Medium Voltage Service Technical Flyer

Retrofit solutions for NGEF/AEG EKU make minimum oil


circuit breaker

The foremost advantage of retrofitting


a circuit breaker in switchgear is that
the required specifications are met
with the latest technology at only a
partial cost of replacing the equipment.
This becomes more evident when
the associated costs of civil works,
cabling and downtime are considered.
Retrofitting helps in saving up to 60
percent of the cost of new equipment
Typically, retrofitting constitutes
replacement of vital equipment having
similar or advanced features, for life
extension, reduced maintenance and
improved functionality. This includes
upgradation and modernization of
basic equipment and allied parts. The
retrofitted switchgear offers far greater
system reliability, long term availability
of spares and increased safety to the
operators with minimal investment and
NGEF/AEG EKU 7512 Breaker
downtime.
ABB is a full system provider for
retrofit solutions, from the proposal
and design, through the manufacturing
and testing, up to installation and
commissioning.
Benefits
Reliability
– Significant life time extension
– Lower maintenance requirements
– Long time availability of spare parts
Safety
– Strong fault risk reduction
– Additional embedded safety features
– Improved operator protection

1VYN000005 Rev.00, en - Copyright© 2014 ABB. All rights reserved. ABB.


Technology
– Latest generation apparatus
– Designed according to IEC 62271-100 Standard
– Tested and certified products
Project
– Short implementation time for replacement
– Minimum shutdown of the switchboard
– Smooth site activity
Investment
– Limited capital investment
– Minimization of further maintenance costs
– Warranty on the conversion work

Facts
These circuit breakers are widely present in the networks and
ABB can provide the relevant retrofitting solutions across the ABB VD4 vacuum retrofit of NGEF/GEC EKU breaker
globe. This equipment has been in service for many decades
and retrofitting could significantly extend the operational life
of the switchgear. The use of well proven VD4 Vacuum circuit
breaker enhances the reliability of the switchgear. The retrofit
circuit breakers can be fitted with Surge Arresters or Potential
Transformers on request. Many types of existing circuit For more information please contact service department at:
breakers can be identified by looking at the rating plates Viz.
ABB India Limited
EKU 5012/10, EKU 7512/10,EKU 5016/10, EKU7525/10,
PPMV – Retrofit & Services
GR 256 etc.
Plot No. 79, Street No. 17,
MIDC Estate,
Technical data
Satpur Nashik,
A full range of retrofit solutions have been developed
Maharashtra, India – 422007
based on ABB vacuum and gas circuit breakers. Fused
Tel: +91 253-2201200
vacuum contactor is also available for replacing Motor
Fax: +91 253-2351260
Starter Units. Perfect one to one interchangeability is
Email: [email protected]
guaranteed from electrical and mechanical point of view. 
ABB proposal provides the best fit for purpose apparatus for www.abb.com
each switchgear unit, depending on the complete network
equipment conditions and the specific feeder operational
NOTE:
characteristics.
We reserve the right to make changes in the course of technical
development.
The following basic details are necessary for providing
standard retrofit solutions:
– Height, width and depth of the circuit breaker compartment
– GA and schematic drawing of the existing panel
– Height, width and depth of the panel
– Control voltage
– Feeder details
– Four side pictures
– Data label and technical information and serial number
– Compartment inner pictures