PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
AEROCON PANEL PARTITION WALL
INSTALLATION MANUAL
Updated: Aug 2017 PageI1
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
INDEX
S.No Description Page No
1 Technical Data 03
2 Types of Panels 04
3 Product Usage 04
4 Tools & Accessories 05
5 Installation – Full Height Partition 07
6 Installation – Half Height Partition 18
7 Installation – Jumbo Height Partition 20
Installation – Jumbo Height Partition above 4.50 Mtrs
8 21
Height
9 Fire Separation wall 23
10 Connection Details 23
11 Painting 31
12 Handling & Storage 32
Updated: Aug 2017 PageI2
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
AEROCON PANEL WALL
Size (mm) Weight Unit Weight
(Thickness x Width x Length) (kg) – Each Panel (kg/m2)
50 x 600 x 2400 56.16 39.00
50 x 600 x 2700 63.18 39.00
50 x 600 x 3000 70.20 39.00
75 x 600 x 2400 77.76 54.00
75 x 600 x 2700 87.48 54.00
75 x 600 x 3000 97.20 54.00
AEROCON PANEL INSTALLATION
1. TECHNICAL DATA
Thickness
Properties Remarks
50 mm 75 mm
Weight (nom) per Sq.m. (Kgs) 39 54 Nominal weight
Factor of safety - 2.5
Axial load / meter width (KN/m) 53 83
(sample size: 1500 x 300 mm)
Bending test ( 4 point UDL ) Uniform distributed
load (Kg/m2 )
Factor of Safety - 2.5
2.9 m Span 66 95
1.5 m Span 198 265
Flexural Strength / Modulus of Rupture ( Kg/cm2 ) 67 58 Typical Test results
Thermal Conductivity ( W/m deg. K) 0.22 0.21 BS 4370 - Part 2
Sound Transmission Coefficient (db) 33 36 IS: 9901 (Part III) - 1981
(Typical Test Results of Prasar Bharati and NPL) IS: 11050 (Part I) - 1981
60 120 BS 476 Part 20 - 22
Fire rating ( minutes)* [As per test results of CBRI]
Updated: Aug 2017 PageI3
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
CLASS I BS 476 Part 7 - 1971
Surface spread of flame *
3.7 BS 476 Part 6 - 1981
Fire Propagation Index ( I ) *
CLASS ‘P’ BS 476 Part 5 - 1968
Ignitability * (not easy ignitable)
Standard Sizes :
Length 2400, 2700, 3000mm
Width 600mm
Remark : The above specifications are based on typial test results of Aerocon Panels with Flex-o-Board, and subkect to revision.
* As per test results of CBRI – ROORKEE , @ Could Vary due to change in moisture content.
2. TYPES OF PANELS : EDGE FINISH
Square Edge Panel Recess Edge Panel
3. PRODUCT USAGE
Application
1 hr. 2 hr.
S.No Description Thickness Type Fins /
Compound Fire Fire
Partition Prefab Mezzanine Cladding Vertical
Wall Rated Rated
Lovers
wall wall
Aerocon
1 50mm SE √ √ √ √ √ √ √ -
Panel
Aerocon
2 50mm RE √ √ - - - - √ -
Panel
Aerocon
3 75mm SE √ √ √ √ √ √ √ √
Panel
Aerocon
4 75mm RE √ √ - - - - √ √
Panel
Updated: Aug 2017 PageI4
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
4. TOOLS & ACCESSORIES
4.1 Measuring & Levelling Tools
Measuring Tape Levelling Plumb & Chord
4.2 Installation Accessories
Hitachi or Equivalent- Hitachi or Equivalent – Hitachi or Equivalent - Hitachi or Equivalent -
Rotary Drills Impact Drill Cutting Machine (C8) Grinder, Size 100mm.
2800 rpm,420 Watts 2900rpm, 450 Watts 5000 rpm,1400 Watts 11000rpm, 580 Watts
Wooden Plugs PVC Sleeves Wooden Screw Size 45 mm CSK Self-Drilling Screw
Size 45 mm.
