0% found this document useful (0 votes)
97 views18 pages

Photovoltaic Module Test Report

This technical report provides test results for Shanghai JA Solar Technology Co., Ltd. It lists 19 manufacturing places that were tested, including locations in China, Vietnam, Jordan, and elsewhere. The report details the client, various production facilities that were examined, and refers to test results.

Uploaded by

Praveen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views18 pages

Photovoltaic Module Test Report

This technical report provides test results for Shanghai JA Solar Technology Co., Ltd. It lists 19 manufacturing places that were tested, including locations in China, Vietnam, Jordan, and elsewhere. The report details the client, various production facilities that were examined, and refers to test results.

Uploaded by

Praveen
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 18

Technical Report

Test Report No.704062000682-00


Dated 2020-06-19

Client: Shanghai JA Solar Technology Co., Ltd.


No. 118, Lane 3111, West Huancheng Road, Fengxian District,
201401, Shanghai, PEOPLE'S REPUBLIC of CHINA
Contact person: Mr. Wang yongbo

Manufacturing: place: 1. Shanghai JA Solar Technology Co., Ltd. (Production fa-


cility No. in certificate: 72092)
No. 118, Lane 3111, West Huancheng Road, Fengxian Dis-
trict, 201401, Shanghai, PEOPLE'S REPUBLIC of CHINA
2.Hefei JA Solar Technology Co., Ltd (Production facility
No. in certificate: 79395)
No. 999, Changning Road, Hi-tech Zone, 230088 Hefei
City, Anhui Province, PEOPLE'S REPUBLIC of CHINA
3. JA SOLAR CO., LTD. (Production facility No. in certifi-
cate: 72056)
Jinglong Street, Ningjin County, 055550 Xingtai, Hebei,
PEOPLE'S REPUBLIC OF CHINA
4. Vina Solar Technology Co., Ltd (Production facility No. in
certificate: 90968)
E12 factory, lot CN-03, Van Trung Industrial park, 21000
Doc No.:ITC-TTW0902.02E - Rev.7

Bac Giang Province, Vietnam


5. JA Solar (Xingtai) Co., Ltd (Production facility No. in cer-
tificate: 95903)
No. 1688, Chang An Road, Xingtai Economic Development
Area, Xingtai City, Hebei Province, PEOPLE'S REPUBLIC
OF CHINA
6.Philadelphia Solar LTD. CO (Production facility No. in cer-
tificate: 101572)
Al Qastal Industrial Area, Air freight Road, 11814 Amman,
JORDAN
7.Dongying Dahai Kelin Solar Power Co., Ltd (Production
facility No. in certificate: 01783)
Yankou Village, Daozhuang Town, Guangrao County,
257336 Dongying City, Shandong Province,PEOPLE'S RE-
PUBLIC OF CHINA
8.Laiwu Cleo Solar Power Co., Ltd. (Production facility No.
in certificate: 102852)
Room 101, No. 7 Zhenxing Road, Economic Development
Report No.:704062000682 www.tuvsud.com
Rev.: 00
Date: 2020-06-19

Page 1 of 18
Technical Report

Zone 271100 Laiwu, Shandong, PEOPLE'S REPUBLIC OF


CHINA
9.DAS SOLAR CO., LTD. (Production facility No. in certifi-
cate: 102627)
No. 43, South of Bailing Rd, Quzhou Green Industry Cluster-
ing Zone, 324000 Quzhou, Zhejiang Province,PEOPLE'S
REPUBLIC OF CHINA
10.Green Intelligent Photovoltaic Nantong Co., LTD. (Pro-
duction facility No. in certificate: 104756)
Haiyue Road No.1, Sutong Technology Industry Park
226000 Nantong, Jiangsu PEOPLE'S REPUBLIC OF CHI-
NA
11.Henan huayi new energy technology Co. LTD (Produc-
tion facility No. in certificate: 104757)
No.369, qianjin avenue, yicheng district, 463000 zhumadian
city, henan province, PEOPLE'S REPUBLIC OF CHINA
12.Tongwei Solar (Hefei) Co., Ltd. (Production facility No. in
certificate: 090075)
No. 888 Changning Road High-tech District 230088 Hefei,
Anhui PEOPLE'S REPUBLIC OF CHINA
13.Tangshan Haitai New Energy Technology Co., Ltd. (Pro-
duction facility No. in certificate: 078666)
No. 88 Haomen road, Yutai industrial zone, Yutian 064100
Tangshan, Hebei PEOPLE'S REPUBLIC OF CHINA
14.Hengdian Group DMEGC Magnetics CO., LTD (Produc-
Doc No.:ITC-TTW0902.02E - Rev.7

