0% found this document useful (0 votes)
147 views30 pages

KCG057QV1DB G00 Kyocera

1. This document provides specifications for a Kyocera LCD module intended for use in electronic devices like audio and office equipment, not medical applications, as module failure could harm users. 2. The customer must indemnify Kyocera for any issues arising from use of the module in medical applications, which Kyocera expressly disclaims support for. 3. Kyocera reserves the right to destroy tooling for modules if no purchase orders are received for two years, which the customer acknowledges.

Uploaded by

rodrigootavio5
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
147 views30 pages

KCG057QV1DB G00 Kyocera

1. This document provides specifications for a Kyocera LCD module intended for use in electronic devices like audio and office equipment, not medical applications, as module failure could harm users. 2. The customer must indemnify Kyocera for any issues arising from use of the module in medical applications, which Kyocera expressly disclaims support for. 3. Kyocera reserves the right to destroy tooling for modules if no purchase orders are received for two years, which the customer acknowledges.

Uploaded by

rodrigootavio5
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 30

Caution

1. This Kyocera LCD module has been specifically designed for use only
in electronic devices in the areas of audio control, office automation,
industrial control, home appliances, etc. The modules should not be
used in medical applications where module failure could result in
physical harm or loss of life, and Kyocera expressly disclaims any and
all liability relating in any way to the use of the module in such
medical applications.

2. Customer agrees to indemnify, defend and hold Kyocera harmless from


and against any and all actions, claims, losses, damages, liabilities,
awards, costs, and expenses, including legal fees, resulting from or
arising out of Customer's use, or sale for use, of Kyocera modules in
medical applications.

3. Kyocera shall have the right, which Customer hereby acknowledges, to


immediately scrap or destroy tooling for Kyocera modules for which no
Purchase Orders have been received from the Customer in a two-year
period.
Revision Record

Designed by: Engineering Dept. Confirmed by: QA Dept.


Date
Prepared Checked Approved Checked Approved

Rev. No. Date Page Descriptions


1. Application

This data sheet defines the specification for a (320×R.G.B)×240 dot, STN Transmissive color
dot matrix type Liquid Crystal Display with CFL backlight.

2. Construction and Outline

(320×R.G.B)×240 dots, COG type LCD with CFL backlight.

Backlight system : CFL (1tube).

Inverter : Option
Recommended Inverter : PH-BLC08-K2 (HITACHI MEDIA ELECTRONICS)
PH-BLC08-K3 ( 〃 )
or equivalent.

Polarizer : Glare treatment.

Additional circuit : Bias voltage circuit, Randomizing circuit, DC/DC Converter

Polaizer
Glass Backlight case
Color Filter

R G B R G B R G B R G B

Driver IC

CFL
Diffuser
FPC
Interface connector PCB

This drawing is showing conception only.

- 1 -
3. Mechanical Specifications

ITEM SPECIFICATION UNIT

Outline dimensions 144.0 (W) × 104.8 (H) × 12.7 (D) mm

Effective viewing area 117.2 (W) × 88.4 (H) mm

Dot number (320×R.G.B) (W) × 240 (H) Dots

Dot size 0.10 (W) × 0.34 (H) mm

Dot pitch 0.12 (W) × 0.36 (H) mm

Display color *1 White *2 -

Base color *1 Black *2 -

Mass 175 g

*1 Due to the characteristics of the LC material, the color vary with environmental temperature.

*2 Negative-type display
Display data "H" :R.G.B Dots ON : White
Display data "L" :R.G.B Dots OFF : Black

4. Absolute Maximum Ratings

4-1. Electrical absolute maximum ratings

ITEM SYMBOL MIN. MAX. UNIT

Supply voltage for logic VDD 0 6.0 V

Supply voltage for LCD driving VCONT 0 VDD V

Input signal voltage *1 Vin 0 VDD V

FRM freguency fFRM - 150 Hz

*1 Input signal : CP, LOAD, FRM, DISP, D0~D7

- 2 -
4-2. Environmental absolute maximum ratings

ITEM SYMBOL MIN MAX UNIT

Operating temperature *1 Top 0 60 ℃

Storage temperature *2 TSTO -20 60 ℃

Operating humidity *3 Hop 10 *4 %RH

Storage humidity *3 HSTO 10 *4 %RH

Vibration - *5 *5 -

Shock - *6 *6 -

*1 LCD's display quality shall not be guaranteed at the temperature range of :


below 0℃ and upper 40℃.

