BUILDING EFFICIENCY

Energy Efficient Variable Speed EC Motor


Fan Coil Unit Solutions
Model YECAH
Product Introduction

INTRODUCTION
Johnson Controls YORK® YECAH ceiling mounted compact cabinet fan coil units are
high airflow and high static pressure air-conditioning units using high efficiency 355 mm
diameter EC plug fan(s).
YECAH fan coil units have been designed incorporating variable speed EC motor
technology to meet the needs of today's sustainable building designs and to exceed
the stringent European ErP 2015 energy standard . They are the ideal HVAC solution
for both new construction and revovation projects for hotels, retail centers, office
buildings, and education facilities. The 355 mm diameter EC plug fans operate at lower
RPM , lower noise , and higher efficiency levels when compared to ceiling concealed
units incorporating multiple fans with smaller diameter impellers.
YECAH fan coils are available in 4 models with integral EC fan(s) incorporate fully large removable access panels to the fan
variable 0-10v speed control, and are suitable for a wide range of chilled water and hot section.
water flow rates, including wide delta T applications to maximize pump energy savings.
YECAH fan coil units are available with multiple coil options for each model (the 2 pipe Cooling and heating coil use copper tubes
system has 4 or 6 rows, and the 4 pipe system has 4+1, 6+1, 4+2 or 6+2 rows). The air with corrugated aluminium fins, mounted
flow ranges from nominal 750 L/s to 1500 L/s, while the external static pressure ranges above a full stainless steel drain pan. The
from 175 Pa to 375 Pa. EC plug fan(s) feature EC technology and
with a wide RPM range, can satisfy variable
Each YECAH unit is made of galvanized steel with 15 mm thick non-combustible airflow and pressure from a 0 - 10 vdc
thermal insulation. It contains built-in cooling & heating coils, single or dual EC variable control signal. A MODBUS high level data
speed plug fan assemblies, a removable inspection panel with sash catches, and connection is provided as standard.

4R Cooling Coil Only


Coils 6R Cooling Coil Only
1R/ 2R Heating Coil
Motor Protection IP 54 - 50 Hz
Fin Protection Hydrophilic Fin
Drain Pan Stainless Steel Drain Pan
GENERAL
Coil header Copper
G1(Nylon) filter
G1(Aluminium mesh) filter
Filters & Rails
G3 Plate filter
G4 Plate filter
Lengend Thermostat

Lengend:
Standard
Option

2
ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH

Nomenclature & Feature

NOMENCLATURE

YECAH 03 D 4 0 0 0 L A

York EC Fan Ceiling-mounted AHU Series

Unit Size: Connection Type:


03: 750l/s L:Left
04: 1000l/s R:Right
05: 1250l/s
06: 1500l/s 0: Mixed air condition
X: Fresh air condition
Direct drive
0: no filter
No. of Rows: A:G1(nylon)
4:4Row cooling B:G1(AL.)
6:6Row cooling C:G3
D:G4

0: no heating coil
1: 1R heating coil
2: 2R heating coil

FEATURES AND BENEFITS


Coil is made of expanded copper tubes and corrugated fins to achieve
Significant energy savings
high exchange efficiency.
Energy saving Fan and motor performance rating exceeds the 2015 ErP (European
355mm diameter EC plug fans fans provide high efficiency and static
Energy- related Products Directive)
capability over wide operation range
Each fan and motor assembly has been dynamically and statically
Low noise level balanced Whisper quiet comfort condition results in satisfied occupants.
Variable speed, low noise, directly driven EC fan

Full Drain pan allows quick and easy drainage of condensation. Drain
Easy drainage Full drain pan design provides superior condensate management.
pan is made of high quality stainless steel.

Compact size & low Ceiling concealed unit is restricted to 508 mm height to fit within
Suits many ducted HVAC applications
height commercial building ceiling spaces

Threaded Brass connector is provided for easy piping connection. Purge


Easy of installation Reduces installation and commissioning time and cost.
valves are provided on all coils to assist in commissioning.

