0% found this document useful (0 votes)
44 views12 pages

Design of R.C.C. Retaining Wall and Reinforced Earth Wall For 6 Meter Height

Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-7 | Issue-3 , June 2023, URL: https://www.ijtsrd.com/papers/ijtsrd57526.pdf Paper URL: https://www.ijtsrd.com.com/medicine/ayurvedic/56201/tinospora-cordifolia-a-green-treasure/ragini-d-patil

Uploaded by

Editor IJTSRD
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views12 pages

Design of R.C.C. Retaining Wall and Reinforced Earth Wall For 6 Meter Height

Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-7 | Issue-3 , June 2023, URL: https://www.ijtsrd.com/papers/ijtsrd57526.pdf Paper URL: https://www.ijtsrd.com.com/medicine/ayurvedic/56201/tinospora-cordifolia-a-green-treasure/ragini-d-patil

Uploaded by

Editor IJTSRD
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

International Journal of Trend in Scientific Research and Development (IJTSRD)

Volume 7 Issue 3, May-June 2023 Available Online: www.ijtsrd.com e-ISSN: 2456 – 6470

Design of R.C.C. Retaining Wall and


Reinforced Earth Wall for 6 Meter Height
Roshan Patel1, Mr. Hariram Sahu2
1
PG Scholar, 2Assistant Professor,
1,2
Department of Civil Engineering, School of Engineering Eklavya University, Damoh, Madhya Pradesh, India

ABSTRACT How to cite this paper: Roshan Patel |


Retaining walls, which are fundamentally stiff constructions and Mr. Hariram Sahu "Design of R.C.C.
cannot allow considerable differential settlements unless they are Retaining Wall and Reinforced Earth
based on deep foundations, were almost entirely composed of Wall for 6 Meter
reinforced concrete for a long time. The price of reinforced concrete Height" Published
in International
retaining walls grew quickly as the height of the soil to be retained
Journal of Trend in
and the subsurface conditions deteriorated. Compared to reinforced Scientific Research
concrete walls, mechanically stabilised earth walls (MSEW) are more and Development
affordable soil-retaining constructions that can withstand (ijtsrd), ISSN: 2456- IJTSRD57526
considerably greater settlements. The strength of the soil may be 6470, Volume-7 |
greatly increased by adding tensile reinforcing components Issue-3, June 2023, pp.962-973, URL:
(inclusions), making the vertical face of the soil/reinforcement www.ijtsrd.com/papers/ijtsrd57526.pdf
system effectively self-supporting. Very steep slopes and vertical
walls can be built securely by using a facing system to stop soil Copyright © 2023 by author (s) and
raveling between the reinforcing sections. In some circumstances, the International Journal of Trend in
inclusions can endure bending due to shear forces, adding to the Scientific Research and Development
Journal. This is an
system's stability.
Open Access article
KEYWORDS: stiff constructions, Retaining walls, reinforced distributed under the
concrete, self-supporting, vertical face, shear forces terms of the Creative Commons
Attribution License (CC BY 4.0)
(http://creativecommons.org/licenses/by/4.0)

1. INTRODUCTION
Due to factors like construction economics and and any other sort of grade divider due to the increase
environmental safety, retaining walls or reinforced in traffic and congestion throughout metropolitan
earth walls are extremely important in the building of areas. Due to safety, environmental, and economic
contemporary infrastructure. Over time, several considerations, the building of these retaining walls or
different procedures have been taken into reinforced earth barriers is essential to the growth of
consideration. Techniques for planning, designing, contemporary infrastructure. This important
and building are continuously being improved to meet advancement was accompanied by a range of
a variety of requirements, including feasibility, retaining wall types, designs, and building techniques.
simplicity of construction, safety, maintainability, and The traditional gravity retaining walls evolved into
economics of the better soil retention system. An reinforced cement concrete retaining walls with
effective, better, and more affordable soil retention buttresses or counterforts as supports over time.
system is required for bridges, underpasses, flyovers,

@ IJTSRD | Unique Paper ID – IJTSRD57526 | Volume – 7 | Issue – 3 | May-June 2023 Page 962
International Journal of Trend in Scientific Research and Development @ www.ijtsrd.com eISSN: 2456-6470