*2 Temp. = -20℃ < 48 h , Temp = 60℃ < 168 h


Store LCD panel at normal temperature/humidity.
Keep it free from vibration and shock.
LCD panel that is kept at low or high temperature for a long time can be defective due to
the other conditions, even if the temperature satisfies standard.

*3 Non-condensation.

*4 Temp. ≦ 40℃, 85% RH Max.


Temp. > 40℃, Absolute Humidity shall be less than 85%RH at 40℃.

*5
Frequency 10~55 Hz Converted to
acceleration value :
Vibration width 0.15 mm (0.3~9 m/s2)

Interval 10-55-10 Hz 1 minute

2 hours in each direction X/Y/Z (6 hours as total)


EIAJ ED-2531

*6 Acceleration: 490m/s2
Pulse width : 11 ms
3 times in each direction : ±X/±Y/±Z.
EIAJ ED-2531

- 3 -
5. Electrical Characteristics
Temp. = 25℃, VDD = +5.0V ± 5%

ITEM SYMBOL CONDITION MIN. TYP. MAX. UNIT


Supply voltage for logic VDD - 4.75 5.00 5.25 V
LCD driving voltage *1 Vop= 0 ℃ (1.20) - - V
VCONT
25 ℃ (1.30) (1.80) (2.30) V
60 ℃ - - (2.40) V
Input voltage Vin "H" level 0.8VDD - VDD V
(FRM,LOAD,CP,DISP,D0~D7)
"L" level 0 - 0.2VDD V
Input current Iin Input signal (-100) - (100) μA
Rush current for logic Irush When rush 3.0A(Peak) × 1ms
current happens
Clock frequency fcp - 2.02 2.16 7.14 MHz
Frame frequency *2 fFRM - 70 75 150 Hz
Current consumption IDD - 27.0 40.5 mA
for logic *3
Power consumption Pdisp - 135.0 202.5 mW

*1 Maximum contrast ratio is obtained by adjusting the LCD supply voltage ( Vop= VCONT ) for
driving LCD.

*2 In consideration of display quality, it is recommended that frame frequency is set in the range
of 70-80Hz. When you have to use higher frame and clock frequencies, confirm the LCD's performan
-ce and quality prior to finalizing the frequency values:
Generally, as frame and clock frequencies become higher current consumption will get bigger and
display quality will be degraded.

*3 Display high frequency pattern, ( see below ).


VDD = 5.0V , Vop = VCONT , fFRM = 75 Hz , fcp = 2.16MHz, Temp = 25℃
Pattern:
1 2 3 4 5 6 960(dot)


■□■□■□■□■□■□■□■□■□■□

□■□■□■□■□■□■□■□■□■□■

■□■□■□■□■□■□■□■□■□■□
: □■□■□■□■□■□■□■□■□■□■
: ■□■□■□■□■□■□■□■□■□■□
239 □■□■□■□■□■□■□■□■□■□■
240 ■□■□■□■□■□■□■□■□■□■□
(dot)

- 4 -
5. Electrical Characteristics
Temp. = 25℃, VDD = +3.3V ± 0.3V

ITEM SYMBOL CONDITION MIN. TYP. MAX. UNIT


Supply voltage for logic VDD - 3.0 3.3 3.6 V
LCD driving voltage *1 Vop= 0 ℃ (1.20) - - V
VCONT
25 ℃ (1.30) (1.80) (2.30) V
60 ℃ - - (2.40) V
Input voltage Vin "H" level 0.8VDD - VDD V
(FRM,LOAD,CP,DISP,D0~D7)
"L" level 0 - 0.2VDD V
Input current Iin Input signal (-100) - (100) μA
Rush current for logic Irush When rush 3.0A(Peak) × 1ms
current happens
Clock frequency fcp - 2.02 2.16 5.88 MHz
Frame frequency *2 fFRM - 70 75 150 Hz
Current consumption IDD - 40.5 60.8 mA
for logic *3
Power consumption Pdisp - 133.7 200.6 mW

*1 Maximum contrast ratio is obtained by adjusting the LCD supply voltage ( Vop= VCONT ) for
driving LCD.

*2 In consideration of display quality, it is recommended that frame frequency is set in the range
of 70-80Hz. When you have to use higher frame and clock frequencies, confirm the LCD's performan
-ce and quality prior to finalizing the frequency values:
Generally, as frame and clock frequencies become higher current consumption will get bigger and
display quality will be degraded.

