ZJ70DBS Drilling Rig Electrical Drive and Control System User Manual
ZJ70DBS Drilling Rig Electrical Drive and Control System User Manual
User Manual
i
User Manual of ZJ70DBS Electrical Drive and Control System
Preface
ii
User Manual of ZJ70DBS Electrical Drive and Control System
Contents
ii
User Manual of ZJ70DBS Electrical Drive and Control System
3.1 Supply dynamic power, lighting power and controlling power ..................... 18
3.2 24VDC power supply operation................................................................... 19
3.3 power on individual unit orderly in VFD house ............................................ 20
3.4 check the rotation direction of blower inside the converter cabinet ............. 21
3.5 MCC house start-up and operation ............................................................. 21
3.6 startup and operation of driller’s cabin ........................................................ 22
3.7 check the running of motor blower and lube pump...................................... 22
4. Operation in Driller’s cabin .................................................................................. 23
4.1 Function and Operation of Apparatus on Driller’s Chair .............................. 23
4.2 Pressurization explosion-proof operation of driller’s cabin错误!未定义书签。
Chapter 3 Daily Service and Fault Treatment ............................................................ 25
1. Precautions ........................................................................................................ 25
2. Precautions of Hoisting, Transportation and Reinstallation ................................ 26
2.1 Hoisting and Transportation: ....................................................................... 26
2.2 Reinstallation:.............................................................................................. 26
3. Daily Maintenance and Storage .......................................................................... 27
3.1 Daily Maintenance....................................................................................... 27
3.2 Regular Inspection ...................................................................................... 29
3.3 Storage ........................................................................................................ 32
3.4 Maintenance ............................................................................................... 32
4. Trouble Shootings .............................................................................................. 33
iii
User Manual of ZJ70DBS Electrical Drive and Control System
The electrical system (hereinafter referred to as system) of ZJ70DBS rig mainly consists
of main diesel generator set, auxiliary diesel generator set, VFD/MCC house, driller’s
cabin, drawworks(DW) AC&VF motor(s), mud pump (MP) AC&VF motor(s), rotary table
(RT) AC&VF motor(s), auxiliary drive AC&VF motor, combined hydraulic pressure
unit(HPU), sensors, and pneumatic & hydraulic components.
The system is classified into three parts: power supply, power distribution and control.
Power is supplied from diesel generator set and provided for drilling operation.
Power distribution includes variable-frequency drive part and low-voltage distribution part.
The VF drive part is configured with cabinet-type rectifier unit, cabinet-type inverter unit
and braking chopper unit; and power supplied by DC bus bar. Low-voltage distribution
loops are mainly used with Schneider frame-type circuit breakers, molded case circuit
breakers, contactors, thermo-relays and squirrel-cage motors.
1
User Manual of ZJ70DBS Electrical Drive and Control System
Control part is applied with Siemens S7-300 series PLC; with features of modulization,
non-fan, easy to arrange and powerful CPU, it’s suitable for oilfield environment. By
using PROFIBUS technology, CPU can fulfill high-speed and reliable transmission with
each station in PROFIBUS network. Siemens M377 touch screen applied with our
self-developed software provides a simple and easy operation to driller; real-time status
and parameter displaying on screen provide necessary information to driller for drilling
condition judgment, fault tracing and equipment maintenance. Meanwhile, this part has
the functions of Mis-operation protection and equipment self-test to prevent important
equipment from damage.
2
User Manual of ZJ70DBS Electrical Drive and Control System
3
User Manual of ZJ70DBS Electrical Drive and Control System
◆ PLC cabinet
Function: as one of the logic control center of electrical drive system, it is
equipped with ET200 module, relevant I/O module, terminal block, diode PCB
and relays etc.
Electrical control cabinet
Function: Fitted with switch power supply, circuit breaker, SITOP power supply,
contactor, relay, terminal block etc., to supply control power to driller’s cabin.
Touch screen, DW speed joystick and disc brake handle
Function: via operating joystick, handle, touch screen and buttons, can realize
drilling control and operation; meanwhile, the drilling parameters will real-time
monitored by touch screen.
Video system
Function: To monitor the whole wellsite in multiple channels & angles; and adjust
pan/tilt to zoom in/out images.
Pressurization Ex-proof unit
The Electrical control cabinet, PLC cabinet, Driller chair arm are adopted with
pressurization explosion-proof which to meet explosion-proof requirements in
zone 2.
2. Generator System
2.1 System Introduction
The system is comprised of generator control cabinets, for supplying 600V/50 Hz AC
5
User Manual of ZJ70DBS Electrical Drive and Control System
2.2.1 Overview
Generator cabinets are used for generator sets paralleling operation, monitor and safety
protection.
