1) The document provides instructions for safely operating a weighing indicator. 2) Key warnings include only allowing professional staff to calibrate the device and ensuring proper grounding. 3) The document covers installation, operation, calibration, output formats and maintenance of the weighing indicator.

Uploaded by

cristoba muñoz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views54 pages

LP7516 Usermanual11.03.02

1) The document provides instructions for safely operating a weighing indicator. 2) Key warnings include only allowing professional staff to calibrate the device and ensuring proper grounding. 3) The document covers installation, operation, calibration, output formats and maintenance of the weighing indicator.

Uploaded by

cristoba muñoz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 54

 

 
 
 
 
 
 
 
 
 

Weighing Indicator 
 
 
 
 
User manual 
 
 
 
 
   
                                                 User Manual 
 
 
 

safety instruction 
 ​
 
For safety operation pls. follow the safety instruction. 
 

WARNING 
      ​

set.  Calibrate,  inspect  and  fix  the  the weighing indicator is  prohibited by Non 


professional staff 
 
 
 

WARNING 
      ​

Pls. make sure the weighing display well earthing  
 
 
 

WARNING 
      ​

The  indicator  is  electrostatic  sensitive  device,   pls.   power   off  


during  electrical  connections,   internal  components  touched by 
hand is prohibited, and please take the anti­static measure  
 
 
LIST 
1. Summary
1.1 Main function

 
  Page 2​ of 27 
 
 
                                                 User Manual 
 
1.2 Technical parameter
1.3 Outline and installation picture
1.4 Battery
2. Installation and Calibration
2.1 connection indicator with load cell
2.2 communication interface
3. Basic operation
3.1 Key and display
3.2 Power on
3.3 Zero setting
3.4 TARE
3.5 HOLD
3.6 TOTAL
3.7  10 times high resolutions
3.8 Up and Low limit alarm
3.9 Print function
4 Calibration & parameter setting
4.1 Enter calibration
4.2. Step of calibration operation:
4.3 Application parameter setting
4.4 Communication setting
4.5 Application setting
4.6 Exit setting
5.Output data format
5.1 Computer continuous sending format
5.2 Big display continuous sending format
5.3 Serial interface reception command:
5.4 Print output format
5.5 Print the accumulated output format
6. Maintenance
6.1 Regular Error and maintain method
6.2 Daily maintenance

 
  Page 3​ of 27 
 
 
                                                 User Manual 
 
6.3 Restore default parameters
 

1. Summary 

1.1 Main function

》General weighing: zero tare  
》Animal weighing: Peak­hold. Data­hold, Auto­hold 
》Accumulation 
》Optional by RS232 
》Low battery remind 
》Power off  automatically 

1.2 Technical parameter

》Stimulating voltage:+3.3 VDC 
》A/D converting speed:  1​ 0 SPS 
》Load signal range: 0~12.8mV 
》load capacity: it can connect 4 pcs 350​ load cell at most 
Ω​
》weight unit:   kg.  
》​ :    3000e 
Resolution​
》Interval:    1/2/5/10/20/50 
》Display:      6­digits LED/LCD,word height: 20.3mm 
》key:     ON/OFF TOTAL HOLD TARE ZERO SET 
 
  Page 4​ of 27 
 
 
                                                 User Manual 
 
》Interface:RS232C  Baud rate optional 1200/2400/4800/9600 
》Operation temperature:      ­10~40℃ 
》​ Storage temperature​ :      ­20~+60℃ 
》optional power:    ​ 4​
V/4Ah rechargeable battery  
                   ​
 110/220VAC 
 
1.3 Outline and installation picture  
 

 
 
 
1.4 Battery 
 
  Page 5​ of 27 
 
 
                                                 User Manual 
 
1.   when  you  use  the  internal  battery  first  time,you  should  charge  the 
battery  10­12   hours,  to  prevent  low  voltage  resulted   from  self  leakage  of 
battery.  
2.   when  the  red  battery  light  is  on  and  flashes,it   means  low  battery  You 
should charge battery in time.  
3. Charge time: 10­12 hours And it works 45 hours 
4. When the battery light turns green, it means fully charged 
5.   If  you  don’t  use  the  battery  long time,  take out  the battery  to  protect  the 
indicator from battery leakage 
6.  In  order to keep  the  battery  in best  using condition,  it  is  suggest  that  you 
fully  discharge  the  battery  every  month,  the   method   is  that  using  the 
indicator till it is automatically power off. 
 