Figure 1 Gravity Retaining Walls


1.1. Advantages of Reinforced Earth Wall
Reinforced Earth walls, also known as Mechanically Stabilized Earth (MSE) walls, offer several advantages
compared to traditional retaining wall systems. Here are some of the key advantages of Reinforced Earth walls:
1. Cost-effective: Reinforced Earth walls are often more cost-effective than other retaining wall systems. The
use of precast concrete panels or blocks for facing and granular backfill materials reduces construction time
and overall costs.
2. Easy and quick installation: The construction process for Reinforced Earth walls is relatively simple and
straightforward. The precast concrete facing units or blocks can be quickly installed, and the backfill
material can be easily placed and compacted. This leads to faster construction and reduced labor
requirements.
3. High strength and stability: The combination of reinforced soil and the facing elements results in a high-
strength and stable retaining wall structure. The reinforcements, typically in the form of geosynthetic
materials like geogrids or geotextiles, provide tensile strength to the soil mass, preventing its movement and
maintaining stability.
4. Flexibility and adaptability: Reinforced Earth walls can accommodate differential settlements and
variations in ground conditions more effectively than rigid retaining walls. The flexible nature of the system
allows it to adjust to ground movement, reducing the risk of wall failure.
5. Durability: Reinforced Earth walls are designed to withstand various environmental conditions, including
freeze-thaw cycles, seismic events, and corrosion. The use of high-quality materials and appropriate design
considerations can ensure the long-term durability and performance of the wall.
6. Aesthetically pleasing: Reinforced Earth walls offer design flexibility and can be customized to meet
aesthetic requirements. The facing elements can be finished with various textures, colors, or patterns,
allowing the wall to blend harmoniously with the surrounding environment.
7. Sustainable solution: The use of granular backfill materials and geosynthetic reinforcements in Reinforced
Earth walls promotes sustainable construction practices. These materials can be locally sourced and have a
lower environmental impact compared to other wall systems. Additionally, the durability and long lifespan
of Reinforced Earth walls contribute to their sustainability.
It's worth noting that while Reinforced Earth walls have many advantages, the suitability of this type of retaining
wall system depends on specific site conditions and project requirements. Professional engineering analysis and
design are necessary to ensure the optimal use of Reinforced Earth walls in any given project.
1.2. Disadvantages of Mechanically Stabilized Earth Wall
Mechanically Stabilized Earth (MSE) walls, also known as Reinforced Earth walls, have several advantages, but
they also come with certain disadvantages. Here are some of the potential drawbacks associated with MSE walls:
1. Complexity of design and construction: Designing and constructing MSE walls require specialized
engineering expertise. The process involves detailed analysis of soil conditions, loadings, and reinforcement
requirements. If not designed and constructed properly, MSE walls can fail, leading to costly repairs or even
collapse.

@ IJTSRD | Unique Paper ID – IJTSRD57526 | Volume – 7 | Issue – 3 | May-June 2023 Page 963
International Journal of Trend in Scientific Research and Development @ www.ijtsrd.com eISSN: 2456-6470
2. Cost of materials: MSE walls typically require the use of geosynthetic reinforcement materials, such as
geogrids or geotextiles, which can add to the overall cost. Additionally, the precast concrete facing panels or
blocks used for the wall facing can also contribute to the expense. While MSE walls can provide long-term
cost savings, the initial investment can be higher compared to other retaining wall options.
3. Drainage considerations: Proper drainage is critical for the performance and stability of MSE walls.
Inadequate drainage can lead to increased hydrostatic pressure behind the wall, potentially compromising its
integrity. Designing and implementing an effective drainage system can add complexity to the construction
process.
4. Limited applicability for certain soil conditions: MSE walls are typically suitable for granular or cohesive
soils. However, certain soil conditions, such as highly organic or expansive soils, may not be well-suited for
MSE wall construction. In such cases, alternative retaining wall systems may be more appropriate.
5. Height limitations: The height of MSE walls may be limited due to factors such as soil strength, facing
element capacity, and reinforcement requirements. Beyond a certain height, additional reinforcement or
alternative retaining wall systems may be necessary, increasing the complexity and cost of the project.
6. Visual aesthetics: While MSE walls can be designed with some customization options for facing elements,
they may not offer the same level of aesthetic flexibility as other types of retaining walls. The precast
concrete panels or blocks used for facing can have a utilitarian appearance, which may not be suitable for
projects with specific aesthetic requirements.
7. Environmental considerations: The production and use of geosynthetic materials in MSE walls have
environmental implications. The manufacturing process of geosynthetics requires energy and resources, and
their disposal at the end of their lifespan can present challenges. However, the use of locally sourced and
recycled materials can help mitigate these concerns.
It's important to note that the disadvantages mentioned above are general considerations, and the suitability of
MSE walls depends on specific project requirements and site conditions. Consulting with experienced engineers
and conducting thorough site assessments are crucial to determine the most appropriate retaining wall solution
for a given project.
1.3. Objective of Stabilized Earth Wall
The objective of a stabilized earth wall is to provide a stable and durable structure for retaining soil or creating a
barrier to control erosion. The primary goal is to prevent soil movement and maintain the stability of the retained
soil mass. Here are the key objectives of a stabilized earth wall:
1. Retaining soil: The main objective of a stabilized earth wall is to retain soil and prevent it from moving or
collapsing. By providing structural support, the wall helps to resist the lateral pressure exerted by the soil,
especially in sloping areas or where there is a significant height difference.
2. Preventing erosion: Stabilized earth walls are often used to control erosion and prevent the loss of soil due
to water runoff or other environmental factors. The wall acts as a barrier to protect the underlying soil from
erosion caused by wind, water, or other erosive forces.
3. Creating usable space: In some cases, stabilized earth walls are used to create usable space by leveling or
terracing sloping areas. The wall allows for the creation of flat surfaces that can be utilized for various
purposes such as building construction, agriculture, landscaping, or recreational areas.
4. Ensuring safety: One of the key objectives of a stabilized earth wall is to ensure the safety of structures,
infrastructure, and people in areas prone to soil movement or landslides. The wall provides stability and
reduces the risk of slope failures, which can be hazardous and cause property damage or injuries.
5. Minimizing environmental impact: Stabilized earth walls aim to minimize the environmental impact
associated with soil erosion and slope instability. By preventing soil movement and erosion, these walls help
preserve the natural landscape, protect ecosystems, and prevent sedimentation in nearby water bodies.
6. Long-term durability: Another objective of stabilized earth walls is to provide a long-lasting and durable
solution. The use of suitable stabilization techniques, materials, and proper design ensures the structural
integrity of the wall over time, reducing the need for frequent maintenance or replacement.
7. Design of Reinforced Earth wall and R.C.C Retaining Wall for different heights.
8. Calculating the Quantity of various components of the retaining wall and reinforced earth wall
9. Calculating the cost of Retaining wall and Reinforced Earth Wall at different heights.
10. Calculation of quantities and cost for various types of reinforced earth wall with different type of reinforcing
material.