6
User Manual of ZJ70DBS Electrical Drive and Control System
and tachometer head are formed to speed control system, into stabilize
diesel engine speed and generator frequency.
Excitation control unit
Basler DECS-100 digital excitation control system is based on 16bit
high-performance microprocessor, designed to protect for
over-excitation/under-excitation, and control generator output voltage.
Meanwhile, it offers communication with PC for parameter upload and
download.
Synchronizing unit
Woodward SPM-D11 is a synchronizing unit with integrated control functions
for power control and load sharing. Through the application of appropriate
logic to the discrete inputs, the following functions can be realized:
• Synchronization
• Synch-check
• Load/var sharing
• Over/under-voltage, over/under-frequency alarm signal output
Electric instrument
It is used to measure phase voltage, line voltage, current, active power,
reactive power, apparent power, power factor and frequency, etc., based on
electromagnet shield theory and MCU; and via RS-485 interface
communicate digital with PLC.
2
User Manual of ZJ70DBS Electrical Drive and Control System
3.1.1 Rectifier Control Cabinet
The cabinet is mainly equipped with main circuit breaker and control section.
z The main circuit breaker is adopted with Schneider MT frame type, which has
protect function for short circuit and overload, into make sure the rectifier
section normal running.
z The control section is taken S7-200PLC as logic control center, which
combined with analog modules to supply real-time monitoring to protect
rectifier system against fusing, overvoltage, over-current, over-temperature
and phase-lack, etc.
3.1.2 Power Unit Cabinet
This cabinet is fitted with input reactor and rectifier.
z The input reactor is used to inhibit the harmonic generated from non-linear
load, and then reduce the effect on upstream circuit and prevent excess
voltage and surge current impacting on drive system due to mis-operation.
z Rectifier module is the type of three-phase and Diode Bridge; and each
module is fitted with wheels for easy move and maintenance.
The braking hoppers are connected via optical fibers and one as master and others
as slavers. Once the voltage on DC bus exceeding 1127V is detected, the main
chopper will be put into operation and others will be activated.
Rema
Configuration Description Items Property
rks
Mode DP
Motor qty. 3
Power 1200KW
Travel switch
Adapter FIBER
Accessories
Motor qty. 2
Power 1000KW
Blower 15KW
Lube pressure
CONFIGURED WITH
Drawworks switch
Drive inverter
Air pressure
CONFIGURED WITH
switch
Travel switch
Adapter FIBER
Accessories
Motor qty. 1
Power 600KW
RT rated torque
Lube pump 7.5KW
Rotary
Blower 15KW
table
Lube pressure
CONFIGURED WITH
switch
Air pressure
CONFIGURED WITH
switch
5
User Manual of ZJ70DBS Electrical Drive and Control System
Adapter
Accessories
Motor qty. 1
Drive mode
Control mode
Top drive Control interface
Software
Adapter
Accessories
Qty. 1
Accessories
Auxiliary Qty.
Controls
EM brake
Adapter
Accessories
Qty 2
Driller’s
Communication
cabin ET200
module
Qty
MCC Communication
module
Slave station Derrick Qty
lifting Communication
up/lowering module
Qty
Mud pump
Communication
console
module
Top drive Qty
6
User Manual of ZJ70DBS Electrical Drive and Control System
switchover Communication
module
Signal Communication
WB1850
collection Generator module
slave station Collection
module
Qty. 1
computer Qty.
Toolpusher
Language
office IPC
Function
Qty. 2
Model 6AV6644-0AB01-2AX0
HMI HMI
Communication
DP
mode
5. Equipment Specification
5.1 Main Motor Specification
RT AC&VF Motor
QTY 1
Type
Rated Speed 661r/min
Rated Power 600kW
Rated Voltage: 600V
Rated Current 714A
Power Factor 0.86
Rated Efficiency 95%
Insulation class 200
DW AC&VF Motor
QTY 2
Type
Rated Speed 800r/min
Rated Power 1000kW
Rated Voltage: 600V
Rated Current 1215A
Power Factor 0.87
Rated Efficiency 95%
Insulation class 200
QTY 3
8
User Manual of ZJ70DBS Electrical Drive and Control System
Type
Rated Speed 1000r/min
Rated Power 1200kW
Rated Voltage: 600V
Rated Current 1449A
Power Factor 0.88
Rated Efficiency 95%
Insulation class 200
QTY 1
Type 50Hz
Rated Speed
Rated Power 1480r/min
Rated Voltage: 45kW
Rated Current 400V
Power Factor 75A
Rated Efficiency 0.85
Protection degree IP56
9
User Manual of ZJ70DBS Electrical Drive and Control System
Capacity 1250kVA
Input/output 600V/400V
Cooling natural air cooling
QTY 1
Type BYTF-45FG
Rated Power 4.5kW
Input voltage 220V
Frequency 50Hz
Structure window type, Single-cool
10
User Manual of ZJ70DBS Electrical Drive and Control System
Safety Notice
General
For users’ safety, prior to any operation, read through the safety notice carefully, or else,
there could be equipment damage (see converter, motor or other driving equipment) or
personal injury even death.
