FX 400-2000 460V UL Electrical Diagram Montecchio 2205044709 Ed02
FX 400-2000 460V UL Electrical Diagram Montecchio 2205044709 Ed02
CHECK ALL ELECTRICAL CONNECTIONS TIGHTENING according with table below EACH
YEAR OR EACH 4000 WORKING HOURS depending on the first elapsed service interval.
DRYER RATE
Compulsory customer installation
SIZE
SUPPLY LINE
TOTAL FLA [A]
LARGEST MOTOR M1 FU FUSES M2 MOTOR FLA M3 MOTOR FLA Q2-Q3 SETTING Tightening Torque
VOLTAGE FLA [A] (RK or J type) [A] [A] POINT [A]
A
E15 460 / 60 10.4 8.4 15 2 --- 2.5 Contactor terminal M3.5 M4 M6 M8
Main Recomm. Torque [Nm] 1.5 2.5 4.0 6.0
E16 460 / 60 11.2 9.2 17.5 2 --- 2.5
Aux Recomm. Torque [Nm] 1.2 1.2 1.2 1.2
2 E17 460 / 60 13.3 11.3 20 2 --- 2.5
3 Transformer T1
4 E17,5 460 / 60 13.8 11.8 20 2 --- 2.5 Recomm. Torque [Nm] 0.5-1.0
5 E18 460 / 60 16.4 12.4 25 2 2 2.5
E18,5 - E19 460 / 60 18.3 14.3 25 2 2 2.5
1 3 5
SU E20 460 / 60 20.5 16.5 30 2 2 2.5
2 4 6 E21 460 / 60 21.0 17.0 30 2 2 2.5
1 3 5
[a] [b] FU NOTES
B
[c] 2 4 6
[a] Maximum fuses with regard to short circuit
protection of starter. Cable section might impose
fuses of smaller value. For indirect contact
protection, the safety condition must be verified at
MAIN SUPPLY
the installation place.
[b] Max cable length from protection (FU) to the unit:
1X0
L1 L2 L3GND 23ft (7m). SU size >= 1.25xFLA
[c] For field wiring: use copper wire only
[d] Q3, K3 and M3 only for codes 2205044704-5-6
[e] Only for codes 2205044705-6 02
F2
2 2 1X1 3
[e]
1X1
2 3
ELECTRICAL LEGEND
24V
9
L2
L3
L1
KPH
0 18 11 14 13 71 SU Disconnector switch (Customer installation)
KPH U K1
2-E FU Dryer protection fuses (Customer installation)
14 11 5-EL1 L2 L3 28 5-F
13 72 M1 Refrigerant Compressor motor
21
Q2 M2-M3 Fan motor
K1 4 5 1 2
24V
7
20 TC Control transformer
34
8
1X1 1X1 H3 Drain fault lamp
5 6 [d] PV Fan pressure switch
SL-EV A1 SL-EV2 A1 F
AP High pressure switch
6
2 4 6 2 4 6
5
A1 A1 A1 A1 1X4 A1 A1
H1 KS K2 K3 K1 21 K4 H2 K5 H3 A2 A2
T2 Temperature sensor P3 PTC - Compr. temp.
L22
L32
L21
L31
L12
L11
GN RD RD K4 Aux relay
This document is property of Atlas Copco AB and shall not without our permission be altered,
K1 K2 K3 KS 1 2 1 2 1 2 1 2
3 4 3-F 3 4 2-F 3 4 3-F 3 4 1-F
5-F 5-F 5-F 4-F 5 6 3-F 5 6 2-F 5 6 3-F 5 6 1-F
2 4 6 2 4 6 2 4 6 2 4 6 21 22 6-F 21 22 7-F 21 22 4-E
Tolerances,if not indicated,according to:
71 72 7-E
[d]
C
E
ATLAS COPCO STANDARD Class
W2
W1
V2
U2
V1
U1
W
V
U
K4 K5
Name SERVICE DIAGRAM E15-22 460/60 UL Confidentiality class
32
acc. to 1102 K
7-F 7-F
31
T1 T2 T3 T1 T2 T3 T1 T2 T3 Internal
R1
M1 M2 M3 Not Applicable
D
Treatment
F
M M M ACDE
1X1 1X1 1X1 1X1 G
3~ 3~ 3~
D C F E Scale Family Compare Drawing Transferred
[d] owner from
Drawn by Blank nr. Replaces
ATLASCOPCO\a00519193 ITJ
Note Position Modified from Date Intr./Appd. Drawing format Blank wt. Fini wt. Designation Sheet ( ) 01 01
- Kg Kg
STATUS A2
2205044709
ti
Approved. Date
t
28/07/2022 09:26:36
D