Central inverter - PVS980-58
Central inverter
PVS980-58
The new high power FIMER central inverter raises the
performance, cost efficiency and ease of installation to new
levels. The inverters are aimed at system integrators and end
users who require high-performance solar inverters for large
photovoltaic (PV) power plants and are optimized for
multi-megawatt power plants.
Draft- Confidential (Subjected to changes)
Central inverter - PVS980-58
World’s leading inverter platform provide a rapid return on investment. New extended power
Like other FIMER central inverters, the PVS980-58 has been range along with fast site installation raises the total cost
developed on the basis of decades of experience in the industry efficiency to a new level.
and proven technology platform. Unrivalled expertise from the
world’s market and technology leader in frequency converters is Highlights
the hallmark of this solar inverter series. • High total performance
• Modular product design
The PVS980-58 inverter is one of the most efficient and • High DC input voltage up to 1500 VDC
cost-effective ways of converting the direct current (DC) • Extensive DC and AC side protection
generated by solar modules into high quality and CO₂-free • Easy to commission, no separate chiller installation
alternating current (AC) that can be fed into the power • Fast and easy AC coupling to transformer by busbars
distribution network. • Versatile design for large-scale PV plants to minimize
system costs
PVS980-58 central inverters from FIMER • Complete range of industrial data communication options,
FIMER PVS980-58 central inverters are ideal for large PV power including remote monitoring
plants. The high DC input voltage, high efficiency, proven • Life cycle service and support through FIMER’s extensive
components, compact and modular design and a host of life global service network
cycle services ensure FIMER PVS980-58 central inverters
Maximum energy revenues
FIMER central inverters have a high total efficiency. Precise, delivery times.
optimized system control and maximum power point tracking
(MPPT) combined with the unit’s highly efficient power converter Versatile design for large-scale PV plants
design deliver the maximum energy from the PV modules to the to minimize system costs
power distribution network. For end users, this generates the FIMER’s PVS980-58 central inverter enables system
highest possible revenues from the energy sales. integrators to design PV power plants that use the optimum
combination of inverters with different power ratings.
Patented cooling system Equipped with extensive electrical and mechanical
PVS980-58 inverter utilizes patented self-contained cooling protection, the inverters are engineered to provide a long and
system in power module cooling. This innovative, reliable service life of at least 25 years.
low-maintenance cooling solution is also used in other industrial
applications and is designed for demanding environments. Advanced grid support features
The cooling system needs no separate commission and it The PVS980-58 software includes all the latest grid support
ensures outstanding endurance. and monitoring features, including active power limitation,
fault ride through (FRT) with current feed-in and reactive
Compact and modular design power control.
PVS980-58 inverters are designed for fast and easy installation. Active and reactive power output can be controlled by an
The industrial design and modular platform provide a wide range external control system or automatically by the inverter.
of options, such as remote monitoring, fieldbus connection and
modular and flexible DC input connections. All grid support functions are parameterized, allowing easy
The integrated DC cabinet saves space and costs as the solar adjusting for local utility requirements. FIMER central
array junction boxes can be connected directly to the fused inverters are also able to support grid stability at night by
busbars in the DC cabinet. PVS980-58 inverters are customized providing reactive power with the DC input disconnected.
for the needs of end users and will be available with short
Draft- Confidential (Subjected to changes)
Central inverter - PVS980-58
Technical data and types
Product PVS980-58 PVS980-58 PVS980-58 PVS980-58
Type designation, PVS980-58 -4348-I -4565-J -478A-K -5000-L
Input (DC)
Maximum recommended input power (PPV,max) 1)
8696 kWp 9130 kWp 9564 kWp 10000 kWp
Maximum DC short circuit current 16 kA
Maximum operational DC current 5300 A
Maximum operational DC voltage (U max (DC) ) 2)
1500 V
DC voltage range for maximum power (U DC, mpp) @ -20 to +25 °C 850 to 1350 V 893 to 1350 V 935 to 1350 V 978 to 1350 V
DC voltage range for maximum power (U DC, mpp) @ 35 °C 850 to 1250 V 893 to 1250 V 935 to 1250 V 978 to 1250 V
DC voltage range for maximum power (U DC, mpp) @ 50 °C 850 to 1100 V 893 to 1100 V 935 to 1100 V 978 to 1100 V
Number of MPPT trackers 1
Number of protected DC inputs 3)
32 (+/-)
Output (AC)
Power @ 25 °C 4348 kVA 4565 kVA 4782 kVA 5000 kVA
AC current @ 25 °C 4184 A
Power @ 35 °C 4229 kVA 4441 kVA 4652 kVA 4864 kVA
AC current @ 35 °C 4070 A
Power (SN (AC)) @ 50 °C 3845 kVA 4037 kVA 4229 kVA 4421 kVA
AC current (IN (AC)) @ 50 °C 3700 A
Nominal output voltage (U N (AC)) 4)
600 V 630 V 660 V 690 V
Output frequency 5) 50/60 Hz
Harmonic distortion, current 6)
< 3%
Maximum AC short circuit current from network 66 kA (1 s RMS)
Distribution network type 7)
TN and IT
Efficiency
Maximum 8) 98.8%
Euro-eta 8) 98.6%
CEC efficiency 9)
98.5%
Power consumption
Own consumption in normal operation 5000 W
Maximum standby operation consumption 460 W
Auxiliary voltage type external 10)
1)