The utilization of caution and warning
The manual includes two kinds of safety notice: caution and warning.
Warning is to remind the users of adapting correct precautions to get free of accident
which could cause equipment damages or personal injury even death.
Caution is to remind the user of the special event/ situation, or instruction about a certain
subject.
Warning remarks:
or equipment damages!
Static Release Warning: the static relase which probably lead to equipment
damages!
11
User Manual of ZJ70DBS Electrical Drive and Control System
inverter.
Electric equipment installation and maintenance
These warning are mainly for these persons who operate converters, motor
cables or motors. Ignorance of these regulations could cause physical injury even
death.
Only the certified electric engineer can be authorized to install or maintain
the driving unit.
z It is forbidden to install or maintain the driving unit, motor cables or motors with power
on. Wait for at least 5 minutes after power off till the intermediate circuit capacitance
has been released thoroughly. Then use multi-meter with impedance at least 1 MΩ
12
User Manual of ZJ70DBS Electrical Drive and Control System
to test the voltage between the terminal UDC+ and UDC-, for ensuring that the
discharging of driving unit has finished.
z Never allowed to operate the controlling cables with the driving unit or external
controlling circuit power on. Although the main power has been cut off, there might be
hazardous voltage inside from the external circuit.
z All insulation tests can only be carried out with the cables disconnected.
z Make sure of correct phase sequence when re-connecting the cables.
Caution:
z Nevertheless the motor is running or not, there will generate hazardous high voltage
once the input power is connected.
z There is hazardous high DC voltage at these braking controlling terminals (UDC+,
UDC-, R+, R-), generally over 500V.
z When relay output terminals RO-RO3 is connected to power supply 115V or 220V
(230V), there will generate hazardous voltage.
z With the power off, the blower of rectifier cabinet, converter cabinet and braking
cabinet will still run for a while, and some parts, such as the radiator of power
semiconductor will also stay at high temperature for a while too. Hence just pay
attention to safety.
z The control power of rectifier cabinet, converting cabinet and brake cabinet as well as
power supply of blower are all from outside. After the main breaker on the cabinet is
disconnected, there will still have voltage in the control part of the cabinet. Please
refer to the circuit drawing to check the circuits still with voltage. Overall, just make
sure that the cabinet has no electricity by measurement.
z Before inserting and pulling out the plug of outlet cabinet, make sure that the plug &
receptacle have no electricity.
Warning:
Some electronic components on the printing circuit board are sensitive to static
13
User Manual of ZJ70DBS Electrical Drive and Control System
discharge. Therefore it is advisable to wear the earth wrist strap during operation. Don't
touch the circuit board at will.
1. Preparation of Electrification
Check the connection of dynamic loop to ensure there is no short circuit, connection
failure or disconnection on motor cables and primary / secondary of transformer as well
as circuit breaker inlet/outlet. Additionally, ensure that there is no clearance of lug
connection.
Test insulation of bus in VFD/MCC house, motor cables, primary and secondary of
transformer, inlet and outlet of main breaker, as well as ground connection.
a. Use 500V magneto-ohmmeter to test consumers below 500V and the tested insulation
value should at least be 2MΩ. Get it recorded.
b. use 1000V magneto-ohmmeter to test consumers from 500V to 1000V and the tested
insulation value should at least be 2MΩ. Get it recorded.
14
User Manual of ZJ70DBS Electrical Drive and Control System
Check transformer connection to ensure that neutral phase of transformer has been
grounded, and 3-phase-1-ground, 2-phase-1-ground or 1-phase-1-ground is strictly
forbidden, namely, it is forbidden to use earth as neutral cable. Beside, Ensure that
electrical potential between house and cabinets, cable tray and substructure, derrick and
substructure, tank and house, motor shell and motor base is even, and all ground
connection is reliable. Pay attention to the following factors:
c. Cross section of ground stake bronze bar ≥35 mm2 and at least 1.5m must be buried
beneath the ground surface.
Inspect it for misconnection by using Multi-meter and ensure that there is no short circuit
or misconnection for cables at different voltage, especially for low-voltage connection
between AC600V and DC24V, and connection between DC24V and AC220V, otherwise,
there could be electrical apparatus damages or personnel injury even death.
