We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 5
AS950
PORTABLE SAMPLER
Applications
‘Wastewater
‘Collection systems
+ Industrial pretreatment
‘+ Environmental monitoring
+ Stormwater
Sampling has never been this easy.
The AS950 sampler controller makes programming, data transfer and operation more
intuitive and error free
Easiest and most intuitive operation
The large full colour display and intuitive programming give you
access to all your programmable criteria on a single screen -
eliminating scroling through menus and supporting error-free
operation.
Most convenient data transfer and
programming available
‘The AS950 is the only sampler that ullises a USB drive to upload
and download data and copy programs from one sampler to
another.
Confidence in your sampling process
‘The program status screen instantly communicates alarms,
missed samples and program progress for quick and easy
troubleshooting
Field convertible for compact
or discrete sampling
Weighing only 12.7 kg, the AS950 portable sampler is designed
for accuracy and convenience. Quickly switch between
composite and siscrete sampiing in the field. Configurable for
single or multiple bottle applications, itis specifcally designed
for use in 18-inch manholes
Easy maintenance at low cost
Spring-mounted rollers provide long tubing life keeping
maintenance costs low. The desiccant and pump tubing can
easily be accessed, the replacement is possibie without any
tools. The rugged see-through pump cover is made for a quick
visual inspection.
ENVIRONMENTAL
MONITORING
SOLUTIONSTechnical Da‘
AS950 Portable Sampler
Housing material Impact resistant ABS plastic,
3-section construction Double-walled
base with 2.54 cm insulation, direct
ice contact with bottles (Sampler)
Operating: 0 - 49°C
‘Storage: -40 - 60°C
Power requirements None
Woltage)
Dimensions (WxHxD) Standard Base: 50.5 om x 69.4 cm
Temperature
Compact Base: 44.1 om x 61 om
Composite Base:
50.28 om x 79.75 em
Standard 18 kg with (24) 11L
Polyethyione bottles; 14.8 kg
with 10 L Polyethyione bottle
Compact Base: 12.2 kg with
(24) 575 mL Potyethylene bottles;
12.9 kg with 10 L Polyethyione bottle
Composite Base: 15 kg with
(1)21 L Polyethylene bottie
Weight
‘AS950 Controller
Housing material PCIABS blond, NEMA 4X, 6, P68,
corrosion and ica resistant (Controller)
Display 1/4 VGA, Colour; sel-promptingy
rmenu-dtven program
Usor interface Membrane switch keypad with
2 multiple function soft koys.
Languages user Engish, French, Spanish, Italian,
interface German, Portuguese, Chinese
Lock function ‘Access code protection provents
tampering
Memory ‘Sample history: 4000 records
Data log: 325,000 records:
Event log: 2000 records
Communication USB and optional RS485 (MODBUS)
capabilities
Inputs (One 0/4-20 mA input for flow pacing
Certifications CE, UL
AS950 Portable Sampler
‘Sample container
STANDARD BASE CAPACITY:
{24) 1 | Polyethylene or 360 ml. Giase bottles
(8) 2.3L Povethylone or 1.9 Glass bottles
(4) 3.8 L Polyethylene or 3.8 L Glass bottles
(2) 3.8 L Polyethylene or 3.8 L Glass bottles
(1) 21 L Polyethylene composite bottle or
(1) 15 L Polyethylene composite bottle or
{1) 201 Povetnylene composite botte or
{1) 10L Pobetrylene or 10 Glass composite bottle
COMPACT BASE CAPACITY:
(24) 875 mL Polyethylene bottles
(@) 950 mL Glass bottles
(1) 10 L Polyethylene o 10 L Glass bottle
COMPOSITE BASE CAPACITY:
(1) 21 L Povethylene bottle
ICE CAPACITY:
‘Compact Base: 2.9 kg with (24) 575 mL. PE bottles
Standard Base: 14.5 kg with (24) 350 mL Glass bottles
“Sunect to change witout note
( . ’ : ENVIRONMENTAL
= x
MONITORING
tad ‘> SOLUTIONSAS950 Portable Sampler
Technical Da‘
Sampling Features
Programs,
Dual Programs: Up to 2 sample programs can be run
soquontaly, in paratol, or accorcing to day of wook schoduiing:
jenabling a single sampler to function ike multiple samplers.
