E0.01 ELECTRICAL COVER SHEET Rev.0

This document contains information about branch circuit wiring schedules including breaker ratings and wire sizes for different circuits. It also contains various electrical symbols and abbreviations as well as a list of electrical drawing sheets. Circuit breakers range from 16A to 100A and are specified for single pole (SP) and triple pole (TP) configurations. Conduit sizes range from 25mm to 50mm depending on the circuit rating. Notes provide additional information on ambient temperatures and feeder requirements.

Uploaded by

Abdul Rahman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
128 views1 page

E0.01 ELECTRICAL COVER SHEET Rev.0

This document contains information about branch circuit wiring schedules including breaker ratings and wire sizes for different circuits. It also contains various electrical symbols and abbreviations as well as a list of electrical drawing sheets. Circuit breakers range from 16A to 100A and are specified for single pole (SP) and triple pole (TP) configurations. Conduit sizes range from 25mm to 50mm depending on the circuit rating. Notes provide additional information on ambient temperatures and feeder requirements.

Uploaded by

Abdul Rahman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

NOTES:

BRANCH CIRCUIT WIRING SCHEDULE ELECTRICAL LEGEND ELECTRICAL LEGEND ELECTRICAL SHEET LIST
BREAKER SURFACE MOUNTED PANEL
SHEET
F/S FIRE/SMOKE DAMPER
AMPERAGE POLE WIRE SIZE NUMBER SHEET NAME
16A SP 2 X 1C 4mm2 + 4mm2 E, 25mm Conduit E0.01 ELECTRICAL COVER SHEET
S SMOKE DAMPER PANEL RECESSED IN WALL E0.02 ELECTRICAL SCHEDULES
16A TP 4 X 1C 4mm2 + 4mm2 E, 25mm Conduit
20A SP 2 X 1C 4mm2 + 4mm2 E, 25mm Conduit E0.03 ELECTRICAL CABLE LIST
T
20A TP 4 X 1C 4mm2 + 4mm2 E, 25mm Conduit FACP FIRE ALARM CONTROL PANEL STEP DOWN TRANSFORMER E0.51 ELECTRICAL SITE PLAN
F
25A TP 4 X 1C 4mm2 + 4mm2 E, 25mm Conduit E0.52 ELECTRICAL SITE PLAN
30A/32A SP 2 X 1C 6mm2 + 6mm2 E, 32mm Conduit DUPLEX TYPE (WALL MOUNTED) SWITCHED SIMPLE RECEPTACLE, BS 1363 E0.53 ELECTRICAL SITE PLAN
GROUND BUS BAR
30A/32A TP 4 X 1C 6mm2 + 6mm2 E, 32mm Conduit TYPE, I PHASE, 230 VAC, 360 VA, 3 WIRES. ELEVATION = 300MM AFFL. E0.54 ELECTRICAL SITE PLAN
40A SP 2 X 1C 10mm2 + 10mm2 E, 25mm Conduit X/X/X E0.60 EARTHING PLAN - WEST
DUPLEX TYPE (WALL MOUNTED) GENERAL PURPOSE OUTLET, BS 1363 HEAVY DUTY DISCONNECT SWITCH, SURFACE MOUNTED,
40A TP 4 X 1C 10mm2 + 10mm2 E, 38mm Conduit E0.61 EARTHING PLAN - EAST
TYPE, I PHASE, 230 VAC, 360 VA, 3 WIRES. ELEVATION = 300MM AFFL. 600V, NON-FUSED TYPE
50A TP 4 X 1C 16mm2 + 16mm2 E, 50mm Conduit (I)NDOOR/ E2.01 POWER PLAN - GROUND FLOOR - OVERALL BUILDING
60A/63A TP 4 X 1C 25mm2 + 16mm2 E, 50mm Conduit (W)EATHER PROOF E2.02 POWER PLAN - GROUND FLOOR - AREA A