tion facility No. in certificate: 076053)


Hengdian Industrial Zone, Dongyang 322118, Zhejiang,
China
15.Econess Energy Co., Ltd. (Production facility No. in cer-
tificate: 078439)
No.58 Haida Road Huashi Town 214421 Jiang Yin, Jiangsu
Province People's Republic of Chi-
na
16.YONZ PV. OEM (ChangZhou) Co., LTD (Production fa-
cility No. in certificate: 104704)
No.99 Yuehu North Road Jintan District 213200 Chang-
zhou, Jiangsu PEOPLE'S REPUBLIC OF CHINA
17.Xuzhou Jiayu Solar Energy Technology Co., Ltd. (Pro-
duction facility No. in certificate: 105721)
North of Peigong Road, East of Hankang Road, Peixian
Economic Development Zone, 221699 Xuzhou, Jiangsu,
People's Republic of China
Report No.:704062000682 www.tuvsud.com
Rev.: 00
Date: 2020-06-19

Page 2 of 18
Technical Report

18. Funing GCL System Integration Technology Co., Ltd.


(Production facility No. in certificate: 105673)
No.888(A) Hong Kong Road, Funing Ecnomic Development
Zone Yancheng City, Jiangsu Province,PEOPLE'S REPUB-
LIC OF CHINA
19. BaoDing Lightway Green Energy Technology Co., Ltd.
(Production facility No. in certificate: 082738)
Gaobeidian New Industry Park 074000 Gaobeidian, Hebei
Province PEOPLE'S REPUBLIC OF CHINA
20. Jiangsu Chuangji Renewable Energy Co., Ltd. (Produc-
tion facility No. in certificate: 102160)
No. 35 Jiangong Rd., Nanfeng Town Zhangjiagang, Jiangsu
Province,PEOPLE'S REPUBLIC OF CHINA
21. Anhui Dongsheng New Energy Co., Ltd. (Production
facility No. in certificate: 104585)
No.11 Plant, Optical-Mechanical-Electrical Agglomeration
Area, Guoyang County, 233600 Bozhou, Anhui, PEOPLE'S
REPUBLIC OF CHINA
22. Jurong GCL System Integration Technology Co., Ltd.
(Production facility No. in certificate: 105674)
No.999 Konggang New District, Guozhuang Town, 212400
Jurong City, PEOPLE'S REPUBLIC OF CHINA
23. Changzhou Almaden Co., Ltd (Production facility No. in
certificate: 084671)
639, Qinglong East Road, 213000 Changzhou, Jiangsu,
Doc No.:ITC-TTW0902.02E - Rev.7

PEOPLE'S REPUBLIC OF CHINA


24. GK Solar Power Co., Ltd. (Production facility No. in cer-
tificate: 096716)
Yiyuan Economic Development Zone 256100 Zibo City,
Shandong Province PEOPLE'S REPUBLIC OF CHINA
25. Suzhou Akcome Optronics Science & Technology Co.,
Ltd. (Production facility No. in certificate: 103323)
No.110 West Jintang Road, Economic Development Zone,
215600 Zhangjiagang, PEOPLE'S REPUBLIC OF CHINA
26.Jetion Solar (China) Co., Ltd. (Production facility No. in
certificate: 068988)
No. 1011, Zhencheng Rd., Shengang Industrial District,
214443 Jiangyin, PEOPLE'S REPUBLIC OF CHINA