 

2. Installation and Calibration 

2.1 connection indicator with load cell

 
  it can  connect four  pcs 350Ωload  cell  at  most,  both  four  and six  line  load 
cell are ok. To make it simple, we use quick connector 
  Or standard plug. As belows 
 
 
 

 
  Page 6​ of 27 
 
 
                                                 User Manual 
 
 
 
 
 
 
 
 Quick connector connection 
 

2.2 communication interface

 
PIN2­­­­­­­TXD  
   5  4  3   2  1           PIN3­­­­­­RXD 
                             PIN5 ­­­­­­­­GND 
9   8  7  6   
 

3. Basic operation 

3.1 Key and display 


 

 
  Page 7​ of 27 
 
 
                                                 User Manual 
 

 
 
LP7516  Weighing indicator display instruction  

LED display  instruction 

Weighing data display 
 

Kg  Weight unit kg 

HOLD  Hold the data 

Tare  Display tare status 

 
  Page 8​ of 27 
 
 
                                                 User Manual 
 

Net  Display net weight 

Gross  Display gross weight 

  Display data keep still 

  zero, indicating zero weight 

Battery  Using battery 
Hi  Over Limit 
OK  Within Limit 
Lo  Below Limit 
Total  Accumulation 
Count  Counting function 

 
Key’s function  

  ON/OFF, EXIT AND SAVE SETTING 
  LEFT 
 RIGHT 
   DOWN 
   UP 
 CONFIRM, GO TO NEXT STEP 
 

 
  Page 9​ of 27 
 
 
                                                 User Manual 
 

Key symbol  Key name  Key function 

  Work together with ​
“on/off”  enter  and exit 
SET  calibration 
 

   
ZERO  Clear weight within zero range 
 

1.At Gross mode, tare the loaded weight 
TARE  2.At   Net  mode,  display  gross  weight  after 
  deduct tare 
   
HOLD  Enter and exit “hold” mold 
   
 
TOTAL   accumulating operation 
 

 
Press  it for 2 seconds to power on or  power  
ON/OFF 
  off 

 
 
 
 

 
  Page 10​
 of 27 
 
 
                                                 User Manual 
 

3.2 Power on

 Power on and indicator perform self­checking and go to weighing mode. 

3.3 Zero setting

Within zero range, press “zero”, indicator weighing is cleared. When  
Indicator is not stable, zero is unworkable. 
 

3.4 TARE

 
At  the  gross weight mode,  if  the  weight is stable, pls. press ”Tare” key   , the 
indicator will take the loaded weight as tare, and show net weight, 
At  this  time  the  gross mode will change  to  net  mode. The “ net”  and  “tare” 
light is on, and the net weight is zero 
 

3.5 HOLD

C11=0 “hold” function unworkable 
 
C11=1 PEAK HOLD 
Press” HOLD” key, the Hold light is on, and show the Maximum data on the 
 
  Page 11​
 of 27 
 
 
                                                 User Manual 
 
weighing indicator. Press “ HOLD” key again to exit the hold function 
 
C11=2 Data­hold  
Press” HOLD” key, the Hold light  is on,  and  show the data on the weighing 
indicator. Press “ HOLD” key again to exit the hold function 
 