EC fans are direct drive with sealed for life bearings. Inspection panel
Easy maintenance allows fast and easy periodic inspection of coil and drain tray. Optional Reduced maintenance time and cost.
unit mounted filter track

3
Technical Specifications

MODEL YECAH03 YECAH04 YECAH05 YECAH06


Performance
Nominal Air Flow L/S 750 1000 1250 1500
Nominal External Static Pressure Pa 175 175 175 175
COIL
Face Area sq.m 0.284 0.508 0.508 0.610
Face Velocity m/s 2.64 1.97 2.46 2.46
Header Material Copper
Max Working Pressure kPa 1600
COOLING COIL
4 Rows 0.31 0.45 0.48 0.62
Water Flow Rate L/S
6 Rows 0.40 0.59 0.66 0.82
4 Rows 17.2 20.2 10.3 25.8
Water Pressure Drop kPa
6 Rows 18.0 26.5 23.9 18.4
4 Rows 3.0 3.8 3.8 4.6
Water Content L
6 Rows 4.6 5.7 5.7 6.8
4 Rows 130 75 105 105
Air Pressure Drop Pa
6 Rows 205 115 165 165
4 Rows 9.1 13.2 14.0 18.2
Nominal Capacity kW
6 Rows 11.7 17.4 19.3 23.8
HEATING COIL
1 Row 0.12 0.19 0.21 0.25
Water Flow Rate L/S
2 Rows 0.27 0.42 0.47 0.58
1 Row 2.0 7.5 8.8 15.0
Water Pressure Drop kPa
2 Rows 2.5 9.3 11.7 19.7
1 Row 0.8 0.9 0.9 1.1
Water Content L
2 Rows 1.5 1.9 1.9 2.3
1 Row 25 15 20 20
Air Pressure Drop Pa
2 Rows 55 30 45 45
1 Row 9.9 15.5 16.9 20.6
Nominal Capacity kW
2 Rows 21.6 34.2 38.6 47.0
MOTOR
Type Electronically Commutated
No. of Motor 1 1 2 2
Nameplate Rating Input W 750 750 750×2 750×2
Control Signal Input V 0~10VDC
Nameplate Amps (220V / 1 Ph. / 50 - 60 Hz.) A 3.3 3.3 3.3×2 3.3×2
Nameplate Power Supply - 230V / 1 Ph. / 50 - 60 Hz
FAN
Type BC SWSI Plug
Quantity 1 1 2 2
UNIT DIMENSIONS
Length mm 940 940 940 940
Width mm 950 1500 1500 1750
Height mm 508 508 508 508
Weight(4R Coil) kg 151 186 201 220
Weight (6R+2R Coil) kg 168 210 225 250

Note: 1. Standard mixed air cooling conditions: air inlet at 23°C DB/17°C WB; chilled water inlet/outlet at 6°C/13°C. 4. The weight listed in the table is the shipping weight.
2. Cooling Coil APD at wet condition. 5. The weight does not include water volumes.
3. Heating Coil APD at dry condition.

4
ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH

Technical Specifications

YECAH Air Flow Range

YECAH06
Unit Model

YECAH05

YECAH04

YECAH03

250 500 750 1000 1250 1500 1750

Air Flow L/s

5
Technical Specifications

MOTOR POWER INPUT(W) 4 Rows Cooling Coil+1 Row Heating Coil

MODEL ESP (Pa) 550 L/S 680 L/S 750 L/S 460 L/S 620 L/S 730 L/S 360 L/S 540 L/S 680 L/S 460 L/S 620 L/S 380 L/S 550 L/S
175 391 567 744