27.Junfeng Solar (jiangsu) Co., Ltd. (Production facility No.


in certificate: 079922)
No. 20, 21 Group, Tangang Village, Haian Industry Park,
Report No.:704062000682 www.tuvsud.com
Rev.: 00
Date: 2020-06-19

Page 3 of 18
Technical Report

226600, Haian, Jiangsu, PEOPLE'S REPUBLIC OF CHINA


28. Jiangsu Jinko Day Sheng Solar Co., Ltd. (Production
facility No. in certificate: 108228)
No. 228 Yuesheng North Road, Industry Center, Fanshui
Town, Baoying County, 225819 Yangzhou City, Jiangsu
Province, PEOPLE'S REPUBLIC OF CHINA

Test subject: Product: Photovoltaic modules

Test specification: IEC 61853-1:2011


IEC 61853-2:2016
IEC 60891:2009

Purpose of examination: PAN File Parameters Determination

Test result: The test results for the present samples are show in clause3
Doc No.:ITC-TTW0902.02E - Rev.7

Any use for advertising purposes must be granted in writing. This technical report may only be quoted in full. This report is the
result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in
regular production. For further details please see testing and certification regulation, chapter A-3.4.

Report No.:704062000682 www.tuvsud.com


Rev.: 00
Date: 2020-06-19

Page 4 of 18
Technical Report

1 Description of the test subject

1.1 Function

Manufacturer’s specification for intended use:

The PV modules for electricity generation systems with max. voltage of 1500 V DC

Manufacturer’s specification for predictive use:


N/A

1.2 Consideration of the foreseeable use

Not applicable
Covered through the applied standard
Covered by the following comment
Covered by attached risk analysis

1.3 Technical Data

Type or model number JAM72S10-405/MR


Doc No.: ITC-TTW0902.02E - Rev.7

Voc (Vdc) 49.86±2%


Vmp (Vdc) 41.60
Isc (Adc) 10.39±4%
Imp (Adc) 9.74
Pmp (W) 405±3%
Bifaciality factor, if bi-facial
N/A
module
Maximum system voltage (V) 1500
Maximum over-current protec-
20
tion rating (A)
Safety Class Class II

2 Order

2.1 Date of Purchase Order, Customer’s Reference


Report No.:704062000682 www.tuvsud.com
Rev.: 00
Date: 2020-06-19

Page 5 of 18
Technical Report

2020-06-03

2.2 Receipt of Test Sample, Location

Changzhou HuaYang Inspection and Testing Technology Co., Ltd.

2.3 Date of Testing

2020-06-09 to 2020-06-16

2.4 Location of Testing

Changzhou HuaYang Inspection and Testing Technology Co., Ltd.

2.5 Points of Non-compliance or Exceptions of the Test Procedure

N/A

3 Test Results

3.1 Sample Information

Sample # Model Sample S/N Remark


Doc No.: ITC-TTW0902.02E - Rev.7

HA2020TL-354-
JAM72S10-405/MR 205M6M7210000019 61853-1
001X
HA2020TL-354-
JAM72S10-405/MR 205M6M7210000018 61853-1
002X
HA2020TL-354-
JAM72S10-405/MR 205M6M7210000020 61853-1
003X
HA2020TL-354-
Special samples — 61853-2
004X

3.2 Flash Tests According to Table 2 of the IEC 61853-1

To determine the relationship between efficiency and irradiance & temperature, PV modules are
tested across a matrix of operating conditions according to the standard IEC 61853-1:2011,
ranging in irradiance from 100 W/m2 to 1100 W/m2 and ranging in temperature from 15 °C to 75
°C.
To determine the temperature coefficients, PV modules are tested according to IEC 60891:2009,
under irradiance 1000W/m2 and ranging in temperature from 25 °C to 55 °C.
Based on the laboratory measurement data, PAN file can be optimized, then match ability be-
tween the resulting efficiencies in PVsyst software and the lab data can be compared.