@ IJTSRD | Unique Paper ID – IJTSRD57526 | Volume – 7 | Issue – 3 | May-June 2023 Page 964
International Journal of Trend in Scientific Research and Development @ www.ijtsrd.com eISSN: 2456-6470
It's important to note that the specific objectives of a stabilized earth wall may vary depending on the project
requirements, site conditions, and the desired outcomes. Professional engineering and design expertise are
essential to ensure that the objectives are met effectively and efficiently.
2. LITERATURE REVIEW
Basudhar et al. (2007) had sought to identify the geosynthetic reinforced earth retaining walls with the lowest
cost design that could withstand both static and dynamic loads. Their research has shown that the expense
associated with MCU facing units makes MSE walls built with geo-grids more expensive than those built with
geo textiles. For walls less than six metres in height (between three and six metres), it is typically noted that the
geogrid wall shows higher cost in the range of 20 to 30 percent, while for walls longer than six metres in height,
the rise is in the range of 10 to 20 percent.
Rajpaksha (2008) Reinforced earth barriers are becoming more and more common. By retaining the lateral
ground pressure by metal strips, reinforced earth walls are built. The soil pressure in the reinforced earth walls is
resisted by metal strips. The author investigated several equations that may be constructed to calculate the lateral
earth force acting on a facing unit. Additionally, he has investigated and examined the equations used to
calculate the metal-soil friction as well as the horizontal force on the facing unit. By providing a design example
to determine the length of the metal strips and solving the problem at hand, it is possible to determine the
relationship between the metal-soil friction and the vertical effective stress acting on the strip, the area of the
metal strip, and the friction angle between metal and soil.
Shekarian et al. (2008) Selecting earth pressure is required in order to design retaining walls using traditional
methods. Different theories on the distribution of earth pressure for retaining walls are put forth, however in
reinforced soil, this distribution differs from that in unreinforced soil. The extent and distribution of lateral wall
displacement are crucial elements in pressure distribution. In these types of walls, the vertical spacing between
anchors, the slope of the anchors, the wall stiffness, and the shear resistance of the soil may all affect the
displacement of the wall and the distribution of earth pressure. The degree of pressure reduction brought on by
mass reinforcement has been examined in this study. Even though this publication identifies the various
techniques for estimating earth pressure, several finite element analyses performed, and their outcomes assessed.
In compared to a wall without reinforcement, numerical analysis of a rigid reinforced wall with an anchor
revealed that the pressure on the wall is reduced as a result of parameters like stiffness, length, number, and
distance of anchors. Additionally, the findings of the research demonstrated that soil reinforcement alters the
wall displacement curve and lowers the average wall displacement.
Tatsuoka (2008) In Japan, permanent geosynthetic-reinforced soil (GRS) retaining walls (RWs) with a full
height rigid face have been built for highways as well as railways, including high-speed train lines, from roughly
20 years ago. More than 100 kilometres of traditional cantilever RWs and steel-reinforced soil RWs have been
replaced with this kind of GRS RW. Many RWs of this sort were also built to replace classic type RWs and
embankments that fell after previous earthquakes and high rains, even though most of them are new walls. Many
bridge abutments with geosynthetic-reinforced backfill have been built by utilising this technique. The most
recent design, known as the GRS Integral Bridge, consists of a continuous girder connected to two RC facings
with layers of geosynthetic reinforcement in the backfill.
Yang et al. (2009) a cast-in-situ concrete-rigid facing geogrid reinforced soil retaining wall of the Gan (Zhou)-
Long (Yan) railway main line of China that was being built under my supervision. The reinforced soil wall
confronting the reinforcement, the lateral earth pressure, the vertical foundation pressure, and the horizontal
facing deformation were all evaluated. The vertical foundation pressure of a reinforced soil retaining wall is not
linear along the length of the reinforcement; it is highest in the centre and progressively decreases at the top and
bottom. The experiments showed that the active lateral earth pressure is greater than the lateral earth pressure
that exists within the reinforced soil wall, which is non-linear along height.
Ahmadabadi and Ghanbari (2009) had researched the novel method using the horizontal slice method to
calculate the active earth pressure on retaining walls with reinforced and unreinforced cohesive-frictional
backfill. The suggested approach demonstrates the non-linear distribution of active earth pressure fluctuation
with wall depth in cohesive-frictional soils. For cohesive-frictional soils, the angle of failure wedge rises linearly
as the cohesive strength of the soil increases. There is very little difference between the analytical results from
the suggested approach and those from earlier studies and the AASHTO method. In order to determine the active
earth pressure, tensile force of reinforcement, and angle of failure wedge for unreinforced and reinforced walls in
cohesive-frictional soil, the analytical technique described can be employed.

