9HAHEAVY DUT Y GAS TURBINE
50HZ
448-571 MW SIMPLE CYCLE OUTPUT 50%
>64% COMBINED CYCLE EFFICIENCY
HYD RO G E N (H 2 ) C APAB LE WITH
A TECH N O LO GY PATHWAY
E NAB LI N G A FUTU RE
OUTSTANDING COMBINED CYCLE
EFFICIENCY >64% FOR REDUCED 100%
CUSTOMER CARBON FOOTPRINT.
9HA .01 9HA .02 Marrying sheer power with record-breaking
SC Net Output (MW) 448 571 efficiency, the 9HA gas turbine provides reliable
PERFORMANCE
SC PLANT
SC Net Heat Rate (Btu/kWh, LHV) 7,960 7,740 and dependable capacity for demanding
SC Net Heat Rate (kJ/kWh, LHV) 8,398 8,166 customer economics. It offers the most cost-
SC Net Efficiency (%, LHV) 42.9% 44.0%
effective conversion of fuel to electricity as well
CC Net Output (MW) 680 838
as industry-leading operational flexibility for
CC Net Heat Rate (Btu/kWh, LHV) 5,356 5,320
PERFORMANCE
increased dispatch and ancillary revenue. The
1X CC PLANT
CC Net Heat Rate (kJ/kWh, LHV) 5,651 5,613
CC Net Efficiency (%, LHV) 63.7% 64.1% 9HA gas turbine is at the heart of the world›s
Plant Turndown – Minimum Load (%) 33.0% 33.0% most efficient combined-cycle power plants
Ramp Rate (MW/min) 65 88 in commercial operation today and is a key
Startup Time (RR Hot†, Minutes) <30 <30
element in the path to decarbonisation.
CC Net Output (MW) 1,363 1,680
CC Net Heat Rate (Btu/kWh, LHV) 5,345 5,306
PERFORMANCE
2X CC PLANT
CC Net Heat Rate (kJ/kWh, LHV) 5,639 5,598
CC Net Efficiency (%, LHV) 63.8% 64.3%
Plant Turndown – Minimum Load (%) 15.0% 15.0%
Ramp Rate (MW/min) 130 176
Startup Time (RR Hot†, Minutes) <30 <30
NOTE: All ratings are net plant, based on ISO conditions and natural gas fuel. Actual performance will vary with project-specific
conditions and fuel. © 2021 GE. All rights reserved.
† Rapid Response/Hot Start
GEA32927B (09/2021)