Report No.:704062000682 www.tuvsud.com


Rev.: 00
Date: 2020-06-19

Page 6 of 18
Technical Report

3.3 Raw Data

TABLE 2:
Flash test data for each sample at the real irradiance and temperature conditions in table 2 of the
IEC 61853-1
Sampe1, Serial Number 205M6M7210000019

TTARGET IRRTARGET TACHIVED IRRACHIVED


Voc [V] Vmp [V] Isc [A] Imp [A] Pmp [W] FF [%]
[ºC] [W/m2] [ºC] [W/m2]

15 100 15.1 101.3 46.137 39.443 1.145 1.034 40.788 77.21


15 200 15.1 200.1 47.476 40.702 2.103 2.018 82.153 82.28
15 400 15.2 400.1 48.741 41.455 4.325 4.033 167.188 79.31
15 600 15.1 601.2 49.495 41.788 6.306 6.031 252.008 80.74
15 800 15.0 799.6 49.970 41.727 8.462 8.021 334.694 79.15
15 1000 15.1 1001.9 50.480 41.716 10.615 10.023 418.107 78.03

25 100 25.0 100.7 44.504 37.921 1.090 1.023 38.811 80.01


25 200 24.9 199.9 45.895 39.014 2.141 2.020 78.817 80.22
25 400 25.0 400.4 47.283 40.012 4.206 4.023 160.974 80.94
25 600 25.1 601.8 48.050 40.194 6.382 6.037 242.651 79.13
25 800 24.9 799.4 48.634 40.198 8.526 8.058 323.915 78.12
25 1000 24.9 1002.0 49.095 40.052 10.644 10.097 404.405 77.39
25 1100 25.1 1100.5 49.241 40.102 11.801 11.070 443.940 76.40
Doc No.: ITC-TTW0902.02E - Rev.7

50 400 49.8 397.7 44.109 36.581 4.269 4.030 147.421 78.28


50 600 50.2 597.1 44.867 36.710 6.460 6.050 222.084 76.62
50 800 49.9 795.7 45.470 36.866 8.563 7.998 294.849 75.73
50 1000 49.8 1000.5 45.941 36.563 10.785 10.095 369.095 74.49
50 1100 50.0 1101.6 46.036 36.504 11.912 11.091 404.852 73.83

75 600 75.0 598.3 41.607 33.341 6.518 6.046 201.596 74.34


75 800 75.2 796.0 42.242 33.412 8.707 8.026 268.176 72.91
75 1000 75.1 995.3 42.848 33.939 10.809 9.868 334.903 72.31
75 1100 74.9 1096.2 42.894 33.220 11.975 11.052 367.155 71.48

Sampe2, Serial Number 205M6M7210000018

TTARGET IRRTARGET TACHIVED IRRACHIVED


[ºC] [W/m2] [ºC] [W/m2]
Voc [V] Vmp [V] Isc [A] Imp [A] Pmp [W] FF [%]

15 100 15.0 102.1 46.138 39.442 1.023 1.032 40.704 86.24


15 200 14.8 202.0 47.441 40.830 2.128 2.030 82.883 82.11
15 400 15.2 401.4 48.764 41.710 4.219 4.020 167.674 81.50
15 600 15.0 600.6 49.590 41.786 6.341 6.047 252.660 80.35
15 800 15.1 802.2 50.002 41.850 8.471 8.024 335.791 79.28
15 1000 15.2 1003.6 50.473 41.593 10.616 10.066 418.690 78.14

25 100 25.1 101.9 44.537 37.710 1.044 1.045 39.396 84.73


Report No.:704062000682 www.tuvsud.com
Rev.: 00
Date: 2020-06-19

Page 7 of 18
Technical Report

25 200 25.1 200.5 45.916 38.765 2.178 2.039 79.055 79.04


25 400 24.8 401.5 47.289 39.883 4.244 4.046 161.348 80.40
25 600 25.1 601.4 48.066 40.082 6.413 6.069 243.258 78.92
25 800 24.8 802.3 48.622 40.071 8.483 8.086 324.014 78.56
25 1000 24.8 1004.5 49.098 40.051 10.655 10.103 404.635 77.35
25 1100 24.9 1101.4 49.254 39.856 11.887 11.154 444.541 75.93

