Technical Information
DOWLEX™ 2006G
Polyethylene Resin
Overview Dowlex™ 2006G Polyethylene Resin is an ethylene 1-octene copolymer, suitable for cast film applications and also
perfectly designed to give excellent filler acceptance and low torque during compounding.
Dowlex™ 2006G offers superior stiffness and excellent temperature resistance making it the perfect partner for down
gauging. Films produced using Dowlex™ 2006G offer low shrinkage which is ideal when registered printing is used.
Main Characteristics:
• Optimum extruder output and process ability, pure or in blends
• Superior stiffness and temperature resistance
Complies with:
• Europe Commission Regulation (EU) No 10/2011
• U.S. FDA 21 CFR 177.1520(c )3.2a
Consult the regulations for complete details.
Additive • Antiblock: No • Slip: No • Processing Aid: No
Physical Nominal Value (English) Nominal Value (SI) Test Method
Density 0.961 g/cm³ 0.961 g/cm³ ASTM D792
1 0.963 g/cm³ 0.963 g/cm³ Dow Method
Base Density
Melt Index (190°C/2.16 kg) 8.0 g/10 min 8.0 g/10 min ASTM D1238
Films Nominal Value (English) Nominal Value (SI) Test Method
Film Thickness - Tested 1 mil 20 µm
Tensile Strength ASTM D882
MD : Break, 0.79 mil (20 µm) 5510 psi 38.0 MPa
TD : Break, 0.79 mil (20 µm) 2760 psi 19.0 MPa
MD : 0.79 mil (20 µm) 2 3050 psi 21.0 MPa
2 2180 psi 15.0 MPa
TD : 0.79 mil (20 µm)
Tensile Elongation ASTM D882
MD : Break, 0.79 mil (20 µm) 700 % 700 %
TD : Break, 0.79 mil (20 µm) 15 % 15 %
Elmendorf Tear Strength ASTM D1922
MD : 0.79 mil (20 µm) 29 g 29 g
TD : 0.79 mil (20 µm) 390 g 390 g
Extrusion Notes
Cast film extrusion conditions:
• Melt Temperature: 220°C
• Die gap: 0.7 mm
• Film thickness: 20 microns
Notes
These are typical properties only and are not to be construed as specifications. Users should confirm results by their own tests.
1
Base density is estimated using the assumption that every 1000 ppm of antiblock in the finished product raises the density of the
polymer by 0.0006 g/cm³. Base density is the estimated density of the polymer if it did not contain any antiblock.
2
@ 5% Elongation
Form No. 400-00234716en
Page: 1 of 2 ® ™ Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow. Rev: 2014-07-01
Product The Dow Chemical Company and its subsidiaries (“Dow”) has a fundamental concern for all who make,
distribute, and use its products, and for the environment in which we live. This concern is the basis for our
Stewardship Product Stewardship philosophy by which we assess the safety, health, and environmental information on
our products and then take appropriate steps to protect employee and public health and our environment.
The success of our Product Stewardship program rests with each and every individual involved with Dow
products ─ from the initial concept and research, to manufacture, use, sale, disposal, and recycle of each
product.
Customer Dow strongly encourages its customers to review both their manufacturing processes and their
applications of Dow products from the standpoint of human health and environmental quality to ensure
Notice that Dow products are not used in ways for which they are not intended or tested. Dow personnel are
available to answer your questions and to provide reasonable technical support. Dow product literature,
including safety data sheets, should be consulted prior to use of Dow products. Current safety data sheets
are available from Dow.
Medical NOTICE REGARDING MEDICAL APPLICATION RESTRICTIONS: Dow will not knowingly sell or sample
any product or service (“Product”) into any commercial or developmental application that is intended for:
Applications Policy a. long-term or permanent contact with internal bodily fluids or tissues. “Long-term” is contact which
exceeds 72 continuous hours;
b. use in cardiac prosthetic devices regardless of the length of time involved (“cardiac prosthetic devices”
include, but are not limited to, pacemaker leads and devices, artificial hearts, heart valves, intra-aortic
balloons and control systems, and ventricular bypass-assisted devices);
c. use as a critical component in medical devices that support or sustain human life; or
d. use specifically by pregnant women or in applications designed specifically to promote or interfere with
human reproduction.
Dow requests that customers considering use of Dow products in medical applications notify Dow so that
appropriate assessments may be conducted. Dow does not endorse or claim suitability of its products for
specific medical applications. It is the responsibility of the medical device or pharmaceutical manufacturer
to determine that the Dow product is safe, lawful, and technically suitable for the intended use. DOW
MAKES NO WARRANTIES, EXPRESS OR IMPLIED, CONCERNING THE SUITABILITY OF ANY DOW
PRODUCT FOR USE IN MEDICAL APPLICATIONS.
Disclaimer NOTICE: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because
use conditions and applicable laws may differ from one location to another and may change with time, the
Customer is responsible for determining whether products and the information in this document are
appropriate for the Customer’s use and for ensuring that the Customer’s workplace and disposal practices
are in compliance with applicable laws and other governmental enactments. Dow assumes no obligation
or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE
EXPRESSLY EXCLUDED.
NOTICE: If products are described as “experimental” or “developmental”: (1) product specifications may not be fully determined;
(2) analysis of hazards and caution in handling and use are required; (3) there is greater potential for Dow to change specifications
and/or discontinue production; and (4) although Dow may from time to time provide samples of such products, Dow is not obligated
to supply or otherwise commercialize such products for any use or application whatsoever.
NOTICE: This data is based on information Dow believes to be reliable, as demonstrated in controlled
laboratory testing. They are offered in good faith, but without guarantee, as conditions and method of use
of Dow products are beyond Dow’s control. Dow recommends that the prospective user determine the
suitability of these materials and suggestions before adopting them on a commercial scale.
To the best of our knowledge, the information contained herein is accurate and reliable as of the date of
publication, however we do not assume any liability for the accuracy and completeness of such
information.
Additional North America Europe/Middle East +800-3694-6367
U.S. & Canada: 1-800-441-4369 +31-11567-2626
Information 1-989-832-1426 Italy: +800-783-825
Mexico: +1-800-441-4369
Latin America South Africa +800-99-5078
Argentina: +54-11-4319-0100
Brazil: +55-11-5188-9000
Colombia: +57-1-219-6000 Asia Pacific +800-7776-7776
Mexico: +52-55-5201-4700 +603-7965-5392
www.dowplastics.com This document is intended for use within Europe
Published: 2013-09-30
© 2019 The Dow Chemical Company
Form No. 400-00234716en
Page: 2 of 2 ® ™ Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow. Rev: 2014-07-01