*3 Display high frequency pattern, ( see below ).


VDD = 3.3V , Vop = VCONT , fFRM = 75 Hz , fcp = 2.16MHz, Temp = 25℃
Pattern:
1 2 3 4 5 6 960(dot)


■□■□■□■□■□■□■□■□■□■□

□■□■□■□■□■□■□■□■□■□■

■□■□■□■□■□■□■□■□■□■□
: □■□■□■□■□■□■□■□■□■□■
: ■□■□■□■□■□■□■□■□■□■□
239 □■□■□■□■□■□■□■□■□■□■
240 ■□■□■□■□■□■□■□■□■□■□
(dot)

- 5 -
6.Optical Characteristics

Temp. = 25℃

ITEM SYMBOL CONDITION MIN. TYP. MAX. UNIT

Response Rise Tr θ=φ=0° - 190 290 ms


time
Down Td θ=φ=0° - 170 270 ms

Viewing angle range θ φ=0゜ -35 - 20 deg.


CR≧2
φ θ=0゜ -50 - 50 deg.

Contrast ratio CR θ=φ=0° (30) (55) - -

Brightness(IL=5.0mA) L - (110) (160) - cd/m2

Chromaticity Red x 0.49 0.54 0.59


coordinates θ=φ=0°
y 0.28 0.33 0.38

Green x 0.24 0.29 0.34


θ=φ=0°
y 0.46 0.51 0.56

Blue x 0.10 0.15 0.20


θ=φ=0° -
y 0.07 0.12 0.17

White x 0.25 0.30 0.35


θ=φ=0°
y 0.25 0.30 0.35

Optimum contrast is obtained by adjusting the LCD driving voltage(Vop) while at the viewing angle
of θ = φ = 0°.

6-1. Contrast ratio is defined as follows:

Brightness at all pixels "White"


CR =
Brightness at all pixels "Black"

- 6 -
6-2. Definition of Vop

Contrast

CR max

VCONT (V)
Vop

6-3. Definition of response time

- 7 -
6-4. Definition of viewing angle

φ=0 ° θ=0°

+Y -θ +Y


-X +X -X +X

-Y -Y

( θ direction ) ( φ direction )

6-5. Measuring points

80×3 160×3 240×3 (dot)

1 4
60 ○ ○
3
120 ○
2 5
180 ○ ○

(dot)

1) Rating is defined as the average brightness inside the viewing area.

2) 30 minutes after CFL is turned on. (Ambient Temp.=25℃)

3) The inverter should meet the eccentric conditions;


-Sine, symmetric waveform without spike in positive and negative.

- 8 -
INVERTER

D0~D7
CP

VSS
VSS = V1
7. Circuit Block Diagram

DISP
DF SEG Driver IC

LOAD Randomizing
circuit

- 9 -
FRM COM (320 × R. G. B) × 240 LCD
Driver IC
V0 1/240 duty
VDD To SEG IC
DC / DC To SEG IC
VM
VCONT converter VH
DISP VL
7-1. Power supply

VCONT

Vop
KCG057QV1D
(+1.2V~2.4V)
+3.3V VDD
or5.0V

VSS

- 10 -
8. Interface signals

8-1. LCD

PIN NO. SYMBOL DESCRIPTION LEVEL


1 FRM Synchronous signal for driving scanning line H
2 LOAD Data signal latch clock H → L
3 CP Data signal shift clock H → L
4 DISP Display control signal H(ON),L(OFF)
5 VDD Power supply for logic ―
6 VSS GND ―
7 VCONT LCD adjust voltage ―
8 D7
9 D6
10 D5
11 D4 Display data H(ON),L(OFF)
12 D3
13 D2
14 D1
15 D0
16 VDD Power supply for logic -
17 VDD
18 VSS GND
19 VSS -
20 VSS

LCD connector : 08-6210-020-340-800 (ELCO)


Recommended matching connector : 0.5mm pitch FFC or FPC

8-2. CFL

PIN No SYMBOL DESCRIPTION LEVEL


1 HV Power supply for CFL AC
2 NC ― ―
3 GND Ground line(from inverter) ―

LCD side connector : BHR-03VS-1 (JST)


Recommended matching connector : SM02-(8.0)B-BHS-1 (JST)

- 11 -
9.Interface Timing Chart

LOAD

CP

D7 G318 R1 B3 G318 R1

D6 B318 G1 R4 B318 G1

D5 R319 B1 G4 R319 B1

D4 G319 R2 B4 G319 R2

D3 B319 G2 R5 B319 G2

D2 R320 B2 G5 R320 B2

D1 G320 R3 B5 G320 R3

D0 B320 G3 R6 B320 G3

FRM
CP × (320×R.G.B) / 8 pulse

LOAD

×1 ×2 ×240 ×1

D0~D7

FRM

* The cycle of load signal should be stable and continuously applied without interruption.