50 400 50.0 398.1 44.088 36.581 4.324 4.036 147.638 77.44


50 600 50.0 598.9 44.795 36.453 6.475 6.096 222.226 76.62
50 800 49.9 795.8 45.491 36.874 8.582 8.026 295.952 75.81
50 1000 50.1 999.2 45.986 36.699 10.785 10.062 369.254 74.45
50 1100 49.8 1099.0 46.189 36.766 11.854 11.050 406.275 74.20

75 600 75.1 598.1 41.728 33.469 6.522 6.043 202.236 74.31


75 800 74.8 795.1 42.383 33.551 8.689 8.021 269.119 73.07
75 1000 74.9 997.3 42.741 33.646 10.922 9.997 336.356 72.06
75 1100 75.1 1096.4 43.050 33.530 12.033 11.024 369.645 71.36

Sampe3, Serial Number 205M6M7210000020

TTARGET IRRTARGET TACHIVED IRRACHIVED


[ºC] [W/m2] [ºC] [W/m2]
Voc [V] Vmp [V] Isc [A] Imp [A] Pmp [W] FF [%]

15 100 15.1 100.7 46.164 39.643 1.155 1.023 40.555 76.06


15 200 15.0 199.8 47.417 40.571 2.077 2.015 81.749 83.00
Doc No.: ITC-TTW0902.02E - Rev.7

15 400 15.1 400.5 48.724 41.453 4.201 4.033 167.165 81.67


15 600 15.2 599.1 49.529 41.786 6.322 6.021 251.606 80.36
15 800 15.1 798.1 50.034 41.709 8.435 8.016 334.319 79.21
15 1000 14.9 1001.2 50.492 41.583 10.647 10.042 417.582 77.68

25 100 25.0 99.6 44.505 37.915 1.116 1.012 38.387 77.29


25 200 25.1 199.9 45.904 38.888 2.176 2.025 78.761 78.86
25 400 25.1 398.2 47.272 40.002 4.229 4.001 160.057 80.06
25 600 25.0 601.2 48.056 40.198 6.313 6.042 242.876 80.06
25 800 25.1 802.0 48.627 40.195 8.512 8.047 323.449 78.15
25 1000 24.9 1000.2 49.078 40.049 10.637 10.087 403.974 77.38
25 1100 24.9 1098.2 49.237 40.095 11.818 11.055 443.254 76.18

50 400 49.9 396.4 44.056 36.700 4.364 4.001 146.834 76.38


50 600 49.8 595.9 44.836 36.707 6.432 6.033 221.458 76.79
50 800 50.2 795.1 45.450 36.863 8.569 7.998 294.830 75.70
50 1000 50.0 995.9 45.964 36.688 10.751 10.014 367.408 74.35
50 1100 49.9 1097.8 46.098 36.505 11.831 11.077 404.350 74.14

75 600 74.9 596.5 41.595 33.321 6.542 6.027 200.825 73.80


75 800 74.8 796.0 42.252 33.271 8.677 8.020 266.836 72.78
75 1000 74.9 995.5 42.736 33.814 10.833 9.883 334.197 72.19
75 1100 75.2 1096.1 42.917 33.127 12.052 11.076 366.926 70.94

Report No.:704062000682 www.tuvsud.com


Rev.: 00
Date: 2020-06-19

Page 8 of 18
Technical Report

Table 3:
Temperature Coefficients Measurement Data at the 1000 W.m-2 Irradiance

TTARGET IRRTARGET TACHIVED IRRACHIVED


[ºC] [W/m2] [ºC] [W/m2]
Voc [V] Vmp [V] Isc [A] Imp [A] Pmp [W] FF [%]

