0% found this document useful (0 votes)
73 views2 pages

KT Remote G PowerRemote en

The document describes two sets of inductive transmission systems from G-Power Remote Sensors. Each set consists of a transmitter and output sensor(s) that transmit signals over short distances. The RGPT 3005/RGPE 3005 system transmits over 2-5 mm and supports up to 5 sensors. The RGPT 4008/RGPE 4008 system transmits over 3-8 mm and supports up to 8 sensors. Both systems operate at 24V DC and transmit signals inductively.

Uploaded by

Todi Findra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
73 views2 pages

KT Remote G PowerRemote en

The document describes two sets of inductive transmission systems from G-Power Remote Sensors. Each set consists of a transmitter and output sensor(s) that transmit signals over short distances. The RGPT 3005/RGPE 3005 system transmits over 2-5 mm and supports up to 5 sensors. The RGPT 4008/RGPE 4008 system transmits over 3-8 mm and supports up to 8 sensors. Both systems operate at 24V DC and transmit signals inductively.

Uploaded by

Todi Findra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Inductive G-Power Remote Sensors

Transmission Transmitter/Output sensor


Systems for max. 8 sensors
Housing size M30x1.5 M30x1.5 40×75×40 mm 40×75×40 mm
Type Transmitter Í•••••••Î Output sensor Transmitter Í•••••••Î Output sensor
Transmission distance 5 mm 8 mm
Installation type non-flush non-flush non-flush non-flush

Transmitter RGPT 3005-V1215-PU-05 RGPT 4008-V1220_-PU-05*


Output sensor PNP RGPE 3005-V1215P-PU-05 RGPE 4008-V1220P_-PU-05*

Assured transmission distance 2...5 mm 3...8 mm


Supply voltage UB incl. ripple 24 V DC ±10 % 24 V DC ±10 %
Voltage drop Ud at Ie ≤ 1.5 V ≤ 1.5 V
Rated operational current Ie ≤ 50 mA per output ≤ 50 mA per output
No-load supply current I0 max. ≤ 400 mA ≤ 500 mA
Off-state current Ir ≤ 80 µA ≤ 80 µA
Short circuit protected yes yes
Tightening torque 40 Nm 40 Nm

Radial offset ± 3 mm ± 3 mm
Operating current (for sensors) ≤ 150 mA ≤ 200 mA
Output voltage (for sensors) 12 ±1.5 V DC 12 ±1.5 V DC
Rated insulation voltage Ui 75 V DC 75 V DC

Ambient temperature range Ta 0...+50 °C 0...+50 °C 0...+50 °C 0...+50 °C


Switching frequency f 60 Hz 60 Hz
Function/Supply voltage indicator yes/no yes/yes

Degree of protection per IEC 60529 IP 67 IP 67 IP 67 IP 67

Housing material Nickel plated brass Nickel plated brass Al Al


Material of sensing face ABS/PBT ABS/PBT ABS/PBT ABS/PBT
Connection type 5 m PUR cable 5 m PUR cable 5 m PUR cable 5 m PUR cable
No. of wires × cross-section 9×0.18 mm2 + 2×0.5 mm2 9×0.18 mm2 + 2×0.5 mm2 9×0.18 mm2 + 2×0.5 mm2 9×0.18 mm2 + 2×0.5 mm2
for max. 8 sensors
For your electrical planning,
please ask for the user’s guide!
*For type RGPT4008/RGPE 4008
select between version A or B
Version A: Sensing face in front
Version B: Sensing face on side
Ordering example: RGPE 4008-V1220PA-PU-05

18
Inductive G-Power Remote Sensors
Transmission Transmitter/Output sensor
Systems for max. 8 sensors
90×90×45 mm 90×90×45 mm
Transmitter Í••••••••••••••••Î Output sensor
12 mm
non-flush non-flush

RGPT 9012-V2430-PU-05
RGPE 9012-V2430P-PU-05

4...12 mm
24 V DC ±10 %
≤ 1.5 V
≤ 50 mA per output
≤ 800 mA
≤ 80 µA
yes

± 6 mm
≤ 300 mA
24 ±1.5 V DC
75 V DC

0...+50 °C 0...+50 °C
60 Hz
yes/yes

IP 67 IP 67

Al Al
ABS/PBT ABS/PBT
5 m PUR cable 5 m PUR cable
9×0.18 mm2 + 2×0.5 mm2 9×0.18 mm2 + 2×0.5 mm2
for max. 8 sensors

www.balluff.com 19