This document contains configuration information for an ECU including software version numbers, communication protocols, memory addresses, parameter values and ranges. It defines 4 areas of memory with start and end addresses and read/write protection values. Baud rates are specified for diagnostic connections to the ECU.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views2 pages

APCIMSW

This document contains configuration information for an ECU including software version numbers, communication protocols, memory addresses, parameter values and ranges. It defines 4 areas of memory with start and end addresses and read/write protection values. Baud rates are specified for diagnostic connections to the ECU.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 2

[GeneralInfo]

Version = 1.00
MID = 128
MSW_PN = 21779651
ECU_PN = 20977019
MSW_MaxMessageLength = 21
MSW_DiagnosticConnectorProgrammable = 1
ByteOrder = 1
VSPID =
ECU_SN =
Old_DST_PN =
New_DST_PN = 21023876
CommunicationType = ENGSAE
Old_FormulaName =
New_FormulaName =
Level1DllName =
Level2DllName =
Level3DllName =
Old_ConstantFile =
New_ConstantFile =
[Level0]
DL_MaxMessageLength = 128
FlashSyncErase = True
FLASHReprogramPW = 5879
FLASHEraseDelay = 10000
FLASHChecksumCalculationDelay = 5000
FLASHPartialErase = true
[Level1]
EEPROMMasterPW = 5487
[ParameterProgramming]
Paramid1 = 9D,ATJ,ATK,ATL,ATM
Address1 = 5398,288C,2896,28A0,28AA
Size1 = 2,9,9,9,9
Data1 =
047E,354636364C45384D56,424B4D345057305848,334B36453743314C42,39504E354D4539574B
ParameterType1 = N,S,S,S,S
MinValue1 = 300,0,0,0,0
MaxValue1 = 1400,0,0,0,0
ScaleFactor1 = 0.100000,1.000000,1.000000,1.000000,1.000000
DataType1 = 4,1,1,1,1
ParameterLevel1 = 3,3,3,3,3
Unit1 = km/h,N/A,N/A,N/A,N/A
Paramid2 = ATN,ATO,BUR,BUS,DP
Address2 = 28B4,28BE,4B64,4B66,539C
Size2 = 9,9,2,2,2
Data2 = 5A5A4E443441305756,464B4C434E5938574B,06E0,09B0,03E8
ParameterType2 = S,S,N,N,N
MinValue2 = 0,0,800,800,300
MaxValue2 = 0,0,3200,3200,1400
ScaleFactor2 = 1.000000,1.000000,0.062500,0.062500,0.100000
DataType2 = 1,1,4,4,4
ParameterLevel2 = 3,3,2,2,4
Unit2 = N/A,N/A,mm,mm,km/h
Paramid3 = DR,DV,DVD,DY,DZ
Address3 = 1875,539E,2A44,1799,1798
Size3 = 17,2,1,220,1
Data3 =
4420202020313330323130202020202020,012C,44,3231303239323832303030323130393937353430
30303231303834343237303030323037363337383230303032303931303039313030303230373633373
23530303032313138373234393030302020202020202020202020202020202020202020202020202020
20202020202020202020202020202020202020202020202020202020202020202020202020202020202
02020202020202020202020202020202020202020202020202020202020202020202020202020202020
20202020202020202020202020202020202020202020202020202020202020202020,07
ParameterType3 = S,N,N,S,N
MinValue3 = 0,300,0,0,0
MaxValue3 = 0,1350,255,0,20
ScaleFactor3 = 1.000000,0.100000,0.050000,1.000000,1.000000
DataType3 = 1,4,1,1,1
ParameterLevel3 = 2,4,2,2,2
Unit3 = N/A,km/h,N/A,N/A,N/A
Paramid4 = GVX,IUD,JBP
Address4 = 57FA,212C,2118
Size4 = 2,16,4
Data4 = 0000,32313032383230302020202020202020,00000002
ParameterType4 = N,S,N
MinValue4 = 0,0,0
MaxValue4 = 0,0,2
ScaleFactor4 = 1.000000,1.000000,1.000000
DataType4 = 3,1,6
ParameterLevel4 = 2,2,2
Unit4 = N/A,N/A,N/A
[AreaInfoLevel1]
AreaId = 1,2
AreaStartAddress = 0000,0400
AreaEndAddress = 03FF,FFFF
AreaRWPWAddress = 000C,000E
[AreaInfoParameterProgramming]
AreaId = 1,2
AreaStartAddress = 0000,0400
AreaEndAddress = 03FF,FFFF
AreaRPW = FFFF,FFFF
AreaRWPW = FFFF,FFFF
[BaudRates]
DSW = 9600
MSW = 115200
DST = 9600

You might also like