Updated: Aug 2017 PageI5
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
4.3 Structural Frame
G.I Floor Channel G.I Ceiling Channel
4.4 Finishing & Painting Tools
( Panel Jointing System)
Aerocon Smart Plexus Aerocon Smart Putty / Aerocon SmartBond Panel Trowel 4”
Tape Acrylic Putty Jointing Compound
Sanding Machine / Sand
Finishing Trowel 8” Finishing Trowel Size 11”
Paper
Updated: Aug 2017 PageI6
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
5. INSTALLATION – FULL HEIGHT PARTITION
5.1 Aerocon Panel wall
Tools & Accessories
Aerocon Panel wall 50 / 75mm thk, G.I Floor Channel : 14 x (50/75) x 25 x 0.8/1mm thk
G.I Ceiling Channel : 38 x (50/75) x 38 x 0.8/1mm thk, Screw : Self-Drilling / Wooden screw Size 45mm.
Jointing Compound: Aerocon Smart Bond (Recommended)
Recess or square edge panels are
recommended for full height partitions.
Mark the floor plan as per approved drawing
Cut the floor channels as per required
lengths. Mark the ceiling with plumb to F.C.
and fix ceiling channels with self-expansion
screws.
Place & fasten the F.C. with self-expansion
screws at every 600mm centers on 50mm
face of channel.
The height needs to be checked for each
individual panel before inserting, follow the
same method for all panels.
Clean the floor channels, tongue and groove
portion of panels for firm fixing.
Lift & keep the 600mm side of panel parallel to
floor. Keep the groove side of panel towards wall
or column end.
Insert the panel by tilting it into ceiling channel
first and then position the same from 14mm side
of the Floor channel
Slowly push the panel into the Floor channel
with two heavy duty screw drivers without
damaging the corners as shown in picture.
Updated: Aug 2017 PageI7
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Position the panel & push towards wall. And
Check the right angle of panel.
If required insert plugs/packings in Floor
Channel to ensure right angle.
Position the second panel 550mm away from the
first panel and slowly drop slide towards first
panel. This technique enables fast & proper
joining of panels.
Updated: Aug 2017 PageI8
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Complete the partition by joining panel by panel
as per above procedure
Apply the Jointing material entire length of
tongue and groove as per below procedure and
insert the next panel, Push the panel to secure a
rattle free joint.
5.2 Aerocon Panel Jointing Procedure for RE (Reccess Edge Panels)
TOOLS:
For SmartGlu & Smartflex application : Use only Flexible Steel Knife
For leveling with wall-putty : Use Ordinary Putty knife
STEP-1: Applying Jointing compound on T&G
Product Used: SmartGlu (Water-miscible Powder)
PREPARATION OF SMARTGLU: Mix SmartGlu in 70%
water (or as required for desired workability) Make a
slurry.
METHOD: Application by Brush on Both Tongue &
Groove side & Immediately fix the Panels.
Updated: Aug 2017 PageI9
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
STEP-2: INFILL Step
Product Used: SmartGlu (Water-miscible Powder)
PREPARATION OF SMARTGLU: Mix SmartGlu in 35-40%
water (or as required for desired workability) to
prepare a non-flowing paste.
METHOD: Fill the paste tightly into the grooves, as well
as the recessed area, duly flashed with panel surfaces.
Infill Setting Interval before Next Step: 60 minutes.
NOTE:
Local TOUCH-UP - if any required: After setting, inspect
and wherever required fill up shrunk area if any, to
uniformly flash with panel surface.
Touch-up Setting Interval before Next Step: 30 minutes
STEP-3: RECESS TAPING (60mm)
Product Used: SmartFlex White Paste AND
SmartPoly 60-mm Tape
METHOD: Paste SmartPoly 60mm tape (over dried-up
SmartGlu) by using ready to use SmartFlex as an
adhesive paste.
