100% found this document useful (2 votes)
2K views6 pages

Slab Design Eurocode

1) The document provides specifications and calculations for the design of a two-way reinforced concrete slab with a span of 7000mm x 4000mm that is part of an office building. 2) The minimum required slab thickness is calculated to be 150mm based on deflection limits. 3) Reinforcement requirements are calculated for bending moments in the short and long spans of the slab. Top and bottom reinforcement of H10 bars are specified with areas ranging from 0 to 375mm2/m depending on the location within the slab.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
2K views6 pages

Slab Design Eurocode

1) The document provides specifications and calculations for the design of a two-way reinforced concrete slab with a span of 7000mm x 4000mm that is part of an office building. 2) The minimum required slab thickness is calculated to be 150mm based on deflection limits. 3) Reinforcement requirements are calculated for bending moments in the short and long spans of the slab. Top and bottom reinforcement of H10 bars are specified with areas ranging from 0 to 375mm2/m depending on the location within the slab.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Example 7.

4 : Two-way Restrained Slab page 1/6

Ref. Calculations Output

SPECIFICATION Office - Computer room

A B C D
7000 7000 7000

4000

4000

Plan view

Characteristic Actions:
2
Permanent, g k = 1.5 kN/m (Excluding selfweight)
2
Variable, q k = 3.0 kN/m
Design life = 50 Years (Table 2.1 EN 1990)
Fire resistance = R60 (Sec. 5.7 EN 1992-1-2)
Table 4.1 Exposure classes = XC3
Materials :
2
Characteristic strength of concrete, f ck = = 30 N/mm (Table F.1 EN 206)
2
3.1.2(3) Characteristic strength of steel, f yk = 500 N/mm
Unit weight of reinforced concrete = 25 kN/m3 (Table A.1 EN 1991-1)
Assumed: f bar = 10 mm

Design slab panel C-D / 2-3

Long span, l y = 7000 mm l y/l x = 1.75 < 2.0


Short span, l x = 4000 mm Two-way slab

SLAB THICKNESS
Minimum thickness for fire resistance = 80 mm Table 5.8 EN 1992-1-2
Table 7.4N Estimated thickness considering deflection control, Try,
h = 4000 / 35 = 114 mm h = 150 mm

msy '09

Example 7.4 : Two-way Restrained Slab page 2/6

Prepared by msy 28/2/2023 Page 1


Ref. Calculations Output

DURABILITY, FIRE & BOND REQUIREMENTS


Table 4.2 Min. cover with regard to bond, C min,b = 10 mm
Table 4.4N Min. cover with regard to durability, C min,dur = 20 mm
4.4.1.2 Min. required axis distance for R60 fire resistance Table 5.8 EN 1992-1-2
a = 15 mm
Min. cover with regard to fire,
C min = a - f bar/2 = 15 - 0.5 (10) = 10 mm

4.4.1.3 Allowance in design for deviation, D C dev = 10 mm

4.4.1.1(2) Nominal cover, Use:


C nom = C min + DCdev = 20 + 10 = 30 mm C nom = 30 mm

ACTIONS
Slab selfweight = 0.150 x 25 = 3.75 kN/m2
Permanent load (Excluding selfweight) = 1.50 kN/m2
Characteristic permanent action, g k = 5.25 kN/m2
Characteristic variable action, q k = 3.00 kN/m2
Design action, n d = 1.35g k + 1.5q k = 11.59 kN/m2 Table A1.2B : EN 1990

ANALYSIS
ly /lx = 7000 / 4000= 1.75 < 2.0 Two way slab
Case 8 : Three edges discontinuous, one short edge continuous Table 3.14 : BS 8110
Bending moments,

M sx1
M sy1
M s y2

Short span: 2
M sx1 = b sx1 n d l x2 = 0.096 x11.59 x 4.0 = 17.8 kNm/m
2
M sx2 = b sx2 n d l x2 = 0.000 x11.59 x 4.0 = 0.0 kNm/m

Long span: 2
M sy1 = b sy1 n d l x2 = 0.044 x11.59 x 4.0 = 8.16 kNm/m
2
M sy2 = b sy2 n d l x2 = 0.058 x11.59 x 4.0 = 10.75 kNm/m

msy '09

Example 7.4 : Two-way Restrained Slab page 3/6

Ref. Calculations Output

Prepared by msy 28/2/2023 Page 2


MAIN REINFORCEMENT
Effective depth,
d x = h -C nom -0.5f bar = 150 - 30 - 10/2 =115.0 mm
d y = h -C nom -1.5f bar = 150 - 30 - 10(1.5) =105.0 mm

9.2.1.1 Minimum and maximum reinforcement area, Secondary bar :


A s,min = 0.26(f ctm/f yk) bd = 0.26 x (2.90 / 500) x bd H10 - 425
= 0.0015 bd = 0.0015 x1000 x 115 = 173 mm2/m (185 mm2/m)
2
A s,max = 0.04Ac = 0.04 x1000 x 150 = 6000 mm /m

Short span :
- Midspan , M sx = 17.8 kNm/m
6.1 K = M / bd 2f ck
2
= 17.8 x 106 / (1000 x 115 x 30)
= 0.045 < K bal = 0.167
Compression reinforcement is not required
z = d [ 0.5 + 0.25 - K /1.134) ] = 0.96 d ≤ 0.95d
A s = M / 0.87 f yk z Use:
6
= 17.8 x 10 / (0.87 x 500 x 0.95 x 115 ) H10 - 200 bot.
= 375 mm2/m 2
(393 mm /m)