@ IJTSRD | Unique Paper ID – IJTSRD57526 | Volume – 7 | Issue – 3 | May-June 2023 Page 965
International Journal of Trend in Scientific Research and Development @ www.ijtsrd.com eISSN: 2456-6470
Ling et al. (2009) had centred on the outcomes of finite element modelling of a full-scale geosynthetic soil
retaining wall made of concrete blocks that was built at the Public Works Research Institute in Japan. It was
decided to include a nonlinear hyperbolic geosynthetic model into a computer programme that could simulate
the behaviour of the interaction between the soil and the structure. While the block-block and soil-block
interactions were modelled using interface components, the soil was approximated using a hyperbolic model.
The finite element model is capable of modelling the building behaviour of concrete-block geosynthetic-
reinforced soil structures, according to a comparison of numerical and measured experimental data.
Bathurst et al.( 2009) The goal of the research is to establish a novel working stress technique for calculating
the reinforcement loads in geosynthetic reinforced soil walls. It does this by synthesising the authors' previous
work. Prior to achieving this goal, careful back-analyses of a database of instrumented and monitored full-scale
field and laboratory walls are used to show that the Simplified Method currently being used in North America
produces estimates of the volume of reinforcement needed to produce satisfactory long-term wall performance
that are overly conservative. By carefully interpreting reinforcement strains and converting strain to load using
an appropriately chosen reinforcement stiffness value, the novel approach is calibrated against observed in-situ
wall reinforcement loads.
Diwalkar (2020) In general, retaining walls are strong, inflexible structures designed to sustain soil masses
laterally. This review study's goal is to comprehend the examination of retaining walls. The major consideration
in the study and design of retaining walls is lateral earth pressure. Regarding the retaining wall's stability against
tipping over and sliding, as well.
Kong et al. (2020) Structures called reinforced retaining walls are built horizontally to withstand soil pressure
by using the frictional force that the backfill imparts. Because they offer high safety and economic efficiency,
reinforcements are used. But insufficient reinforcement might cause collapse, while too much reinforcement
hurts the economy. So it's crucial to choose the right kind, size, and spacing of reinforcements. However, at
actual sites, the same number of reinforcements are frequently put despite the fact that the stress and fracture
processes in the straight and curved sections of reinforced soil retaining walls differ. Such a strategy may cause
the wall to crumble or make it less economically viable.
Nouman et al. (2023) For practising geotechnical/civil engineers, predicting settlement of GRS abutments under
service loading circumstances is a difficult and complex issue. In order to anticipate the settling of the GRS
abutments, a unique hybrid artificial intelligence (AI)-based model known as ANN-HHO, which combines
artificial neural networks (ANN) and Harris hawks' optimisation (HHO), was created in this research. Support
vector regression (SVR), Gaussian process regression (GPR), relevance vector machine (RVM), sequential
minimal optimisation regression (SMOR), and least-median square regression (LMSR) are five other strong
intelligent models that were built and contrasted with the ANN-HHO model. Predictive power, reliability, and
Robust statistical testing, ranking criteria, a multi-criteria approach, uncertainity analysis, and sensitivity
analysis (SA) were used to evaluate the model's robustness. Additionally, many sizable independent
experimental investigations on GRS abutments published in the scientific literature were used to support the
model's prediction accuracy. The obtained results showed that the ANN-HHO model produced improved
performance in comparison to competing models and reasonably accurately forecasted the settling of GRS
abutments. In order to investigate the in-service performance of GRS abutments, geotechnical and civil
engineers use it as one of their prediction tools for making preliminary decisions. Finally, the model has been
reduced to a straightforward mathematical formulation allowing straightforward hand computations, and it has
been demonstrated to be more time and cost-effective than experimental testing and numerical simulations.
Yang et al. (2023) the effectiveness of geosynthetic-reinforced soil (GRS) walls with marginal backfill exposed
to rainwater infiltration was investigated using a series of model experiments. In order to avoid the GRS wall
failing owing to high rainfall, the efficiency of improvement measures—such as reducing reinforcement spacing
and increasing sand cushion thickness—was assessed. Throughout the test, it was kept an eye on how the
distribution and change of the volumetric water content, porewater pressure, wall deflection, and reinforcement
tensile strain. Using the bright dyeing approach, it was possible to see how the wetting front was moving and
how the sand cushions were serving their purpose of draining. In the baseline scenario, when rain fell, the wall
started to sag, which caused the possible failure surface to slowly recede. As soon as the possible failure surface
shifted past the strengthened zone, the upper reinforcement layers began to come away, which caused the GRS
wall to collapse in a compound failure scenario. Reduced reinforcing spacing and thicker sand cushions
significantly decreased wall deflection and improved wall stability. Sand cushions used in between