Inspect peripheral environment. Ensure that each terminals of cable are connected
correctly, and the cable is aligned orderly in right cable tray. Remove irrelevant cables
from the field.
In addition, keep the houses clean and ensure indoor temperature and humidity fit for
equipment operation. Check the connection of screws and wires in the cabinets and
ensure no foreign materials inside. Before electrification, ensure all load switches are in
“off “status. Close all the cabinet doors and other doors with dangerous voltage. Connect
to control power first, and then carry out further operation and control.
15
User Manual of ZJ70DBS Electrical Drive and Control System
2. Generator start/stop
Air-conditioners are mounted in the VFD house and Driller’s cabin to keep indoor
temperature around +27℃.
Placed at an altitude within 1000m, the equipment can reach the rated output. If the
altitude exceeds 1000m, the output current will decrease with the correction coefficient
as 8% reduction per 1000m increment.
There should not be excessive acid, alkali and salt, as well corrosive or explosive gases
in surroundings.
With the ambient temperature stable at 20℃, the relative humidity should not be over
90%.
Breakers setting
Rated Short
Ics
name current current type In A Ir tr Isd tsd Ii
kA
A kA
Q1~Q4 1650 31.89 MT20N2 2000 50 0.9 1 3 Off0.1 8
It is a cooperation work between electrician and diesel mechanic. First, the mechanics
check oil, gas, water and each relevant part according to the specification of diesel
engine and then electrician conducts checkup according to the following rules:
16
User Manual of ZJ70DBS Electrical Drive and Control System
3) Test the resistance of GEN. controlling cable and the resistance to ground by using
multi-meter (the signal line cannot be grounded). Actuator resistance: around 30 ohm;
speed sensor resistance: Around 90 ohms; exciting wiring resistance is up to the wiring
connection: around 12 ohms if serial-connected; around 4 ohm if parallel connected (test
F+, F-).
4) Make sure that the programs DECS100, S7-200 and SPM-D11 have been down
loaded (Generally, the program is down-loaded before rig delivery, yet it is needed to pay
attention during module replacement.
a. RATED SPEED: turn the rated rpm potentiometer to minimum position (turn
anti-clockwise to the end)
e. LOW IDLE SPEED: turn to the maximum (turn clockwise to the end)
f. ACTUATOR COMENSATION: turn to “2” within the range from 0~10 for diesel, steam
turbine or oil-charge turbine.
g. START FUEL LIMIT: turn to the maximum (turn to the end clockwise)
2.2.2 Startup
With the preparation ready, the diesel mechanic and electrician operate as the following
procedures.
1) First turn the generator mode switch to “IDLE”; second the diesel mechanic opens the
compressed air valve and press start button. Then the diesel engine speeds up to idle
17
User Manual of ZJ70DBS Electrical Drive and Control System
speed automatically.
2) After the diesel engine idles for a while, the electrician turns the “running mode switch”
to “rated” position and then the diesel engine speeds up to rated value.
3) Turn the “running mode switch” to the “run” position and then the generator starts
generating electricity, with “running” indicator illuminated; the voltage reading should be
around 600V and the frequency should be around 50HZ.
4) Turn the generator mode switch to “load” position; with bus power off, the breaker
engages on directly; with bus power on, the breaker engages on automatically after the
generator has been confirmed synchronizing. The GEN. set will get soft loading
automatically till the balance achievement between the active power and reactive power.
There is normal stop and emergency stop. The latter is taken as forced method for
emergent situation with all power supplies cut off, while the former is carried out by the
following steps:
A. Turn the generator switch to run”, and then the generator will reduce load
automatically. When the load is reduced to 5~10% of the rated value, the main
breaker switches off automatically to get the unit off line.
D. After running for a certain period under idle mode, turn the “running mode switch to
“stop”.
18
User Manual of ZJ70DBS Electrical Drive and Control System
Note: main GEN. and AUX. GEN. cannot supply the system with dynamic power at the
same time as their corresponding breakers have been interlocked,
z Main generator power supplying: after the generator cabinet outputs AC600V power,
the red power indicator of transformer T1 inlet breaker on switch cabinet door gets
illuminated. For the first time, it’s needed to store the energy manually. After there
appears the remark which indicates the energy storage has been finished, press the
engage-on button, and then the green indicator gets illuminated too, indicating that
primary and secondary of power transformer T1 has been powered on; as for
supplying dynamic power to the system, just engage on the outlet breaker of T1 as
the above steps.
z AUX. generator power supplying: start AUX. GEN and engage on its inlet breaker to
supply dynamic power to the system.
