0% found this document useful (0 votes)
340 views4 pages

Stavol Single

stavol-single
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
340 views4 pages

Stavol Single

stavol-single
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 4
LS Automatic Voltage Regulators I —a— Matsunaca Stavol ac aUTOMATC. VOLTAGE REGULATIR MODEL svc-1000N ee aes FY cel ry 220 Pn ‘Meksunaca 'SvC-5000NM STAVOL quality speaks for itself. Precision-crafted, accurate and highly efficient—these units offer a host of peerless qualities including rapid correction, zero-waveform distortion, a wide range of input voltages and a compact and lightweight construction. STAVOL units are ideal for all electrical appliance/constant input voltage applications. Do not settle for less than the best. “mSpecifications NW MODEL e Input Voltage | B0v= T30v/160V~240V Output Voltage 110V/220V+3% [Een Phase Single-phase Frequency 50H2/60H2 Response Time ‘Witin 65sec, agsst 10% input vorage devavion. | Within 08a, against 1O%inpui volage deviation Efficiency [Better than 90% (input voltage 180. output voltage 220V and at rated load) Power Factor [Better than 95% (input voltage 180, output voltage 220V and at rated load) ‘Ambient Temperature 5c~ +40 “Ambient Humidity I Tess than 90% (relative humidity) Temperature Rise [Less than 75°C (input voltage 180V, output voltage 220V and at rated load) Cooling System Convoton-cooled (Mal 2VA~TOWA Airbast_| Convection cooked (Model 33VA~ 1OK/A Ar bla) Contro! System DC servo-motor Style | Stand-alone style Insulation Resistence More than 3M@ at OC 500V Dielectric Strength Tested at AC 1500V for 1 min Y @ Applications * Computers ray equipment + Auto process contol equpment industrial robots ‘Test equipment * Communication systems * Broadcasting equipment + Laboratory struments “Lighting equipment “Macical equpment Photograph processing equipment + TV sets, ‘Alarm and security systems + Caleulating machines + Numeree control machine tools. * Hi-fi equipment Inpit and ouut wavelorms Response tne Response tme Response ime © eee eon ato ages 0% reurtag cng Y0% end age 0 (Smaec/em) (0.tseciom (0 tsec/em (0.1sec/em) Model | Power Output | Input Vok D tem) | Heme) [Weight fa) 350VA T1600 | 110 | 3.6 500N 5O0vA 180138 55 75ON 750VA Single-phase 215 | 190 | 145 6.1 1000N AVA 215 | 190/145 5.5 SOON T.BRVA 235 |230__| 190 38 2000N 2A 50v~130V—pit0ve9% [250 | 271_| 2265 | 14 3000N 3A = 290 | 3a4_|285_| 23 5OOON BAVA 160V~240v——S220v+3% | 330| 387330] 34 7500N T.BWVA 330 [8/0370] 54 10000N 10KVA 370 70141 79 SOON BOOVA 1751 160110. 35 ‘OOoRiN TA] Nee 195 | 180/135 5.5 1 500NM_ 1. 5KVA wn 215 190 145 6.5 2g60nm 2ivA _vtove3% {235 | 230 | 19070 5-JOBONM 3kVA__150V~250V—< 250 | 271225 | 14 S000NM SkVA ~220V #3% 290 344 285 23 SyE-7500001 T.5KVA 330] 387330] 34 SUC-10000NM 1 iowa 330_| 5701370} 54 * Two atorent vattage can be supplied smultaneovaly nthe manner Hustates * Frequency S0/60H2 (GME OPERATING INSTRUCTIONS [mn 1. Please don't use “Stavot” in an overload condition or at over Figure 1_N MODEL current rating. If you tse “Stavol” in these aves, may be broken or bumed out. “Stavol” can supply full capacity in the aN aor ‘ange from + 10% to - 10% of input nominal voltage. And alzo Shave use NMtype model can supply ful capac in the range from 1452 t0 105 of mput nominal veltage. (See Figure t and 2) 2. |n.case you use “Stevol” at vey low input voltage, please use ‘Cin only small capacty of load condition. (See Figure and 2) 3. n case you use “Stavol” for 220V and 110V applications at, the same time as multi voltages usages, please use it at less than hat load conattion. (See Figure and 2). [And also you use “Staval” in 220V input voltage and 110V output votage or 110V inpuc and 220V output voluge as Step-up or step-down voltage usage, please use it inthe same condition of above NO-2 4. Ploace uso the good or much enough connecting cables: between “Stavol” and load equipment to avoid vltage drop. [And algo please use the good or much enough connecting cables between "Stavol” and power source. 50%. ur 3394 8 220V iMULTANESUS USE e Figure 1: The limited output capacity by using condtions 20% SwctE USE” (N model) Figure 2: The limited output capacity by using concstions, Do eee (NM model 180 16) 190 160 10 200270290 200200280) wapur voLTAGE inpur ourpur (@)Matsunaca Manufacturing Co, Ltd. 4:48, Tsunashima-rshi Schome, Konohuku, Yokohama 223 Ja Phone :Yoxohama 045-642.212% Faosimle: Yokohama 086-542-2141

You might also like