* The above-mentioned timing chart shows a reference to set up a LCD module, not an electrical
rating.

- 12 -
10.Data and Screen

CHIP AREA

Y1 Y2 Y3 ・・・ Y320
C X1
H D7 D6 D5 D4 D3 D2 D1 D0 D7 D2 D1 D0
I R1 G1 B1 R2 G2 B2 R3 G3 B3 R320 G320 B320
P

A
R
E
A
X240

- 13 -
11. Input Timing Characteristics

trCP tfCP
tWCLH tWCLL tCCL

CP

tDS tDH
DATA

tCDLD

CP

last 1st 1st


tLDCR
tWLPH
tLCL

LOAD

tWLPL
tr tf

tFS tFH
FRM

- 14 -
11-1. Switchig characteristics

Input Characteristics ; VDD = +5.0V ± 5%, Temp. = 25 ℃

ITEM SYMBOL MIN. MAX. UNIT

CP Cycle *1,*2 tCCL 140 - ns

CP "H" Pulse Width *2 tWCLH 60 - ns

CP "L" Pulse Width *2 tWCLL 60 - ns

CP Rise Up Time *2 trCP - 15 ns

CP Fall Down Time *2 tfCP - 15 ns

Data Set Up Time tDS 30 - ns

Data Hold Time tDH 30 - ns

LOAD "H" Pulse Width tWLPH 60 - ns

LOAD "L" Pulse Width tWLPL 400 - ns

LOAD Cycle *3 tLCL 500 - ns

CP Down→LOAD Down Dalay Time tCDLD 100 - ns

LOAD Down→CP Rise Dalay Time *4 tLDCR 100 - ns

Input Signal Rise Up Time tr - 20 ns

Input Signal Fall Down Time tf - 20 ns

FRM Data Set Up Time tFS 120 - ns

FRM Data Hold Time tFH 30 - ns

*1 CP Cycle is adjust so that FRM signal is 75Hz.

*2 The formula of condition


① trCP + tfCP < tCCL - (tWCLH + tWCLL)
② trCP,tfCP ≦ 15 ns
Please use on condition that ①,② are filled.

*3 LOAD Cycle is const.

- 15 -
11-2. Switchig characteristics

Input Characteristics ; VDD = +3.3V ± 0.3V, Temp. = 25 ℃

ITEM SYMBOL MIN. MAX. UNIT

CP Cycle *1,*2 tCCL 170 - ns

CP "H" Pulse Width *2 tWCLH 80 - ns

CP "L" Pulse Width *2 tWCLL 80 - ns

CP Rise Up Time *2 trCP - 20 ns

CP Fall Down Time *2 tfCP - 20 ns

Data Set Up Time tDS 60 - ns

Data Hold Time tDH 60 - ns

LOAD "H" Pulse Width tWLPH 80 - ns

LOAD "L" Pulse Width tWLPL 400 - ns

LOAD Cycle *3 tLCL 500 - ns

CP Down→LOAD Down Dalay Time tCDLD 100 - ns

LOAD Down→CP Rise Dalay Time *4 tLDCR 100 - ns

Input Signal Rise Up Time tr - 20 ns

Input Signal Fall Down Time tf - 20 ns

FRM Data Set Up Time tFS 120 - ns

FRM Data Hold Time tFH 30 - ns

*1 CP Cycle is adjust so that FRM signal is 75Hz.

*2 The formula of condition


① trCP + tfCP < tCCL - (tWCLH + tWCLL)
② trCP,tfCP ≦ 20 ns
Please use on condition that ①,② are filled.

*3 LOAD Cycle is const.

- 16 -
12. Supply Voltage Sequence Condition

DO NOT apply DC voltage to the LCD panel. DC voltage induce irreversible electrochemical
reactions and reduce LCD life. Always follow the power supply ON/OFF sequence of VDD first,
input signal second, VCONT third and finally DISP. This will prevent DC driving of the LCD or
CMOS LSI latch up as shown below.

