SHOTPlus Standard
Calculations
July 2017
CALCULATION OPTIONS
• Calculations are found under the calculations menu.
• Visualise timing
• Angle of initation
• First movement
• Burden relief
• Time Envelope
• Quantities
• EBS logging report
• EBS field report
2 © Orica Limited Group
VISUALISE TIMING
• Allows the sequence of the blast to be played
• to check firing sequence
• check burning front
• sequence step through using the space bar
• viewing at 5 different speeds
= surface initiation firing
= hole firing at collar
3 © Orica Limited Group
VISUALISE TIMING OPTIONS
Play Controls
• Play and pause buttons
• Time bar and current blast duration indicator
• Space bar to pause and jog blast forward
• Jog value depend on play speed selected
• Speed 1 = 5 ms
› 2 = 10 ms
› 3 = 20 ms
› 4 = 50 ms
› 5 = 100 ms
4 © Orica Limited Group
VISUALISE TIMING OPTION
Viewing and volume controls
• Shows same view as Design Window
• Toggle play back sound ON / OFF
• Shows hole flashes at collar or charge track
• Shows either blastholes only or other detail
from the design screen
5 © Orica Limited Group
ANGLE OF INITIATION
• Shows time contours on the design
• time contours are drawn through points of equal time
• used to indicate poor or out of sequence initiation design
• used to indicate firing direction and material movement
• used to indicate time relief within the blast
6 © Orica Limited Group
ANGLE OF INITIATION
• Contour intervals can be set either Manually or Automatically
Manual
Auto
7 © Orica Limited Group
FIRST MOVEMENT
• Calculates notional direction of blast movement perpendicular to time
contours
8 © Orica Limited Group
BURDEN RELIEF
• Calculates burden relief in the firing direction
• Burden relief is shown in milliseconds per metre of burden (ms/m)
• Used to highlight any anomalies in the initiation sequence or poor relief
9 © Orica Limited Group
TIME ENVELOPE
• Shows the number of charges or explosive weight firing within a
specified time window
10 © Orica Limited Group
TIME ENVELOPE
• Time window can be adjusted to user requirements
• Viewing can be by charges (decks) or total weight firing within the
specified time window
• Time window can be zoomed and scrolled
11 © Orica Limited Group
TIME ENVELOPE
• Drag across the time envelope to highlight firing holes on the design
screen
12 © Orica Limited Group
QUANTITIES
• Reports quantities of products used in the blast design
• Calculates lead length requirements for detonator products
13 © Orica Limited Group
QUANTITIES
Quantities will calculate based on:
• Tail length and ‘wastage’ factors input to loading options
• Products selected in availability selection
14 © Orica Limited Group
EBS LOGGING REPORT
• Manages the creation of Logging Plans and the download and upload
of logging data with i-kon™ loggers
15 © Orica Limited Group
EBS FIELD REPORT
Three tabs allow EBS firing records to be stored with the design file
1. Logger report allows recording of detonator numbers, harness wire
quantities any leakage associated with loggers
2. Comments allows any notes associated with the blast to be
recorded
3. Blaster Printout allows the print function of the i-kon blaster to send
to the SHOTPlus5 file. This allows for a record of any leakage at
blasting voltage or errors encountered.
16 © Orica Limited Group