@ IJTSRD | Unique Paper ID – IJTSRD57526 | Volume – 7 | Issue – 3 | May-June 2023 Page 966
International Journal of Trend in Scientific Research and Development @ www.ijtsrd.com eISSN: 2456-6470
reinforcement layers can help slow down water penetration and lessen the buildup of porewater pressure inside
the wall. Based on the findings, recommendations for building GRS walls that can withstand rain are also made.
3. DESIGN MEHODOLOGY OF R.C.C. RETAINING WALL AND REINFORCED EARTH
The design methodology for a reinforced concrete (R.C.C.) retaining wall and a reinforced earth wall for a height
of 6 meters will involve different approaches. Here is a general overview of the design methodology for each
type of wall:
3.1. Design Methodology for R.C.C. Retaining Wall
1. Determine design parameters: Gather information about the site conditions, including soil properties,
groundwater levels, and surcharge loads. These parameters are crucial for designing the wall.
2. Calculate active and passive earth pressures: Determine the magnitude and distribution of earth pressures
acting on the retaining wall. Use methods such as Rankine's theory or Coulomb's theory to calculate active
and passive earth pressures based on the soil properties.
3. Design the wall structure: Select appropriate wall dimensions, including height, base width, and stem
thickness. Design the reinforcement layout based on the calculated bending moments and shear forces along
the wall. Use structural engineering principles and codes to ensure the wall can withstand the applied loads
and remain stable.
4. Check stability: Perform stability analysis to ensure the wall can resist overturning, sliding, and bearing
capacity failures. Consider factors such as foundation design, global stability, and the effects of water
pressure if applicable.
5. Provide drainage: Incorporate proper drainage systems to control water accumulation behind the wall. This
helps to alleviate hydrostatic pressure and minimize the risk of wall failure.
6. Construction considerations: Develop construction drawings, detailing reinforcement layout, specifications
for concrete mix, and wall facing if applicable. Coordinate with contractors and construction professionals to
ensure the design is implemented correctly.
3.2. Design Methodology for Reinforced Earth Wall
1. Gather site information: Collect relevant information about soil properties, groundwater levels, surcharge
loads, and any other site-specific factors influencing the design.
2. Determine the facing system: Select the appropriate facing system for the reinforced earth wall. This may
involve precast concrete panels, concrete blocks, or other facing options based on aesthetic and functional
requirements.
3. Calculate the required reinforcement: Perform geotechnical analysis to determine the reinforcement
requirements. This involves evaluating the stability of the reinforced soil mass, calculating tensile forces, and
selecting appropriate reinforcement materials such as geosynthetics.
4. Design the backfill: Choose suitable granular backfill materials and determine their compaction
requirements. Consider factors such as friction angle, compaction characteristics, and long-term stability.
5. Stability analysis: Conduct stability analysis to ensure the reinforced earth wall can resist the applied loads,
including earth pressures and any additional surcharges. Check for factors such as wall overturning, sliding,
and bearing capacity.
6. Construction considerations: Prepare construction drawings and specifications, including reinforcement
layout, facing system details, and backfill specifications. Coordinate with contractors to ensure proper
construction techniques, compaction, and installation of reinforcements.
3.3. Design Procedure of Retaining WallTop of Form
Designing a reinforced earth retaining wall involves several steps and considerations. While it is challenging to
provide a comprehensive generalized flow chart without specific project details, I can outline a basic procedure
that covers the key steps involved. Please note that this flow chart is a general guideline and may need to be
adjusted based on the specific requirements of your project. Here's a generalized flow chart for designing a
reinforced earth retaining wall using reinforcement steel:
Determine the site conditions, including soil properties, water table, and slope stability analysis.
Obtain information on the required wall height, width, and backfill properties.
Identify any additional loads or design considerations specific to your project.
Perform preliminary design:
Determine the design methodology and code requirements to be followed.