Immediately carry on to overcoat tightly - just in order
to uniformly wetting the SmartPoly 60mm tape.
Consume no extra material.
Setting Interval before Next Step: 30 minutes, or till
touch dry.
NOTE: If the material feels tight, OR in very dry/hot
situations, may add 5-10 (five to ten)% external water -
if required.
Updated: Aug 2017 P a g e I 10
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
STEP-4: 2nd Layer Taping (16mm)
Product Used: SmartFlex White Paste AND
SmartPoly 16-mm Tape
METHOD: Paste & tightly wet SmartPoly 16mm tape
with SmartFlex as an adhesive paste (In very dry/hot
situations can add 5(five)% water if required).
Immediately carry on to overcoat tightly - just in order
to wet the SmartPoly 60mm tape uniformly. Remove
any extra deposition or spills.
Setting Interval before Next Step: Allow dry & shrink
for minimum 3 (three) hours – no upper limit of
interval.
STEP-5: Shrink Compensation Coat
Product Used: SmartFlex White Paste
Method: Apply a Tight coat of SmartFlex – Just enough
to re-wet the shrinkage, and no more - all along the
SmartPoly 16mm tape already fixed. Remove any extra
deposition or spills.
Setting Interval before Next Step: At least 2 hours, no
upper limit.
NOTE: At this stage Joints will look like about 0.5-1 (half
to one) mm thick lines - raised above the original panel
surface.
Updated: Aug 2017 P a g e I 11
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
STEP-6: FINAL FINISHING STEP = Seamless LEVELING:
(IT IS MOST IMPORTANT TO FOLLOW EXACTLY AS
EXPLAINED BELOW. DO NOT APPLY THICK WALL PUTTY
OVERCOAT LAYER AS PER CONVENTIONAL PRACTICE.
BECAUSE ANY THICKER THAN REQUIRED WALLPUTTY
WILL EVENTUALLY CRACK OVER THE RESILIENT JOINT).
Product Used: Ordinary White Cement based Wall-
putty typically 800gms/Sq
METHOD: Level out seamlessly using ordinary powder
wall-putty – carefully to the thickness of raised-up
Jointing line. Do not overbuild.
Putty Coats:
A) Ordinary leveling: 1 or 2 passes are fine.
B) Best Level-5 type finish: For such finest finish,
local touch-up coats are usually applied (usually
after 24 hours shrinkage time) on various parts
of Panel surface by skilled workmen. This is a
standard method for fine finishing like applied
for any construction - and not specific to Panels
or Joints.
Final Sanding with #300 grade fine sandpaper.
INSPECT & ENSURE: After final sanding Joints MUST be
seamlessly smooth & perfectly plain leveled. At the
same time a dark impression line MUST remain visible.
This impression after final sanding signifies correct
jointing & leveling.
NOTES:
- inadequate level filling over the panel surfaces out of
putty-shrinkage. This is normally supposed to be
inspected and taken care next day, before painting.
- conventionally, for fine finish (level-5 type), a 2nd &
sometimes even 3rd coat local finish with thin putty
coats are customary at the descretion of painter.
Similarly like paint makers, it is neither
possible, nor expected, from smartbond end to define
final finishing. It falls purely under the skillset of
concerned painter.
All skilled painters know above standard practices.
Updated: Aug 2017 P a g e I 12
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
JOINT PRIMING: When dry, directly apply 2 coats of
raw (i.e. undiluted) water-based primer - only along the
visible lines - at 1 hour interval to visually cover joint
mark. Use a soft hair 2” brush.
When fully dry, smoothen the brush/roller marks (if
any) with #320 sandpaper.
NB: Strictly no more putty application after this and
before painting.
Recommended Painting Procedure
Apply primer and paint on whole surface as per normal
good practices.
NOTES FOR PAINTER: The surface is already leveled; do
not apply any more Wall-Putty layer.