DUPLEX TYPE (CEILING MOUNTED) GENERAL PURPOSE OUTLET, BS 1363
70A TP 4 X 1C 25mm2 + 16mm2 E, 50mm Conduit NUMBER POLES E2.03 POWER PLAN - GROUND FLOOR - AREA B
TYPE, I PHASE, 230 VAC, 360 VA, 3 WIRES. ELEVATION = 300MM AFFL.
AMPERAGE E2.04 POWER PLAN - GROUND FLOOR - AREA C
80A TP 4 X 1C 35mm2 + 16mm2 E, 50mm Conduit
100A TP 4 X 1C 50mm2 + 25mm2 E, 50mm Conduit E2.05 POWER PLAN - GROUND FLOOR - AREA D
DUPLEX TYPE (WALL MOUNTED) SPECIAL PURPOSE OUTLET, BS 1363 HEAVY DUTY DISCONNECT SWITCH, SURFACE MOUNTED, 600V,
NON FUSED TYPE E2.06 POWER PLAN - GROUND FLOOR - AREA E
NOTES: TYPE, I PHASE, 230 VAC, 360 VA, 3 WIRES. ELEVATION = 300MM AFFL.
E2.07 POWER PLAN - GROUND FLOOR - AREA F
COORDINATE NEMA PLUG TYPE WITH OWNER. COMBINATION MOTOR STARTER/DISCONNECT SWITCH
1. BASED ON 40C AMBIENT AND 90C CONDUCTORS. RESIZE FEEDER FOR OTHER AMBIENT E2.11 POWER PLAN - FIRST FLOOR - AREA A
TEMPERATURES. E2.12 ELECTRICAL OVERALL ROOF PLAN
RCD DUPLEX TYPE (WALL MOUNTED) GENERAL PURPOSE OUTLET, BS 1363 VFD WITH DISCONNECT, COORDINATE WITH MECHANICAL
2. ALL FEEDERS SHALL BE XLPE COPPER, PVC SHEATHED UNLESS NOTED OTHERWISE. TYPE RESIDUAL CURRENT DEVICE (RCD), I PHASE, 230 VAC, 360 VA, VFD E2.21 MECHANICAL POWER - GROUND FLOOR - AREA A
CONTRACTOR
EARTHING WIRE SHALL BE PVC COPPER. 3 WIRES. ELEVATION = 300MM - 1200MM AFFL. E2.22 MECHANICAL POWER - GROUND FLOOR - AREA B
3. BRANCH CIRCUITS DO NOT ACCOUNT FOR VOLTAGE DROP. E2.23 MECHANICAL POWER - GROUND FLOOR - AREA C
EPO EMERGENCY POWER OFF SWITCH
4. BASED ON 3 CURRENT CARRYING CONDUCTORS IN RACEWAY. WP DUPLEX TYPE (WALL MOUNTED) GENERAL PURPOSE OUTLET, BS 1363 E2.24 MECHANICAL POWER - GROUND FLOOR - AREA D
TYPE WEATHER PROOF WITH RESIDUAL CURRENT DEVICE (RCD), E2.25 MECHANICAL POWER - GROUND FLOOR - AREA E
MOTORIZED SHADE CONTROL
I PHASE, 230 VAC, 360 VA, 3 WIRES. ELEVATION = 300MM - 1200MM AFFL. $ MS E2.26 MECHANICAL POWER - GROUND FLOOR - AREA F
E2.31 MECHANICAL POWER - FIRST FLOOR
FB DUPLEX TYPE (FLOOR MOUNTED) GENERAL PURPOSE OUTLET, BS 1363 $T THERMAL OVERLOAD SWITCH E2.41 CONDUIT ROUTING - GROUND FLOOR - AREA A
TYPE, I PHASE, 230 VAC, 360 VAC, 3 WIRES. 4 RJ45 PORTS. E2.42 CONDUIT ROUTING - GROUND FLOOR - AREA B
10 MOTOR CONNECTION, HP AS NOTED
DUPLEX TYPE (FLOOR MOUNTED) GENERAL PURPOSE OUTLET, BS 1363 E2.43 CONDUIT ROUTING - GROUND FLOOR - AREA C
FB 2
TYPE, I PHASE, 230 VAC, 800 VAC, 3 WIRES. E2.44 CONDUIT ROUTING - GROUND FLOOR - AREA D
M SINGLE PHASE MOTOR CONNECTION, HP AS NOTED
1/2 E2.45 CONDUIT ROUTING - GROUND FLOOR - AREA E
TELECOM/DATA OUTLET. PROVIDE BACK BOX/COVER PLATE.
E2.46 CONDUIT ROUTING - GROUND FLOOR - AREA F
INSTALL 20mm CONUIT W/BUSHING AND PULLSTRING, STUBBED TO J JUNCTION BOX, CEILING MOUNTED
ACCESSIBLE CEILING. REFER TO PLANS FOR MOUNTING HEIGHT E2.51 CONDUIT ROUTING - FIRST FLOOR