VDD

0ms MIN 0ms MIN

Input signal
VCONT

0ms MIN 0ms MIN

DISP

* Input signal : CP,LOAD,FRM,VCONT,D0~D7

* The above sequence should be designed as to keep each normal figure on condition that liquid
crystal module is loaded on your system.

* Control the input signal and VCONT to the above ON - OFF timing when you switch ON/OFF the
display during VDD and DISP are on.
And design the circuit as VCONT's OFF level become GND level at the some time.

- 17 -
13. Backlight Characteristics

Temp.= 25℃

ITEM SYMBOL MIN. TYP. MAX. NOTE


Starting - - (795) Vrms. 0 ℃
discharge Voltage VS
*1 - - (530) Vrms. 25 ℃
Discharging tube current *2,*3 IL 3.0 mArms. 5.0 mArms. 6.0 mArms. -
Discharging tube voltage VL - (320) Vrms. - -
Operating life *4 T 36,000 h 54,000 h - -
(IL=5.0 mArms.)
Operating frequency F (40) kHz - (100) kHz -

*1 The Non-load output voltage (VS) of the inverter should be designed to have some margin,
because VS may increase due to the leak current which may be caused by wiring of CFL cables.
(Reference value: (1035) Vrms MIN.)

*2 We recommend that you should set the discharging tube current at lower than typical value
so as to prevent the heat accumulation of CFL tube from deteriorating a performance of the LCD.

*3 Do not apply more than 6.0mA discharge tube current. Because CFL maybe broken due to over
current.

*4 When the illuminance or quantity of light has decreased to 50 % of the initial value.
Average life time of CFL will be decreased when LCD is operating at lower and Higher temperature.

- 18 -
14.Lot Number Identification

The lot number shall be indicated on the back of the backlight case of each LCD.

KCG057QV1DB-G00- □ □-□ □

DATE
MONTH
YEAR

YEAR 2002 2003 2004 2005 2006 2007

CODE 2 3 4 5 6 7

MONTH JAN. FEB. MAR. APR. MAY JUN.

CODE 1 2 3 4 5 6

MONTH JUL. AUG. SEP. OCT. NOV. DEC.

CODE 7 8 9 X Y Z

15.Warranty

15-1. Incoming inspection

Please inspect the LCD within one month after your receipt.

15-2. Production Warranty

Kyocera warrants its LCDs for a period of 12 months after receipt by the purchaser, and within
the limits specified. Kyocera shall, by mutual agreement, replace or rework defective LCDs
that are shown to be Kyocera's responsibility.

- 19 -
16.Precautions for use

16-1. Installation of the LCD


1. Please ground the mounting (screw) holes of an LCD module, in order to stabilize brightness
and display quality.
2. A transparent protection plate shall be added to protect the LCD and its polarizers.
3. The LCD shall be installed so that there is no pressure on the LSI chips.
4. The LCD shall be installed flat, without twisting or bending.
5. The display window size should be the same as the effective viewing area.
6. In case you use outside frame of effective viewing area as outward appearance of your product,
unevenness of its outward appearance is out of guarantee.
7. Do not pull the CFL lead wires and do not bend the root of the wires.
Housing should be designed to protect CFL lead wires from external stress.

16-2. Static Electricity


1. Since CMOS ICs are mounted directly onto the LCD glass, protection from static electricity is
required. Operation should wear ground straps.

16-3. LCD Operation


1. The LCD shall be operated within the limits specified. Operation at values outside of these
limits may shorten life, and/or harm display images.
2. Vop must be adjusted to optimize viewing angle and contrast.
3. Operation of the LCD at temperature below the limit specified may cause image degradation
and/or bubbles.
It may also change the characteristics of the liquid crystal.
This phenomenon may not recover. The LCD shall be operated within the temperature limits
specified.

16-4. Storage
1. The LCD shall be stored within the temperature and humidity limits specified.
Store in a dark area, and protected the LCD from direct sunlight or fluorescent light.
2. The LCD should be packaged to prevent damage.

16-5. Screen Surface


1. DO NOT store in a high humidity environment for extended periods.
Image degradation, bubbles, and/or peeling off of polarizer may result.
2. The front polarizer is easily scratched or damaged.
Prevent touching it with any hard material, and from being pushed or rubbed.
3. The LCD screen may be cleaned with a soft cloth or cotton pad.
Methanol, or Isopropyl Alcohol may be used, but insure that all solvent residue is removed.
4. Water may cause damage or discoloration of the polarizer.
Clean any condensation or moisture from any source immediately.
5. Always keep the LCD free from condensation during testing.
Condensation may permanently spot or stain the polarizers.