Switch on their power breaker manually, and then the inlet terminals of individual
controlling circuit and lighting circuit get electrified.
Use specific key to open the cabinet. It’s forbidden to make the cabinet withstand
human weight.
2) Press start-up button of UPS to supply lighting device and small-power equipment
with continuous power when UPS stops audio alarming.
1) Switch on the controlling circuit and the power indicator (white) gets illuminated. At
this time, PLC system starts working;
3) Press SB1 to start rectifier cabinet. With the yellow indicator shining, the rectifier
starts pre-charging automatically and the output DC voltage steps up;
4) With conditions fulfilled, the main breaker switches on automatically and the running
indicators (green) shine.
5) After 1 second, the breaker switch-on circuit powers off, and another one second later,
the pre-charging circuit automatically switches off, followed by indicator darkening.
Note: with the pre-charging period finished, the main breaker still does not close, and
20
User Manual of ZJ70DBS Electrical Drive and Control System
2S later the pre-charging circuit switches off automatically, meanwhile the relay
resets. In this situation, inspect the breaker for any damages, perhaps it is fault about
relay engaging-on operation.
7) Check whether rotation direction of blower inside the inverter cabinet is in conformity
with the arrow on the enclosure. If not, switch the blower off power and change any
two phases into each other in the three-phase power cable.
3.4 check the rotation direction of blower inside the converter cabinet
Only when DC bus was electrified, can cooling fan of inverter module starts running.
Therefore, on the condition that DC bus bar is not electrified, it’s suggested to check the
rotary direction of these blowers (blower in brake cabinet and the blower of brake
resistors) first. When the blower in brake cabinet is working, the cooling air blows upward;
when two resistor blowers are running, they both rotate at the same direction, with the
wind blowing to resistor.
With respect to rotary direction of the blowers in inverter cabinet, they can be
checked respectively after rectifier units are electrified, and the wind direction should
accord with arrow on the blower shell.
MCC feed circuit and motor control circuit installed at drawer-pattern cabinet is
comprised of breakers, contactors, thermo-relay, button and indicator etc, in
convenience for service and operation. Each cabinet is configured with grounding
protector; each control unit protected by fuse can achieve service-lock function and can
be disconnected from main circuit at the same time.
When corresponding bus bar has been electrified in MCC house, red indicator on MCC
drawer will shine, which indicates inlet terminal of drawer is at electrified status and the
21
User Manual of ZJ70DBS Electrical Drive and Control System
drawer can be switched on. After switching breaker on, the green running light shines,
which means this drawer has been powered on.
Some of the drawers which adopt voltage-loss protection will trip off automatically when
voltage-loss occurs. Before next switch-on operation, it is needed to switch off the
relevant breaker and reset the tripped drawer. Then, further switch-on can be carried out.
There should be no excessive acid, alkali and salt, corrosive gases and explosive
gases in the surrounding
Before MCC bus is electrified, switch off MCC drawer breaker to get free of overload.
With any mistake in start-up period, there might be equipment damages or personnel
injury even death.
Driller’s cabin is the control center of the whole drilling system. The breaker for “driller’s
cabin power supply” must be switched on at first.
Press green “switch-on” button to close contactor in power control cabinet automatically.
Then driller’s cabin is connected to the main power.
The electric control cabinet mainly supplies control power to driller’s cabin. First open the
cabinet, second manually close corresponding breakers and start UPS at the same time,
and then 220VAC(120V)AC/24VDC/24VAC/12VDC control power supplies in driller’s
cabin are all switched on, and PLC indicator shines, followed by HMI starting up slowly.
First make sure that breakers or drawers for cooling blowers of mud pump, RT, and
cooling oil pumps of DW gearbox, MP as well as the liner wash pump have been
switched on. Second manually turn “test” button to “test” position (the button is to start
22
User Manual of ZJ70DBS Electrical Drive and Control System
the intermediate relay which control the above circuit). At this moment, the
corresponding motors start running, and indicator on the intermediate relay coil used for
receiving the corresponding air pressure signal and operation signal of the blower shines.
If the motor does not run or if the motor runs without the indicator shining or the lockout
button activates without intermediate relay coil indicator shinning, troubleshoot it at once.
Turn the two CPUs in the PLC cabinet to “RUN” position, and supply power to IPC on the
cabinet door and to all inverter units at the same time. Switch on the power breaker in
lighting cabinet and power on slave station module ET200 and two touch screens
MP377. At this time, there is one workable communication channel between driller’s
cabin and PLC cabinet. Refer to the following description for the normal status detail:
1). There should be no red indicator shining on ET200M and CPU as well as their
selected channel and module, while the other green status indicators are shining.
