D GENERAL NOTES LIGHTING LEGEND
E2E2 SCALE NTS MTS
WEATHERPROOF CONVENIENCE OUTLET
WEATHERPROOF CONVENIENCE OUTLET
1. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PROVISIONS OF THE LATEST
EDITION OF THE PHILIPPINE ELECTRICAL CODE, CITY ORDINANCES, RULES AND REGULATIONS OF MERALCO, J 8" PVC PULL BOX / JUNCTION BOX
NATIONAL BUILDING CODE AND THE FIRE CODE OF THE PHILIPPINES. G 8" PVC GENERATOR PULL BOX ENTRY
DT MANUAL DOUBLE THROW SWITCH
2. THERE SHALL BE ONLY ONE SERVICE DROP TO THE BUILDING. POWER SUPPLY SHALL BE 230VOLTS, SINGLE PANEL BOX
PHASE,2WIRES PLUS GROUND 60 HERTZ. SMB SUB METER BANK
CEILING MOUNTED LIGHT
3. MATERIALS & EQUIPMENT TO BE USED SHALL BE NEW & OF THE APPROVED TYPE FOR BOTH LOCATION & SD SMOKE DETECTOR
PURPOSE PROPER FITTINGS AND SUPPORT. LED PINLIGHT 7 WATTS
E EMERGENCY LIGHT
ORBITAL FAN
4. SERVICE ENTRANCE SHALL BE IN RIGID STEEL CONDUIT. ALL INSTALLATIONS EMBEDDED IN CONCRETE WALLS,
WALL MOUNTED LAMP
CEILING, FLOORING & SLABS SHALL BE IN POLYVINYL CHLORIDE PIPE (PVCP).
CEILING EXHAUST FAN
FLUSH DOWNLIGHT
5. ADEQUATE AND EFFECTIVE EQUIPMENT GROUNDING SYSTEM SHALL BE PROVIDED.
MOUNTED LIGHT BELOW STAIRS LANDING
6. MOUNTING HEIGHTS OF DEVICES SHALL BE: F4 FEEDER NUMBER
6
A. PANEL BOARDS: 1.60M. ABOVE FINISHED FLOOR LEVEL M MAIN KILOWATTHOUR METER
B. SWITCHES: 1.37M. ABOVE FINISHED FLOOR LEVEL S
C. CONVENIENCE OUTLETS: 0.30M. ABOVE FINISHED FLOOR LEVEL. M KILOWATT HOUR SUBMETER
LIGHTING RACEWAY ( CEILING )
7. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DULY LICENSED LIGHTING TO SWITCH LINE
ELECTRICAL ENGINEER OR MASTER ELECTRICIAN. POWER RACEWAY IN WALL OR FLOOR
FUTURE PROVISION
8. GFCI SHALL BE INSTALLED IN REQUIRED LOCATION. Sa 1WAY SWITCH
FSa ORBITAL FAN SWITCH
3Sa 3WAY SWITCH
1.37 LIGHT RECEPTACLE
3
AC AC
AC 7W MR6 PINLIGHT
4
CLOSET
CLOSET
S1
CHANDELIER
S1 MOUNTED LED
S1
LARGE MOUNTED LIGHT
S2
S1 S1 HIGH WINDOW
S1
60
S1 WALL / BRACKET LAMP
S1
60
RAILINGS
UP S1 3
S1
60
DN
UP
S1
S1
S1
Panel
Main
S2
UPPER GROUND LOWER GROUND
E ELECTRICAL LIGHTING LAYOUT
E2E2
F ELECTRICAL LIGHTING LAYOUT
E2E2
SCALE 1:100 MTS SCALE 1:100 MTS
ARCHITECT ALL MEASUREMENT ARE TO BE
ENGINEER PROJECT TITLE OWNER DESIGNED BY : VLM AS - BUILT SHEET CONTENTS SHEET NO.
VERIFIED ON SITE BY THE
CONTRACTOR. ALL DISCREPANCIES
ARE IMMEDIATELY TO BE REPORTED CADD BY : GLB
E
TO THE ARCHITECT PRIOR TO
C:\DRWG\Mix dwg\matibay.bmp
CEMMENCEMENT OF WORKS. PROPOSED SPLIT TYPE
Mrs. VIRGINIA J. GUILLERMO DATE June 22, 2022
RA 545 THREE BEDROOMS RESIDENCE AS BIULT PLAN
2
THIS DRAWING ACTING AS INSTRUMENT
OF SERVICE IS THE PROPERTY OF THE CHECKED BY : VLM
ARCHITECXTAND CANNOT BE
REPRODUCED WITHOUT THEIR
CONSENT. Lot 16, Blk 2, Subdivision, Crestal Verde, Novaliches Quezon City DATE / PLACE -