25 1000 24.8 1004.5 49.098 40.051 10.655 10.103 404.635 77.35


30 1000 30.1 999.2 48.550 39.390 10.683 10.083 397.161 76.57
35 1000 35.1 998.1 47.898 38.704 10.704 10.073 389.865 76.04
40 1000 40.2 998.7 47.299 38.148 10.733 10.054 383.540 75.55
45 1000 45.0 1000.5 46.739 37.515 10.754 10.067 377.664 75.14
50 1000 50.1 999.2 45.986 36.699 10.785 10.062 369.254 74.45
55 1000 55.2 999.5 45.395 36.084 10.817 10.054 362.781 73.88

3.3.1 Test Data Analysis

3.3.1.1 Temperature Coefficients


Figure 1:
Doc No.: ITC-TTW0902.02E - Rev.7

Plot of measured PMAX, Voc vs. temperature of flash-tests taken at 1000 W/m2 for each sample

Report No.:704062000682 www.tuvsud.com


Rev.: 00
Date: 2020-06-19

Page 9 of 18
Technical Report

Figure 2:
Plot of measured Isc vs. temperature of flash-tests taken at 1000 W/m2 for each sample
Doc No.: ITC-TTW0902.02E - Rev.7

Table 4:
Average Temperature Coefficients Determined by Laboratory Results
Serial Number Alpha (α) ISC [%] Beta (β) VOC [%] Gamma (γ) PMAX [%]
205M6M7210000018 0.049 -0.251 -0.339
— — — —
Report No.:704062000682 www.tuvsud.com
Rev.: 00
Date: 2020-06-19

Page 10 of 18
Technical Report

— — — —
Average — — —

3.3.1.2 PMAX vs. Irradiance & Temperature


Table 5:
Average PMAX Determined by Laboratory Results according to the IEC 61853-1 based on Table 2
Average Pmax [W] Results Acquired over Multiple Irradiances per Temperature
Irradiance Module Temperature
2
[W/m ] 15 °C 25 °C 50 °C 75 °C
100 40.682 38.865 - -
200 82.262 78.878 - -
400 167.342 160.793 147.298 -
600 252.091 242.928 221.923 201.552
800 334.935 323.793 295.210 268.044
1000 418.126 404.338 368.586 335.152
1100 - 443.912 405.159 367.909

Table 6:
PMAX Determined by Laboratory Results Scaled to Nameplate Power at STC
Doc No.: ITC-TTW0902.02E - Rev.7

Average Pmax [W] Results Acquired over Multiple Irradiances per Temperature
Irradiance Module Temperature
2
[W/m ] 15 °C 25 °C 50 °C 75 °C
100 40.749 38.929 - -
200 82.397 79.007 - -
400 167.616 161.056 147.539 -
600 252.504 243.326 222.286 201.882
800 335.483 324.323 295.693 268.483
1000 418.811 405.000 369.189 335.701
1100 - 444.639 405.822 368.511

Table 7:
Relative Efficiency by Laboratory Results Scaled to Nameplate vs. Irradiance at 25°C
Irradiance [W/m2]
Serial Number
100 200 400 600 800 1000 1100
Average 96.12% 97.54% 99.42% 100.13% 100.10% 100.00% 99.81%

Report No.:704062000682 www.tuvsud.com


Rev.: 00
Date: 2020-06-19

Page 11 of 18
Technical Report

4 PAN File Creation

4.1 PAN File Creation Method

The PAN file contains a number of model parameters organized in different tabs within PVsyst. The
parameters which affect the model results in forward bias (normal operation) are located in the tabs labeled
“Basic Data” and “Model Parameters”. TUV-SUD’s approach to PAN file creation is as following:
1. Enter manufacturer specifications on the “Basic Data” tab;
2. Enter the relative efficiency test results in Table 7under different irradiance at 25°C into “Additional Da-
ta/Low-light data” , and optimized the Rserie; It is mentioned that the relative efficiency is calculated after scale
the average measured PMAX lab data from Table 5 to the manufacturer’s nameplate power. The scaled
data is shown in Table 6 and Table 7.
3. Define the Rsh, Rsh0 and Rexp (on the “Model parameters” tab) for default values;
4. Enter the Pmax, Isc, Voc temperature coefficient in Table 4 into “Model parameters” tab;