2). Three status indicators of NPBA-12 in the PLC cabinet should be all green;
3). The data displayed on the touch screen on synthetic cabinet door in VFD house and
that on MP377 touch screen is zero or shown by a concrete values, not shown as “###”.
With the above three items fulfilled, the communication is proved to be normal.
Otherwise, troubleshoot the soonest possible to ensure correct communication.
When set or operate some important electrical apparatuses, such as rectifier unit,
inverting modules, some controlling modules in generator cabinets, PLC module, air
conditioner, and video system etc., just refer to the relevant document.
The driller’s chair is configured with buttons for system E-stop, drive E-stop, DW joystick,
23
User Manual of ZJ70DBS Electrical Drive and Control System
brake joystick, E-brake and park-brake. The system E-stop button is used to stop all the
generator units under emergency. When press this button, the whole system will be cut
off power supply. The drive E-stop button is used to switch drive section off power supply,
namely, directly disconnect inlet terminals of the two rectifier units, and in this way the
DW, RT, and mud pumps cannot be actuated.
Channel switchover function: when the network is faulty or the communication is not
normal, switch to the other backup network.
DW joystick adjusts the speed of the DW motor A or B to realize the hoisting, lowering
and suspending of the whole movable system. The joystick can perform self-reset and
self-zero lock function. At free mode, it is automatically locked at middle position (zero).
Operation method: hold the joystick with the left hand and press the lock button, and
then the joystick can be moved upward or backward. When the joystick is off the zero
position, the operator gets free of it and then it automatically returns to the zero and gets
locked.
At zero position, the joystick sends a zero-speed signal to DW. At this time, if the DW
motor is running, the traveling block will stay at suspending mode.
When the joystick gets to other position by being pulled forward or pushed backward, the
DW motors will rotate clockwise or anticlockwise so as to control the travelling system
moving upward or downward at the required speed. During the period, with the joystick
to the limit position, it will send maximum speed signal to rotate the DW motors and then
traveling system can be hoisted and lowered at maximum speed.
Note:
1) Make sure that all doors of electrical control cabinets are closed; before opening the
cabinet and console, ensure all power has been turned off.
2) Keep surface clean and dry. It’s forbidden to store debris inside.
3) It’s required to check and clean regularly; avoid any collisions.
4) Only the professionals are authorized to inspect or maintain.
24
User Manual of ZJ70DBS Electrical Drive and Control System
1. Precautions
1) Firstly, ask a special person to be responsible for the whole electric-control system;
only the personnel with corresponding qualification certificate can get access to VFD
house; all the operations must conform to the corresponding regulations.
2) The air conditioner in VFD house should be in the automatic operation status all the
time; keep indoor temperature about +25℃, and indoor humidity generally not beyond
85%; keep the house clean, and no smoking indoor. When the indoor humidity exceeds
85%, adopt proper measures immediately; otherwise, it may cause damage to some
equipment.
3). When the system is running, do not open or close the door frequently; otherwise, the
heat which comes from outside forms into condensate because of the low temperature
indoor, as a result equipment could be damaged.
4). It’s forbidden to switch off the conversion cabinets during running period.
5) Don’t operate channel switching too frequently; otherwise there would be damages on
the relevant equipment. Channel switching can only be performed when necessary, and
prior to operation, halt all equipment through the touch screen (switch-on/off not
necessary).
6). In order to avoid the danger from residual voltage, it’s only allowed to open the
cabinet for inspection till 5-minute discharging after it shuts down. Before handling
sensitive electrical apparatus, operator must discharge static of his own.
7) The blowers of drawworks motors, mud pump motors and liner wash pump, cooling oil
pump are interlocked. Therefore, when the motors are enabled, their blowers will work;
when the DW is enabled, the cooling oil pump will work too. Make sure that the signal
indicator on the MCC drawer is correct, or else, the motor cannot be started up. Usually,
25
User Manual of ZJ70DBS Electrical Drive and Control System
turn the switches on drawers to “on” position, and select “auto” control mode. For
maintenance, please switch off power supply circuit.
8). Do Not open the cabinet door with system running, otherwise, it could result to
influence upon the cooling-air circulation and to personnel injury or even death because
of high voltage inside and personnel carelessness in operation.
9). As for the drawers with HOA (Hand-Off-Auto) control, the contactor inside will be
directly closed with the knob turned to “H” position for power on after the breaker
engages on. Therefore, when start a motor by using the HOA control, make sure there is
no persons close to the motors and all the cables are connected correctly and reliably.
1) Before hoisting, look over the position and type of hoisting stake and hole.
2) Choose proper tool and method accordingly.
