The document provides details of plumbing plans for a building including pipe diameters and slopes for drainage stacks, waste pipes, and vents from various floors above ground. Key details include a 150mm diameter galvanized iron swimming pool drain stack, 100mm diameter drainage stacks, 150mm diameter waste pipes sloped at 1%, and 75mm and 100mm diameter soil pipes also sloped at 1%.

Uploaded by

Emmanuel Tamayo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
122 views1 page

Male&Female PWD Layout-224 - 2f

The document provides details of plumbing plans for a building including pipe diameters and slopes for drainage stacks, waste pipes, and vents from various floors above ground. Key details include a 150mm diameter galvanized iron swimming pool drain stack, 100mm diameter drainage stacks, 150mm diameter waste pipes sloped at 1%, and 75mm and 100mm diameter soil pipes also sloped at 1%.

Uploaded by

Emmanuel Tamayo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

805

4 L)
527
161
239

1100mm x 500mm
IDENTIA

C16A
705

739
808
4

1067
150MMØ G.I. SWIMMING

1168
1369

1401
OFFICE) 200MMØ DS
POOL DRAIN STACK
M ABOVE) 69

M ABOVE) 100MMØ DS 409 1040

150MMØ WP(1%SLOPE)
150MMØ SP(1%SLOPE)

3101
MACHINE 100Ø SP(1%SLOPE) 450

OM ABOVE

F.F.L.
50Ø VPAC 71

L/RETAIL)

290
INSULATION 75Ø SP(1%SLOPE) 67

650mm x 1500mm
450

1100mm x 550mm
C14

C17
3521

±7.00
75MMØ VPAC F.F.L.

F F
AS PER LATEST ARCHITECTURAL PLAN
AS PER PLAN LAYOUT @SECOND FLOOR MALE/FEMALE & PWD TOILET CONFLICT TO BEAM @SECOND FLOOR
LEGEND :
- SOIL / SEWER PIPE

- WASTE PIPE

- STORM DRAIN PIPE

- PERFORATED PIPE

- VENT PIPE

- FCU DRAIN

- DISCHARGE PIPE

- BEAM

SUBCON CONTRACTOR: CONTRACTOR: MANAGEMENT: PROJECT OWNER: PROJECT TITLE: DRAWN BY DRAWN DATE REVISIONS SHEET CONTENTS: DRAWING NO.
SYM DESCRIPTION BY DATE
NBE 12-13-22 PHASE 2
CHECKED BY CHECKED DATE

THE CERISE TOWER


DESIGNED BY DESIGNED DATE
MALE / FEMALE & PWD TOILET LAYOUT @ SECOND FLOOR PMI-PL-SD-224
UNIT No. 9,EMPS COMMERCIAL BUILDING #254 AGUINALDO HIGHWAY PMI TOWER CABANILLAS CORNER, 273 PABLO OCAMPO SR. EXT., MALVEDA PROPERTIES &
ANDRES BALANAK BOLAñOS and Associate
,SAMPALOC 1,DASMARINAS, CAVITE, 4114 BRGY, LA PAZ MAKATI CITY 1203 PHILIPPINES
TEL. NOS. (02) 72180728 @ [email protected] TEL. NOS. (02) 7755-7195/8777-1764
DEVELOPMENT CORPORATION LOCATION: BLOCK 9, LOT 5, SOUTHWOOD CITY, BRGY. SAN FRANSICO
REVIEWED BY REVIEWED DATE

BINAN CITY, PROVINCE OF LAGUNA

You might also like