Data Pack
Order information
Customer Name EAST COAST
Customer PO number 19228
Wolong order number 1000028633
Revision number 0
Last revised date 14th June 2022
Status Release for production
TAG # -
CONTENTS
Page no
1 DATASHEET 3
2 RUNNING PERFORMANCE 4
3 STARTING CHARACTERISTICS 5
4 OUTLINE DRAWING 6
5 MAIN TERMINAL BOX & CONNECTION DRAWING 7
6 TERMINAL BOX FOR RTD & CONNECTION DRAWING 8
7 HEATER TERMINAL BOX & CONNECTION DRAWING 9
8 TESTING, CERTIFICATION & REVISION HISTORY 10
DATASHEET
Motor Nameplate
MODEL 5KS584EAM221 FRAME 5812 SN TBA
RATED POWER 2000 HP EFFICIENCY (%) 94.7 LRA (%) 650 CODE G
RPM 1772 SERVICE FACTOR 1.00 DE BEARING ABMA 130BC02J3
AMP. 442/ 255 INSULATION CLASS F LUBRICATION GREASE
VOLTS 2300/ 4000 POWER FACTOR 0.89 LUBRICANT MOBIL POLYREX EM
PHASE 3 HERTZ 60 ODE BEARING ABMA 130BC02J3
TIME RATING CONTINUOUS AMB.TEMP(°C) LUBRICATION GREASE
MAX ALTITUDE 3300 ft MAX. 40 MIN. - 20 LUBRICANT MOBIL POLYREX EM
TEMP.RISE CLASS F RISE @ 1.0 SF OIL PRESSURE ---
TYPE KS ENCLOSURE WP-II IP 24W OIL FLOW ---
ROTATION - DUAL WEIGHT 11500 LBS
SUITABLE FOR - CLASS I DIV 2 GRP BCD (SELF DECLARED) - T3 @ 1.0 SF
Motor Application information
Max. kVAR 330 Vibration 0.12 in/sec
Driven Load NOT AVAILABLE Motor Noise (pressure level) 90 dBA at 3.3 ft
Coupling type DIRECT Mounting HORIZONTAL
2 2
Rotor inertia 680 Lb-ft Load inertia (Max) - Lb-ft
Information for motor protection
X / R RATIO 15.03 Stator resistance @ 25 Deg C 0.1322 Ω (L - L)
Open Circuit time constant 0.79 sec
Accessories offered
RTD TYPE PT-100 SINGLE QTY 2 PER PHASE
STATOR RTD o o
ALARM 150 C TRIP 155 C
RTD TYPE PT-100 DUAL QTY 1 PER BEARING
BEARING RTD o o
ALARM 90 C TRIP 100 C
HEATER FRAME (LOW SHEATH) POWER 110 W VOLTAGE 1-PH 120/240 V
Foundation Loads
FOUNDATION LOADS IN lb
ROTATION SHORT CIRCUIT CONDITION MAX TORQUE CONDITION
FACING ODE F1 F2 F1 F2
CW 37479 -25979 13684 -2184
CCW -25979 37479 -2184 13684
Customer approval signature
Approved date
RUNNING PERFORMANCE
Running performance w.r.t. Load
0.0170
95.0
0.0150
90.0
85.0 0.0130
80.0 0.0110
Powerfactor
Efficiency
Slip (pu)
75.0 0.0090
70.0
0.0070
65.0
0.0050
60.0
55.0 0.0030
Efficiency Vs Load Power factor Vs Load Slip Vs Load
50.0 0.0010
0.00 20.00 40.00 60.00 80.00 100.00 120.00
Load (%)
Calculated Performance at 4000 V
Load(%) P.F (PU) Eff( %) Curr. (A) Slip (PU)
No Load - - 62 -
115 - - - -
100 0.89 94.7 256 0.015
75 0.88 95.3 193 0.011
50 0.84 95.5 134 0.008
Winding connection Y
Temperature Class at 1.0 S.F Class F
Temperature Class at 1.15 S.F NA
Customer approval signature
Approved date
STARTING CHARACTERISTICS
Motor starting performance
2.2 7.0
2.0
6.0
1.8
1.6 5.0
Torque / PF in PU
1.4
Current in PU
4.0
Axis Title
1.2
1.0
3.0
0.8
0.6 2.0
0.4
1.0
0.2
0.0 0.0
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00
Speed in PU
Torque @ 1 PU Voltage Torque @ 0.9 PU Voltage Current @ 1 PU Voltage Current @ 0.9 PU Voltage
Motor Starting information @ 1PU
Starting torque (% of FLT) 100 Min starting voltage in PU 0.9
Pull Up torque (% of FLT) 100 COLD 2
No of Starts at 1 PU Voltage
Breadown Torque (% of FLT) 200 HOT 1
Starting current (% of FLA) 650 COLD 20
Locked Rotor time in seconds
Rated Torque - Lb-Ft 5924 HOT 15
Stator / Rotor slots 60 / 50
ROTOR CONSTRUCTION - Fabricated Copper Alloy (Brass) Rotor
Customer approval signature
Approved date
0 1 2 3
A A
B B
C C
D D
E E
© COPYRIGHT 2018 Wolong Electric America LLC AND/OR ITS AFFILIATES.