C11=3 Auto­hold 
If the weight  on  the scales above 20d and keep stable, the indicator will show 
the  data  for  6  seconds  and  the  “  hold”  light  Is  on  ,  after  6  seconds  the 
indicator back to general weighing, and the “ hold” light is off 
 
C11=4 Special Animal weighing function 
Press” Hold”  key, the indicator  will  show”  LOC”  for 3 seconds, the “ hold” 
light is  on,  During  the  3  seconds,  the indicator will catch the average weight 
and show it. 
Press” HOLD” key again to exit it 
 

3.6 TOTAL

Accumulation operation 
At  Zero  mode,  load  weight  till  stable,  Press   “TOTAL”  key  go  to 
accumulating  
Mode,”  total”  light  on,  display”  n001”,  and  then  display  loaded  weight; 
unload  weight  , back  to  zero, load weight again  till stable. Press ”TOTAL”, 
display”n002” 
Then show the loaded weight. Repeat it maximum 999 times. 
Check the total weight operation: 
Press   “SET”  hold  it  then press  “TOTAL” At the same time,  display  ”n**”, 
(accumulating times) then display total weight. 
 
 
  Page 12​
 of 27 
 
 
                                                 User Manual 
 
There are 8 data totally. It shows the first 4 digital. then the last 4 digital 
For example, the first 4 digital is”0012”, the last 4 digital is”34,56” 
It means the actual weight is “1234.56” 
 
At  TOTAL  (accumulate)  mode,   Press  “TOTAL”  key  the  indicator  show“ 

clrn”,  it  means  don’t   clear  the  total  Weight,  Press  “   key  confirm it  

and exit ; if clear total weight, Press “ ” “ ” 

“clrn”  change to “clry” it means clear total  weight display. Press “ ”to 


clear the the total weight and exit accumulating mode. 

3.7 10 times high resolutions

Press  “ SET” and  “TARE”  key  at  the  same  time, you will get  10  times high 
resolutions. And  it back to normal weighing after 3 seconds. 

3.8 Up and Low limit alarm

Pls.  set  C13=  Up   limit,  C14=Low  Limit,  when  the  weight  is over up limit, 
the  “HI”  light  will on,  and  indicator  will  make  a  sound  to alarm.;  when  the  
weight  is  below than the low limit, the “LO”  light will on.. when the weight 
is within the limit, the “OK” light is ok. 

3.9 Print function

  When  the   data  is  stable,  connection  with  printer,  it  will  be  printed after  
 
  Page 13​
 of 27 
 
 
                                                 User Manual 
 

press“     ”1 second. 
 
 
Note:print  the  gross  weight  when at tare mode  ,  if  the  net  weight  is zero. 
Can not print. 

4  Calibration  &  parameter 

setting 

4.1 Enter calibration

There have two methods to enter the setting menu:  

1.   when  the  switch”  CAL”  is  off,  Press”  ”  then  press”  at  the 
same time, hold it, you will enter C08­C39 setting. 
 2. Take out the sealing screw on the back of indicator, then press  

down  the  “span”  Press   still and  then  press    at  the  same  time , 
you will enter C01­C39 setting. 
 

 
  Page 14​
 of 27 
 
 
                                                 User Manual 
 

4.2. Step of calibration operation:

According to the second method which can enter setting menu, C01­C39 
 
C01 UNIT 
[C01    ]  Press   
[C1    1]  unit is kg  

Press  , go to next step 
C02 Set decimal digits 

[C02    ]  Press   
option:0/1/2/3/4 
[C2    0]   no decimal point 
[C2    1]   one decimal point 
[C2    2]   two decimal point 
[C2    3]   three decimal point 

 Press  , go to next step 
C03 Division setting 
[C03    ]  Press   
[C3    1]  d=1 
[C3    2]  d=2 
[C3    5]  d=5 
[C3   10]  d=10 
[C3   20]  d=20 
[C3   50]  d=50 