4.2 Optimized PAN File Results


Doc No.: ITC-TTW0902.02E - Rev.7

Report No.:704062000682 www.tuvsud.com


Rev.: 00
Date: 2020-06-19

Page 12 of 18
Technical Report
Doc No.: ITC-TTW0902.02E - Rev.7

Report No.:704062000682 www.tuvsud.com


Rev.: 00
Date: 2020-06-19

Page 13 of 18
Technical Report

4.3 PAN File Result Verification

After creating the PAN file, a quality check is implemented in order to compare the PAN file model
consistence with measurements from the laboratory. The laboratory test results scaled are plotted as efficien-
cy vs. irradiance curves for each temperature of the IEC61853-1 test matrix, as shown in Table 8. Similarly,
efficiency vs. irradiance curves are generated using PVsyst and the newly created PAN file, as shown in Table
9. Comparison between the model and the measurements is represented with the following graph and table,
and the RMSE (Root Mean Square Error) of the optimized PAN file is reported, as shown in Table 10 and
Figure 4.
Table 8:
Efficiency Determined by Laboratory Results Scaled to Nameplate Power at STC
Average Pmax [W] Results Acquired over Multiple Irradiances per Temperature
Irradiance Module Temperature
[W/m2] 15 °C 25 °C 50 °C 75 °C
100 20.30% 19.40% - -
200 20.53% 19.68% - -
400 20.88% 20.06% 18.38% -
Doc No.: ITC-TTW0902.02E - Rev.7

600 20.97% 20.21% 18.46% 16.77%


800 20.90% 20.20% 18.42% 16.72%
1000 20.87% 20.18% 18.40% 16.73%
1100 - 20.14% 18.38% 16.69%

Table 9:
Efficiency Generated Using PVsyst and the Newly Created PAN file.
Average Pmax [W] Results Acquired over Multiple Irradiances per Temperature
Irradiance Module Temperature
[W/m2] 15 °C 25 °C 50 °C 75 °C
100 19.98% 19.23% 17.34% 15.40%
200 20.53% 19.81% 17.96% 16.07%
400 20.91% 20.22% 18.42% 16.57%
600 20.99% 20.31% 18.55% 16.73%
800 20.96% 20.29% 18.55% 16.74%
1000 20.87% 20.20% 18.48% 16.69%
1100 20.81% 20.14% 18.43% 16.65%

Table 10:
Comparison Result Between the Optimized PVsyst Model and the Measurements
RMSE NRMSE(Average)

Report No.:704062000682 www.tuvsud.com


Rev.: 00
Date: 2020-06-19

Page 14 of 18
Technical Report

0.0010433 0.005423

Figure 4:
Comparison of PVsyst Model, Using the Optimized PAN file, to the Laboratory Testing Results
Doc No.: ITC-TTW0902.02E - Rev.7

4.4 Measurement of incidence angle effects

Serial Number / —
Isc_80°/A: 0.854 —

Isc_-80°/A: 0.845 —

Isc_0°/A: 5.234 —

m=(Isc_80°/Isc_0°)/ cos 80° 0.940 —

n=(Isc_-80°/Isc_0°)/ cos 80° 0.930 —

DeviationΔ=|(m-n)/(m+n)|×100% ≤2% 0.53% P


Module IAM value
Angle Voc [V] Vmp [V] Isc [A] Imp [A] Pmp [W] FF [%] according to
IEC61853-2