A GLOSSY PAINT IN ANY INSTALLATION - WHETHER
PANEL OR NOT - NEEDS FINER LEVELING AND SANDING
WITH #300 GRADE SANDPAPER FOR BEST FINISH.
(NOTE: Gloss brings out very minor undulations visible
even on block walls.)
Avoid any cement based thick rendering or texturing
because these are crack-prone non-resilient materials –
unfit for Panel/Board joints.
PANEL TO PANEL/WALL PARTITION CORNER JOINTS:
If joint gap is less than 2mm, fill with SMARTPOLY + SMARTFLEX. Use a corner knife or finger. If gap is 2-3mm, use
standard jointing method. In both cases lay tape in L shape with joint in the center. Level as described.
MANAGING TERMINAL GAP JOINT WITH CONCRETE, WOOD AND CONSTRUCTION STEEL MATERIALS:
Fill and finish terminal gaps up to 3mm wide with SMARTPOLY + SMARTFLEX. Use a corner knife or finger
If Terminal gap is between 4mm to 11mm wide, add equal qty of ordinary sand to SMARTGLU and fill. Finish
with 30-40mm wide SMARTPOLY tape (available on request) and SMARTFLEX compound
If Terminal gap is between 12mm to 25mm wide, further add 6mm downgraded stone chips and fill. Finish on
both side edges with 16mm wide SMARTPOLY tape and SMARTFLEX compound.
If the gap is more than 25mm wide, prepare 1:3:6 cement-sand-chip mortar duly adding 12% (by wt. of cement in mix)
SBR mortar and fill using masonry method. Hydration cure. After 3-4 days, apply SMARTPOLY + SMARTFLEX skin on both
side edges of the concrete fill. Finally finish with 0.5mm thick flashing wall-putty similarly like standard Joint Leveling
Updated: Aug 2017 P a g e I 13
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
DO’s
Prefer a Skilled Painter as Jointing & Finishing DON’Ts
applicator.
Do not apply any excess material.
Prefer/Recommend waterbase primer & emulsion
Do not overcoat wall-putty before painting
paint.
once finished.
While working in hot/dry conditions, if compounds
Do not use/recommend cementbased
become sticky for high evaporation, may periodically
render/texturing.
add minimum water to maintain desired workability.
Do not use oil/thinner to dilute compounds.
Keep periodically cleaning knife of dried comkpound
lumps. Do not use oil-based primer below water-based
paint, OR vice-versa.
If glossy paint is specified, leveling must be done with
best skills.
5.3 Aerocon Panel Jointing Procedure for SE (Square Edge Panels)
TOOLS:
For SmartGlu & Smartflex application: Use only Flexible Steel Knife
For leveling with wall-putty : Use Ordinary Putty knife
STEP-1: Applying Jointing compound on T&G
Product Used: SmartGlu (Water-miscible Powder)
PREPARATION OF SMARTGLU: Mix SmartGlu in 70%
water (or as required for desired workability) Make a
slurry.
METHOD: Application by Brush on Both Tongue &
Groove side & Immediately fix the Panels.
Updated: Aug 2017 P a g e I 14
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
STEP-2: INFILL Step
Product Used: SmartGlu (Water-miscible Powder)
PREPARATION OF SMARTGLU: Mix SmartGlu in 35-40%
water (or as required for desired workability) to
prepare a non-flowing paste.
METHOD: Fill the paste tightly into the groove, duly
flashed with panel surfaces.
Infill Setting Interval before Next Step: 60 minutes.
NOTE:
Local TOUCH-UP - if any required: After setting, inspect
and wherever required fill up shrunk area if any, to
uniformly flash with panel surface.
Touch-up Setting Interval before Next Step: 30
minutes
STEP-3: TAPING (16mm)
Product Used: SmartFlex White Paste AND
SmartPoly 16-mm Tape
METHOD: Paste SmartPoly 16mm tape (over dried-up
SmartGlu) by using ready to use SmartFlex as an
adhesive paste.
