0% found this document useful (0 votes)
50 views

Modulador Digital IP To RF User's Manual - V1.0

This document is the user manual for the NX0416 ISDB modulator. It describes the key features and specifications of the modulator, how to operate it, and troubleshoot common problems. The modulator supports up to 128 IP and TS inputs, 4 MPTS outputs, and 16 ISDB channels. The user manual explains how to install the device, access the web-based interface, configure parameters like multiplexing and modulation settings, and upgrade the system software. It also provides prevention measures and solutions for issues like boot or signal failures.

Uploaded by

josehv7
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views

Modulador Digital IP To RF User's Manual - V1.0

This document is the user manual for the NX0416 ISDB modulator. It describes the key features and specifications of the modulator, how to operate it, and troubleshoot common problems. The modulator supports up to 128 IP and TS inputs, 4 MPTS outputs, and 16 ISDB channels. The user manual explains how to install the device, access the web-based interface, configure parameters like multiplexing and modulation settings, and upgrade the system software. It also provides prevention measures and solutions for issues like boot or signal failures.

Uploaded by

josehv7
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 12

VEK-IP to RF

IP /ASI to ISDB Modulator

User's Manual

Dear clients,
In order to give better play to the function of your device, we suggest that you take the precious
time to read the user manual carefully before connecting and operating the device, so that you can
master the use method and use points of the device.
Please keep this manual for future reference.
NX0416 user's manual

Contents

1. Introduction...............................................................3

1.1 Product Overview..........................................................3

1.2 Key Features..............................................................3

1.3 Specifications.............................................................4

1.4 Interface..................................................................5

2. Operation.................................................................6

2.1 Installation...............................................................6

2.2 Connect.................................................................6

2.3 Parameter Settings.........................................................7

2.3.1 TS Multiplex Settings.................................................7

2.3.2 odulation Parameter..................................................8

2.3.3 MPTS IP Stream.....................................................8

2.3.4 Network Settings.....................................................9

2.3.5 Configuration.......................................................9

2.3.5 System Upgrade....................................................10

2.3.6 LOG..............................................................10

3. Trouble Removal..........................................................11

3.1 Prevention Measures......................................................11

3.2 Common Problems........................................................11

4. Packing list..............................................................12

2 / 12
NX0416 user's manual

1. Introduction

1.1 Product Overview

This is a cost-effective ISDB modulator developed according to ISDB (EN300744) standard. It


has 128 IP inputs. After multiplexing and modulating process, it gives 16 ISDB non-adjacent carriers
(50MHz~960MHz) output through the RF output interface. To meet customers’ various
requirements, this device is also equipped with data port for 4 MPTS output over UDP and RTP. This
is very adaptable to newly generation DTV broadcasting system.

1.2 Key Features


 Support maximum 4*128 IP input (MPTS/SPTS) over UDP and RTP protocol

 Support 4*4 groups ISDB modulating

 Support 4*2 Serial TS Input (Any Multiplex)

 Support 2 Serial TS Output

 Integrated multiplexing and modulating functions

 Support accurate PCR adjusting/PID Remapping/PSI/SI rebuilding and editing

 Web-based NMS management

1.3 Specifications

Modulation Standard ARIB STD-B31

3 / 12
NX0416 user's manual

FFT mode 2K

Bandwidth 6M, 7M, 8M

Constellation DQPSK, QPSK, 16QAM, 64QAM

RF out 4*4 ISDB,16 Channels ISDB,

 RF frequency  50~900MHz,1kHz step

 RF output level  -24dBm~0dBm

 MER  ≥40db

Guard Interval 1/32, 1/16, 1/8, 1/4

4ch 128 IP(SPTS/MPTS) input over UDP and RTP, RJ45,1000M/100M,


IP Input
Unicast/Multicast

 LCD/Keyboard operating and web-based NMS support


System
 Ethernet software upgrading

 Dimension
440mm×380mm×40mm
(W*D*H)

General  Temperature 0~45℃(work) ;-20~80℃(storage)

AC 110V±10%,50/60Hz
 Power supply
AC 220V±10%,50/60Hz

4 / 12
NX0416 user's manual

1.4 Interface

Number Interface Overview


1 RF out: 4/8/12/16 ch Frequency Output

2 ASI IN: Serial TS Input (Any Multiplex)

3 ASI OUT: Serial TS Output

4 NMS: Network Management System

5 DATA: 128 SPTS/MPTS IP input /4 MPTS output

6 Power Switch

DATA: 128 SPTS/MPTS IP input

NMS: Modulation Module Network Management System(backups)


7
ASI IN: Serial TS Input (any multiplex)

RF OUT: 4/8/12/16 ch Frequency Output

5 / 12
NX0416 user's manual

2. Operation

2.1 Installation 
Check the possible loss or damage of the equipment during transportation before installing the
equipment; Prepare the appropriate environment, connect > to the signal line, connect > to the power
line, open the device, >, check the IP address of the network manager, >, adjust the network manager
server, connect > to the network manager, check or modify all parameters, and then the device will
be normally used after no abnormalities are found in >.
Note 1: the power supply must meet the working requirements of the equipment, such as
voltage, frequency and power supply capacity.
Note 2: please observe the environment before the test and pay attention to safety during the
test.

2.2 Connect
 Set the computer and the device IP in the same network segment according to the device network
manager address (192.168.0.136)

 The IP address of the computer cannot be the same as that of the device

 In the address bar of Firefox browser, ENTER: 192.168.0.136 and press "ENTER". ENTER the
user name: admin password: admin and ENTER the configuration window of the digital TV
modulator.

6 / 12
NX0416 user's manual

2.3 Parameter Settings


2.3.1 TS Multiplex Settings

The input interface is on the left and the output interface is on the right

L1-L3 corresponds to three interface boards in the back panel

In the TS stream setting column, parameters of the output channel can be set: stream selection,
general parameters, PID transparent transmission. Mainly is carries on the choice to the output
program.

In this interface, you can click the "+" button and input the corresponding IP address to add the input
program source.

After the program source is added into the device as required, the selected program can be output or
deleted through the arrow to the right and left of ">" "<" ">>" "<<".

7 / 12
NX0416 user's manual

2.3.2 Modulation Parameter

4 output channel status, parameter view, modulation mode setting, etc

2.3.3 MPTS IP Stream

4 MPTS IP output channel status, parameter view, setting, etc

8 / 12
NX0416 user's manual

2.3.4 Network Settings

Set 4 IPTV input IP address and other parameters

2.3.5 Configuration

Save or restore the device system configuration, or load other configuration parameters

9 / 12
NX0416 user's manual

2.3.5 System Upgrade

2.3.6 LOG

Device status information

10 / 12
NX0416 user's manual

3. Trouble Removal

3.1 Prevention Measures


1)Put equipment in the environmental temperature 0 ℃ ~ 45 ℃, other conditions meet the
requirements of operating range.
2)Check that the supply voltage is within the specified range and that all connections are
correct.
3)Check that the supply voltage is within the specified range and that all connections are
correct.
4)Please do not switch the machine frequently (switch the machine at least every 10 seconds or
more).

3.2 Common Problems

Common problems The solution

Check that the input voltage and connection of the power supply
boot failure
operating range are correct

Check whether the signal source is normal.


signal failure
Check that the cables are properly connected

The program name and program number of the output signal are
Program Scan failure
manually added in the TS stream setting

11 / 12
NX0416 user's manual

4. Packing list

Number Name Count Comment


1 NX0416 Modulator 1
2 Power line 1
3 ASI 1

12 / 12