Report No.:704062000682 www.tuvsud.com


Rev.: 00
Date: 2020-06-19

Page 15 of 18
Technical Report

0 — — 5.234 — — — 1.000
10 — — 5.178 — — — 1.005
20 — — 4.970 — — — 1.011
30 — — 4.611 — — — 1.017
40 — — 4.094 — — — 1.021
50 — — 3.420 — — — 1.017
60 — — 2.670 — — — 1.020
65 — — 2.250 — — — 1.017
70 — — 1.803 — — — 1.007
75 — — 1.333 — — — 0.984
80 — — 0.854 — — — 0.940
85 — — 0.355 — — — 0.778
Doc No.: ITC-TTW0902.02E - Rev.7

Fitted curve
(bo)

Report No.:704062000682 www.tuvsud.com


Rev.: 00
Date: 2020-06-19

Page 16 of 18
Technical Report

5 Documentation

Appendix 1: BOM details


Cell: JA Solar.
Type: JAC M9BR-9, Half cut, P type
dimensions: L x W: 158 .75x 79.375 (mm)
Cell thickness: 180±18 (µm)
Front cover: Flat glass group Co., Ltd.
Thickness:2.8mm
Type: Coating tempered glass
Rear cover: Crown Advanced Material Co., Ltd.
Type: Crown BE-xn (x=G, n=3), white
Thickness: 350±10% um
Encapsulation material: Hangzhou First Applied Material Co., Ltd.
Type F406P/F806S
Frame parts: Changzhou YONZ Technology Co., Ltd.
Type:6005-T6
Mounting parts: N/A
Adhesive for frame : Huitian
Type: HT906Z
Cell connector: TaiCang JuRen PV Material Co., Ltd.
Type:φ0.3 ± 0.02 mm
String connector: TaiCang JuRen PV Material Co., Ltd.
Doc No.: ITC-TTW0902.02E - Rev.7

Type: 0.35x6 mm
Soldering material: N/A
Fluxing agent: Shenzhen Vital New Material Co., Ltd.
Type: WTO-PV105A
Junction box: Shanghai JA Solar Technology Co., Ltd.
Type: PVJB-JA-004
Cable: Shanghai JA Solar Technology Co., Ltd.
Type: H1Z2Z2-K, 1x4.0mm2
Connector: QC Solar(Suzhou) Corporation.
Type: QC4.10-35,1500VDC, 41,IP68
Bypass diode: Yangzhou Yangjie Electronic Technology.
Type: SB2045DY
Potting material: Huitian
Type: 5299W-S
Adhesive for junction box : Huitian
Type: HT906Z
Additional material: Fixing Tape: UV-1, 3M
Insulation tape: BEC-201, Suzhou First PV Material Co., Ltd.

Report No.:704062000682 www.tuvsud.com


Rev.: 00
Date: 2020-06-19

Page 17 of 18
Technical Report

Appendix 2: List of measurement equipment


Description Type/ Equipment ID Calibration due date Remark
Pulsed Solar Simulator HYJC-YS-021 2020.11.19 -

Appendix 3: Statement of the estimated uncertainty of the test results


Pmax measurement uncertainty: 2.12% (K=2)
Voc measurement uncertainty: 0.98% (K=2)
Isc measurement uncertainty: 2.26% (K=2)

6 Summary

Below parameters are measured on three representative PV modules:


- The relative efficiency test results under different irradiance at 25°C
- Performance at the real irradiance and temperature conditions in table 2 of the IEC
61853-1
Based on the test results, PANFILE are optimized in Pvsyst. Efficiency vs. irradiance
curves are generated using PVsyst and the newly created PAN file, which is highly
matched with the test results in lab.
Doc No.: ITC-TTW0902.02E - Rev.7

According to the customer’s requirements, the PAN Files of JAM72S10-400/MR and


JAM72S10-410/MR were extended based on the measured parameter model of
JAM72S10-405/MR.

TÜV SÜD Certification and Testing (China) Co., Ltd, Shanghai branch,
TÜV SÜD Group

Engineer: __________________ Technical Report checked: __________________


Yang Xu Rongwei Jing
Project Handler Designated Reviewer

Report No.:704062000682 www.tuvsud.com


Rev.: 00
Date: 2020-06-19

Page 18 of 18