J E3.01 LIGHTING PLAN - GROUND FLOOR- OVERALL BUILDING
JUNCTION BOX, WALL MOUNTED
CEILING DATA OUTLET. PROVIDE BACK BOX/COVER PLATE. E3.02 LIGHTING PLAN - GROUND FLOOR - AREA A
INSTALL 20mm CONUIT W/BUSHING AND PULLSTRING, STUBBED TO E3.03 LIGHTING PLAN - GROUND FLOOR - AREA B
ACCESSIBLE CEILING. REFER TO PLANS FOR MOUNTING HEIGHT P
PULL BOX E3.04 LIGHTING PLAN - GROUND FLOOR - AREA C
B
E3.05 LIGHTING PLAN - GROUND FLOOR - AREA D
2 DUAL TELECOM/DATA OUTLET. PROVIDE BACK BOX/COVER PLATE. GROUND ROD (COPPER JACKETED STEEL ROD) E3.06 LIGHTING PLAN - GROUND FLOOR - AREA E
INSTALL 20mm CONUIT W/BUSHING AND PULLSTRING, STUBBED TO 16MM. DIA X 2.4MM E3.07 LIGHTING PLAN - GROUND FLOOR - AREA F
ACCESSIBLE CEILING. REFER TO PLANS FOR MOUNTING HEIGHT
E3.11 LIGHTING PLAN - FIRST FLOOR
16MM. DIA. X 2.4MM GROUND ROD WITH GROUNDING
E4.01 ENLARGED ELECTRICAL PLANS
SINGLE POLE SWITCH TESTING PIT
E4.02 ENLARGED ELECTRICAL PLANS
E4.03 ENLARGED ELECTRICAL PLANS
3 CIRCUIT BREAKER
THREE WAY SWITCH E4.04 ENLARGED ELECTRICAL PLANS
E5.02 TELECOM PLAN - GROUND FLOOR - AREA A
4 E5.03 TELECOM PLAN - GROUND FLOOR - AREA B
FOUR WAY SWITCH SWITCH AND FUSE
E5.04 TELECOM PLAN - GROUND FLOOR - AREA C
E5.05 TELECOM PLAN - GROUND FLOOR - AREA D
ENCLOSED CIRCUIT BREAKER
PC PHOTOCELL E5.06 TELECOM PLAN - GROUND FLOOR - AREA E
E5.07 TELECOM PLAN - GROUND FLOOR - AREA F
NORMALLY OPEN CONTACT
CEILING MOUNTED VACANCY OR OCCUPANCY SENSOR E5.08 TELECOM PLAN - FIRST FLOOR - AREA A
VS OS WATTSTOPPER DT-300 SERIES E5.09 TELECOM PLAN - GUARDHOUSE
NORMALLY CLOSED CONTACT
E6.01 ELECTRICAL DETAILS
E6.02 ELECTRICAL DETAILS
20MM DIA. CONDUIT RUN EMBEDDED ON SLAB NUMBERED NOTE
E6.03 ELECTRICAL DETAILS
E6.04 ELECTRICAL DETAILS
25MM DIA. CONDUIT RUN EXPOSED UNDER SLAB EXIT SIGN; WALL MOUNTED (REFER TO LIGHT FIXTURE E6.05 ELECTRICAL DETAILS
SCHEDULE)
E6.10 LIGHTING CONTROLS
EXIT SIGN; CEILING MOUNTED (REFER TO LIGHT FIXTURE E7.00 ELECTRICAL ONE-LINE DIAGRAM
NOTE:
SCHEDULE) E7.01 ELECTRICAL ONE-LINE DIAGRAM
• ALL LIGHTING SWITCHES SHOULD BE 10A UNLESS OTHERWISE INDICATED. FIXED CLOSED CIRCUIT CAMERA E7.02 ELECTRICAL ONE-LINE DIAGRAM
E7.03 ELECTRICAL ONE-LINE DIAGRAM
MS MOTION SENSOR E7.04 ELECTRICAL ONE-LINE DIAGRAM
E8.00 ELECTRICAL PANEL SCHEDULES (1 OF 11)
MAGNETIC LOCK E8.01 ELECTRICAL PANEL SCHEDULES (2 OF 11)
ML
E8.02 ELECTRICAL PANEL SCHEDULES (3 OF 11)
KP KEYPAD E8.03 ELECTRICAL PANEL SCHEDULES (4 OF 11)
E8.04 ELECTRICAL PANEL SCHEDULES (5 OF 11)
DC DOOR CONTACT E8.05 ELECTRICAL PANEL SCHEDULES (6 OF 11)
E8.06 ELECTRICAL PANEL SCHEDULES (7 OF 11)
PB PUSH BUTTON E8.07 ELECTRICAL PANEL SCHEDULES (8 OF 11)
E8.08 ELECTRICAL PANEL SCHEDULES (9 OF 11)
E8.09 ELECTRICAL PANEL SCHEDULES (10 OF 11)
CR CARD READER
E8.10 ELECTRICAL PANEL SCHEDULES (11 OF 11)

