100% found this document useful (1 vote)
2K views2 pages

Loop Test Sheet

This document records the results of an integral loop function test. It tests various inputs, outputs, alarms and indicators related to process control loops. The test checks analog and digital inputs and outputs, control valves, on/off valves, and alarms. Readings are recorded from the field, HMI, DCS and other sources to verify everything is functioning as intended. Notes are included to document any issues found during the test.

Uploaded by

fadhlan hidayat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views2 pages

Loop Test Sheet

This document records the results of an integral loop function test. It tests various inputs, outputs, alarms and indicators related to process control loops. The test checks analog and digital inputs and outputs, control valves, on/off valves, and alarms. Readings are recorded from the field, HMI, DCS and other sources to verify everything is functioning as intended. Notes are included to document any issues found during the test.

Uploaded by

fadhlan hidayat
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

REKAYASA Date Name

Print Sub-Contractor Certificate


JB Contractor Date Control
: Owner
Signature EPC FASILITAS no. 400560 QA/QC Approval
QA/QC Approval
PENGUKURAN GAS
QI - J05 QA/QC Approval
Room

SENORO – PAU Page :


INTEGRAL LOOP FUNCTION TEST RECORD
Client : JOB-PERTAMINA-MEDCO E&P TOMORI SULAWESI

LOOP No. :

LOOP DIAGRAM No. : …………...…………………… rev. :…….. AREA/LOCATION : …………...………………...……………


Analog Input
(FLOW COMM, HMI) Measuring Scale Range Simulated Flow Comm HMI
Tag No. : Range (Unit) ( Unit ) Input Reading Reading

W/Calibration Test used :


……………………………
……………………………
Alarm / Trip
(HMI) Setting Result
Tag No. : HH
H
L
LL
Digital Input
Field DCS Alarm Annunciator ESD
Tag No. : Switch
Open
Close

Control output Control Control Valve


Tag No. : output Position (mA)
0% .mA
25% .mA
50% .mA This Valve is Air Failuree
75% .mA [ ] Open [ ] Close
100% .mA note : as per data sheet

On/Off Valve On / Off Valve


Output Position (%)
Tag No. : This Valve is Air Failuree
Open .% [ ] Open [ ] Close
Close .% note : as per data sheet

Digital Output
Output Field HMI Local Control Panel
Tag No. : Open
Close

Graphic Display on Console : ………………………………………………………………………………………….

NOTE : ………………………………………………………………………………………………………………………………..
………………………………………………………………………………………………………………………………..
………………………………………………………………………………………………………………………………..

PT. Pratiwi Putri Sulung JOB-PMTS


Field Tester Control Room
REKAYASA Date Name
Print Sub-Contractor Certificate
JB Contractor Date Control
: Owner
Signature EPC FASILITAS no. 400560 QA/QC Approval
QA/QC Approval
PENGUKURAN GAS
QI - J06 QA/QC Approval
Room

SENORO – PAU Page :


INTEGRAL LOOP FUNCTION TEST DCS RECORD
Client : JOB-PERTAMINA-MEDCO E&P TOMORI SULAWESI

LOOP No. :

LOOP DIAGRAM No. : …………...…………………… rev. :…….. AREA/LOCATION : …………...………………...……………


Analog Input
(PCS/ESD/FGS) Measuring Scale Range Simulated Local HMI
Tag No. : Range (Unit) ( Unit ) Input Indicator Reading

W/Calibration Test used :


……………………………
……………………………
Alarm / Trip
(PCS/ESD/FGS) Setting Result Alarm / Trip (DCS) Setting Result
Tag No. : HH Tag No. : HH
H H
L L
LL LL
Digital Input
(PCS/ESD/FGS) Field DCS Alarm Annunciator ESD
Tag No. : Switch
Open
Close

Control output (PCS) Control Control Valve Position


Tag No. : output Positioner Field Feedback (HMI)
0% This Valve is Air Failuree
25% [ ] Open [ ] Close
50% note : as per data sheet

75%
100%

On/Off Valve (PCS/ESD) On / Off Valve


Output Position (%)
Tag No. : This Valve is Air Failuree
Open .% [ ] Open [ ] Close
Close .% note : as per data sheet

Digital Output
(PCS/ESD/FGS) Output Field HMI Local Control Panel
Tag No. : Open
Close

Graphic Display on Console : ………………………………………………………………………………………….

NOTE : ………………………………………………………………………………………………………………………………..
………………………………………………………………………………………………………………………………..
………………………………………………………………………………………………………………………………..

PT. Pratiwi Putri Sulung JOB-PMTS


Field Tester Control Room

You might also like