Immediately carry on to overcoat tightly - just in order
to uniformly wetting the SmartPoly 16 tape. Consume
no extra material.
Setting Interval before Next Step: 30 minutes, or till
touch dry.
NOTE: If the material feels tight, OR in very dry/hot
situations, may add 5-10 (five to ten)% external water -
if required.
STEP-4: Shrink Compensation Coat
Product Used: SmartFlex White Paste
Method: Apply a Tight coat of SmartFlex – Just enough
to re-wet the shrinkage, and no more - all along the
SmartPoly 16mm tape already fixed. Remove any extra
deposition or spills.
Updated: Aug 2017 P a g e I 15
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Setting Interval before Next Step: At least 2 hours, no
upper limit.
NOTE: At this stage Joints will look like about 0.5-1 (half
to one) mm thick lines - raised above the original panel
surface.
STEP-5: FINAL FINISHING STEP = Seamless
LEVELING:
(IT IS MOST IMPORTANT TO FOLLOW EXACTLY AS EXPLAINED
BELOW. DO NOT APPLY THICK WALL PUTTY OVERCOAT LAYER
AS PER CONVENTIONAL PRACTICE. BECAUSE ANY THICKER
THAN REQUIRED WALLPUTTY WILL EVENTUALLY CRACK OVER
THE RESILIENT JOINT).
Product Used: Ordinary White Cement based Wall-
putty typically 800gms/Sq
METHOD: Level out seamlessly using ordinary powder
wall-putty – carefully to the thickness of raised-up
Jointing line. Do not overbuild.
Putty Coats:
A) Ordinary leveling: 1 or 2 passes are fine.
B) Best Level-5 type finish: For such finest finish,
local touch-up coats are usually applied (usually
after 24 hours shrinkage time) on various parts
of Panel surface by skilled workmen. This is a
standard method for fine finishing like applied
for any construction - and not specific to Panels
or Joints.
Final Sanding with #300 grade fine sandpaper.
INSPECT & ENSURE: After final sanding Joints MUST be
seamlessly smooth & perfectly plain leveled, but a dark
color line MUST remain visible.
Updated: Aug 2017 P a g e I 16
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
INSPECT & ENSURE: After final sanding Joints MUST be
seamlessly smooth & perfectly plain leveled, but a dark
color line MUST remain visible.
NOTES: - inadequate level filling over the panel surfaces
out of putty-shrinkage. This is normally supposed to be
inspected and taken care next day, before painting.
- conventionally, for fine finish (level-5 type), a 2nd &
sometimes even 3rd coat local finish with thin putty
coats are customary at the descretion of painter.
Similarly like paint makers, it is neither
possible, nor expected, from smartbond end to define
final finishing. It falls purely under the skillset of
concerned painter.
All skilled painters know above standard practices
JOINT PRIMING: When dry, directly apply 2 coats of
raw (i.e. undiluted) water-based primer - only along the
visible lines - at 1 hour interval to visually cover joint
mark, When fully dry, smoothen brush/roller marks if
any with #320 sandpaper.
NB: Strictly no more putty application after this and
before painting.Recommended Painting Procedure
Apply primer and paint on whole surface as per normal
good practices.
NOTES FOR PAINTER:The surface is already leveled; do
not apply any more Wall-Putty layer.
A glossy paint in any installation - whether panel or not
- needs finer leveling and sanding with #300 grade
sandpaper for best finish. (note: gloss brings out very
minor undulations visible even on block walls.)
Avoid any cement based thick rendering or texturing
because these are crack-prone non-resilient materials –
unfit for Panel/Board joints.
PANEL TO PANEL/WALL PARTITION CORNER JOINTS:
If joint gap is less than 2mm, fill with SMARTPOLY + SMARTFLEX. Use a corner knife or finger. If gap is 2-3mm, use
standard jointing method. In both cases lay tape in L shape with joint in the center. Level as described.