DC/AC ratio close to 2.0 might shorten maintenance intervals
2)
Throughout the temperature range
3)
Standard 24 DC inputs with negative grounding, fuses on positive pole only
4)
+/- 10%, consult FIMER for detailed information
5)
+/- 10 Hz
6)
At nominal power
7)
Inverter side must be IT type
8) Without auxiliary power consumption at min UDC
9)
Rounded according to CEC rules
10)
Internal available as an option
Draft- Confidential (Subjected to changes)
Central inverter - PVS980-58
Technical data and types
Product PVS980-58 PVS980-58 PVS980-58 PVS980-58
Type designation, PVS980-58 -4348-I -4565-J -478A-K -5000-L
Dimensions and weight
Width/Height/Depth, mm (W/H/D) 5600/2200/1600
Weight appr. Max. 6000 kg
Environmental limits
Degree of protection IP65 Electronics section & IP55 Rest of Inverter, Type 3R/ sand test certified
Ambient temp. range 11)
-20 … +50 °C
Maximum ambient temperature 12)
+60 °C
Relative humidity 4 ... 100%
Maximum altitude (above sea level) 13)
4000m 14)
Maximum noise level 84 dBA 15)
Protection
Ground fault monitoring Yes
Grid monitoring Yes
Anti-islanding Yes
DC reverse polarity Yes
AC and DC short circuit and over current Yes
AC and DC over voltage and temperature Yes
User interface and communications
Local user interface Local control panel
Analog inputs/outputs 2/1 as standard, extendable as engineered option
Digital inputs/relay outputs 7/1 as standard, extendable as engineered option
Fieldbus connectivity Modbus, Profinet, Ethernet IP 16)
Product compliance
Safety and EMC CE Declaration of Conformity, IEC62109-1, IEC62109-2,
Characteristics IEC60068-2-1, -2, -14, -30, IEC61683, EN50530, IEC61727, IEC62116, IEC62910
Grid codes CEA (India)
Grid support and grid functions Reactive power compensation, Power reduction, LVRT, HVRT, FqRT
11)
-40 °C as option 14)
Standard device up to 2000m, up to 4000m as an option
12)
Power limiting after 50 °C 15)
At partial power typically < 75 dBA
13)
Possible power limiting above 1000 m, depending on temperature 16)
More communication options as engineered option
PVS980-58 central inverter block diagram
PVS980-58,
EMC
EMC
Filter
filter
filter
Control
and
monitor
Draft- Confidential (Subjected to changes)
Central inverter - PVS980-58
Central inverter
PVS980-58 from 4348 to 5000 kVA
High total performance Versatile design for largescale PV plants
• High efficiency • Fast AC connection with busbars, no AC cable pulling
• Low auxiliary power consumption • Integrated DC connection with variable number of inputs
• Innovative controlled cooling • Wide standard option palette for tailoring
• Efficient maximum power point tracking
• Long and reliable service life of at least 25 years Minimizes system costs
• Very high output power and small footprint allows cost
Outstanding endurance for outdoor use efficient power block designs
• Water- and dustproof outdoor enclosure • 1500 VDC system voltage
• Designed to withstand the toughest environments • Wide ranged and highly efficient MPPT algorithm
• Long and reliable service life following the FIMER life cycle • Integrated protection to minimize external components
model • Fast and easy installation and commissioning
Modular industrial design Wide communication options
• Compact and easy-to-maintain product design • Complete range of industrial data communication options
• Fast and easy installation for SCADA connections
• Integrated and flexible DC input section • Ethernet/Internet Protocol
• Remote monitoring
Life cycle service and support
• FIMER’s extensive global service network Comprehensive simulation models
• Extended warranties • PSS/E
• Service contracts • PSCAD
• Technical support throughout the service life • DigSilent
Patented cooling system
• Self-contained, thermosiphon cooled power modules
• Liquid-cooled inverter power ratings with the simplicity of air
cooling
• No fillable liquids, pumps, valves, inhibitors or leaks
• Low maintenance
Draft- Confidential (Subjected to changes)
Data communication principle for PVS980-58 central inverter
PV String Communication network
strings central
box inverter
SCADA Mobile
Remote
Web
Local
Database
Mobile
Web
MV grid
Electricity Transformer SafeRing
switchgear
Options Related products
• Integrated and flexible DC input extension • Integrated products, pad mounted- or compact skid solutions
• AC breaker • String monitoring junction boxes
• Heavy duty (Type 1) surge protection • Remote monitoring solutions
• Various internal auxiliary power supply options up to 10kVA for
customer use Support and service
• Floating DC FIMER supports its customers with a global service network and
• Fieldbus and Ethernet connections provides a complete range of life cycle services from installation
• Current measurement to each DC input and commissioning to preventative maintenance, spare parts,
• High altitude version repairs and recycling.
• Low temperature version
• Warranty extensions
• Solar inverter care contracts
PVS980-58 from4348 to 5000 central inverter_EN REV. C 26-03.2021
For more information We reserve the right to make technical changes or We reserve all rights in this document and in the subject
please contact modify the contents of this document without prior matter and illustrations contained therein. Any
your local FIMER notice. With regard to purchase orders, the agreed reproduction, disclosure to third parties or utilization of
representative or visit: particulars shall prevail. FIMER does not accept any its contents – in whole or in parts – is forbidden without
responsibility whatsoever for potential errors or possible prior written consent of FIMER. Copyright© 2021 FIMER.
fimer.com lack of information in this document. All rights reserved.
Draft- Confidential (Subjected to changes)