225 377 560 741

YECAH03 275 360 545 742

325 531 734

375 512 736

MODEL ESP (Pa) 750 L/S 910 L/S 1040 L/S 680 L/S 850 L/S 990 L/S 590 L/S 790 L/S 930 L/S 720 L/S 870 L/S 630 L/S 800 L/S

175 390 543 715

225 396 555 727

YECAH04 275 393 562 732

325 565 738

375 553 738

MODEL ESP (Pa) 900 L/S 1160 L/S 1350 L/S 800 L/S 1110 L/S 1290 L/S 940 L/S 1250 L/S 1350 L/S 1190 L/S 1350 L/S 1010 L/S 1330 L/S

175 498 819 1161

225 527 782 1130

YECAH05 275 765 1138 1350

325 1125 1450

375 1154 1486

MODEL ESP (Pa) 990 L/S 1350 L/S 1620 L/S 1190 L/S 1500 L/S 1620 L/S 980 L/S 1390 L/S 1620 L/S 1240 L/S 1550 L/S 1050 L/S 1430 L/S

175 503 774 1088

225 767 1071 1200

YECAH06 275 755 1090 1450

325 1080 1451

375 1074 1448

6
ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH

MOTOR POWER INPUT(W) 6 Rows Cooling Coil+1 Row Heating Coil

MODEL ESP (Pa) 570 L/S 680 L/S 700 L/S 460 L/S 610 L/S 630 L/S 350 L/S 520 L/S 550 L/S 410 L/S 480 L/S 330 L/S 400 L/S
175 530 715 745

225 507 704 744

YECAH03 275 477 683 745

325 645 743

375 626 743

MODEL ESP (Pa) 740 L/S 890 L/S 1010 L/S 660 L/S 830 L/S 970 L/S 570 L/S 760 L/S 900 L/S 690 L/S 840 L/S 620 L/S 770 L/S

175 398 545 713

225 396 554 735

YECAH04 275 397 559 737

325 571 738

375 565 737

MODEL ESP (Pa) 910 L/S 1200 L/S 1350 L/S 1080 L/S 1250 L/S 1350 L/S 960 L/S 1240 L/S 1350 L/S 1120 L/S 1350 L/S 1020 L/S 1260 L/S

175 525 806 975

225 793 975 1139

YECAH05 275 787 1131 1350

325 1120 1480

375 1108 1483

MODEL ESP (Pa) 910 L/S 1260 L/S 1550 L/S 1140 L/S 1410 L/S 1620 L/S 980 L/S 1280 L/S 1590 L/S 1180 L/S 1480 L/S 1050 L/S 1360 L/S

175 483 770 1082

225 758 1090 1450

YECAH06 275 747 1086 1457

325 1071 1456

375 1049 1450

Note: Airflow and inputpower datas are for dry coil and without filter.