Updated: Aug 2017 P a g e I 17
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
MANAGING TERMINAL GAP JOINT WITH CONCRETE, WOOD AND CONSTRUCTION STEEL MATERIALS:
Fill and finish terminal gaps up to 3mm wide with SMARTPOLY + SMARTFLEX. Use a corner knife or finger
If Terminal gap is between 4mm to 11mm wide, add equal qty of ordinary sand to SMARTGLU and fill. Finish
with 30-40mm wide SMARTPOLY tape (available on request) and SMARTFLEX compound
If Terminal gap is between 12mm to 25mm wide, further add 6mm downgraded stone chips and fill. Finish on
both side edges with 16mm wide SMARTPOLY tape and SMARTFLEX compound.
If the gap is more than 25mm wide, prepare 1:3:6 cement-sand-chip mortar duly adding 12% (by wt. of cement in mix)
SBR mortar and fill using masonry method. Hydration cure. After 3-4 days, apply SMARTPOLY + SMARTFLEX skin on both
side edges of the concrete fill. Finally finish with 0.5mm thick flashing wall-putty similarly like standard Joint Leveling
DO’s
Prefer a Skilled Painter as Jointing & Finishing DON’Ts
applicator.
Do not apply any excess material.
Prefer/Recommend waterbase primer & emulsion
paint. Do not overcoat wall-putty before painting
once finished.
While working in hot/dry conditions, if compounds
become sticky for high evaporation, may periodically Do not use/recommend cementbased
add minimum water to maintain desired workability. render/texturing.
Keep periodically cleaning knife of dried comkpound Do not use oil/thinner to dilute compounds.
lumps.
Do not use oil-based primer below water-based
If glossy paint is specified, leveling must be done with paint, OR vice-versa.
best skills.
6 INSTALLATION – HALF HEIGHT PARTITION
Tools & Accessories
Aerocon Panel wall 50 / 75mm thk., G.I Floor Channel : 14 x (50/75) x 25 x 0.8/1mm thk, G.I Ceiling Channel : 38 x
(50/75) x 38 x 0.8/1mm thk, Screw : Self-Drilling / Wooden Screw Size 45mm. Jointing Compound: Aerocon Smart Bond
(Recommended)
Updated: Aug 2017 P a g e I 18
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Aerocon panels are ideal for half height partitions as these
are single monolithic in nature and therefore offer
sturdiness.
Always end the partitions in ’L’ or ‘T’ shape of 300 to
600mm Panel width as shown in Picture
Start with existing brick wall, make a two drill at brick wall
and Aerocon panel at the distance of 300mm from top and
bottom side of the panel. And insert the steel rod. The Rod
need to be dipped before erection.
Floor channel can covered with skirting.
Updated: Aug 2017 P a g e I 19
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
The top end & free end walls must be covered by using
different materials like timber, medium density fiberboards,
PVC, Aluminum beading.
Complete the joint finish and paint as per above procedure.
7 INSTALLATION – JUMBO HEIGHT PARTITION UPTO 4.50 MTRS HEIGHT & 4.80 MTRS WIDTH
Tools & Accessories
Aerocon Panel wall 50 / 75mm thk.
G.I Floor Channel : 14 x (50/75) x 25 x 0.8/1mm thk , G.I Ceiling Channel : 38 x (50/75) x 38 x 0.8/1mm thk
Screw : Self-Drilling / Wooden Screw Size 45mm. Jointing Compound: Aerocon Smart Bond (Recommended)
Aerocon Panel partition work can be done without
Steel frame up to 4.50 mtr height & 4.80 mtr width.
Frame work is not required for these type of
partitions up to 4.5 mtrs.
Panels are staggered for strength & rigidity as
shown below.
Height of the panels is to be decided accordingly.
Top support, such as steel, concrete etc, is a must
for such type of partitions.
Fix the floor & ceiling channel as per laid
procedure.
Updated: Aug 2017 P a g e I 20
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
For horizontal joining first fix the full length panel
and apply Jointing material in the groove portion.