Press  , go to next step 
C04 Maximum capacity 
 
  Page 15​
 of 27 
 
 
                                                 User Manual 
 
For example:max weighing 100kg: 
   set  [0100.00] 

Press  , go to next step 
C05 Zero calibration 
option:0=non­calibration zero      1=need calibration zero 
calibration zero  please  choose 1 and  ensure  scale  is empty and “stable” light 
is  on.  countdown[CAL  10]~[CAL  0],  then  the  indicator  will  
show[0.00](example for two decimal point). 
C06 Loading calibration 

  [C06],  Press  ,  show [C06  0],  press  ,  change to [C06  1], Press 

, show [SPAn  ],  
Basic  on  max  capacity setting, add suitable weight  on  scale. close to the max 
capacity,  heavier than 10% max at least. 
For example: the weight is 80kg 
As bellows: 
[0080.00] 
[CAL   9] 
…… 
[0080.00] 
[CALEnd] 
count down over, indicator shows loaded weight , loading calibration finish. 

If  you  want   to  set  application  parameter. Press    If  you  want to exit. 

Press  
C07  Default parameters setting  
[C07  0]  non­restore default parameters 
[C07  1]  restore default parameters 
Note:  after  the  above  parameters  setting  finish,  please  do  not  set  default 
parameters often, avoid the original setting parameters lost. 

 
  Page 16​
 of 27 
 
 
                                                 User Manual 
 

4.3 Application parameter setting

C08 warning tone 
[C8   1]   open warning tone 
[C8   0]   close warning tone 
C09 Power off automatically 
[C9   0]   Non­power off 
[C9  10]   keep still within 10 min. power off automatically 
[C9  30]   keep still within 30 min. power off automatically 
[C9  60]   keep still within 60 min. power off automatically 
C10 Power saving setting 
[C10  0]   close backlight 
[C10  1]   close backlight after 1 minute 
[C10  2]   always backlight 
C11 Hold 
[C11  0]   No Hold function 
[C11  1]   Peck hold 
[C11  2]   Data hold 
[C11  3]   Auto­hold 
[C11  4]   Animal weighing 
C12 Hold time​  ( if you choose C11=4, you can set the time ) 
[C12  3]   3 seconds 
[C12  5]   5 seconds 
C13 Upper limit alarm value 
C14 Low limit alarm value 
C15 Check inner code 

 
  Page 17​
 of 27 
 
 
                                                 User Manual 
 

4.4 Communication setting

C18 Serial interface setting 
[C18   0]   No sending 
[C18   1]   Big display  
[C18   2]   Print format output 
[C18   3]   Command mode(Z =zero  T=tare R=Reply weight 
[C18   4]   continuous sending 
C19 BAUD RATE 
[C19   0]   1200bit/s 
[C19   1]   2400bit/s 
[C19   2]   4800bit/s 
[C19   3]   9600bit/s 

4.5 Application setting

C20 Manually Zero  
[C20 00]   no Manually Zero 
[C20 01]   Manually Zero range ±1% Max. capacity 
[C20 02]   Manually Zero range ±2% Max. capacity  
[C20 04]   Manually Zero range ±4% Max. capacity 
[C20 10]   Manually Zero range ±10% Max. capacity 
[C20 20]   Manually Zero range ±20% Max. capacity 
[C20100]   Manually Zero range ±100% Max. capacity 
C21 Initially zero 
[C21  0]   No initially zero 
[C21  1]   Initially zero range±1% Max. capacity 
[C21  2]   Initially zero range±2% Max. capacity 