7
Performance Data

PERFORMANCE RATINGS COOLING COIL

Air Inlet Temp(Dry Bulb/Wet Bulb) 27℃/19℃ Air Inlet Temp(Dry Bulb/Wet Bulb) 23℃/17℃ Air Inlet Temp(Dry Bulb/Wet Bulb) 35℃/24℃
Inlet
Air Off Air Off Air Off
Chilled Total Sensible Water Water Total Sensible Water Water Total Sensible Water Water
Airflow Rows Temp Temp Temp
Model Water Cooling Cooling Flow Pressure Cooling Cooling Flow Pressure Cooling Cooling Flow Pressure
(Dry Bulb/ (Dry Bulb/ (Dry Bulb/
Temp Capacity Capacity Rate Drop Capacity Capacity Rate Drop Capacity Capacity Rate Drop
Wet Bulb) Wet Bulb) Wet Bulb)
L/S ℃ kW kW ℃ L/S kPa kW kW ℃ L/S kPa kW kW ℃ L/S kPa
5 14.5 10.8 14.9/13.2 0.50 36.7 10.5 8.1 14.0/12.7 0.35 22.0 25.1 16.1 16.6/15.0 0.85 43.7
6 13.0 10.1 15.7/13.9 0.44 30.5 9.1 7.5 14.7/13.3 0.31 17.2 23.6 15.5 17.2/15.6 0.81 39.7
4 7 11.6 9.5 16.3/14.4 0.40 25.3 7.8 6.8 15.4/13.9 0.27 12.9 21.8 14.8 18.1/16.3 0.75 34.2
8 10.4 9.0 17.0/15.0 0.35 21.3 6.6 6.2 16.1/14.3 0.23 9.7 20.1 14.1 18.9/17.0 0.68 29.0
9 9.3 8.4 17.6/15.4 0.32 17.5 5.7 5.6 16.8/14.7 0.20 7.4 18.6 13.5 19.6/17.6 0.63 26.0
YECAH03 750
5 18.2 12.9 12.6/11.5 0.62 37.1 13.4 9.8 12.2/11.3 0.46 22.6 28.2 17.6 14.9/13.6 0.96 26.5
6 16.4 12.1 13.5/12.3 0.56 30.7 11.7 9.0 13.0/12.1 0.40 18.0 26.5 16.9 15.7/14.4 0.91 24.1
6 7 14.8 11.3 14.3/13.1 0.50 25.8 10.2 8.3 13.8/12.8 0.35 14.4 24.6 16.0 16.7/15.2 0.84 20.6
8 13.2 10.7 15.1/13.8 0.46 21.8 8.7 7.6 14.6/13.5 0.29 10.5 22.8 15.3 17.5/16.0 0.78 18.3
9 11.7 10.0 15.8/14.4 0.40 17.4 7.5 6.9 15.3/14.0 0.25 8.2 20.9 14.6 18.4/16.7 0.71 15.7
5 20.0 14.4 14.9/13.0 0.68 41.4 15.0 11.0 13.9/12.3 0.51 24.9 29.5 19.0 18.7/16.2 1.01 13.3
6 18.1 13.5 15.7/13.6 0.61 34.1 13.2 10.2 14.5/12.9 0.45 20.2 27.4 18.2 19.4/16.9 0.94 11.5
4 7 16.3 12.7 16.3/14.2 0.56 29.5 11.4 9.4 15.2/13.5 0.39 15.3 25.0 17.2 20.3/17.6 0.85 9.6
8 14.5 11.9 17.0/14.8 0.50 23.6 9.8 8.6 15.9/14.0 0.34 11.5 23.1 16.4 20.9/18.1 0.79 8.5
9 12.9 11.2 17.6/15.3 0.44 19.1 8.4 7.8 16.5/14.5 0.29 8.8 21.1 15.6 21.6/18.7 0.72 7.1
YECAH04 1000
5 26.6 18.5 11.5/10.7 0.91 58.3 19.9 14.2 11.3/10.6 0.68 34.3 38.1 24.0 14.4/13.5 1.29 18.7
6 24.1 17.3 12.5/11.6 0.83 48.4 17.4 13.0 12.2/11.5 0.59 26.5 35.5 22.9 15.4/14.3 1.20 16.4