3) Crane numbers must be taken into account according to house weight and crane
capacity.
4) Structure and thickness of rope must be adequate for hoisting.
5) Choose appropriate vehicle according to the weight and length of the house.
6) be aware of the height limitation; use rope or strap to fix the house onto the vehicle to
avoid movement of the house during transporting.
7) While being transported, all the doors (for house and cabinet) must be locked well to
avoid any damage
2.2 Reinstallation:
1) Protect the cables while unloading from being damaged by hard or sharp materials
etc.
2) As the cable is transported with the cable tray, it should be coiled in the cable tray
26
User Manual of ZJ70DBS Electrical Drive and Control System
6) When the equipments arrives at the installation site, check whether the equipment is
damped or damaged.
7) When plugs and cables are being reinstalled, ensure them de-energized and
conductivity and insulation should also be inspected, which should be firmly installed
according to the tag name.
9) Open the cabinet for ventilation when necessary, for example, the blower door of
generator house, both sides’ doors of braking resistor.
The electric equipment should be checked and maintained regularly to ensure the
normal operation of the system and prolong the service life.
28
User Manual of ZJ70DBS Electrical Drive and Control System
When a regular check is required, first shutdown system and cut off the power, second
open the cabinets for checkup. However the inspection on rectifier cabinets and
29
User Manual of ZJ70DBS Electrical Drive and Control System
converter cabinet can only be carried out at least 5 minutes later after power off because
they are still with dangerous voltage.
1) Ambience
Ensure that the ambient environment is favorable.
Check the temperature, humidity, vibration and air (whether there is dust, gas, oil mist,
dew, etc) by instrument.
Confirm there is foreign object or hazardous material around by visual check.
2) Control Circuit
Check whether the control circuit is connected firmly; inspect the terminal connections
for looseness, burnt smells, discolored, cracks, distortion and rust.
3) Cooling system
Inspect the cooling fan for abnormal noise, abnormal vibration and bolts looseness, as
well as overheat discoloration; check if there is any block stuff or foreign material in vent
and radiator.
4) Main Loops
z Bus bar: inspect bolts for looseness, and insulation for distortion, cracks, damages or
discoloration due to overheating as well as dust.
z Conductors and cables: inspect conductor for discoloration and deformation; inspect
the cover for damages, cracks or discoloration.
z Check whether the terminal supports are broken.
z Inspect the filter capacitors for leakage, discoloration, cracks or shell swelled; check
whether the valves are obviously swelled. Measure the static capacitance as
required by static capacitance instrument.
z Inspect the resistance for strange smell because of overheating; inspect the
insulators for cracks or disconnection.
z Inspect the contactor and relays for vibration sounds or cold solder joint.
z Refer to the operation instructions of motors to checkup and maintain the motors.
5) MCC Drawer
z Inspect the component and wire grooves for dust and contaminants.
30
User Manual of ZJ70DBS Electrical Drive and Control System
z Check connection between the main bus bar and vertical bus bar and tighten when
needed; Check and tighten the other terminal connections too.
z Inspect the wires for insulation damaged or bad connections. Pull out the plug &
receptacle assembly to check the installation.
z As the breakers are switched off/on frequently, especially after short-circuit, the
contact terminal is easily burned out and covered with carbon stuff which increases
contact resistance. Just maintain and lockout as per the breaker manual.
6) Main Transformer
Abnormal Possible Cause Eliminating
Phenomenon
Dirty windings harsh environment Blow with dry air or clean with a duster or cloth.
and bad Don’t scratch the wire insulation or use solvent
maintenance like gasoline, etc.
Windings Partial overheat or solve with manufacturer
cracking, natural ageing
discoloration
Winding Produce abnormal Find out the reason and take
flashover with voltage or be measurement.
carbon tracking affected by
abnormal voltage
Rustiness of Aging of antirust Repair with specified coating as air-tight and
iron core materials, harmful water-proof treatment to reduce the indoor
gas, rain, or humidity.
condensation.
Discoloration of Overload. Loose Reduce the load and tighten the bolts, polish
outlet bolts or poor contact and galvanize the contact surface
connections surfaces
due to overheat
31
User Manual of ZJ70DBS Electrical Drive and Control System
3.3 Storage
1) The VFD house and driller’s cabin usually used outdoor can be stored outside for a
short time, generally at temperature ranging from -2℃ to +55℃, with equipment
performance in good condition.
2). If the equipment will not be used for long (e.g.: half one year), they should be stored
indoors. Do not expose them to the sun and rain; inspect the equipment regularly for
humidity, condensate and mould; with any phenomena as above, dehumidify with heater
and fan.