‘Sampling mode
Pacing: Time weighted, Flow weighted, Time table,
Flow table, Event
Distribution: Single bottle composite, mult-bottle compost,
mut-botte discrete, bottles per sample, samples per bottle or a
combination of bottes per sample and samples per bottle
Operating mode
Continuous oF non-continuous
Status messages
Communicates what program is running, if there are any missod
samples, whan the next sample willbe taken, how many sampios
remain, number of logged channels, time of last measurement,
memory available, numberof active channels, if alarms were
triggered, when alarms were triggered, active sensors and cabinet
temperature
‘Alarm
Configurabie alarms that show on status screen and are
recorded in diagnostics alarm logs. Alarms can be set for system
siagnostics and logging such as program end, sample complete,
missed samples and full bottle, Channel alarms are setpoint
alarms for the recorded measurements (channels), such as pH,
level and power supply voliage.
Manual sampling
Intiates a samole collection independant of program in progress
‘Automatic shutdown
Multiple Bottle Mode: Alter complete revolution of distributor arm
(unless Continuous Mode is selected)
Composite Mode: After preset number of samples have been
delvered to composite container, from 1 to 999 samples, or upon
full contaier.
Sample volume
Programmable in 10 mL increments from 10 to 10,000 mL
‘Sample interval
Selectable in single increments from 1 to 9999 flow pulses
‘1 to 9999 minutes in one minute increments
‘Sample ti
When equipped with flow sensor or pH/lemperature sensor or
peripheral monitoring options, sampling can be triggered upon an
‘upset concitton when feld selectable limits are exceeded
Data logging
SAMPLE HISTORY - Stores up to 4000 entries for sample tine
‘stamp, bottle number and sample status (success, bottle fl,
Finse error, user abort, dstibutor srror, pump fault, purge fail,
sample lineout, power fal and low main battery)
MEASUREMENTS - Stores up to 325,000 entries for selected
measurement channels in accordance with the selected logging
interval
EVENTS - Abiity to store up to 2000 entros in Sample History
logging. Records Powor On, Powor Fail, Frmwvare Undated,
Pump Fault, Distibutor Arm Error, Low Memory Battery, Low
Main Battery, User On, User Off, Program Started, Program
Resumed, Program Halted, Program Completed, Grab Sample,
Tube Change Required, Sensor Communication Errors, Cooing
Falled, Heating Fale, Thermal Error Corrected.
Diagnostics
‘View event and alarm logs as well as maintenance diagnostics
“Subject to charge wou notoe
( . ’ S ENVIRONMENTAL
= s
MONITORING
tad ‘> SOLUTIONS4 AS950 Portable Sampler
Technical Da‘
‘Sample Pump and Strainer Sample transport velocity
‘Sample pump 0.9 mvs with 4.6 m vertical lft, 4.9 m of 2/8" Ving intake tubing,
High-speed porstatc, dual roller, with 0.95 ID x 1.6 0D em
(@/8" 1D x 5/8" OD) pump tubo;
Pump body 1°37, Polycaroonate cover
Vertical lft
8.5 m using 8.8 m maximum of 3/8" Viny| intake tube at sea level
at 20 to 25°C.
Tubing
Pump tubing: 9.5 mm ID x 18.9 mm OD Silicone
Intake tubing: 1.0 - 4.78 m minimum length, 1/4" or 8/8" ID Vinyl
or 3/8” ID Teflonined Polyethylene with protective outer cover
(black or clear)
‘Sample volume repeatability
‘Typical: 15% of 200 mL sample volume with: 4.6 m vertical tt
4.9m of 28" Vinyl intake tube, single bottle, ful botte shutoff at
room temperature ancl 1524 m elevation
‘Sample volume accuracy
‘Typical: 45% of 200 mL. sample volume with: 4.6 m vertical it,
4.9m of 28" Vinyl intake tube, singe bottle, ful bottle shutoff at
room temperature ancl 1524 m elevation
21 °C and 1524 m elevation
Pump flow rate
4.8 Limin at 1 m vertical lit with 3/8" intake tube typical
Internal clock
41 second per day at 25°C
Intake
Strainers: Choice of Teflon and 316 Stainless Stee! construction,
‘or all 316 Stainless Stee! in standard size, high velocty, and low
profie for shallow depth applications
Purge: Air purged automatically before and after each sample;
‘duration automatically compensates for varying intake line lengths
Finso: Intake lino automatically rinsed with source liquid prior to
‘each samp, ftom 1 to 3 rinses
Rtres or Fault: Samole collection yale automaticaly repeated
{rom 1 to 8 times if sample not obtained on intial attemot
“Subject o change without note,
Dimensions
‘The AS9S0 Portable Sampler is designed for indoor or outdoor use, No secondary enclosure is required when operated within the specified
temperature range. The samoler consists of three main sections - the top cover, the center control system, and the bottlefbase section
held together by Stainless Stee! latches which serve as the connection point forthe optional suspension hamess. The lockable top cover
protects the controller from extreme weather and unauthorized use,
ian
‘cones ase
psy —=]
Composte Base
A ENVIRONMENTAL
= we) MONITORING
SOLUTIONSAS950 Portable Sampler
Order Information
ASP.2X00000000X 45950 Portable Sampler
Portable Sampler with AS980 Controle,
available in various configurations and.