6 7 21.6 16.2 13.4/12.4 0.74 39.3 15.1 12.0 13.1/12.3 0.51 20.6 32.9 21.8 16.3/15.2 1.12 14.2
8 19.3 15.2 14.2/13.2 0.66 32.4 13.0 11.0 13.9/13.0 0.44 15.4 30.2 20.8 17.2/16.0 1.03 12.1
9 17.2 14.3 15.0/13.9 0.59 26.0 11.0 10.0 14.7/13.6 0.38 11.3 27.6 19.8 18.1/16.8 0.94 10.2
5 22.2 16.7 15.8/13.7 0.76 23.9 15.9 12.5 14.7/13.1 0.54 12.9 37.5 24.5 18.2/16.1 1.28 19.1
6 19.9 15.6 16.5/14.3 0.68 19.2 14.0 11.6 15.3/13.6 0.48 10.3 34.6 23.4 19.0/16.8 1.17 16.0
4 7 17.9 14.7 17.1/14.8 0.61 16.1 11.9 10.5 16.0/14.1 0.41 7.5 32.0 22.3 19.7/17.4 1.10 14.1
8 15.9 13.8 17.8/15.3 0.54 12.7 10.1 9.5 16.7/14.6 0.34 5.5 29.3 21.2 20.5/18.0 1.00 11.8
9 14.1 12.8 18.4/15.8 0.48 10.2 8.7 8.5 17.3/14.9 0.29 4.1 26.6 20.2 21.2/18.6 0.90 9.8
YECAH05 1250
5 29.0 20.5 13.3/11.9 0.98 47.7 22.0 15.9 12.5/11.4 0.75 30.6 42.4 27.0 16.5/14.8 1.44 17.1
6 26.4 19.3 14.0/12.6 0.90 41.7 19.3 14.6 13.3/12.2 0.66 23.9 39.3 25.6 17.4/15.6 1.34 14.8
6 7 23.9 18.2 14.8/13.3 0.82 35.2 16.8 13.4 14.1/12.9 0.57 18.6 36.3 24.4 18.3/16.4 1.23 12.6
8 21.3 17.0 15.6/14.0 0.72 28.1 14.4 12.3 14.8/13.5 0.49 14.0 33.6 23.3 19.0/17.0 1.14 11.0
9 18.9 15.9 16.3/14.6 0.64 22.6 12.4 11.3 15.5/14.0 0.42 10.5 30.6 22.2 19.8/17.7 1.04 9.1
5 28.0 20.7 15.4/13.4 0.95 55.6 21.0 15.9 14.2/12.7 0.72 34.1 47.0 30.3 17.7/15.7 1.60 44.0
6 25.3 19.5 16.1/14.0 0.86 46.6 18.2 14.6 14.9/13.3 0.62 25.8 44.0 29.1 18.3/16.3 1.50 39.0
4 7 22.8 18.3 16.7/14.5 0.78 39.4 15.9 13.5 15.6/13.8 0.54 20.3 40.7 27.8 19.1/16.9 1.38 33.4
8 20.4 17.2 17.4/15.1 0.69 31.6 13.7 12.3 16.2/14.2 0.47 15.4 37.6 26.5 19.9/17.5 1.29 29.2
9 18.2 16.1 18.0/15.5 0.62 25.5 11.7 11.1 16.9/14.7 0.39 11.1 34.7 25.3 20.5/18.1 1.18 25.6
YECAH06 1500
5 36.5 25.9 12.5/11.5 1.24 40.2 27.2 19.9 12.0/11.2 0.93 23.7 56.8 35.6 14.7/13.5 1.92 33.2
6 33.0 24.3 13.4/12.3 1.12 33.5 23.8 18.3 12.9/12.0 0.82 18.4 53.2 34.0 15.5/14.3 1.81 28.8
6 7 29.6 22.8 14.2/13.1 1.01 27.3 20.5 16.8 13.7/12.8 0.70 13.7 49.5 32.5 16.5/15.1 1.69 25.4
8 26.4 21.4 15.0/13.8 0.89 21.6 17.6 15.4 14.5/13.4 0.60 10.3 45.9 31.0 17.3/15.9 1.57 22.2
9 23.4 20.1 15.8/14.4 0.79 17.4 14.9 13.9 15.3/14.0 0.50 7.3 42.0 29.4 18.2/16.7 1.43 18.4