Place hexagonal PVC / WOODEN beading on top
groove of the 3 Mtr panel before placing the 1.5
Mtr panel and push the same into the ceiling
channel as per below fig.
Next, the 1.5 Mtr panel should come in lower side
and 3 Mtr panel in upper side & proceed in the
similar way. Complete the partition by fixing
panels one by one as per the above procedure.
Complete the joint finish and paint as per above
procedure.
8 INSTALLATION – JUMBO HEIGHT PARTITION ABOVE 4.50 MTRS HEIGHT
Frame work is required for above 4.50 Mtrs
height partitions such as MS Columns &
Beams as shown in picture
Updated: Aug 2017 P a g e I 21
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Horizontal MS Beam to be laid on 3mtr panel.
For concealing the steel sections need to
provide cement boards.
Complete the partition as per above
procedure.
Updated: Aug 2017 P a g e I 22
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
9 FIRE SEPARATION WALL
Due to its good fire-rating
properties, Aerocon panels are most
suitable for fire separation walls
where fire rating of two hours is
generally expected. Aerocon panels
come with a test backup from the
central building Research Institute,
Roorkee and has the following
unique properties
Recess or square edge panels are
recommended for Fire separation
partition walls
10 CONNECTION DETAILS AT AEROCON PANELS:
Section - BasePlate to Column Fixing Detail Plan - BasePlate Connection Detail
Updated: Aug 2017 P a g e I 23
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Section - Ceiling Fixing Detail Section - Ceiling Fixing Detail
Section – Panel Connection Detail at Tongue & Grrove Plan – Panel Connection at ‘L’ Joint
Plan – Panel Connection at ‘T’ Joint Plan – Panel Connection at Glass wall
Updated: Aug 2017 P a g e I 24
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Panel Connection at Gypsum wall Panel Connection with Tiles
Panel Connection at Brick wall Panel Connection at RCC wall
Updated: Aug 2017 P a g e I 25
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Panel Connection at Steel Column
Panel Connection with A.C
Updated: Aug 2017 P a g e I 26
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Panel Connection at Switch Board
Fins Application Detail
Updated: Aug 2017 P a g e I 27
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Door frame Detail (M.S – Mild Steel)
Door frame Detail (Wooden)
Updated: Aug 2017 P a g e I 28
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Door frame Detail (Alluminium)
Window frame Detail (M.S – Mild Steel)
Updated: Aug 2017 P a g e I 29
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Window frame Detail (Wooden)
Window frame Detail (Alluminium)
Updated: Aug 2017 P a g e I 30
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
11 PAINTING
Tools & Accessories
Primer Paint & Top Coat Paint,
Jointing Compound: Aerocon Smart Bond (Recommended), Brush, Roller, Etc.
Use Cement based putty, Leave for 2 hours,
Apply Coat again and leave to dry setting, Use
Sandpaper for smooth surface to finish clear
smooth.
Clear the dust from surface.
Use primer Paint to clear any scratches and
increase the life time of coating paint.
Leave to d
ry for one hour.
Updated: Aug 2017 P a g e I 31
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Paint top coat in 1-2 round , Leave to dry for 1-2
hours in each round
12 HANDLING & STORAGE
Place the support frames 2000 mm away from
each other and put the husk bags on their bases.
Lift and carry the panels vertically.
Updated: Aug 2017 P a g e I 32
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
Align the panel, allowing it to rest against the back
support, with the tongue side facing upwards.
Place three metal spacers for each panel – one at
the center and the other two on the sides (900
mm away from the center).
They can be stacked one after the other, as long as
the spacers are used.
Updated: Aug 2017 P a g e I 33
PRODUCT MANUAL: AEROCON PANEL PARTITION WALL
They can be stacked one after the other, as long as
the spacers are used.
When left in the open, the stack must be covered
with plastic/tarpaulin sheets.
Updated: Aug 2017 P a g e I 34