@ IJTSRD | Unique Paper ID – IJTSRD57526 | Volume – 7 | Issue – 3 | May-June 2023 Page 967
International Journal of Trend in Scientific Research and Development @ www.ijtsrd.com eISSN: 2456-6470
Conduct an initial stability analysis to assess the overall stability of the wall.
Select the appropriate wall type based on site conditions and project requirements (e.g., gravity wall,
reinforced soil wall, etc.).
Calculate the required strength and stability of the retaining wall.
Analyse the internal and external forces acting on the wall.
Select an appropriate reinforcement type (e.g., steel strips, geogrids) based on design requirements and
project constraints.
Determine the facing system, including the type of facing material (e.g., concrete panels, segmental blocks).
Calculate the facing stability, considering the applied loads, connection details, and structural requirements.
Specify the facing reinforcement (if required) to provide stability and distribute the forces.
Analyse and design the reinforcement elements:

Figure: 1 Flowchart of R.C.C. Retaining Wall

@ IJTSRD | Unique Paper ID – IJTSRD57526 | Volume – 7 | Issue – 3 | May-June 2023 Page 968
International Journal of Trend in Scientific Research and Development @ www.ijtsrd.com eISSN: 2456-6470

Selection of Structural Types

Selection of Foundation Type

Determination of Design Condition

Examination of Earquake Effect

Assumption of Sectional Shape of Wall

Calculation and Conbination of Loads

Stability Analysis for Wall and


Foundation Ground

Figure: 2 Flowchart of Retaining Wall Design


4. R.C.C. RETAINING WALL FOR HEIGHT OF 6.0 M
Height of embankment above GL =6.0 m
The values for Grade of concrete, S.B.C. of soil, Density of soil, Grade of steel, Density of Concrete, Friction
Coefficient, Active earth Pressure, Angle of wall friction, Angle of internal, Coefficient of active earth Pressure
(Ka) is kept same as that for RCC retaining wall for the height of 4.0m.
Dimensions of Retaining Wall
Provide minimum Depth of Foundation = 1.0 m
Height of wall above ground level = 6.0 m
Overall depth of Foundation (H) = 7.0 m
Base Width (b) = 3.5 m
Toe Projection = 1.05 m
Thickness if Base Slab = 0.585 m
Top width of Stem = 0.2 m
Thickness of Stem = 0.583 m
Heel Projection = 1.867 m
Clear stem of height (h) = 6.4 m
Horizontal Pressure = 163.33 KNm
Bending Moment = 190.55 KNm
Total Weight = 793.52 Kn.m
Stability against Overturning
FOS = 3.74 > 1.4
Hence Safe
Stability against sliding
FOS = 0.974 <1.4
Hence Shear Key is required
Check for maximum pressure at toe
Safe
Maximum pressure at toe
Pmax = 108.58 KN/m2 < SBC

@ IJTSRD | Unique Paper ID – IJTSRD57526 | Volume – 7 | Issue – 3 | May-June 2023 Page 969
International Journal of Trend in Scientific Research and Development @ www.ijtsrd.com eISSN: 2456-6470
Hence Safe
Pmin = 93.37 KN/m2 < SBC
Hence Safe
Design of Stem
Provide overall Depth = 500 mm
Clear Cover = 50 mm
Provide depth = 450 mm
Area of steel r/f = 2477.88 mm2
Assume spacing as 130 mm c/c
Distribution of Steel R/F
Average thickness of wall = 391.67 mm
Area of steel = 470 mm
Steel to be provided in each face = 235 mm
Spacing to be provided = 330 mm c/c
Check for Shear
Hence No Shear Reinforcement is required
Design of Shear Key
Provide a 200 mm deep shear Key
5. Design for reinforced RE Wall with metallic strips for Height of 6.0 m
Height of embankment above GL = 6.0 m
The values for Grade of concrete, S.B.C. of soil, Density of soil, Grade of steel, Density of Concrete, Friction
Coefficient, Active earth Pressure, Angle of wall friction, Angle of internal, Coefficient of active earth Pressure
(Ka) is kept same as that for Reinforced RE wall for the height of 4.0 m.
Dimensions of Wall
Provide minimum Depth of Foundation = 1.0 m
Height of wall above ground level = 6.0 m
Overall depth of Foundation (H) = 7.0 m
Base Width = 4.2 m
Lateral earth Pressure = 33.33 KNm
Horizontal Pressure = 147.00 KN/m
Assume horizontal and vertical spacing of strips 1.0m
Width of strips = 0.1 m
Density of material to be used in filling = 18 Kn/m2
Yield strength in steel = 2, 50, 000 Kn/m2
Height of strips to be considered for RE wall
Considering clear cover from foundation = 0.5 m
Considering clear cover from top = 0.5 m
Height in which reinforcement is to be provided = 6.0 m
No of reinforcements = 6.0 m
Force at reinforcement = 51 Kn
Provide thickness as 15.0 m
Stability against sliding
Safe
Stability against Overturning
Safe
Bearing Pressure
Safe

