MVI69-AFC and MVI69E-AFC Compare

The MVI69E-AFC flow computer supports more advanced features than the MVI69-AFC such as 12 meter runs instead of 8, IP-based communications including 4 IP addresses, separate alarm and event logs that can store up to 2000 each, and the ability to calculate or report indicated volume. It also supports newer gas measurement standards, protocols for transmitting archive data, and firmware updates for new features.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
89 views1 page

MVI69-AFC and MVI69E-AFC Compare

The MVI69E-AFC flow computer supports more advanced features than the MVI69-AFC such as 12 meter runs instead of 8, IP-based communications including 4 IP addresses, separate alarm and event logs that can store up to 2000 each, and the ability to calculate or report indicated volume. It also supports newer gas measurement standards, protocols for transmitting archive data, and firmware updates for new features.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

MVI69-AFC and MVI69E-AFC

MVI69-AFC MVI69E-AFC
Comparison
CompactLogix In-Chassis Flow Computer YES YES
Meter runs supported 8 12
Serial Modbus Communication Ports 3 2
Supports RS232 3 2
Supports RS422/RS485 2 2
Modbus TCP/IP Server Connections 0 8
Unique IP addresses supported 0 4
IP address whitelist NO YES
Debug/Configuration Serial Ports Only Serial or Ethernet
Latest AGA/API Calculations NO YES
GPA-2145 version 2003 2016
API MPMS 14.3 (AGA 3) 1992 2012 or 1992
API 21.1 1993 2013
Separate Event/Alarm Log NO YES
1999 (shared events
Max number of Events 2000 Events
and alarms)
1999 (shared events
Max number of Alarms 2000 Alarms
and alarms)
Max Archive Record Size 40 words 100 words
Modbus Transfer of Alarm/Events/Archive
YES YES
records
Enron Modbus & Modbus TCP/IP Transfer of
NO YES
Alarm, Events, and Archive records
Cygnet .DTF file for GMR and FMS Database NO YES
Support for Flow-Cal .CFX file download with
NO YES
EAFC Export Utility
Meter Proving support (meter factor) NO YES
Transmitter verification/calibration interface
NO YES
stored in Event record of module
End of day hour & end of hour minute Global - all meter runs Global or Individual per
configuration the same meter channel

Meter Run Calculation scan time 300 mSec 30 mSec

Ability to report Indicated or Gross Volume Gross Only Gross or Indicated

Additional Firmware updates for new features


and calculation standards to be released as they NO YES
become available
User entered or calculated heating value and Calculated by AGA8 or
Calculated by AGA8
relative density User Entered