with soveral factory installed ootions.
Controller and Base Options
3975 Compact insulated base for AS350
Portable Sampler
8976 Standard insulated base for AS95O
Portable Sampler
3561 Compost insulated base for AS9S0
Portable Sampler
Bottle Options and Accessories
1918 10 Polyethylene bottle, with cao
6494 20L Polyethylene bottle, with cap
737 Set of (24) | L Polvethyfene bottles, wih caps
1369 Sot of (24) 575 mL Polyethylene bottis,
with caos
2348, Set of (8) 950 mL. Glass bottes, with
Tefon-ined caps
2189 Retainer for (24) 250 mL Glass bottles
1422 Retainer for (8) 1.9 L Gass / (8) 2.3
Polyetinylene bottles or (24) 360 mL Glass /
(24) 575 ml. Polyethylene bottles
2347 Retainer for (@} 850 mL Glass botties
1502 Container support
3096 Retainer/full container shut-off
Distributors
9582 Distributor with arm for 24 bottle standarel
base and 12 boitle compact base
‘8580 Distributor with arm for 24 bottle compact
base
8584 Distributor wth arm for 2, 4 and 8 bole
standard base and & bottle compact base
‘Tubing and Strainers
920 7 m Ving intake tubing, 8/8" ID
922, 71m Teflon-ined Polyethylene tubing, 2/8"
ID (equires Connection Kit 2186)
926 Strainer, Tetlon/Stainioss Stool
2070 Strainer, 216 Stainless Stee!
2071 Strainer, for shalow depth applications,
316 Stainioss Stool
[ENVIRONMENTAL MONITORING SOLUTIONS LTD.
‘Unt, Prosidont Buldngs, Savile Stoo East,
‘Sheela, 84 700
Kies 2
2186 Connector Ki, for Telor-tined Polyethylene
tubing
4852 Strainer, high velocity and shallow depth
4600-15, Pump tubing, 4.5m
4600-50 Pump tubing, 18 m
964 Pump tube insort
19501400 Pump tube insert, non-contact liquid detect
Factory Installed Options
‘TWO SENSOR PORTS
Accepts HACH LANGE clita Differential pH, HACH LANGE
‘digital AV9000 analyser with submerged area velocity flow and/or
HACH LANGE digtal US9000 ultrasonic level sensors,
PAIN/RS485 PORT
Accepts HACH LANGE Rain Gauge (not included) or can be used
‘as RSA85 communications
NON-CONTAGT LIQUID DETECT
Sample volume accuracy for applications that require complete
tubing replacement
Inputs/Outputs
‘9494500 109001 Module (connects through auxiliary
port), includes 1 relay (high vottage)
9494600 109004 Module (connects through auxiliary
port), includes muttisle O/4-20 mA outputs
and inputs
Accessories
1355 ‘Suspension hamess (suspends the sampler)
9542 Manhole support brackel/spanner,
18 to 28 inches
9557 Manhole support bracket/spanner,
28 to 48 inches
5713000 Manhole support bracket, 18 to 27 inches
6987 ‘Weathorguard fiserglass enciosure,
89 om x 89 cm x 86 cm
6902 ‘Weatherguard fiseralass enclosure,
91 om x 66.cmx 135 cm,
8713200 Solar Modul, with 10 W panel and
12 VDC regulator
‘8754400 12V/Lead Acid battery with 3 pin connector
'8753500EU EU Charger, Lead Acid, 3 pin, 220 V 3
‘8754500EU Power supply, 3 pin connector, :
230, EU plug 3
'9504700EU USB cable, A to A (EU) 2g
Ps s4e 014 2722270
saa ytta 2722271
inlogBo-lutons co.uk
wv am soutons.0