3) No matter long-term or short time storage, make sure of clean environment and clean
it with dust collector periodically.
3.4 Maintenance
1) The bolt-fixed part could be loosened due to vibration and the terminals will lose
conductivity, so the bolt must be checked regularly.
2) Cables must be checked often since vibration may produce friction between the
insulation layer and other components; as a result, there will be electric accident.
3) Dust is easily to absorb moisture. With too much dust accumulated on the bus bars,
there will result to creepage between the bus bar and the support members (ground
connection); with too much dust accumulated between pins of connector, there will
result in false signal connection; with too much dust accumulated on radiator in the
cabinet, there will be influence upon the effect of heat emission, and finally lead to
damages on electric and electronic apparatus. Therefore, cleaning work must be
carried out regularly.
4) Generally protective circuit doesn’t work; it only works when there is accident.
Hence, check it regularly to ensure of normal status.
5). AC motors, as rotary equipment, is one of the key equipments of electric drive
system, hence there is a mass of maintenance work.
First check and clean the air filter of the motor regularly to prevent dust from blocking
the air circulation, so as to get free of overheating. It is recommended that the
32
User Manual of ZJ70DBS Electrical Drive and Control System
motor should be checked after 500 running hours. Refer to the relevant
maintenance guide provided by motor manufacturer for further maintenance.
Based on above instruction, maintenance procedure can be carried out as follow:
Daily Check of Crew Shift:
(1) Whether that switch and indicator works normal or not
(2) Whether the fuses are in good condition.
(3) Whether the blowers and the air conditioner are running properly
(4) Whether generator load distribution is even.
Monthly Check:
(1) Whether the bolts of all terminals are loose.
(2) Whether cables are broken.
(3) Whether protective electrical apparatus is in a good condition.
(4) Whether there is anything abnormal on the connections.
(5) Whether the relays work normally.
(6) Remove the dust from the cabinet.
Carry on thorough checkup carefully every year with power off. Inspect bolts for
looseness; check protection circuit, relays and transformer. Lubricate rotating parts;
replace lighting fixture; remove dust in the house, etc. Refer to operation
instructions of generator and motor for detailed procedures.
4. Trouble Shootings
When the rectification and inversion units are faulty,please refer to User Manual for
detailed resolutions. If the problems can’t be solved, please directly contact the local
ABB technical support. Common malfunctions and treatments are as follows:
HT rectifier cabinet
Inverter Faults
34
User Manual of ZJ70DBS Electrical Drive and Control System
35
User Manual of ZJ70DBS Electrical Drive and Control System
36
User Manual of ZJ70DBS Electrical Drive and Control System
Non-parallel inverter
R10…R12i trip level
setting too sensitive.
Check parameter 30.25.
ENCODER A<>B Pulse encoder 1 phase Exchange phase A and phase B
Fault code: sequence error: phase A connection of the pulse encoder.
7302 is connected to phase B
terminal or vice versa.
ENCODER ERR Speed measurement 1 Inspect settings of parameter group 50.
Fault code: fault. Possible causes
7301 are loose connection of Inspect pulse encoder and the
cables, communication connection of phase A and B of it. When
over-time or too much motor rotates, parameter 1.03 SPEED
difference between the MEASURED 1 and internal actual signal
internal speed and the 1.02 MOTOR SPEED must be the
actually measured same. If different, exchange connection
speed. of phase A and B of the pulse encoder.
37
User Manual of ZJ70DBS Electrical Drive and Control System
38
User Manual of ZJ70DBS Electrical Drive and Control System
OVERCURRENT Over current. If the drive unit trips during the fast start
Fault code: process check if the parameter 21.01
2310 START FUNCTION has been set as
AUTO. (The other modes do not support
Fast Start).
39
User Manual of ZJ70DBS Electrical Drive and Control System
40
User Manual of ZJ70DBS Electrical Drive and Control System
41
User Manual of ZJ70DBS Electrical Drive and Control System
MASTER is red,
MSG is red and Contact local ABB service
DDCS flashes representative
Status indicator ROM detection failure Reset module
MASTER
flashes, MSG is Contact local ABB service
red, DDCS is red representative
42
User Manual of ZJ70DBS Electrical Drive and Control System
and flashes
Note: Only common faults of inverter are listed as above. If any other fault occurs, refer
to “ABB firmware manual, system software 7.x”
43
User Manual of ZJ70DBS Electrical Drive and Control System
44
User Manual of ZJ70DBS Electrical Drive and Control System
45
User Manual of ZJ70DBS Electrical Drive and Control System
46
User Manual of ZJ70DBS Electrical Drive and Control System
47
User Manual of ZJ70DBS Electrical Drive and Control System