- Support , M sx = 0.0 kNm/m


6.1 K = M / bd 2f ck
2
= 0.0 x 106 / (1000 x 115 x 30)
= 0.000 < K bal = 0.167
Compression reinforcement is not required
z = d [ 0.5 + 0.25 - K /1.134) ] = 1.00 d ≤ 0.95d
A s = M / 0.87 f yk z Use:
= 0.0 x 106 / (0.87 x 500 x 0.95 x 115 ) H10 - 300 top.
= 0 mm2/m 2
(262 mm /m)

Long span :
- Midspan , M sy = 8.2 kNm/m
6.1 K = M / bd 2f ck
2
= 8.2 x 106 / (1000 x 105 x 30)
= 0.025 < K bal = 0.167
Compression reinforcement is not required
z = d [ 0.5 + 0.25 - K /1.134) ] = 0.98 d ≤ 0.95d
A s = M / 0.87 f yk z Use:
= 8.2 x 106 / (0.87 x 500 x 0.95 x 105 ) H10 - 300 bot.
= 188 mm2/m 2
(262 mm /m)

msy '09

Example 7.4 : Two-way Restrained Slab page 4/6

Ref. Calculations Output

- Support , M sy = 10.8 kNm/m


6.1 K = M / bd 2f ck
2

Prepared by msy 28/2/2023 Page 3


2
= 10.8 x 106 / (1000 x 115 x 30)
= 0.027 < K bal = 0.167
Compression reinforcement is not required
z = d [ 0.5 + 0.25 - K /1.134) ] = 0.98 d ≤ 0.95d
A s = M / 0.87 f yk z Use:
6
= 10.8 x 10 / (0.87 x 500 x 0.95 x 115 ) H10 - 300 top.
= 226 mm2/m 2
(262 mm /m)

SHEAR
Shear force, Table 3.15 : BS 8110

Vsx2
Vsy1 Vsy2
Vsx1

Short span:
V sx1 = b vx1 n d l x = 0.45 x11.59 x 4.0 = 20.9 kN/m
V sx2 = b vx2 n d l x = 0.45 x11.59 x 4.0 = 20.9 kN/m
Long span:
V sy1 = b vy1 n d l x = 0.45 x11.59 x 4.0 = 20.9 kN/m
V sy2 = b vy2 n d l x = 0.30 x11.59 x 4.0 = 13.9 kN/m

Design shear force, V Ed = 20.9 kN


6.2.2 Design shear resistance,
V Rd,c = [ 0.12 k (100r 1 f ck)1/3 ] bd

k = 1 + (200/d )1/2 < = ≤2.0


2.0
1/2
= 1+(200 / 115) = 2.32 ≤ 2.0
r 1 = A sl/bd ≤ 0.02
= 393 / (1000 x 115) = 0.0034 ≤ 0.02
1/3
V Rd,c = 0.12 x 2.0 x (100 x 0.0034 x 30) x 1000 x 115
= 59945 N = 59.9 kN
V min = [ 0.035k 3/2f ck1/2 ] bd
3 /2 1/2
= 0.035 x 2.0 x 30 x 1000 x 115
= 62355 N = 62.4 kN

So, V Rd,c = 62.4 kN > V Ed Ok !

msy '09

Example 7.4 : Two-way Restrained Slab page 5/6

Ref. Calculations Output

7.4 DEFLECTION
Percentage of required tension reinforcement,
r = A s,req / bd
= 375 / 1000 x 115 = 0.0033

Prepared by msy 28/2/2023 Page 4


Reference reinforcement ratio,
1/2
r o = (f ck) 1/2 x 10-3 = (30) x10-3 = 0.0055

Table 7.4N Factor for structural system, K = 1.0


r < ro Use equation (1)

l  ro r 
3 / 2

 K 11  1 . 5 f ck  3 .2 f ck  o  1   (1)
d  r  r  

= 1.0 (11 + 13.8 + 9.87) = 34.7


Modification factor for span,span less than 7 m
= 1.00
Modification factor for steel area provided,
= A s,prov/A s,req = 393 / 375 = 1.05 ≤ 1.5
Therefore allowable span-effective depth ratio,
(l /d )allowble = 34.7 x 1.00 x 1.05 = 36.38
Actual span-effective depth
(l /d )actual = 4000 / 115 = 34.8 < (l /d )allowble Ok !

CRACKING
7.3.3 h = 150 mm < 200 mm Ok!
9.3.1 Main bar :
S max,slabs = 3h ≤ 400 mm = 400 mm
Max. bar spacing = 300 mm < S max,slabs Ok !
Secondary bar :
S max,slabs = 3.5h ≤ 450 mm = 450 mm Ok !
Max. bar spacing = 425 mm < S max,slabs

msy '09

Example 7.4 : Two-way Restrained Slab page 6/6

Ref. Calculations Output

DETAILING

Prepared by msy 28/2/2023 Page 5


Dimension:
Short span, l x = 4000 mm Thickness, h = 150 mm
Long span, l y = 7000 mm Concrete cover = 30 mm

Reinforcement:
01 H10 - 200 bot.
02 H10 - 300 top.
03 H10 - 300 bot.
04 H10 - 300 top.
05 H10 - 425 top.
06 H10 - 425 top.
07 H10 - 425 top.
08 H10 - 425 top.
09 H10 - 425 top.
10 H10 - 425 top.

msy '09

Prepared by msy 28/2/2023 Page 6