0% found this document useful (0 votes)
143 views1 page

Sensor Instruction Manual

This document provides technical specifications for S62...M series background suppression sensors. Key specifications include: - Dimensions of 50x18x18mm and operating distances ranging from 30-2000mm depending on the model. - Power supply of 10-30VDC, output of 100mA maximum, and response times between 500us and 1.5ms. - Emitters of red LED or infrared, and spot/detection areas ranging from 6x6mm to 200x200mm depending on the model. - Adjustments for distance, light/dark sensitivity, and timer (for some models); and indicators for output, stability, and power. - Operating temperature range of -10°

Uploaded by

jediahftw
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
143 views1 page

Sensor Instruction Manual

This document provides technical specifications for S62...M series background suppression sensors. Key specifications include: - Dimensions of 50x18x18mm and operating distances ranging from 30-2000mm depending on the model. - Power supply of 10-30VDC, output of 100mA maximum, and response times between 500us and 1.5ms. - Emitters of red LED or infrared, and spot/detection areas ranging from 6x6mm to 200x200mm depending on the model. - Adjustments for distance, light/dark sensitivity, and timer (for some models); and indicators for output, stability, and power. - Operating temperature range of -10°

Uploaded by

jediahftw
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

TECHNICAL DATA DIMENSIONS

S62…M0-PP/PN/NN S62…M1-PP/PN/NN S62…M2-PP/PN/NN S62…M3-PP/PN/NN 50 18

0.75
1.1
Power supply: 10 … 30 VDC 42 4.7
Ripple: 2 Vpp max.

S62…M Consumption
(output current excluded):
40 mA max.
Background suppression Outputs: S62...PP/NN: PNP or NPN N.A./N.C. 30 VDC / S62...PN: NPN/PNP; 30 VDC max (short-circuit protection)

2
RECEIVER
Output current: 100 mA (overload and overvoltage protection)
INSTRUCTION MANUAL

18.2
2V

42
50
Output saturation voltage:
Response time: 500 s 1 ms 1,5 ms
EMITTER

18x45°
CONTROLS Switching frequency: 1 kHz 500 Hz 330 Hz

15.5
OUTPUT LED (yellow) Emission type: RED (660 nm) INFRARED (880 nm)
The yellow LED ON indicates that the N.O. output is closed and the N.C. Spot dimension: 6x6 mm (at 200 mm) 15x15 mm (at 400 mm) 200x200 mm (at 2000 mm)
output is open. 200…2000 mm

16
Operating distance (typical values): 30…300 mm 60…600 mm 60…1200 mm
(recommended target 400x400mm)
STABILITY LED (green) (S62…M2/M3)
When permanently ON, the green LED indicates a normal operating condition Adjustment: Multiturn distance adjustment trimmer / Timer adjustment trimmer (S62…M05/M15/M25/M35)
where the received signal has a safety margin superior to 30% respect to the DARK/LIGHT selection: mono-turn trimmer (S62…M01/M11-PN) - 11 6 14 M12
output switching value. The sensor is ready to function correctly (stability Difference (90% white / 4% black): <8% < 12 % < 25 % < 30 % Ø15
condition). Hysteresis (90% white): <5% < 20 % TIMER ADJUSTMENT
TRIMMER (mod.M05/M15/M25/M35)
POWER ON LED (green) (S62…M0/M1) Indicators: OUTPUT LED (YELLOW) / STABILITY LED (GREEN) OUTPUT LED (YELLOW) / POWER ON LED (GREEN) DARK/LIGHT
The green LED ON indicates the powering status and the laser emission TRIMMER 14 11 CABLE VERSION
Operating temperature: -10 … 55 °C (S62-M01/M11-PN)
presence.
Storage temperature: -20 … 70 °C 6.18 18.4
DISTANCE ADJUSTMENT TRIMMER (ADJ.)
A 6-turn trimmer allows the background suppression distance adjustment Dielectric strength: 500 VAC 1 min., between electronics and housing

