Cmd-V4 Service Manual Errors
Cmd-V4 Service Manual Errors
Controller OK -
No error -
FW version >=16.80:
Pull out the CMD-V4 or the VCMD
and then slide it back in again
(safety switch opened/closed) and
then wait for the subsequent
RESET.
If the status display reports '29'
once again after the start-up of the
CMD-V4 or VCMD, then the
shutter, the SAT or the controller
must be replaced.
Dirty photosensors/sensors
Error ERROR Explanation/action
code
Banknote measurement Check whether there is a jam in the
point (DDU) not ready area of the measurement station. Is
the measurement station dirty or are
the cables plugged in?
Replace dispensing unit with DDU
or controller.
Dispensing sensor dirty or A) If a cassette can be installed in
pressure sensor faulty cassette position 'x' without
X (x = 1 - 6) error (one-time signal tone),
then the error message
indicates an extremely soiled
photosensor 'dispensing sensor'
in the dispensing unit 'x' (PSDx)
that must be cleaned.
Afterwards, execute a reset
(move CMD-V4 or VCMD into
dispensing position).
Note:
After the first time this error has
occurred, the CMD-V4 or VCMD
can still continue working until the
operation is automatically shut
down with further increasing soiling.
Note:
After the first time this error has
occurred, the CMD-V4 or VCMD
can still continue working until the
operation is automatically shut
down with further increasing soiling.
Note:
After the first time this error has
occurred, the CMD-V4 or VCMD
can still continue working until the
operation is automatically shut
down with further increasing soiling.