@ IJTSRD | Unique Paper ID – IJTSRD57526 | Volume – 7 | Issue – 3 | May-June 2023 Page 970
International Journal of Trend in Scientific Research and Development @ www.ijtsrd.com eISSN: 2456-6470
6. COST OF RETAINING WALL AT 6m HEIGHTS
Table 1 Retaining Wall for 6 m Height
Item No as
per SOR Description Unit Rate Quantity Amount
2014
Earth work in Excavation
Excavation in ordinary rock by Manual Means
3.2 Excavation in ordinary rock including loading in Cum 226.00 40.00 9,040
a truck and carrying of excavated material to
embankment site with all lifts and leads
PCC M-15 in Foundation
Plain cement concrete M-15 mix with crushed
stone aggregate 40 mm nominal size
9.1 Cum 4,209.00 5.25 22,097
mechanically mixed, placed in foundation and
compacted by vibration including curing for 14
days.
Plain/Reinforced cement concrete in sub-
13.6 structure complete as per drawing and technical Cum 6,588.00 52.48 345,751
specifications.
TMT / HYSD Reinforcement: in Retaining walls
13.7 MT 75,415.00 4.62 348,298
as per Technical Specification Clause 1600.
Total Amount 725,187
Table 2 RE FACIA WALL for 6m Height
Height/
Sl. No. Description of works Unit Length Width Qty Total Quantity
Depth
A Earth work in Excavation
cum 10.000 4.700 1.000 47.000
TOTAL Earth work 47.000 47.000
B GSB Below Leveling PAD
GSB Below Leveling PAD cum 10.000 4.700 0.150 7.050
TOTAL GSB 7.050 7.050
C PCC M-15 Grade Concrete
M-15 G. Con. Leveling Pad cum 10.000 0.450 0.150 0.675
TOTAL M-15 0.675 0.675
C RE wall Fill And Geo Grid
i RE wall Fill cum 10.000 4.200 7.000 294.000
ii RE wall facia panel Sqm 10.000 1.000 7.000 70.000
iii Geo Grid cum 10.000 4.200 7.000 294.000
658 658

7. CONCLUSIONS amount of ground that has to be cut and filled, the


1. To study the cost effectiveness of the Retaining wall or slope's height and type, the soil type
wall and reinforced earth walls the Retaining wall present, the backfill material available, the
has been designed for a height of 6 m. appearance of the facing panel, and whether it
will be used temporarily or permanently.
2. As it is a well-known fact that the retaining wall
tend to fail after a certain height. To stabilize the 4. It has been shown that for higher heights,
Retaining walls, counter forts are added to the reinforced concrete retaining walls are often more
retaining wall and the same has been designed for costly than R walls with precast concrete facings.
the height of 6m Similarly the Reinforced Earth
5. The methods used to design various types of
walls also known as RE walls have been designed
outwardly and internally stabilised walls have
for the heights of 6m
been described in depth, with examples taken
3. A soil-reinforced structure's site-specific costs from the RCC retaining wall/Counter fort.
depend on a variety of variables, including the Respectively, retaining walls and RE walls have