Note: The temperature difference of inlet/outlet water is 7°C

8
ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH

Performance Data

PERFORMANCE RATINGS HEATING COIL

Air Inlet Temp(Dry Bulb)

Inlet Hot 21℃ 15℃ 7℃


Airflow Rows Water
Model Temp Total Water Water Total Water Water Total Water Water
Air Off Air Off Air Off
Heating Flow Pressure Heating Flow Pressure Heating Flow Pressure
Temp Temp Temp
Capacity Rate Drop Capacity Rate Drop Capacity Rate Drop

L/S ℃ kW ℃ L/S kPa kW ℃ L/S kPa kW ℃ L/S kPa

1 80 9.9 31.9 0.12 2.0 11.3 27.3 0.14 2.6 13.2 20.9 0.16 3.53
YECAH03 750
2 80 21.6 44.8 0.27 2.5 24.8 41.8 0.30 3.2 29.1 37.7 0.36 4.36

1 80 15.5 33.8 0.19 7.5 17.6 29.3 0.21 9.6 20.4 23.1 0.25 12.67
YECAH04 1000
2 80 34.2 49.3 0.42 9.3 39.0 46.7 0.48 12.0 45.5 42.9 0.56 15.93

1 80 16.9 32.2 0.21 8.8 19.3 27.5 0.23 11.3 22.4 21.1 0.28 15.09
YECAH05 1250
2 80 38.6 46.6 0.47 11.7 44.0 43.6 0.54 14.9 51.3 39.4 0.63 20.03

1 80 20.6 32.4 0.25 15.0 23.4 27.7 0.29 19.2 27.2 21.3 0.33 25.38
YECAH06 1500
2 80 47.0 46.9 0.58 19.7 53.5 43.9 0.66 25.1 62.3 39.8 0.76 33.75

9
Acoustics

SOUND POWER LEVEL 4 Rows Cooling Coil+1 Row Heating Coil

Model ESP(Pa) Air Flow (L/S) 63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz dB(A)

550 32.2 44.4 45.9 48.2 47.4 42.1 38.6 36.5 53.4
YECAH03 175
750 37.3 48.8 52.3 51.7 53.1 48.3 41.5 40.5 58.4

800 26.4 47.8 45.0 50.9 56.4 51.8 46.9 43.1 59.4
YECAH04 175
1000 30.1 43.2 47.9 53.2 58.6 53.8 48.9 44.8 61.3

1050 28.7 45.9 46.3 49.5 48.9 41.6 36.3 34.2 54.3
YECAH05 175
1250 31.2 45.8 48.6 53.4 52.2 44.0 37.9 35.6 57.3

1300 28.5 45.1 47.6 49.5 49.4 39.7 34.6 33.0 54.5
YECAH06 175
1500 31.1 45.0 49.6 52.1 51.9 41.5 35.4 34.4 56.7

SOUND POWER LEVEL 6 Rows Cooling Coil+1 Row Heating Coil

Model ESP(Pa) Air Flow (L/S) 63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz dB(A)

550 34.4 45.8 47.9 51.5 52.4 48.7 42.7 38.9 57.2
YECAH03 175
700 37.2 48.8 51.1 52.7 55.1 51.2 45.3 40.4 59.5

800 29.0 43.7 49.0 53.5 55.2 51.8 45.0 40.2 59.3
YECAH04 175
1000 34.6 46.5 51.8 54.6 58.2 52.9 45.6 42.9 61.4

1050 36.7 50.6 52.9 52.7 52.2 42.5 34.4 30.1 58.4
YECAH05 175
1250 38.0 52.0 56.4 55.4 55.6 45.4 38.8 31.4 61.3

1300 31.6 48.2 50.7 52.6 52.5 42.8 37.7 36.1 57.6
YECAH06 175
1500 34.4 48.3 52.9 55.4 55.2 44.8 38.7 37.7 60.0

Casing Radiated Sound Power Test:


According to JBT4330-1999 and ISO3744, casing radiated sound power level is tested in hemi-anechoic room. Unit tested with 3 meters of inlet and 3 meters of outlet ductwork.

10
ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH

Units Drawings

Cooling Only

11
Units Drawings

Cooling and Heating

Inlet flange
W Outlet flange size Piping position
size
Model J K HK HN
B D E P
with 1R HC with 2R HC 4 rows 6 rows 1 row 2 rows 1 row 2 rows

YECAH03 950 326 450 804 160.5 182.5 66 110 44 66 407 420

YECAH04 1500 451 600 1360 160.5 182.5 66 110 44 66 407 420

YECAH05 1500 329 950 1360 160.5 182.5 66 110 44 66 407 420

YECAH06 1750 376 1200 1610 160.5 182.5 66 110 44 66 407 420

Notes:
1. The coil pipe connections use male threads(thread code R2)
1" - OD 34mm 1 1/2" - 48mm
2. The condensate pipe connections use 34mm O.D. male threads(thread code R2)
3. All dimensions are SI unit(mm)

12
ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH

Fan Performance Curves

YECAH03 4R Cooling+1R Heating YECAH03 6R Cooling+1R Heating

Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture
removal conditions. removal conditions.