EL ELECTRIC LOCK

ES ELECTRIC STRIKE

CONDUIT CONCEALED IN CEILING OR WALL


ELECTRICAL ABBREVIATIONS
CONDUIT BELOW FLOOR OR IN SLAB (E)/EXIST EXISTING
(N) NEW
CONDUIT STUBBED OUT AND CAPPED W/PULLSTRING (R)/RELOC EXISTING TO BE RELOCATED
A AMPERES
A/V AUDIO/VISUAL
CONDUIT HOMERUN BACK TO PANEL
AF AMPERE FUSE RATING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AIC AMPERES INTERRUPTING CAPACITY
AL ALUMINUM
AT AMPERE TRIP RATING
ATS AUTOMATIC TRANSFER SWITCH
BKR BREAKER
BLDG BUILDING 0 11/1/2021 ISSUED FOR CONSTRUCTION
C CONDUIT
CCTV CLOSED CIRCUIT TELEVISION
REV.
CKT CIRCUIT DATE DESCRIPTION CHK'D CERT APP'D
CM CEILING MOUNTED No.
CU COPPER
DIA DIAMETER PROPRIETARY NOTICE
DPDT DOUBLE POLE DOUBLE THROW
ELEC ELECTRICAL
This drawing and the information contained herein are the exclusive property
EMT ELECTRICAL METALLIC TUBING ofNovel Non-Metallic Solutions and shall not be copied, reproduced or
EP EXPLOSION PROOF
FAAP FIRE ALARM ANNUNCIATOR PANEL
disclosed in any manner, or used for any purpose whatsoever, except with the
FACP FIRE ALARM CONTROL PANEL prior written authorization of Novel Non-Metallic Solutions. This drawing,
FWE FURNISHED WITH EQUIPMENT
GC GENERAL CONTRACTOR
including any documentation, drawings, calculation or other information
GFI/GFCI GROUND FAULT CIRCUIT INTERRUPTER prepared or derived from the information contained herein shall be returned to
GND GROUND
HP HORSEPOWER Novel Non-Metallic Solutions upon request.
IG ISOLATED GROUND
KVA KILO-VOLT AMPERE
PROJECT TITLE :
KW KILO-WATT
LTG LIGHTING
MCB MAIN CIRCUIT BREAKER NOVEL NON-METALLIC SOLUTIONS MANUFACTURING FACILITY
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MLO MAIN LUGS ONLY LOCATION :
MTD MOUNTED
MTS MANUAL TRANSFER SWITCH
NC NORMALLY CLOSED
NEUT NEUTRAL KING SALMAN ENERGY PARK (SPARK)
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE OWNER :
PB PULL BOX
PNL PANEL
PVC
SH
POLYVINYL CHLORIDE CONDUIT
SHIELDED
NOVEL NON-METALLIC SOLUTIONS MANUFACTURING
SWBD SWITCHBOARD
SWGR SWITCHGEAR CHECKED BY : APPROVED BY :
TC TIME CLOCK AR: A.Aleidi Zaheer Ahmed
TS TIME SWITCH
TVSS TRANSIENT VOLTAGE SURGE SUPRESSOR
ST: H.Ahmed
TYP TYPICAL ME: Abbas.H
UON
UPS
UNLESS OTHERWISE NOTED
UNINTERRUPTABLE POWER SUPPLY
EE: S.Joseph
V VOLT CHECKED DATE : APPROVED DATE :
WP WEATHERPROOF -- --
SHEET TITLE : DRAWING NUMBER : REV

ELECTRICAL COVER SHEET E0.01 0