Ø4
through a mechanical variation of the optic triangulation angle. Insulating resistance: >20 M 500 VDC, between electronics and housing
The operating distance increases, rotating the screws in a clockwise direction. Ambient light rejection: According to EN 60947-5-2
Please refer to the “SETTING” paragraph for acquisition or setup procedure Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for each axis (EN60068-2-6)
indications. 10.7 DISTANCE ADJUSTMENT TRIMMER
Shock resistance: 11 ms (30 G) 6 shock for each axis (EN60068-2-27)
POSITION INDICATOR
Housing material: ABS OUTPUT LED
POSITION INDICATOR
mm
This indicator presents a scale numbered from 1 to 6 that allows a precise STABILITY LED STABILITY
(S62…M2/M3)
Lens material: PMMA window; PC lens LED/
adjustment of the suppression distance in the entire operating range. POWER ON LED (S62…M0/M1)
Please refer to the “SETTING” paragraph for use indications. Mechanical protection: IP67
TIMER ADJUSTMENT TRIMMER (S62…M05/M15/M25/M35) Connections: 2 m cable  4 mm / M12 4-pole connector
This control allows to vary the output delay deactivation from 0 to 1 sec. UL requirements: they are intended to be connected to a Class 2 transformer or class 2 power supply TIMER FUNCTION (S62…M05/M15/M25)
Please refer to “TIMER FUNCTIONS” paragraph for use indications. Weight: 90 g. max. cable vers. / 40 g. max. connector vers. The timer function allows to adjust the output deactivation delay when the
DARK/LIGHT TRIMMER (S62…M01/M11-PN) object is outside the detection area. The delay extends the output activation
The LIGHT/DARK mode is selected using a mono-turn trimmer. allowing the slower interface systems to detect shorter pulses.
LIGHT MODE: clockwise rotation SETTING
DARK MODE: counter-clockwise rotation. Suppression distance setting
WARNING: the maximum mechanical rotation range of the trimmer is 240°.
Do not force over of the maximum and minimum positions. 1. Object detection
INSTALLATION Position object to detect in front of the sensor at the distance required. Rotate trimmer in an anticlockwise direction until yellow LED turns OFF
Turn distance adjustment trimmer (ADJ) to minimum: yellow LED OFF and and green LED ON: condition where background is outside operating
The sensor can be positioned by means green LED ON. range (C status of position indicator).
of the three housing’s holes using two
screws (M4x25 or longer, 1.5Nm max.
tightening torque) with washers.
Various orientable fixing brackets to
ease the sensor positioning are available
(please refer to the general catalogue). C
The operating distance is measured 3. Setting and control
from the front surface of the sensor Rotate trimmer in a clockwise direction until the yellow LED and green LED Rotate trimmer in an anticlockwise direction until the indicator reaches
The delay adjustment is carried-out manually using the Timer adjustment
optics. turn ON. Object detection condition (A status of position indicator) an intermediate point between position A and C.
trimmer. Clockwise rotation increase the delay from 0 to a max. 1 sec. value.
The M12 connector can be oriented at two different positions using the
specific fastening spring and rotating the block of 180°.

CONNECTIONS
S62-PA-2/5…PN If position A and C are close to each other, leave trimmer on position C.
A
The sensor is now ready to function correctly and in stable conditions:
2. Background suppression
The sensors are NOT safety devices, and so MUST NOT be used in the safety control of the machines
Remove object and ensure that the background is in front of the sensor: where installed.
yellow LED OFF and green LED ON.

Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
DETECTION DIAGRAM Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
S62-PA-2…PP/NN
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.

The warranty period for this product is 36 months. See General Terms and Conditions of Sales for
further details.
Rotate trimmer in a clockwise direction until the yellow LED and green LED
turn ON: background detection condition (B status of position indicator). Under current Italian and European laws, Datalogic is not obliged to take care of product
disposal at the end of its life. Datalogic recommends disposing of the product in compliance with
local laws or contacting authorised waste collection centres.

S62-PA-5…PP/NN (M12 connector) © 2007 - 2017 Datalogic S.p.A. and/or its affiliates  ALL RIGHTS RESERVED.  Without limiting the
rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a
retrieval system, or transmitted in any form or by any means, or for any purpose, without the express
written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks
B and brands are property of their respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
The trimmer reaches maximum level with yellow LED OFF if the background
is outside the operating range. 826002875 Rev. G

You might also like