YECAH04 4R Cooling+1R Heating YECAH04 6R Cooling+1R Heating

Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture
removal conditions. removal conditions.

13
Fan Performance Curves

YECAH05 4R Cooling+1R Heating YECAH05 6R Cooling+1R Heating

Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture
removal conditions. removal conditions.

YECAH06 4R Cooling+1R Heating YECAH06 6R Cooling+1R Heating

Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture Note: Airflows are for dry coil and without filter. Reduce airflow by 10% in high moisture
removal conditions. removal conditions.

14
ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH

Electrical Data and Wiring

MOTOR WIRING TAG


Power supply Alarm relay Interface 0-10VDC
230V ~ 50Hz output for Modbus Input

Field wiring by User

Wiring in Factory QF

NB1 NB2

User Terminals(TB) L N PE NC1 C NC2 A B AI COM 10V


PE

NC

NC
2

5
1

8
7

Motor Terminals L N PE NC C RSA RSB 0-10V GND 10V L N PE NC C RSA RSB 0-10V GND 10V

M M
~ ~
Notes: NB3
Fan Motor(MF) Fan Motor(MF)
NB1 Option control interface: RS485 interface for Modbus.
NB2 Terminal 10V: Fixed voltage output 10VDC, max 10mA. Fan Motor will run at full speed if 10V and AI terminals are shorted.
NB3 Single Fan Motor units do not have these parts of wiring.

15
TEC3000 Series Thermostat Controllers

TEC3000 Series Thermostat Controllers Some models have occupancy sensing


are stand-alone and field-selectable capability built into the device. These
BACnet® Master-Slave/Token-Passing thermostat controllers can deliver further
(MS/TP) or N2 networked devices that energy savings of up to 30% by using
provide on/off, floating, and proportional additional standby set-points.
control of two or four-pipe fan coils with
variable-speed EC motors (0 to 10 VDC These thermostats feature two
control) configurable binary inputs that provide for
advanced functions such as remote night
The networked models feature a field- setback, service or filter alarms, motion
selectable Building Automation System detector, and key switch or window status,
(BAS) BACnet MS/TP or N2 communication and configures the application to respond
capability that enables remote monitoring accordingly.
and programming for efficient space
temperature control. A Full Line of Remote TE-6300 Series
Temperature Sensors supports a wide
All models include a USB port configuration range of applications.
that reduces installation time by allowing
simple backup and restore features from
a USB drive, which enables rapid cloning
of the configuration between like units.

All models feature an intuitive user
interface with backlit display that makes
setup and operation quick and easy. The
Backlit Liquid Crystal Display (LCD) offers
real-time control status of the environment
in easy-to-read, plain text messages with
adjustable backlight that brightens during
user interaction.