- 20 -
17.Reliability Data / Environmental Test

TEST TEST TEST RESULT


ITEM CONDITION TIME

High Temp. 60℃ 240 h Display Quality : No defect


Atmosphere Display Function : No defect
Current Consumption : No defect

Low Temp. Bubble : None


Solid Crystallization of
Low Temp. -20℃ 240 h Liquid Crystal : None
Atmosphere Display Quality : No defect
Display Function : No defect
Current Consumption : No defect

Display Quality : No defect


High Temp. 40℃ 240 h Display Function : No defect
Humidity 90%RH Peel-off of Organic
Atmosphere Sealing : None
Current Consumption : No defect

Display Quality : No defect


Temp. Cycle -20℃ 0.5 h 10 cycles Display Function : No defect
R.T. 0.5 h Peel-off of Organic
60℃ 0.5 h Sealing : None
Bubble on Cell : None

High Temp. 60℃ 500 h Display Quality : No defect


Operation Vop Current Consumption : No defect

* Each test item uses a test LCD only once. The tested LCD is not used in any other tests.

* The LCD is tested in circumstances in which there is no condensation.

* The tested LCD is inspected after 24 hours of storage at room temperature and room humidity
after each test is finished.

* The reliability test is not an out-going inspection.

* The result of the reliability test are for your reference purpose only.
The reliability test is conducted only to examine the LCD's capability.

- 21 -
Revision Record

Designed by: Engineering Dept. Confirmed by: QA Dept.


Date
Prepared Checked Approved Checked Approved

Rev. No. Date Page Descriptions


Visuals specification
1)Note

Item Note

General 1.When defects specified in this Inspection Standards are


inspected, operating voltage(Vop) shall be set at the
level where optimized contrast is available.
Display quality is applied up to effective viewing area.
(Bi-Level INSPECTION)

2.This inspection standard about the image quality shall be


applied to any defect within the effective viewing area
and shall not be applicable to outside of the area.

3.Should any defects which are not specified in this


standard happen, additional standard shall be determined
by mutual agreement between customer and Kyocera.

4.Inspection conditions

Luminance : 500 Lux minimum .


Inspection distance : 300 mm (from the sample)
Temperature : 25 ± 5 ℃
Direction : right above

Definition of Inspection Pinhole, Bright spot The color of a small area is


item Black spot, Scratch different from the remainder.
Foreign particle The phenomenon does not change
with voltage.

Contrast variation The color of a small area is


different from the remainder.
The phenomenon changes with
voltage.

Polarizer ( Scratch, Scratch, Bubble and Dent in the


Bubble, Dent ) polarizer which can be observed
in on / off state.

- 1 -
2)Standard

Inspection item Judgement standard


Pinhole, Bright spot
Black spot,
Foreign particle


a
d = ( a + b ) / 2

Category Size (mm) Acceptable number


A d ≦ 0.2 neglected
B 0.2 < d ≦ 0.3 5
C 0.3 < d ≦ 0.5 3
D 0.5 < d 0

Scratch,Foreign particle
W

Width (mm) Length (mm) Acceptable No.


A W ≦ 0.03 neglected
B L ≦ 2.0 neglected
C 0.03< W ≦ 0.1 2.0 < L ≦ 4.0 3
D 4.0 < L 0
E 0.1 < W According to
' Circular '

Contrast variation


d = ( a + b ) / 2

Category Size (mm) Acceptable number


A d ≦ 0.5 neglected
B 0.5 < d ≦ 0.7 3
C 0.7 < d 0

- 2 -
Inspection item Judgement standard

Polarizer ( Scratch, (1) Scratch W


Bubble, Dent )

Width (mm) Length (mm) Acceptable No.

A W ≦ 0.1 neglected

B L ≦ 5.0 neglected
0.1 < W ≦ 0.3
C 5.0 < L 0

D 0.3 < W 0

(2)Bubble ( dent )

d = ( a + b ) / 2

Category Size (mm) Acceptable number

A d ≦ 0.2 neglected

B 0.2 < d ≦ 0.3 5

C 0.3 < d ≦ 0.5 3

D 0.5 < d 0

- 3 -

You might also like