0AA0
25 m 6ES7 468-1CC50-0AA0
50 m 6ES7 468-1CF00-0AA0
100 m 6ES7 468-1DB00-0AA0
Terminating connector 6ES7 461-3AA00-7AA0
for IM 461-3
SIMATIC S7-400
Interface modules
IM 463-2
SIMATIC S7-400
Power supplies
PS 405/407 power supply
■ Overview
• Power supplies for SIMATIC S7-400
• For conversion of AC or DC line voltages to the 5 V DC and
24 V DC operating voltages required
• 4 A, 10 A and 20 A output currents
• In addition:
- SIPLUS power supply 6AG1 405-0KA02-2AA0 for temper-
ature range of -25 to +60 °C and use under medium load
(e.g. chlorine/sulfur atmosphere). Technical specifications
similar to 6ES7 405-0KA02-0AA0
- SIPLUS power supply 6AG1 407-0KA02-4AA0 for use under
medium load (e.g. chlorine/sulfur atmosphere). Technical
specifications similar to 6ES7 407-0KA02-0AA0
- SIPLUS power supply 6AG1 407-0KR02-4AA0 for use under
medium load (e.g. chlorine/sulfur atmosphere). Technical
specifications similar to 6ES7 407-0KR02-0AA0
5
■ Technical specifications
6ES7 405-0DA02-0AA0 6ES7 405-0KA02-0AA0 6ES7 405-0KR02-0AA0 6ES7 405-0RA02-0AA0
Power supply
Input voltage
• Rated value, DC 24 V Yes Yes Yes Yes
• Rated value, DC 48 V Yes Yes Yes Yes
• Rated value, DC 60 V Yes Yes Yes Yes
• permissible range, lower limit 19.2 V; dynamic 18.5 V Static 19.2 V, 19.2 V; dynamic 18.5 V static 19.2 V,
(DC) dynamic 18.5 V dynamic 18.5 V
• permissible range, upper limit 72 V; dynamic 75.5 V static 72 V, 72 V; dynamic 75.5 V static: 72 V
(DC) dynamic 75.5 V dynamic 75.5 V
Input current
• Rated value at DC 24 V 2A 4A 4A 7A
• Rated value at DC 48 V 1 000 mA 2A 2A 3.2 A
• Rated value at DC 60 V 800 mA 1.6 A 1.6 A 2.5 A
• Inrush current, max. 18 A; Full width at half 18 A; Full width at half 18 A; Full width at half 56 A; Full width at half
maximum 20 ms maximum 20 ms maximum 20 ms maximum 1.5 ms
Output voltage
• Rated value, DC 5 V Yes Yes Yes Yes
• Rated value, DC 24 V Yes Yes Yes Yes
Output current
• for backplane bus (DC 5 V), 4A 10 A; no base load 10 A; no base load 20 A; no base load
max. required required required
• for backplane bus (DC 24 V), 0.5 A 1 A; idling-proof 1 A; idling-proof 1 A; idling-proof
max.
• Short-circuit protection Yes Yes Yes Yes
Supply voltages
Power supply and voltage
jumpering
• Mains/voltage failure 20 ms 20 ms 20 ms 20 ms
jumpering
• Mains/power failure jumper to Yes Yes Yes Yes
NAMUR recommendation
Current consumption/
power loss
Power consumption
• Power consumption, typ. 48 W 95 W 95 W 168 W
SIMATIC S7-400
Power supplies
PS 405/407 power supply
SIMATIC S7-400
Power supplies
PS 405/407 power supply
5
• Rated value at AC 120 V 0.42 A 0.9 A 0.9 A 1.4 A
• Rated value at AC 230 V 0.22 A 0.5 A 0.5 A 0.7 A
• Inrush current, max. 8.25 A; Full width at half 63 A; Full width at half 63 A; Full width at half 88 A; Full width at half
maximum 5 ms maximum 1 ms maximum 1 ms maximum 1.1 ms
Output voltage
• Rated value, DC 5 V Yes Yes
• Rated value, DC 24 V Yes Yes
Output current
• for backplane bus (DC 5 V), 4 A; no base load required 10 A; no base load 10 A; no base load 20 A; no base load
max. required required required
• for backplane bus (DC 24 V), 0.5 A 1 A; idling-proof 1 A; idling-proof 1 A; idling-proof
max.
• Short-circuit protection Yes Yes Yes Yes
Supply voltages
Power supply and voltage
jumpering
• Mains/voltage failure 20 ms 20 ms 20 ms 20 ms
jumpering
• Mains/power failure jumper to Yes Yes Yes Yes
NAMUR recommendation
Current consumption/
power loss
Power consumption
• Power consumption, typ. 52 W 95 W 95 W
Power loss, typ. 20 W 20 W 20 W 35 W
Backup battery
• Backup battery (optional) Yes; 1 x lithium AA; Yes; 2 x lithium AA; Yes; 2 x lithium AA; Yes; 2 x lithium AA;
3.6 V/2.3 Ah 3.6 V/2.3 Ah 3.6 V/2.3 Ah 3.6 V/2.3 Ah
Connection point
Connecting cables/cross 3x 1.5 mm2, solid or 3x 1.5 mm2, solid or 3x 1.5 mm2, solid or 3x 1.5 mm2, solid or
sections stranded wire with end stranded wire with end stranded wire with end stranded wire with end
sleeve, external diameter sleeve, external diameter sleeve, external diameter sleeve, external diameter
3 to 9 mm 3 to 9 mm 3 to 9 mm 3 to 9 mm
Isolation
primary/secondary Yes Yes Yes Yes
EMC
• Observance of line harmonic Yes Yes Yes Yes
distortion to IEC 61000-3-2,
IEC 61000-3-3
SIMATIC S7-400
Power supplies
PS 405/407 power supply
SIMATIC S7-400
Accessories
Labeling sheets
■ Overview
Labeling sheets Label cover
• Film sheets for application-specific labeling of SIMATIC • Film to cover and hold user-made labeling strips on normal
S7-400 I/O modules with commercial laser printers paper
• Single-color films, tear-resistant, dirt-resistant • Accessories, 10 pieces
• Easy handling:
- Pre-perforated labeling sheets in DIN A4 format to allow
easy separation of the labeling strips
- The separated strips can be inserted directly into the I/O
modules
• Different colors for distinction between module types or
preferred areas of application:
The labeling sheets are available in the colors teal, light beige,
red and yellow. Yellow is reserved for failsafe systems.
5 ■ Technical specifications
6ES7 492-2AX00- 6ES7 492-2BX00- 6ES7 492-2CX00- 6ES7 492-2DX00- 6ES7 492-2XX00-
0AA0 0AA0 0AA0 0AA0 0AA0
Dimensions
Weights
• Weight, approx. 2g 2g 2g 2g 72 g
SIMATIC S7-400
Accessories
Spare parts
Cover film for labeling strips Cover foil for labeling strip 6ES7 492-2XX00-0AA0
• Teal-colored film for covering and fixing user-created labeling 10 units (spare part)
strips Range card for analog input 6ES7 974-0AA00-0AA0
• On standard paper modules
• Spare part 1 card for 2 inputs; 2 units (spare
part)
Measuring range module for analog input modules
Slot covers 6ES7 490-1AA00-0AA0
• Plug-in module for selecting the input ranges for analog
modules for racks; 10 units (spare part)
SIMATIC S7-400