16
ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH

Guide Specifications

GENERAL before assembly. Coil shall be provided TERMINAL BOX


Furnish and install ceiling-mounted with a manual air vent on the top. The All units shall be provided with factory
compact air handling units not exceding coil assembly shall be protected on the installed terminal box with the fan motor
508mm height as indicated and scheduled side on which piping is to be fitted with a wired to the box. the terminal box shall
in the plans. Units shall be factory cover made of GI sheet. A full drain pan include a DIN rail type terminal strip
assembled with coils that are pressure shall be provided to the base of the unit that has connections for incoming 240v
tested individually to 400 psi (2.8 MPa). manufactured of stainless steel to prevent power, 0-10v dc speed control, a common
The unit shall incorporate one or two corrosion. fault contact, and a MODBUS high level
355mm diameter directly driven EC plug data interface. Where multiple fans are
fans with integral variable speed drive(s). MOTORS provided they shall be factory wired to the
The units shall be suitable for operation High efficiency electronically commutated common terminal strip.
on 240 volt single phase 50 hz power. (EC) motors shall be fitted as standard on
all units. Motor can be regulated by 0-10V FILTER
BASIC UNIT dc signal supplied by a BMS, thermostat As an option, panel filters shall be provided
The unit panels shall be fabricated out or DDC controller. The motor is resiliently to a 25mm channel frame mounted on the
of 1mm galvanized steel. The unit shall mounted, self aligning and oiled for life. air inlet of the unit.
be lined with 15 mm Class 1 PE thermal A MODBUS high level connection shall be
insulation. The fan motor(s) shall be easily provided.
removable for serviceability. A terminal
box with terminal strip shall be provided FANS
for terminating the wiring. An inspection The unit shall utilize one or two 355mm
panel with sash catches shall be provided diameter EC plug fan(s), dynamically
for easy inspection of coil and drain balanced, incorporating backward curved
pan. impellers each with a direct drive EC
motor. The fan motor assembly shall be
COILS designed for low-noise, variable speed
Copper tube with corrugated aluminum operation from a 0-10v dc control input.
hydrophilic fins. Aluminum fins shall be EC fan assemblies shall be installed in
0.110mm thick and the coil shall have an insulated plenum section with large
maximum spacing of 2.3mm between removable access panels fitted to both
the fins. The coil shall be pressure tested sides of the air handling unit for ease of
under water to 2.8 MPa (For a working service and replacement.
pressure of 1600 kpa) and dehydrated

17
Solutions for your success
Every building is unique in design and Johnson Controls can handle many challenges with its innovative and flexible solutions.
technical requirements. From A to Z, from consulting to planning, installation, maintenance (service, inspection
Our customers always receive customised and repair) and modernisation – Johnson Controls supports customers throughout the
building solutions to meet their individual entire life cycle of a building.
needs.

High Efficiency Chiller

Building Automation &


Chiller Plant Optimization

Variable Air Volume

18
ENERGY EFFICIENT EC MOTOR AHU SOLUTIONS MODEL YECAH

Our well thought-out solutions guarantee a high level of comfort and energy efficiency. External systems can be easily integrated
The majority of our products are already rated as Class A for Energy Efficiency, with using BACnet® or proprietary solutions.
high levels of compatibility and flexibility allowing for future additions to be carried out Our service team is available to you 24
without difficulty. hours a day with one of the largest service
networks in Europe.

EC Motor AHUs

EC Motor FCUs

EC Motor Ceiling AHUs

Service Solutions

Energy Management & Reporting

19
Office Locations
Australia (Melbourne) Indonesia Malaysia (Kuala Lumpur)
Tel: +61 (3) 9751 5000 Tel: +62 (21) 5366 8500 Tel: +60 (3) 7628 4300
Fax: +61 (3) 9755 7566 Fax: +61 (21) 5366 8300 Fax: +60 (3) 7874 1180

China (Shanghai) Japan New Zealand


Tel: +86 (21) 6276 6509 Tel: +81 (3) 5738 6100 Tel: +64 (9) 444 6434
Fax: +86 (21) 6277 3543 Fax: +81 (3) 5738 6298 Fax: +64 (9) 444 2092

Hong Kong Korea Singapore


Tel: +852 2590 0012 Tel: +822 554 5935 Tel: +65 6748 0202
Fax: +852 2516 5648 Fax: +822 554 5739 Fax: +65 6743 4420

India (Mumbai) Macau Thailand (Bangkok)


Tel: +91 (22) 6617 4107 Tel: +853 2875 1820 Tel: +66 (2) 717 1260-80
Fax: +91 (22) 6683 7002 Fax: +853 2875 1825 Fax: +66 (2) 717 1325-8

PUBL-7895 (1215)

You might also like