0% found this document useful (0 votes)
126 views1 page

Cable Gland: Explosion Protection Dimensions

The document describes cable glands for use in hazardous environments. It provides information on the material, seals, colors, protection class, dimensions, certification, operating temperature, and ordering details for cable glands with Ex e or Ex i explosion protection that are suitable for zones 1, 2, 21, and 22. The cable glands allow for inserting cables into electrical equipment and conform to IP66/IP68 protection.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views1 page

Cable Gland: Explosion Protection Dimensions

The document describes cable glands for use in hazardous environments. It provides information on the material, seals, colors, protection class, dimensions, certification, operating temperature, and ordering details for cable glands with Ex e or Ex i explosion protection that are suitable for zones 1, 2, 21, and 22. The cable glands allow for inserting cables into electrical equipment and conform to IP66/IP68 protection.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Cable gland

• Zones 1/21 and 2/22 The cable gland made of polyamide is used for inserting permanent cables and
• IP66/IP68 leads into electrical equipment with the increased safety “e“ type of explosion
protection. The cable glands conform to the protection class IP 66/68. For
• Ex “e“ or Ex “i“ intrinsically safe circuits the cable entries are available with a blue cap nut.
When this cable gland is used, the instructions given in the type examination
certificate/operating instructions must be observed.

Explosion protection
Marking ATEX II 2G Ex e II C Dimensions
II 2D Ex tb IIIC Db IP 68
Certification PTB 13 ATEX 1015 X
Marking IECEx Ex e II C
Ex tb IIIC Db IP 68
Certification IECEx PTB 13.0034 X

L1
Operating temperature -40 °C to +75 °C

SW
L2
Technical data
Material Polyamid, self-extinguishing
Seals EPDM
Colour RAL 9005, black
RAL 5015, blue
Protection class IP 66/IP 68 EN/IEC 60529

Ordering information Cable gland Ex e, black


Thread size Cable range (Ø) Across flat (AF) Thread length (L2) Length in mm (L1) Unit Order no.
M12 x 1.5 3-6 16 15 35 - 45 50 03-6062-0137
M16 x 1.5 4.5 - 9 20 9 31 - 37 50 03-6062-0126
M20 x 1.5 7 - 13 24 10 36 - 45 50 03-6062-0127
M25 x 1.5 7 - 17 29 10 38 - 47 50 03-6062-0128
M25 x 1.5 10 - 17 29 10 38 - 47 50 03-6062-0136
M32 x 1.5 13 - 21 36 12 42 - 51 25 03-6062-0129
M40 x 1.5 17 - 28 46 12 52 - 65 10 03-6062-0130
M50 x 1.5 23 - 35 55 14 59 - 72 5 03-6062-0125
M63 x 1.5 31 - 48 68 15 64 - 78 1 03-6062-0131
Cable glands Ex e black, with long connection thread on request.

Ordering information Cable gland Ex i, with blue cap nut


Thread size Cable range (Ø) Across flat (AF) Thread length (L2) Length in mm (L1) Unit Order no.
M12 x 1.5 3-6 16 15 35 - 45 50 03-6065-0074
M16 x 1.5 4.5 - 9 20 9 31 - 37 50 03-6065-0066
M20 x 1.5 7 - 13 24 10 36 - 45 50 03-6065-0067
M25 x 1.5 7 - 17 29 10 38 - 47 50 03-6065-0068
M25 x 1.5 10 - 17 29 10 38 - 47 50 03-6065-0073
M32 x 1.5 13 - 21 36 12 42 - 51 25 03-6065-0069
M40 x 1.5 17 - 28 46 12 52 - 65 10 03-6065-0070
M50 x 1.5 23 - 35 55 14 59 - 72 5 03-6065-0071
M63 x 1.5 31 - 48 68 15 64 - 78 1 03-6065-0072
Technical data subject to change without notice.