 
  Page 18​
 of 27 
 
 
                                                 User Manual 
 
[C21  5]   Initially zero range±5% Max. capacity 
[C21 10]   Initially zero range±10% Max. capacity 
[C21 20]   Initially zero range±20% Max. capacity 
C22 Zero tracking range 
[C22 0.0]   No zero tracking 
[C22 0.5]   ±0.5d 
[C22 1.0]   ±1.0d 
[C22 2.0]   ±2.0d 
[C22 3.0]   ±3.0d 
[C22 4.0]   ±4.0d 
[C22 5.0]   ±5.0d 
C23 Zero tracking time 
[C23  0]   No zero tracking 
[C23  1]   1 second 
[C23  2]   2 seconds 
[C23  3]   3 seconds 
C24 Overload range 
[C24 09]   Over 9d than max. capacity 
C25 Negative display 
[C25 00]   Less than ­9d 
[C25 10]   Less ­10% Max. capacity 
[C25 20]   Less ­20% Max. capacity 
[C25 50]   Less ­50% Max. capacity 
[C25100]   Less ­100% Max. capacity 
C26 Standstill time 
[C26  0]   Quick 
[C26  1]   Medium 
[C26  2]   Slow 
C27 Standstill range 
[C27  1]   ±1d 
[C27  2]   ±2d 
[C27  5]   ±5d 

 
  Page 19​
 of 27 
 
 
                                                 User Manual 
 
[C27 10]   ±10d 
C28 Dynamic filter 
[C28  0]   close dynamic filter 
[C28  1]   Low dynamic filter 
[C28  3]   Medium dynamic filter 
[C28  5]   High dynamic filter 
C29  Noisy filter 
[C29  0]   Close noisy filter 
[C29  1]   Low noisy filter 
[C29  2]   Medium filter 
[C29  3]   High filter 
 

4.6 Exit setting

For  example [C10 1],  Press  ,  confirm  it  then  press    to  exit  and 
save it  
 
 

 
  Page 20​
 of 27 
 
 
                                                 User Manual 
 

5.Output data format 

5.1Computer continuous sending format

     ,      ,                      CR  L

 
S 1      S 2     S 3       Data         ​ S 4 
  ​
   
S1:  weight status, ST= standstill, US= not standstill, OL= overload  
S2:  weight mode, GS=gross mode, NT=net mode 
S3:  weight of positive and negative, “+” or ” –“ 
S4:  measurement unit, “kg” or “lb” 
Data:  weight value, including decimal point 
CR:  carriage return 
LF:  line feed 

5.2 Big display continuous sending format

Output continuous format 

S  S  S  S  C 

T  W  W  W  X  X  X  X  X  X  X  X  X  X  X  X  K 

X  A  B  C  S 
1  2  3  4  5  6 

 
  Page 21​
 of 27 
 
 
                                                 User Manual 
 
 
State A 
Bits0,1,2 
0  1  2  Decimal point position 
1  0  0  XXXXXX0 
0  1  0  XXXXXXX 
1  1  0  XXXXX.X 
0  0  1  XXXX.XX 
1  0  1  XXX.XXX 
Bits3,4  Division  
0  1  X1 
1  0  X2 
 
State B 
BitsS  function 
Bits0  gross=0, net=1 
Bits1  symbol:positive =0,negative =1 
Bits2  overload(or lower zero)=1 
Bits3  dynamic=1 
Bits4  unit:lb=0, kg=1 
Bits5  Constant 1 
Bits6  Constant 0 
 
State C 
Bit2  Bit1  Bit0  unit 
0  0  0  Kg or lb 
0  0  1  g 
0  1  0  t 
Bit 3  printing=1 
Extend 
Bit 4 
display=1 
Bit 5  Constant 1 
Bit 6  Constant 0 

 
  Page 22​
 of 27 
 
 
                                                 User Manual 
 

5.3 Serial interface reception command:

    RS232COM serial interface can receive simple ASCII command.  
Command word and role as follows: 
Command  name  role 
T  Tare off command  Save and clear tare 
Z  Zero command  Zero the gross weight 
P  Print command  Print the weight 
R  Read  gross/  net   Read gross/net weight 
weight 
5.4Print output format