All rights reserved.
GE CLASSIFICATION CLASS II (GE INTERNAL TECHNICAL PUBLICATION)
CUSTOMER ----
CUST ORDER No ----
--- ---- ---- . CUST DWG No ----
--- ---- ---- .
ORIGINAL SHEET SIZE = A4
PROJECT ORDER No ----
--- ---- ---- .
REV DESCRIPTION NAME DATE FUNCTION REF ---- LOCATION REF ----
REVISION HISTORY EQUIPMENT REF ---- LANGUAGE EN
DRG TITLE
SHEET
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES MAIN CONDUIT BOX 1
F OF 1 F
DRG EXPORT TAG: LICENSE NOT REQUIRED
NEMA II
THIRD ANGLE PROJECTION DRG TYPE: MECHANICAL DESIGN -
MECHANICAL PART
---- DRG
UNLESS OTHERWISE INITIAL REV
DRAWN BY: NANDA SOURCE
INDICATED BY ARROWS DRG No.
DRAWN DATE: 01/24/2022
DO NOT MEASURE
OFF THIS DRAWING APPROVED BY: JOSHI IN MM82C100182 000
APPROVED DATE: 01/24/2022
0 1 2 3
0 1 2 3
A A
B B
C C
D D
E E
© COPYRIGHT 2018 Wolong Electric America LLC AND/OR ITS AFFILIATES.
All rights reserved.
GE CLASSIFICATION CLASS II (GE INTERNAL TECHNICAL PUBLICATION)
CUSTOMER ----
CUST ORDER No ----
--- ---- ---- . CUST DWG No ----
--- ---- ---- .
ORIGINAL SHEET SIZE = A4
PROJECT ORDER No ----
--- ---- ---- MM/DD/YYYY
REV DESCRIPTION NAME DATE FUNCTION REF ---- LOCATION REF ----
REVISION HISTORY EQUIPMENT REF ---- LANGUAGE EN
DRG TITLE
SHEET
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES ACCESSORIES BOX 1
F OF 1 F
DRG EXPORT TAG: LICENSE NOT REQUIRED
RTD(SINGLE) - BTD(DUAL)
THIRD ANGLE PROJECTION DRG TYPE: MECHANICAL DESIGN -
MECHANICAL PART
---- DRG
UNLESS OTHERWISE INITIAL REV
DRAWN BY: NANDA SOURCE
INDICATED BY ARROWS DRG No.
DRAWN DATE: 04/07/2019
DO NOT MEASURE
OFF THIS DRAWING APPROVED BY: JOSHI IN MM82C100068 000
APPROVED DATE: 04/07/2019
0 1 2 3
0 1 2 3
A A
B B
C C
D D
E E
© COPYRIGHT 2018 Wolong Electric America LLC AND/OR ITS AFFILIATES.
All rights reserved.
GE CLASSIFICATION CLASS II (GE INTERNAL TECHNICAL PUBLICATION)
CUSTOMER ----
CUST ORDER No ----
--- ---- ---- . CUST DWG No ----
--- ---- ---- .
ORIGINAL SHEET SIZE = A4
PROJECT ORDER No ----
--- ---- ---- MM/DD/YYYY
REV DESCRIPTION NAME DATE FUNCTION REF ---- LOCATION REF ----
REVISION HISTORY EQUIPMENT REF ---- LANGUAGE EN
DRG TITLE
SHEET
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES HEATER BOX 1
F OF 1 F
DRG EXPORT TAG: LICENSE NOT REQUIRED
Class I, Division 2, T3
THIRD ANGLE PROJECTION DRG TYPE: MECHANICAL DESIGN -
MECHANICAL PART
---- DRG
UNLESS OTHERWISE INITIAL REV
DRAWN BY: NANDA SOURCE
INDICATED BY ARROWS DRG No.
DRAWN DATE: 04/09/2020
DO NOT MEASURE
OFF THIS DRAWING APPROVED BY: SANDIPAN IN MM82C100069 000
APPROVED DATE: 04/09/2020
0 1 2 3
Testing & Certification
Motor built as per NEMA MG-1 & Tested as per IEEE 112
Routine tests performed on the machine
AC HIGH-POTENTIAL
PHASE SEQUENCE
NO-LOAD LOSSES
INSULATION RESISTANCE
NO-LOAD CURRENT EACH PHASE
NO-LOAD SPEED
WINDING RESISTANCE
MECHANICAL VIBRATION
ADDITIONAL ACCESSORIES
- Opposite drive end bearing bracket insulated
- Provision for Differential Pressure Switch
- Paint: Standard 2-Part Epoxy Finish, standard color Motor Blue (Munsell 8.3B 3.54/1.9)
- Stainless Steel Filters, Stainless Steel Screens, 1/4 in. mesh
- 300 Series Stainless Steel Hardware
- Main Terminal Box - NEMA Type-II, NEMA 4X Painted
- Air filters shall be checked / cleaned to maintain the motor temp rise below class F, beyond which-
filters to be removed.
REVISION HISTORY
Rev. No. Description Revised by Date
0 Initial release Nanda 14th June 2022
Customer approval signature
Approved date