@ IJTSRD | Unique Paper ID – IJTSRD57526 | Volume – 7 | Issue – 3 | May-June 2023 Page 971
International Journal of Trend in Scientific Research and Development @ www.ijtsrd.com eISSN: 2456-6470
been evaluated and developed for a range of Considerations for Geogrid-Segmental Block
heights. Mechanically Stabilized Earth Retaining Walls,
Transportation Research Record, 1414:12−15,
6. The amount of the walls is then determined, and a
1993
cost estimate for their 6 metre length has been
made. For the specific geometry and stress [7] Aylin Ece Kayabekir, Zülal Akbay Arama,
parameters taken into account in this study, it has Gebrail Bekdaş, Sinan Melih NigdeliZong Woo
been discovered that internally stabilised walls Geem (2020).” Eco-Friendly Design of
(RE walls) are much more cost-effective than Reinforced Concrete Retaining Walls: Multi-
externally stabilised walls, or retaining walls. objective Optimization with Harmony Search
7. The major contribution in the cost difference is Applications”, Sustainability 2020, 12(15),
attributed to the huge amount of concrete and 6087; https://doi.org/10.3390/su12156087
Received: 15 June 2020 / Revised: 11 July
steel bars usually required in the retaining walls
as compared to RE walls due to the basic design 2020 / Accepted: 27 July 2020 / Published: 29
July 2020
difference.
[8] Azad, A., Yasrobi, S., Pak, A., (2008) Seismic
8. The retaining wall is designed ion the basis that
active earth pressure distribution behind rigid
the earth is retained behind the wall and major
retaining walls. Soil Dynamics and Earthquake
loading is ion the wall due to earth back fill.
Engineering 28 (5), 365–375, 2008
Whereas, in its counterpart i.e. the Reinforced
Earth Wall the friction between the earth and the [9] B. Ceranic, C.Fryer and R.W. Banies. (2001) an
reinforcement shares the load which is then application of simulated annealing to the
transferred to the ground. optimum design of reinforced concrete
retaining structures. Computers and Structures,
9. The reinforcement thus develops tension and the
79: 1569-1581, 2001
earth behaves as if it has cohesion
[10] Baker, R., Klein, Y., (2004) An integrated
REFERENCES
limiting equilibrium approach for design of
[1] AASHTO, (1997) Standard Specifications for
reinforced soil retaining structures, part I:
Highway Bridges, Div. 1, Sect. 5, Retaining
formulation. Geotextiles and Geomembranes22
Walls, Washington, DC, 89pp, 1997.
(3), 119–150, 2004
[2] Al, H.O., Muhunthan, B., (2006) Numerical
[11] Bathurst, R.J., Jarrett, P.M., Benjamin,
procedures for deformation calculations in the
D.J.R.S., (1993) A database of results from an
reinforced soil walls. Geotextiles and Geo-
incrementally constructed geogrid-reinforced
membranes 24 (1), 52–57, 2006
soil wall test. In: Proceedings of Soil
[3] Alborz, Siavash. (2016). STUDY ON Reinforcement: Full Scale Experiments of the
HORIZONTAL DISPLACEMENT OF 80’s. ISSMFE/ENPC, Paris, France, pp. 401–
RESTRAINED EXCAVATION WALLS BY 430, 1993b
CANTILEVER RETAINING WALL.
10.5281/zenodo.56029. January 2016 [12] Bathurst, R.J., Simac, M.R., (1994)
Geosynthetic reinforced segmental retaining
DOI:10.5281/zenodo.56029
wall structures in North America. In:
[4] Al-Hattamleh, O., Muhunthan, B., (2006) Proceedings of the Fifth International
Numerical procedures for deformation Geosynthetics Conference, Singapore, SEAC-
calculations in reinforced soil walls. IGA, Keynote Lecture Volume, pp. 29–54,
Geotextiles and Geomembranes 24 (1), 52–57, 1994.
2006
[13] Bathurst, R.J., Simac, M.R., Christopher, B.R.,
[5] Allen, T.M., Christopher, B.R., Holtz, R.D., Bonczkiewicz, C., (1993) A data-base of results
(1992) Performance of a 12.6 m high geotextile from a geosynthetic reinforced modular block
wall in Seattle, Washington, geosynthetic- soil retaining wall. In: Proceedings of Soil
reinforced soil retaining walls. In: Wu, J.T.H. Reinforcement: Full Scale Experiments of the
(Ed.), Balkema, Proceedings of the 80’s. ISSMFE/ ENPC, Paris, France, pp. 341–
International Symposium on Geosynthetic- 365, 1993a
Reinforced Soil Retaining Walls, Denver,
Colorado, USA, pp. 81–100, 1992 [14] Berg, R.R., Meyers, M.S., (1997) Analysis of
the collapse of a 6.7m high geosynthetic-
[6] Anderson, R.B. (1993) Construction reinforced wall structure. In: Proceedings of the

@ IJTSRD | Unique Paper ID – IJTSRD57526 | Volume – 7 | Issue – 3 | May-June 2023 Page 972
International Journal of Trend in Scientific Research and Development @ www.ijtsrd.com eISSN: 2456-6470
Geosynthetics ’97. IFAI, Roseville, MN, pp. soil abutments using hybrid
85104, 1997. intelligentmodeling,=JournalofRockMechanics
[15] Berg, R.R., Nelson, B., (2000) Practical andGeotechnicalEngineering,https://doi.org/10.
1016/j.jrmge.2022.04.012.(https://www.science
implications of MBW unit-geosynthetic
connection strength requirements. In: direct.com/science/article/pii/S1674775522001
093)
Proceedings of the 14th GRI Conference. GAI
Publications.Folsom, PA, pp. 307–322, 2000 [18] Kuo-Hsin Yang, Hsin-Ming Wu, Ting-Ling
Tseng, Chungsik Yoo,Model tests of
[16] Muhammad Nouman Amjad Raja, Syed Taseer
geosynthetic-reinforced soil walls with
Abbas Jaffar, Abidhan Bardhan, Sanjay Kumar
marginalbackfillsubjectedtorainfall,Geotextiles
Shukla,
andGeomembranes,https://doi.org/10.1016/j.ge
[17] Predicting and validating the load-settlement otexmem.2022.12.002.(https://www.sciencedire
behavior of large-scale geosynthetic-reinforced ct.com/science/article/pii/S0266114422001340)

@ IJTSRD | Unique Paper ID – IJTSRD57526 | Volume – 7 | Issue – 3 | May-June 2023 Page 973

You might also like