   NO.               004 (NO.) 
   G.W:            8.88kg  (gross,example for two decimal point) 
   T.W:            2.88kg (tare) 
   N.W:            6.00kg (net) 

5.5 Print the accumulated output format

NO.               004 (NO.) 
Total:       003  (accumulate times,example for 3 times is 003) 
Total.W:     2.88kg (accumulate weight) 
 

 
  Page 23​
 of 27 
 
 
                                                 User Manual 
 

6. Maintenance 

6.1 Regular Error and maintain method

Error   Reason instruction  Solution 


1.   the  loaded  weight  1.decrease loaded weight 
excess  overload  range of 2.   check  load  cell 
max. capacity   connection 
Display 
2.   wrong  connection  3.   checking  load  cell:
UUUUUU 
with  load  cell  or  no  check  input  and  output 
connection with it.  resistance to judge it is good 
3. load cell unworkable  or not. 
1. calibration is no good  1.   check  scale  is  resisted  or 
2、cell  single  line  is  not, foot is kept level or not. 
connect a wrong line.  2.   check  load  cell 
3、the cell is bad.  connection. 
Display nnnnnn 
3.   checking  load  cell:
check  input  and  output 
resistance to judge it is good 
or not. 
during   calibration,  no  Input the correct weight 
input  added  weight  or 
ERR1 
input  weight  exceed 
max capacity. 

 
  Page 24​
 of 27 
 
 
                                                 User Manual 
 
during   calibration,  the  Added  weight  at   least 
added  weights  not  10%of  Max.  capacity, 
enough  Recommend  the  weights  is 
ERR2 
60­80% the Max. capacity 

during   calibration, input  1..Check  connection  is  


single is negative.  correct or not. 
Check  load  cell  is  damaged 
ERR3 
or not. 
3.   renew  calibration,  if  still 
wrong. pls replace the PCB 
Ensure  added  weight  and 
During  calibration, 
ERR4  scale  is  stable,  start  
single is unstable 
calibration 

ERR5  EEPROM check error  change PCB. 

6.2​
Daily maintenance

  1.   In  order  to  ensure  indicator  display  clearly  and  prolong  use  life,  the 
indicator should not be placed directly on sunlight. 
  2.   Load  cell  and  indicator  should be  well  connected ,  the  system  should 
have a good ground, away from strong electric field, magnetic field. 
   3. Do not use indicator outside in rainy, better keep it power off. 
   4. Power off firstly while plug and unplug 

 
  Page 25​
 of 27 
 
 
                                                 User Manual 
 

6.3 Restore default parameters

Enter  setting  menu,  set  C07=  1,press  then  press   exit  saving 
setting, all parameters will be back to default setting. 
Note:Pls. do not restore default parameter easily if you are not professional 
and have not scale calibration. 
  
Default parameter form 
parameter  instruction  Default value 
C01  Calibration unit  1 
C02  decimal digits  0 
C03  Division value  1 
C04  Max capacity  10000 
C05  Empty scales calibration  0 
C06  Capacity calibration  0 
C07  restore the default parameters  0 
C08  Warning tone  1 
C09  Automatic power off  0 
C10  Power saving mode  0 
C11  Hold function  0 
C12  Animal weighing mode  0 
C13  Upper limit warning  000000 
C14  Lower limit warning  000000 
C15  Inner code display   

 
  Page 26​
 of 27 
 
 
                                                 User Manual 
 

C16  Date    
C17  Time   
C18  Serial interface data output methord  0 
C19  Serial interface Baud rate  3=9600 
C20  Manual zero setting  2 
C21  Initical zero setting  10 
C22  Automatic zero tracking range  0.5 
C23  Automatic zero tracking time  1 
C24  Verload range  9 
C25  Negative display range  10 
C26  Standstill time  1 
C27  Standstill range  2 
C28  Dynamic filter  0 
C29  Noisy filter  2 
C30~C40  Reseverd menu   
 

 
  Page 27​
 of 27 
 
 